• Title/Summary/Keyword: Task Lighting

Search Result 52, Processing Time 0.022 seconds

Empirical Evaluation of Optimal User-Centered LED Lighting Environments in Residential Bathrooms

  • Lee, Jeongmin;Choi, Kyungah;Suk, Hyeon-Jeong
    • Science of Emotion and Sensibility
    • /
    • v.16 no.3
    • /
    • pp.305-310
    • /
    • 2013
  • This user-centered research aims to empirically evaluate color temperature (K) and illuminance (lx) of residential bathroom lightings to determine the most optimal lighting conditions for productive task performance as well as for satisfying users' emotional needs. Using 3 LED lighting fixtures, 4 types of lighting contexts were investigated; main lighting, task lighting, shower lighting, and bath lighting. Two lightings were installed parallel to the vertical edges of the main bathroom mirror to be used as main and task lighting, while another fixture was installed above the bathtub to be used for shower and bathing. For each lighting context, subjects (N=54) were instructed to perform a few tasks during which time the users were exposed to different lighting conditions with color temperature ranging from 2700 K ~ 6500 K and illuminance ranging from 100 lx ~ 700 lx. Upon completing the given tasks, subjects were asked to evaluate the lighting conditions and their applicability for performing the given tasks. Based on the user evaluations, the most optimal lighting conditions for the different lighting scenarios are as follow: 1) 3500 K ~ 4300 K and 150 lx for main lighting, 2) 3500 K ~ 4300 K and 500 lx ~ 700 lx for task lighting, and 3) 2700 K ~ 3500 K and 100 lx ~ 150 lx for shower/bath lighting. These results can be used to adjust the lighting standards suggested by KS, as well as be utilized by both engineers and designers in designing new types of user-centered bathroom lightings.

  • PDF

Analysis of electrical and optical characteristic of surface lighting using organic light-emitting diodes (OLED 면광원의 특성 분석)

  • Kim, Do-Hwan;Na, Jong-Hyuck;Lee, Hyung-Young;Jeon, Sang-Kyoo;Cho, Mee-Ryoung;Choi, Yong-Won;Yang, Seong-Yong
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2009.10a
    • /
    • pp.159-162
    • /
    • 2009
  • Surface lighting using OLEDs for desk/task lighting has been analyzed its electrical and optical characteristic with a fluorescent lamp which has triple wavelength peak. We have confirmed the good possibility of OLEDs for desk/task lighting. Our engineering sample which has fabricated by co-worker has its characteristics which are luminous efficacy 11.781m/W at 509mW, CRI Index 75, CCT 4479K, CRI coordinate x=0.378, y=0.4547, respectively. Addinationly another OLEDs samples are used for compartive analysis in view of desk/task lighting.

  • PDF

A Study on the Development of Database for Lighting Design System (조명 설계 시스템을 위한 데이터베이스 개발에 관한 연구)

  • 조성오
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.4
    • /
    • pp.196-203
    • /
    • 2004
  • In The Lighting design is important to acknowledge appearance space. Development of artificial light makes a extension to life space in the Modern life. With the rapid development of efficient light sources, have lighting design acquired the tools that allow artificial lighting to be produced with adequate illuminance levels. However, by the task of defining the objectives and methods behind discipline, of deciding on the criteria by which the artificial lighting that is now provide many available data to be anpaied. The main concern is which illuminace levels and types of lighting will ensure optimum visual performance, high productive and safety at design which are affordable. This study is support to standard design process with material reflection rate, installing the lighting fixture, task illuminance level and automatic arithmetic calculation during the lighting design. Lighting Design database can check and support other final lighting level. A quantitative light that is primarily oriented toward providing a recommended illuminance level, the criterion of develop a concept that goes beyond the requirements that would ensure productivity and safety to meet the needs of the architecture and interior space. illuminance level is compose to space task and space code according to KS A 3011. To be able to design the visual effect of an environment the central reference quantity has to provided the Database.

Study of Efficiency Test and Subjective Responses about Pendent Task Lighting System Using Phosphor Luminescent Film LED (광기여 필름 LED 팬던트 작업조명시스템 주관평가와 성능검증)

  • Cha, Kwang-Seok;Kim, Hway-Suh
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.3
    • /
    • pp.188-193
    • /
    • 2011
  • For a long time work or study, pendent task lighting system prepared with phosphor luminescent film LED was developed for eye protection and working efficiency improvement. Developed lighting system was used together with pendent and ambient lighting. Such as, we made comfortable lighting environment system. Evaluation for developed lighting system, that had proceeded to Mock-up test and subjective evaluation. Also It had proceeded that lighting environment analyzed and compatibility valuation of installation. In subjective evaluation, the students have expressed themselves satisfied to phosphor luminescent film LED lighting system. In Mock-up test, It is not problem to intensity of illumination, luminance and color temperature. Therefore, developed LED lighting system was installed at the Daegu apartment. It is having a P.O.E study progress to phosphor luminescent film LED lighting system.

Comparison of the Lighting Environment in Study Rooms for Juveniles between the City and the Country

  • Kim, Hyun-Ji;Jeon, Gyeong-Seon;An, Ok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.1-7
    • /
    • 2009
  • The research aims at providing data needed for planning the lighting of a study room by comparing the lighting environments of study rooms for urban and rural juveniles. The subject of the research was 300 students in middle schools in Daegu and Checngdo-gun, Gyeongsangbuk-do (Daegu 150 houses and Cheongdo 150 houses), and their study rooms were examined. The following is the result of the research. First, rural students stayed more time in their study room than urban students. The task that rural students (studying) and urban students (studying and using computer) all did in their study room was mainly visual work Second, although the sizes of rural study rooms were bigger than those of urban study rooms, urban study rooms had more light sources than rural study rooms. In the rate that of having a task lighting, the city(87.1[%]) was higher than the country (45.7[%]). However, the rate of using a task lighting was lot high in both the city and the country. Third, the result that compared the average values of illuminations on desk planes was that the average value of the city was 3.4 times higher than that of the country. Also, the average value of the country did not meet the standard illumination of Korean industrial standards (KS). In particular, it did not reach the lowest standard. The result is related with that only 52[%] of students who had a task lighting used it. Finally, the satisfaction of lighting environment in the city was generally higher than the country. Especially, although the country had a low illumination, the user showed a high satisfaction. It indicates that people living in the country need to understand about the needs of illumination.

A Study on Image Evaluation consequent on Lighting Environment in time of reading in Learning Space (학습공간에서의 독서 행위 시 조명환경에 따른 이미지평가 연구)

  • Lee, Jin-Sook;Park, Ji-Young;Seo, Eun-Ji
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.9
    • /
    • pp.1-9
    • /
    • 2015
  • The aim of this study is to deduce color temperature and illuminance by conducting the preference & affective evaluation consequent on illuminance change of ambient light in case of the lighting method of ambient light mixed with task light in time of reading which is visual work action among the action in learning space. As a result of the prior survey on preferred lighting method in time of the act of reading targeting 20 experts before doing evaluation, the method of lighting mixed with ambient light and task light was found to be the highest. Such a result is analyzed to be attributable to the fact that the less the difference in illuminance of nearby space and work surface because of the mixed method of lighting, the less the glare, which makes a reader feels easy and concentrate on reading. On the basis of descriptive statistics of evaluation results and impact analysis by category, this study recommends the application of combinations of ambient light illuminance ranging from 40lx to 100lx with color temperature of 5500~6000K in case of the method of lighting mixed with general light and task light.

A Development of Multi-Sensors LED Streetlight Lighting Control System Based on RTOS (RTOS 기반의 다중센서 LED 가로등 점등제어 시스템 설계)

  • In, Chi-Goog;Lin, Chi-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.37C no.11
    • /
    • pp.1020-1026
    • /
    • 2012
  • In this paper, we proposed a RTOS-based lighting control system to improve energy efficiency. This proposed system, real time process was designed to the specified division of the LED streetlight control module for the RTOS-based lighting control into three different tasks. The first task transmits LED lighting signal by measuring illuminance, and the second task transmits motion detecting signal using motion detector. In the third task, lighting control to LED was designed through passed control signal from other tasks The execution status was examined ports that are directly to the ATmega128 MCU for the verification of the system, and illuminance distribution and operating conditions were verified through LED street field test. The proposed RTOS-based lighting control system has brought improving system performance and also facilitate an addition of other functions, and it was possible to optimize energy saving by intelligent lighting pattern control.

Illuminance Distribution Analysis by Lighting Tower Position of o Soccer Stadium (축구 경기장의 조명타워 위치에 따른 조도분포 해석)

  • 김길영;최홍규;최병숙
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.1
    • /
    • pp.1-8
    • /
    • 2004
  • Nowadays the soccer becomes one of the best spot lighting sports in the world Especially the 2002 Korea-Japan World Cup was deeply impressed on all the korean. One goal of illuminating engineering should be the design of lighting system that can provide consistently high task visibility regardless of where a task might be located within a working space. The television broadcasting on the soccer has been an important role in the media. The standard of FIFA(The Federation Internationale do Football Association) requires recommended illuminance levels for artificial lighting for a player, an audience, TV broadcasting, as well as everybody in the stadium. This paper has proposed an algerian to select the suboptimal lighting tower position for watching and TV broadcasting a soccer game within a pleasant environment and an optimum illuminance distribution. The position using the software Philip's Calculux was chosen based an the calculations of a horizontal illuminance, vertical illuminance, uniformity, glare, and so on by changing lighting tower positions.

The effect of LED lighting hues on the rating and recognition of affective stimulus (LED 조명색상이 정서자극의 평정과 재인에 미치는 효과)

  • Pak, Hyen-Sou;Lee, Chan-Su;Jang, Ja-Soon
    • Science of Emotion and Sensibility
    • /
    • v.14 no.3
    • /
    • pp.371-384
    • /
    • 2011
  • Three experiments were carried out to examine how LED lighting hues influence to the rating and recognition of affective stimuli. In Experiment 1 and 2, IAPS affective pictures were used and an affective rating(valence and arousal) task and a recognition memory task were conducted under red, green, blue, and white hue LED lightings in Experiment 1 and cyan, magenta, yellow, and white ones in Experiment 2, respectively. In Experiment 3, affective words were used and the same two tasks were conducted under red, green, blue, and white hue LED lightings. According to the results of affective rating tasks, when primary hues(RGB) were used, red LED lighting elicited an excitement at the arousal dimension and green LED lighting evoked pleasantness at the valence one. When secondary hues(CMY) were used, magenta and cyan showed the similar but weaker patterns of responses comparing to red and green. The results of recognition memory task showed that the responses to the picture stimuli presented at green and cyan hue lightings tended to be a bit faster comparing to the stimuli presented at the other conditions but the difference was insignificant. In Experiment 3, however, recognition memory responses to the affective words presented at green hue lighting were faster significantly. These results indicate that warm colors like red and magenta elicit unpleasantness or excitement while cool colors like green and cyan evoke pleasantness or relaxation, and the primary hues provoke more positive or negative affectivity than secondary ones do. Particularly, the result of recognition memory task in Experiment 3 suggests that green hue LED lighting might be advantageous at the memory performance of language stimuli rather than visual ones.

  • PDF

Psycho-physicological Effects of the Dynamic lighting on VDT workers (조명환경의 변동이 작업자에게 미치는 심리.생리적 영향)

  • 엄기수;박근상
    • Proceedings of the ESK Conference
    • /
    • 1998.04a
    • /
    • pp.194-199
    • /
    • 1998
  • The purpose of this study is conducted to evaluate the psycho-physiological effects of the dynamic lighting on VDT workers and to establish the dynamic lighting design guides. The main experimental factors are changes of illuminance. There were five conditions including 1) ripid change, 2) slow change at 300lx .approx. 500lx, 3) a static illuminance level at 300lx, and 4) rapid chante, 5) slow change at 200lx .approx. 300lx. The ranges of change were set typical illuminance level for the simple visual task requirement and reasonable to a VDT task ; 200-300-500lx. The psycho-physiological measurements used were EEG, R-R interval, CFF, near point accommodation, feeling perceived fatigue, and work performance. Analysis of psycho-physiological factors shows that higher illumination level conditions are more affirmative effects than lower on VDT workers under 500lx except for the results of feeling perceived fatigue. And about the speed of changes of illuminance level. The conditions of slow change were better than the others in terms of the work performance as well as psycho-physiological results.

  • PDF