• Title/Summary/Keyword: Tape Tension

Search Result 53, Processing Time 0.037 seconds

The analysis of the dynamic characteristics of the tension arm in tape transporting system (테이프 주행계 텐션암의 동특성해석)

  • Kim, Joong-Bae;Ryu, Doo-Hyun;Park, Young-Pil
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.2
    • /
    • pp.164-172
    • /
    • 1994
  • The purposes of the study are to formulate a mathematical model of mechanical tension arm system including supply reel and capstan system, and to simulate dynamic reponse according to parameter variations of the componests in tension arm system. Experiments were carried out in order to prove the validity of the mathematical model. From the results of simulations and experiments, dynamic responses of tape tension and displacement of tension post were analyzed during entire playing mode and they showed the basic characteristics of the tension arm system.

  • PDF

Preliminary investigation of Ic homogeneity along the longitudinal direction of YBCO coated conductor tape under tensile loading

  • Dizon, J.R.C.;Oh, S.S.;Sim, K.D.;Shin, H.S.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.15 no.2
    • /
    • pp.24-28
    • /
    • 2013
  • In this study, the homogeneity of critical current, $I_c$, along the lengthwise direction in the coated conductor (CC) tape under uniaxial tension was investigated using a multiple voltage tap configuration. Initially, a gradual and homogeneous $I_c$ degradation occurred in all subsections of the tape up to a certain strain value. This was followed by an abrupt $I_c$ degradation in some subsections, which caused scattering in $I_c$ values along the length with increasing tension strain. The $I_c$ degradation behaviour was also explained through n-value as well as microstructure analyses. Subsections showed $I_c$ scattering corresponding to damaged areas of the CC tape revealed that transverse cracks were distributed throughout the gauge length. This homogeneous $I_c$ degradation behaviour under tension is similar with the case under torsion strain but different with the case under hard bending which were previously reported. This behaviour is also different with the case using Bi-2223 HTS tapes under tension strain.

Evaluation of mechanical properties of Bi-2223/Ag HTS tapes (Bi-2223/Ag 고온초전도 선재의 기계적 특성 평가)

  • 하홍수;이동훈;양주생;최정규;윤진국;하동우;오상수;권영길
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2002.02a
    • /
    • pp.351-354
    • /
    • 2002
  • In most of electrical applications using Bi-2223/Ag HTS tapes, bending and tension stresses are essentially applied to the tape. Therefore, the critical current of the Bi-2223/Ag tape is degraded by increasing the deformation stress, though brittle superconducting filaments are embedded in the reinforced Ag alloy sheath. It is needed to understand bending and tension properties of HTS tapes at room temperature and cryogen to make superconducting magnet, cable and etc. using Bi-2223/Ag HTS tapes. Actually, bending and tension stress applied to the tapes simultaneously, when winding the tapes on former for applications. In this study, the effect of mechanical deformations, bending and tension, on the critical current of Bi-2223/Ag tape was investigated.

  • PDF

The Effect of Deformation Stress-strain and Temperature on the $I_c$ Degradation of Bi-2223/Ag Tapes

  • Ha, Hong-Soo;Kim, Sang-Cheol;Ha, Dong-Woo;Oh, Sang-Soo;Joo, Jin-Ho
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09b
    • /
    • pp.1251-1252
    • /
    • 2006
  • In order to investigate 95% retained critical current of Bi-2223/Ag tapes under various stress-strain conditions, load cell attached tension and bending apparatus was used. The critical current of stress-strained tape was degraded below 95% retained critical current when tension and bending was simultaneously applied together. But only one of this tension or bending did not degrade the tape below 95% retained critical current. Deformation temperature was important to maintain the 95% retained Ic of Bi-2223/Ag tapes after bending or tension deformation because mechanical strength of tapes can be changed drastically between room temperature and 77 K.

  • PDF

Review on the Vibration Problems in VTR Transporting Mechanisms (VTR (VCR,DAT) 주행계 진동문제의 고찰)

  • 김중배;박남수;이상조;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1990.10a
    • /
    • pp.181-185
    • /
    • 1990
  • In the present study, the following factors are analyzed systematically using the theoretical and experimental methods, which have the significant influence on the quality of VTR tape path system in order to develope the high performance and quality in VTR mechanism: 1) Vibration characteristics of the deck including the tape path sytem, 2) Modeling the global tape path, 3) Torsional vibration of the VTR drum. 4) Capstan system, 5) Tension bar, 6) Stick-slip phenomenon of the running tape.

  • PDF

Flying Characteristics of Running Tape above Rotating Head (I) (회전헤드에 대한 주행테이프의 부상특성 ( I ))

  • 민옥기;김수경
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.15 no.2
    • /
    • pp.523-536
    • /
    • 1991
  • This dissertation analyzes the running mechanism of flexible and thin tape above rotating head through the numerical simulation and the experiment. The scope of analysis is confined to the phenomena of two dimensional elasto hydrodynamic lubrication between the protruded bump on a rotating cylinder and the running tape. This model is based on the elastic deformation equation of plate and shell and Reynolds equation. Finite difference method is employed as a numerical technique to calculate (1) the distribution of pressure between the running tape and rotating bump and (2) the vertical deformation of elastic thin tape over he rotating bump under hydrodynamic pressure. In numerical analyses, the effects of bump size on flying characteristics of the tape were evaluated and examined considering the influence of tension and stiffness of tape.

Effect of tension difference of kinesio tape applied to the tibialis anterior muscle on muscle strength, joint range of motion, and balance of the ankle joint in young college students (키네시오 테이프의 장력 차이가 젊은 대학생들의 발목 근력, 관절가동범위 및 균형에 미치는 영향)

  • Lee, Dae Hoon;Kim, Cho In;Shin, Gi Ha;Yeom, Yoo Jin;Kim, Ji Sung;Kim, Seong Ho
    • Journal of Korean Physical Therapy Science
    • /
    • v.29 no.2
    • /
    • pp.28-37
    • /
    • 2022
  • Background: The purpose of this study was to investigate the effects of differences in the tension of Kinesio tape applied to the tibialis anterior muscle on muscle strength, joint range of motion and balance of ankle joint in young adults. Design: Randomized Controlled Trial. Methods: 41 young college students participated in this study. And the subjects were allocated randomly to two group. The experimental group had a tension difference (10%G, n=20). And there was no difference in tension in the control group (0%G, n=21). Jtech power track II, goniometer, and Biorescue were used to measure muscle strength, joint range of motion and balance. The paired t-test was performed to examine the differences within the groups before and after taping, and the independent t-test was performed to examine the differences between the groups. Result: 1) As a result of measuring muscle strength of each group, all measurements except 0%G of plantar flexion showed insignificant results. 2) Measurement of joint range of motion each group showed that neither 0%G nor 10%G was significant. 3) As a result of measuring the baladncing ability of each group there was a significant decrease in length, and average speed of the balancing capability (p<.05). 4) Comparisons between groups showed significant differences in the area among balance capability (p<.05). Conclusions: Based on these findings, the tension difference of Kinesio tape applied to the tibialis anterior muscle shows little effect on the muscle strength, range of motion, and balance of ankle joints. Given the current lack of research on the tension of kinesio tapes many studies are needed in the future to establish clear theories.

Preparation of PZI Tapes by Solvent Washing Dry Method (용매세척건조법에 의한 PZT 테입 제조)

  • 신효순;윤석진;김현재
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.300-303
    • /
    • 1999
  • For the fast dry of the aqueous tape, the process which water was replaced by organic solvent was proposed. So-called, it was the solvent washing dry, Three organic solvents (methanol, ethanol, and acetone) were selected for the washing solvent. The weight loss of the washed tapes was measured to evaluate the dry rate of the tapes and dried tapes were examined the generation of the cracks with the variations of the organic solvent and the washing time. Methanol, ethanol, and acetone were all available organic solvents for this method. The tapes washed in methanol, ethanol, and acetone were dried rapidly for twenty minutes. After thirty minutes, the weight losses were not any more. The solvent of the lower surface tension can decreases the crack of dried tape. If solvent substitutes water completely, though it was fast dried, crack can be eliminated. The tape casting system was designed for the solvent washing dry and prepared. An homogeneous tape was established by continuous tape casting process.

  • PDF

Effect of Tensile Strain on $I_c$ Degradation Characteristics In Bent Externally Reinforced Bi-2223 Superconducting Tapes (굽힘상태의 외부보강한 Bi-2223 초전도테이프에서 임계전류 열화특성에 미치는 인장변형률의 영향)

  • 신형섭;김기현;오상수;하동우
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.6-11
    • /
    • 2004
  • The influences of mixed strain mode of bending-tension on the critical current. Ic in externally reinforced Bi-2223 tapes and their interaction were investigated in this study. A test fixture which providing a mixed deformation mode of bending-tension to HTS tapes has been newly devised. When the total strain induced in the tape in the mixed strain mode was expressed by the superposition of the bending and tensile strains the irreversible strain for the critical current degradation of Bi-2223 tapes increased, as compared with the simple bending mode case. The $I_c$ degradation at the region exceeding the irreversible strain showed a medium between the simple bending case and the simple tension case. As the initial bending strain imparted increased , namely as the diameter of mandrel adopted decreased. the apparent irreversible strain in Bi-2223 tapes increased . but the increment became smaller As a result. it can be found that the tension to be applied to bent Bi-2223 tapes during cabling should be smaller. as the mandrel diameter becomes smaller.

Performance evaluation of differently structured RCE-DR GdBCO coated conductor tapes under uniaxial tension at 77 K

  • Diaz, Mark Angelo E.;Shin, Hyung-Seop;Jung, Ho-Sang;Lee, Jaehun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.24 no.1
    • /
    • pp.13-17
    • /
    • 2022
  • The mechanical properties of REBCO coated conductor (CC) tapes under uniaxial tension are mainly determined by the thick layer Components like the substrate and the stabilizer. Depending on the applications of the CC tapes, it is also needed to externally reinforce thin metallic foils to one side or both sides of the CC tapes. This study investigated the effect of additional stabilizer layers or lamination on the electrical resistivity and electromechanical properties in RCE-DR processed GdBCO CC tapes with different structures. The strain/stress tolerance of Ic in differently processed 12 mm-wide REBCO CC tapes under uniaxial tension at 77 K and self-field could be determined by the loading-unloading scheme. As a result, Sn-Cu stabilized CC tape showed a significant decrease in mechanical properties due to its soft but thick stabilizing layer. However, similar electromechanical properties have been observed on both Sn-Cu and Sn-stabilized CC tapes, the Ic degradation behavior was independent of whether the CC tape has an external reinforcement or different stabilizing layers.