Nanotechnology for cancer therapy is playing a pivotal role in dramatically improving current approaches to cancer detection, diagnosis, and therapy while reducing toxic side effects associated with previous cancer therapy. A widespread understanding of these new technologies will lead to develop the more refined design of optimized nanoparticles with improved selectivity, efficacy and safety in the clinical practice of oncology. This review provides an integrated overview of applications and advances of nanotechnology in cancer therapy, based on molecular diagnostics, treatment, monitoring, target drug delivery, approved nanoparticle-based chemotherapeutic agents, and current clinical trials in the development of nanomedicine and ultimately personalized medicine.
The purpose of the present study was to examine gaze effects on spatial and kinematic characteristics during a pointing task. Subjects were asked to watch and point to an aimed target (2 mm in diameter) displayed on a vertically mounted board. Four gaze conditions were developed as combinations of "seeing-aiming" in terms of the eye movements: Focal-Focal (F-F), Focal-Fixing (F-X), Fixing-Focal (X-F), and Fixing-Fixing (X-X). Both the home target and an aimed target were presented for 1 second and then were disappeared in F-F and X-F. In X-F and X-X, only an aimed target disappeared after 1 second. Subjects were asked to point (with index finger tip) to an aimed target accurately as soon as the aimed target was removed. A significant main effect of gaze was found (p<.01) for normalized movement time. Peripheral retina targets had significantly larger absolute error compared to central retina targets on the x (medio-lateral) and z (superior-inferior) axes (p<.01). A significant undershooting to peripheral retina targets on the x axis was found (p<.01). F-F and X-F had larger peak velocities compared to F-X and X-X (p<.01). F-F and X-F were characterized by more time spent in the deceleration phase compared to F-X and X-X (p<.01). The present study demonstrates that central vision utilizes a form of on-line visual processing to reach to an object, and thus increases spatial accuracy. However, peripheral vision utilizes a relatively off-line visual processing with a dependency on proprioceptive information.
Purpose: This study compared the movement control ability of the ankle joint according to the type of muscle contraction, namely, eccentric or concentric contractions. Methods: Thirty-four healthy adult subjects participated in this study. As a single group, before the experiment, the subjects were trained on achieving the required position of the ankle around the target point by manually controlling the ankle dorsiflexion by 10°. Concentric contraction starts at 0° and continues until the target point of 10° is reached. During an eccentric contraction, the ankle joint starts at 20° ankle dorsiflexion and continues till the target point is reached. Movements using eccentric contraction and concentric contraction were randomly performed 3 times each. Results: The results of comparing the difference in the movement control ability of each type of muscle contraction of ankle dorsiflexion showed that the measurement-remeasurement error was significant in eccentric contraction. Conclusion: In this study, we found a difference in the ability to control movement according to whether the contraction is eccentric or concentric. Therefore, we propose that the ability to control movement is affected by the type of muscle contraction.
본원에서 수술 후 방사선치료를 수행한 하지 연부조직육종 환자에 대해 용적세기조절회전치료(VMAT), 세기조절방사선치료(IMRT), 3차원입체조영방사선치료(3D-CRT)의 세 가지 치료계획을 수립하여 치료계획용적(PTV)과 대퇴골에 전달되는 방사선량을 각각 비교하였다. 세 치료계획방법 모두 치료계획용적에 전달되는 방사선량은 큰 차이를 보이지 않았으나 용적세기조절회전치료와 세기조절방사선치료의 경우 3차원입체조영방사선치료보다 대퇴골에 전달되는 방사선량을 줄일 수 있었다. 또한 용적세기조절회전치료의 경우 세기조절방사선치료 보다 치료에 필요한 monitor unit이 적어 치료시간 감소의 효과가 나타났다. 따라서 하지 연부조직육종 방사선치료 시 용적세기조절회전치료의 사용은 효과적인 방사선치료를 수행할 수 있을 것이라 사료된다.
If the same weight is used in parallel opposed 6 and 10 MV x-ray beams, the lowest dose is achieved at SAD. Therefore, dose homogeneity in the target volume is decreased when SAD is taken at center of target volume than center of phantom or patient. With Standard deviation of ${\pm}6\%$ that repuesented the dose homogeneity in tarhet volume, we studied the optimized beam weights at which hot spot dose was least in parallel opposed beams. The optimized beam weights that maximally decrease the hot spot dose, wer 1.29, 1.19, 2.71, 3.50, and 4.70 in 6 MV x-ray and 1.25, 1.53, 1.90, 2.36, 3.01, and 3.7 in 10 MV x-ray, reapectively, when center of target volume was changed to 2,4,6,8,10, and 12cm from center plan of phantom along the centeral axis of beams.
Ornithine decarboxylase (ODC), the first enzyme in the polyamine biosynthesis, plays an important role in tumor progression, cell proliferation and differentiation. In recent years, ODC has been the subject of intense study among researchers, as a target for anti-cancer therapy and specific inhibitory agents, have the potential to suppress carcinogenesis and find applications in clinical therapy. In particular, it is suggested that ODC is a promising candidate target for natural products in cancer chemoprevention. Future exploration of ornithine decarboxyalse inhitors present in nature may offer great hope for finding new cancer chemporeventive agents.
양성자치료는 양성자의 물리적 특성으로 인해 인체 내의 특정범위에 모든 에너지를 전달하고 감쇠되어 타겟조직 뒤에 존재하는 정상조직에는 방사선이 조사되지 않는 큰 장점을 가진 치료법이다. 이 방법은 인체 내의 암 조직을 타겟으로 했을 때, 빔 방향에서의 타겟의 2차원적인 모양은 황동으로 제작된 블럭을 통해 정상조직에 들어가는 방사선을 차폐하고 마진을 주어서 GTV (eross Tumor Volume)에 90% 이상의 선량이 전달되도록 조절한다. 그리고, 양성자 빔의 날줄방향 (longitudinal)에서의 타겟의 3차원적인 모양을 고려하여 PMMA로 이루어진 보상체(compensator)를 밀링머신으로 조각하여 타겟에 방사선이 정확하게 분포되도록 한다. 이러한 보상체의 정확한 정도 관리를 위해 현재 사용되는 수동적인 방법을 보완하여 X선 영상으로 해당하는 보상체의 영상을 획득하여 이 영상을 기반으로 정도관리를 할 수 있는 방법을 제안하였고, 제안한 방법으로 보상체의 각각의 깎여진 평면의 모양과 두께를 정성적으로 비교 및 평가할 수 있었으며 두 영상의 차이가 80% 이상 맞는 것으로 확인되었다. 이를 바탕으로 영상을 이용한 정도관리 프로그램을 보완하여 추후 실제 양성자치료 정도관리에 사용될 예정이다.
The purpose of this work is acquiring some parameters of therapeutic heavy ion beams after penetrating a thick target. The experiments were performed using a pencil-like $\^$12/C beam of about 3 mm in diameter from NIRS-HIMAC, and the data were taken at several points of the target thickness for $\^$12/C beam of 290 MeV/u and 400 MeV/u. By the simultaneous measurements using some detectors, the atomic number of each fragment particle was identified, and the beam profile, the dose distribution and the LET spectrum for each element were derived.
Appropriate physical position and balance means giving the least stress and the most useful biomechanically to the body. As this fails, one would have functional recovery problem regardless of disability. There reported better effective on Dynamic training rather than Static training for a proper recovery of physical position, and additionally required Sensory Feedback. Those who have disability of balance, especially Central Nervous System lesion should he provided with variety of Sensory Feedback, and also Dynamic Balance training used by is quite effective.
목 적: 본 연구는 모양이 불규칙하고 손상위험장기(Organ At Risk, OAR)에 매우 인접한 타겟(Target)의 방사선 치료 시, 비동일평면상(Non-coplanar)의 빔(Beam)을 이용한 Fixed-field 세기변조 방사선치료(Intensity Modulated Radiation Therapy, IMRT)와 용적변조회전 방사선치료(Volumetric Modulated Arc Therapy, VMAT) 치료계획의 유용성을 평가 및 비교해 보고자 하였다. 대상 및 방법: 본원에서 True Beam STX(Varian Medical Systems, USA)를 이용하여 전체 두피(Whole Scalp), 부분적 두피(Partial Scalp), 그리고 전체 뇌실(Whole Ventricle)에 방사선 치료를 받은 환자 중 각 부위별로 2명 씩, 총 6명을 대상으로 하였다. VMAT 치료계획 시, Beamlet에 포함되는 OAR의 용적을 최소화하기 위해 Coplanar 또는 Non-coplanar 빔을 이용하였고, Fixed-field IMRT는 6명 모두 2개 이상의 카우치(Couch) 각도를 이용한 Non-coplanar IMRT(이하 ncIMRT)로 치료계획 하였다. 결 과: 양측 수정체, 양측 시신경, 시신경 교차, 그리고 뇌 줄기의 최대선량과 양측 안구와 해마의 평균선량을 측정하였고, 6명 모두 9개의 OAR 중 6개 이상에서 VMAT 치료계획이 ncIMRT보다 1.1배에서 8.2배가량 높은 선량 값을 나타내었다. 전체 두피와 부분적 두피의 치료 시, 20 Gy가 조사되는 뇌의 용적은 VMAT이 ncIMRT의 2배 이상이었고, 전체 뇌실의 치료 시에는 두 치료계획이 큰 차이를 보이지 않았다. 타겟 Coverage는 두 치료계획 모두 $PTV_{100%}=95%$를 만족시켰고, 타겟 내 최대선량과 치료 시 필요한 총 Monitor Unit(MU)은 ncIMRT가 VMAT보다 높았으며 두 치료계획 모두 임상적용을 위한 Gamma test 시행 결과, 2 mm/2 % 조건을 통과하였다. 결 론: 본 연구 결과, ncIMRT는 VMAT에 비해 치료 시 필요한 MU가 높아 치료시간과 장비의 로딩(Loading)을 증가시키므로 치료의 효율성은 다소 떨어지지만, VMAT과 비슷한 타겟 Coverage를 유지하면서, OAR의 선량은 훨씬 감소시키는 것을 알 수 있었다. 따라서 모양이 불규칙하고 OAR에 매우 인접해 있는 타겟의 방사선 치료 시에는 ncIMRT 치료계획을 고려해 볼 필요가 있다고 사료된다.
본 웹사이트에 게시된 이메일 주소가 전자우편 수집 프로그램이나
그 밖의 기술적 장치를 이용하여 무단으로 수집되는 것을 거부하며,
이를 위반시 정보통신망법에 의해 형사 처벌됨을 유념하시기 바랍니다.
[게시일 2004년 10월 1일]
이용약관
제 1 장 총칙
제 1 조 (목적)
이 이용약관은 KoreaScience 홈페이지(이하 “당 사이트”)에서 제공하는 인터넷 서비스(이하 '서비스')의 가입조건 및 이용에 관한 제반 사항과 기타 필요한 사항을 구체적으로 규정함을 목적으로 합니다.
제 2 조 (용어의 정의)
① "이용자"라 함은 당 사이트에 접속하여 이 약관에 따라 당 사이트가 제공하는 서비스를 받는 회원 및 비회원을
말합니다.
② "회원"이라 함은 서비스를 이용하기 위하여 당 사이트에 개인정보를 제공하여 아이디(ID)와 비밀번호를 부여
받은 자를 말합니다.
③ "회원 아이디(ID)"라 함은 회원의 식별 및 서비스 이용을 위하여 자신이 선정한 문자 및 숫자의 조합을
말합니다.
④ "비밀번호(패스워드)"라 함은 회원이 자신의 비밀보호를 위하여 선정한 문자 및 숫자의 조합을 말합니다.
제 3 조 (이용약관의 효력 및 변경)
① 이 약관은 당 사이트에 게시하거나 기타의 방법으로 회원에게 공지함으로써 효력이 발생합니다.
② 당 사이트는 이 약관을 개정할 경우에 적용일자 및 개정사유를 명시하여 현행 약관과 함께 당 사이트의
초기화면에 그 적용일자 7일 이전부터 적용일자 전일까지 공지합니다. 다만, 회원에게 불리하게 약관내용을
변경하는 경우에는 최소한 30일 이상의 사전 유예기간을 두고 공지합니다. 이 경우 당 사이트는 개정 전
내용과 개정 후 내용을 명확하게 비교하여 이용자가 알기 쉽도록 표시합니다.
제 4 조(약관 외 준칙)
① 이 약관은 당 사이트가 제공하는 서비스에 관한 이용안내와 함께 적용됩니다.
② 이 약관에 명시되지 아니한 사항은 관계법령의 규정이 적용됩니다.
제 2 장 이용계약의 체결
제 5 조 (이용계약의 성립 등)
① 이용계약은 이용고객이 당 사이트가 정한 약관에 「동의합니다」를 선택하고, 당 사이트가 정한
온라인신청양식을 작성하여 서비스 이용을 신청한 후, 당 사이트가 이를 승낙함으로써 성립합니다.
② 제1항의 승낙은 당 사이트가 제공하는 과학기술정보검색, 맞춤정보, 서지정보 등 다른 서비스의 이용승낙을
포함합니다.
제 6 조 (회원가입)
서비스를 이용하고자 하는 고객은 당 사이트에서 정한 회원가입양식에 개인정보를 기재하여 가입을 하여야 합니다.
제 7 조 (개인정보의 보호 및 사용)
당 사이트는 관계법령이 정하는 바에 따라 회원 등록정보를 포함한 회원의 개인정보를 보호하기 위해 노력합니다. 회원 개인정보의 보호 및 사용에 대해서는 관련법령 및 당 사이트의 개인정보 보호정책이 적용됩니다.
제 8 조 (이용 신청의 승낙과 제한)
① 당 사이트는 제6조의 규정에 의한 이용신청고객에 대하여 서비스 이용을 승낙합니다.
② 당 사이트는 아래사항에 해당하는 경우에 대해서 승낙하지 아니 합니다.
- 이용계약 신청서의 내용을 허위로 기재한 경우
- 기타 규정한 제반사항을 위반하며 신청하는 경우
제 9 조 (회원 ID 부여 및 변경 등)
① 당 사이트는 이용고객에 대하여 약관에 정하는 바에 따라 자신이 선정한 회원 ID를 부여합니다.
② 회원 ID는 원칙적으로 변경이 불가하며 부득이한 사유로 인하여 변경 하고자 하는 경우에는 해당 ID를
해지하고 재가입해야 합니다.
③ 기타 회원 개인정보 관리 및 변경 등에 관한 사항은 서비스별 안내에 정하는 바에 의합니다.
제 3 장 계약 당사자의 의무
제 10 조 (KISTI의 의무)
① 당 사이트는 이용고객이 희망한 서비스 제공 개시일에 특별한 사정이 없는 한 서비스를 이용할 수 있도록
하여야 합니다.
② 당 사이트는 개인정보 보호를 위해 보안시스템을 구축하며 개인정보 보호정책을 공시하고 준수합니다.
③ 당 사이트는 회원으로부터 제기되는 의견이나 불만이 정당하다고 객관적으로 인정될 경우에는 적절한 절차를
거쳐 즉시 처리하여야 합니다. 다만, 즉시 처리가 곤란한 경우는 회원에게 그 사유와 처리일정을 통보하여야
합니다.
제 11 조 (회원의 의무)
① 이용자는 회원가입 신청 또는 회원정보 변경 시 실명으로 모든 사항을 사실에 근거하여 작성하여야 하며,
허위 또는 타인의 정보를 등록할 경우 일체의 권리를 주장할 수 없습니다.
② 당 사이트가 관계법령 및 개인정보 보호정책에 의거하여 그 책임을 지는 경우를 제외하고 회원에게 부여된
ID의 비밀번호 관리소홀, 부정사용에 의하여 발생하는 모든 결과에 대한 책임은 회원에게 있습니다.
③ 회원은 당 사이트 및 제 3자의 지적 재산권을 침해해서는 안 됩니다.
제 4 장 서비스의 이용
제 12 조 (서비스 이용 시간)
① 서비스 이용은 당 사이트의 업무상 또는 기술상 특별한 지장이 없는 한 연중무휴, 1일 24시간 운영을
원칙으로 합니다. 단, 당 사이트는 시스템 정기점검, 증설 및 교체를 위해 당 사이트가 정한 날이나 시간에
서비스를 일시 중단할 수 있으며, 예정되어 있는 작업으로 인한 서비스 일시중단은 당 사이트 홈페이지를
통해 사전에 공지합니다.
② 당 사이트는 서비스를 특정범위로 분할하여 각 범위별로 이용가능시간을 별도로 지정할 수 있습니다. 다만
이 경우 그 내용을 공지합니다.
제 13 조 (홈페이지 저작권)
① NDSL에서 제공하는 모든 저작물의 저작권은 원저작자에게 있으며, KISTI는 복제/배포/전송권을 확보하고
있습니다.
② NDSL에서 제공하는 콘텐츠를 상업적 및 기타 영리목적으로 복제/배포/전송할 경우 사전에 KISTI의 허락을
받아야 합니다.
③ NDSL에서 제공하는 콘텐츠를 보도, 비평, 교육, 연구 등을 위하여 정당한 범위 안에서 공정한 관행에
합치되게 인용할 수 있습니다.
④ NDSL에서 제공하는 콘텐츠를 무단 복제, 전송, 배포 기타 저작권법에 위반되는 방법으로 이용할 경우
저작권법 제136조에 따라 5년 이하의 징역 또는 5천만 원 이하의 벌금에 처해질 수 있습니다.
제 14 조 (유료서비스)
① 당 사이트 및 협력기관이 정한 유료서비스(원문복사 등)는 별도로 정해진 바에 따르며, 변경사항은 시행 전에
당 사이트 홈페이지를 통하여 회원에게 공지합니다.
② 유료서비스를 이용하려는 회원은 정해진 요금체계에 따라 요금을 납부해야 합니다.
제 5 장 계약 해지 및 이용 제한
제 15 조 (계약 해지)
회원이 이용계약을 해지하고자 하는 때에는 [가입해지] 메뉴를 이용해 직접 해지해야 합니다.
제 16 조 (서비스 이용제한)
① 당 사이트는 회원이 서비스 이용내용에 있어서 본 약관 제 11조 내용을 위반하거나, 다음 각 호에 해당하는
경우 서비스 이용을 제한할 수 있습니다.
- 2년 이상 서비스를 이용한 적이 없는 경우
- 기타 정상적인 서비스 운영에 방해가 될 경우
② 상기 이용제한 규정에 따라 서비스를 이용하는 회원에게 서비스 이용에 대하여 별도 공지 없이 서비스 이용의
일시정지, 이용계약 해지 할 수 있습니다.
제 17 조 (전자우편주소 수집 금지)
회원은 전자우편주소 추출기 등을 이용하여 전자우편주소를 수집 또는 제3자에게 제공할 수 없습니다.
제 6 장 손해배상 및 기타사항
제 18 조 (손해배상)
당 사이트는 무료로 제공되는 서비스와 관련하여 회원에게 어떠한 손해가 발생하더라도 당 사이트가 고의 또는 과실로 인한 손해발생을 제외하고는 이에 대하여 책임을 부담하지 아니합니다.
제 19 조 (관할 법원)
서비스 이용으로 발생한 분쟁에 대해 소송이 제기되는 경우 민사 소송법상의 관할 법원에 제기합니다.
[부 칙]
1. (시행일) 이 약관은 2016년 9월 5일부터 적용되며, 종전 약관은 본 약관으로 대체되며, 개정된 약관의 적용일 이전 가입자도 개정된 약관의 적용을 받습니다.