• 제목/요약/키워드: Ta-Ti

검색결과 416건 처리시간 0.023초

Ta 함량에 따른 Ti-xTa 합금의 부식특성 (Corrosion Characteristics of Ti-xTa Alloys with Ta contents)

  • 김현주;최한철
    • Corrosion Science and Technology
    • /
    • 제12권1호
    • /
    • pp.50-55
    • /
    • 2013
  • The purpose of this study was to investigate corrosion characteristics of Ti-xTa alloys with Ta contents. Ti-xTa alloys used as samples (x=30, 40%) were arc-melted under argon atmosphere of 99.9% purity. Ti-xTa alloys were homogenized for 12hr at $1000^{\circ}C$ and then water quenched. The surface characteristics of Ti-xTa alloys were investigated using optical microscopy (OM) and X-ray diffractometer (XRD). The anodic corrosion behaviors of the specimens were examined through potentiodynamic, potentiostatic and galvanostatic test in 0.9 % NaCl solution at $36.5{\pm}1^{\circ}C$. After corrosion test, the surface characteristics of Ti-xTa alloys were investigated using OM. The microstructure of Ti-Ta alloy showed the beta structure with Ta content. The corrosion resistance of Ti alloy was improved by increasing Ta content and the corrosion morphology of Ti-Ta alloy showed that the site attacked by chloride ion decreased from the active to passive region with Ta content. Potential of Ti-40Ta alloy increased as time increased, whereas, current density of Ti-40Ta alloy decreased as time increased compared to Ti-30 alloy.

Cell response to a newly developed Ti-10Ta-10Nb alloy and its sputtered nanoscale coating

  • Kim, Young-Min;Vang, Mong-Sook;Yang, Hong-So;Park, Sang-Won;Lim, Hyun-Pil
    • The Journal of Advanced Prosthodontics
    • /
    • 제1권1호
    • /
    • pp.56-61
    • /
    • 2009
  • STATEMENT OF PROBLEM. The success of titanium implants is due to osseointegration or the direct contact of the implant surface and bone without a fibrous connective tissue interface. PURPOSE. The purpose of this study was to evaluate the osteoblast precursor response to titanium-10 tantalum-10 niobium(Ti-Ta-Nb) alloy and its sputtered coating. MATERIAL AND METHODS. Ti-Ta-Nb coatings were sputtered onto the Ti-Ta-Nb disks. Ti6-Al-4V alloy disks were used as controls. An osteoblast precursor cell line, were used to evaluate the cell responses to the 3 groups. Cell attachment was measured using coulter counter and the cell morphology during attachment period was observed using fluorescent microscopy. Cell culture was performed at 4, 8, 12 and 16 days. RESULTS. The sputtered Ti-Ta-Nb coatings consisted of dense nanoscale grains in the range of 30 to 100 nm with alpha-Ti crystal structure. The Ti-Ta-Nb disks and its sputtered nanoscale coatings exhibited greater hydrophilicity and rougher surfaces compared to the Ti-6Al-4V disks. The sputtered nanoscale Ti-Ta-Nb coatings exhibited significantly greater cell attachment compared to Ti-6Al-4V and Ti-Ta-Nb disks. Nanoscale Ti-Ta-Nb coatings exhibited significantly greater ALP specific activity and total protein production compared to the other 2 groups CONCLUSIONS. It was concluded that nanoscale Ti-Ta-Nb coatings enhance cell adhesion. In addition, Ti-Ta-Nb alloy and its nanoscale coatings enhanced osteoblast differentiation, but did not support osteoblast precursor proliferation compared to Ti-6Al-4V. These results indicate that the new developed Ti-Ta-Nb alloy and its nanoscale Ti-Ta-Nb coatings may be useful as an implant material.

동시스퍼터법에 의한 Ta 도핑된 $TiO_2$ 박박 합성과 광전극 특성 (Preparation of Ta-doped $TiO_2$ thin rums by co-sputtering and their photo-electrode properties)

  • 윤종원
    • 한국결정성장학회지
    • /
    • 제18권4호
    • /
    • pp.165-168
    • /
    • 2008
  • 동시스퍼터법을 이용하여 Ta이 도핑된 $TiO_2$ 박막을 석영 및 ITO 기판위에 제작하였다. Ta의 도핑량은 동시스퍼터법에 의하여 조절되는 Ta 금속선 길이에 의하여 제어 되었다. Ta이 도핑된 $TiO_2$ 박막은 rutile상에서 anatase상으로 구조변화를 유발 시키며 고용체를 형성했다. Ta의 도핑량이 증가함에 따라 rutile상 보다는 anatase상이 많은 것으로 나타났다. XPS 분석에 따르면 도핑된 Ta은 금속이 아닌 $Ta_2O_5$의 산화물을 형성하는 것으로 나타났다. Ta이 도핑된 $TiO_2$ 전극에서는 자외선(UV) 영역을 포함하여 가시광(VIS) 영역의 빛의 조사에 광전류응답 특성을 발현하였다. 가시광선 영역에서 발현된 광전류 응답 특성은 Ta 도핑에 의하여 $TiO_2$ 밴드갭내에 불순물 준위의 형성에 기인한 것으로 사료된다.

NMOS 소자의 Ta-Ti 게이트 전극 특성 (Characteristics of Ta-Ti Gate Electrode for NMOS Device)

  • 강영섭;서현상;노영진;이충근;홍신남
    • 한국항행학회논문지
    • /
    • 제7권2호
    • /
    • pp.211-216
    • /
    • 2003
  • 본 논문에서는 오래 전부터 NMOS의 게이트 전극으로 사용된 폴리실리콘을 대체할 수 있는 Ta-Ti 합금의 특성에 대해 연구하였다. 실리콘 기판 위에 열적으로 성장된 $SiO_2$ 위에 Ta과 Ti의 두 타깃을 사용하여 co-sputterring 방법으로 Ta-Ti 합금을 증착하였다. 각각의 타깃은 100W의 sputtering power로 증착하여 시편을 제작하였다. 또한 비교 분석을 위하여 Ta을 100W의 sputtering power로 증착한 시편도 제작하였다. 제작된 Ta-Ti 합금 게이트의 열적/화학적 안정성을 검토하기 위하여 $600^{\circ}C$에서 급속열처리를 수행한 결과 소자의 성능 저하는 나타나지 않았다. 또한 전기적 특성 분석 결과 Ta-Ti 합금은 NMOS에 적합한 일함수인 4.13eV를 산출해 낼 수 있었고, 면저항 역시 폴리실리콘에 비해 낮은 값을 얻을 수 있었다.

  • PDF

Cu/Ti(Ta)/NiSi 접촉의 열적안정성에 관한 연구 (A Study on the Thermal Stability of Cu/Ti(Ta)/NiSi Contacts)

  • 유정주;배규식
    • 한국재료학회지
    • /
    • 제16권10호
    • /
    • pp.614-618
    • /
    • 2006
  • The thermal stability of Cu/Ti(or Ta)/NiSi contacts was investigated. Ti(Ta)-capping layers deposited to form NiSi was utilized as the Cu diffusion barrier. Ti(Ta)/NiSi contacts was thermally stable upto $600^{\circ}C$. However when Cu/Ti(Ta)/NiSi contacts were furnace-annealed at $300{\sim}400^{\circ}C$ for 40 min., the Cu diffusion was found to be effectively suppressed, but NiSi was dissociated and then Ni diffused into the Cu layer to form Cu-Ni solutions. On the other hand, the Ni diffusion did not occur for the Al/Ti/NiSi system. The thermal instability of Cu/Ti(Ta)/NiSi contacts was attributed to the high heat of solution of Ni in Cu.

Chemical Design of Highly Water-Soluble Ti, Nb and Ta Precursors for Multi-Component Oxides

  • Masato Kakihana;Judith Szanics;Masaru Tada
    • Bulletin of the Korean Chemical Society
    • /
    • 제20권8호
    • /
    • pp.893-896
    • /
    • 1999
  • Novel citric acid based Ti, Nb and Ta precursors that are highly stable in the presence of water were developed. No alkoxides of Ti, Nb and Ta were utilized in the preparation, instead much less moisture-sensitive metallic Ti, NbCl5 and TaCl5 were chosen as starting chemicals for Ti, Nb and Ta, respectively. The feasibility of these chemicals as precursors is demonstrated in the powder synthesis of BaTi4O9, Y3NbO7 and LiTaO3. The water-resistant Ti precursor was employed as a new source of water-soluble Ti in the amorphous citrate method, and phase pure BaTi4O9 in powdered form was successfully synthesized at 800 ?. The Pechini-type polymerizable complex method using the water-resistant Nb and Ta precursors was applied to the synthesis of Y3NbO7 and LiTaO3, and both the powder materials in their pure form were successfully synthesized at reduced tempera-tures, viz. 500-700 ?. The remarkable retardation of hydrolysis of these water-resistant precursors is explained in terms of the partial charge model theory.

Ti-Ta-Zr합금의 전기화학적 특성에 미치는 HA/TiN 코팅의 영향 (Effects of HA/TiN Coating on the Electrochemical Characteristics of Ti-Ta-Zr Alloys)

  • 오미영;김원기;최한철
    • 대한금속재료학회지
    • /
    • 제46권10호
    • /
    • pp.691-699
    • /
    • 2008
  • Electrochemical characteristics of Ti-30Ta-xZr alloys coated with HA/TiN by using magnetron sputtering method were studied. The Ti-30Ta containing Zr(3, 7, 10 and 15wt%) were 10 times melted to improve chemical homogeneity by using a vacuum furnace and then homogenized for 24hrs at $1000^{\circ}C$. The specimens were cut and polished for corrosion test and coating, and then coated with HA/TiN, respectively, by using DC and RF-magnetron sputtering method. The analyses of coated surface and coated layer were carried out by using optical microscope(OM), field emission scanning electron microscope(FE-SEM) and X-ray diffractometer(XRD). The electrochemical characteristics were examined using potentiodynamic (-1,500 mV~ + 2,000 mV) and A.C. impedance spectroscopy(100 kHz ~ 10 mHz) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The microstructure of homogenized Ti-30Ta-xZr alloys showed needle-like structure. In case of homogenized Ti-30Ta-xZr alloys, a-peak was increased with increasing Zr content. The thickness of TiN and HA coated layer showed 400 nm and 100 nm, respectively. The corrosion resistance of HA/TiN-coated Ti-30Ta-xZr alloys were higher than that of the non-coated Ti-30TaxZr alloys, whic hindicate better protective effect. The polarization resistance($R_p$) value of HA/TiN coated Ti-30Ta-xZr alloys showed $8.40{\times}10^5{\Omega}cm^2$ which was higher than that of non-coated Ti-30Ta-xZr alloys.

Ti 합금의 피로 특성 고찰 (Study for Fatigue Crack Propagation Behavior of Ti-alloy)

  • 정화일;조규종
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.786-789
    • /
    • 1997
  • Ti-6Al-4V has been used widely in biomedical field. But because of its toxicity, the ${\beta}$ stabilizing element, V, in Ti-6Al-4V has been replaced by Nb, Ta. Ti-10Ta-10Nb has been developed for biomedical applications. The fatigue crack propagation behavior of Ti-alloy(Ti-10Ta-10Nb) was investigated, in comparison with that of pure Ti. In order to better understand the fundamental fatigue behavior of Ti-10Ta-10Nb, rotating bending fatigue tests have been carried out. Ti-10Ta-10Nb has a better fatigue strength than pure Ti. In this paper, fatigue life has been predicted with Nisitani's equation of the fatigue crack propagation that can be established by measuring fatigue crack growth rates.

  • PDF

Ti-8Ta-3Nb 합금의 표면처리에 의한 백서 두개관 세포의 반응 (Biological response of primary rat calvarial cell by surface treatment of Ti-8Ta-8Nb alloy)

  • 김해진;손미경;박지일;정현주;김영준
    • Journal of Periodontal and Implant Science
    • /
    • 제38권4호
    • /
    • pp.595-602
    • /
    • 2008
  • Purpose: Ti-6Al-4V alloy is widely used as an implant material because of its good biocompatibility and good mechanical property compared with commercial pure titanium. Otherwise, toxicity of aluminum and vanadium in vivo has been reported. Ti-8Ta-3Nb alloy is recently developed in the R&D Center for Ti and Special Alloys and it was reported that this alloy has high mechanical strength, no cytotoxicity and similar biocompatibility to commercial pure titanium, but many studies are needed for its clinical use. In these experiment, we carried out different surface treatment on each Ti-8Ta-3Nb alloy disks, then cultured cell on it and assessed biological response. Materials and Methods: cpTi, Ti-6Al-4V, Ti-8Ta-3Nb alloy disks were prepared and carried out sandblasting and acid etching (SLA) or alkali-heat treatment (AH) on the Ti-8Ta-3Nb alloy disks. We cultured primary rat calvarial cells on each surface and assessed early cell attachment and proliferation by scanning electron microscopy, cell proliferation, alkaline phosphatase activity. Result: The rates of cell proliferation on the cpTi, Ti-8Ta-3Nb AH disks were higher than others (p<0.05) and alkaline phosphatase activity was significantly enhanced on the Ti-STa-8Nb AH disks(p<0.05). Conclusion: Most favorable cell response was shown on the Ti-8Ta-3Nb AH surfaces. It is supposed that alkali-heat treatment of the Ti-8Ta-3Nb alloy could be induced earlier bone healing and osseointegration than smooth surface.

Co-Cr(-Ta) 층의 결정성 및 자기적 특성에 미치는 하지층 효과 (Underlayer effects on crystallographic and magnetic characteristics of Co-Cr(-Ta) layer)

  • 금민종;공석현;가출현;손인환;김경환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.208-211
    • /
    • 2000
  • We prepared Co-Cr-Ta and Co-Cr-Ta/Ti thin film for perpendicular magnetic recording media by facing targets sputtering system (FTS system). Ti underlayer effects on crystallographic and magnetic characteristics of Co-Cr-Ta perpendicular magnetic recording media have been investigated. Crystallgraphic and magnetic characteristic of prepared thin films were evaluated by x-ray diffractometry(XRD), vibrating sample magnetometer(VSM) and kerr hysteresis loop measurement. The coercivity and anisotropy field increase by introduced Ti underlayer when substrate temperature is higher than 150$^{\circ}C$. The c-axis dispersion angle and grain size of Co-Cr-Ta/Ti thin film is decrease than Co-Cr-Ta when substrate temperature is higher than 100$^{\circ}C$. Consequently, the use of a Ti underlayer highly orientated can be improved crystallographic and magnetic characteristics of Co-Cr -Ta perpendicular media layer.

  • PDF