• Title/Summary/Keyword: TVOC

Search Result 153, Processing Time 0.023 seconds

A Study on the Emission Characteristics of Gaseous Organic Contaminants from Building Materials and Newly Constructed Apartments (신축 공동주택 및 건축자재에서의 오염물질 방출 특성)

  • Kim Yun-Deok;Lee Yun-Gyu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.18 no.7
    • /
    • pp.563-570
    • /
    • 2006
  • We investigated the emission characteristics of gaseous organic contaminants from building materials and newly constructed apartments. The emission test for building materials was done with small chamber method, and field measurements in newly constructed apartment were carried out by Korea Standard Test Method for Indoor Air Quality. First, the emission test by small chamber showed that the TVOC emission from building materials was much higher than formaldehyde. On the other hand, as expected, considerably high concentration of both TVOC and HCHO was detected in the new apartment.

A Study on the Discharge of Volatile Organic Compounds in Indoor Air of Newly-constructed Apartment Houses

  • Ryu, Jung-Min;Jang, Seong-Ki;Yang, Won-Ho;Cho, Tae-Jin;Son, Bu-Soon
    • Journal of Environmental Science International
    • /
    • v.18 no.5
    • /
    • pp.479-487
    • /
    • 2009
  • Because of the building is made airtight, Indoor Air Quality(IAQ) is go from bad to worse. There are many source of indoor pollution in any home. These include irritation of the eyes, nose, and throat, headaches, dizziness, and fatigue. Such immediate effects are usually short-term and treatable. In this study was measured and analyzed VOCs exposure levels and characteristic of Indoor air pollutant from new apartments in Korea. VOCs were measured indoor pre-residential and residential in new apartment and analyzed GC/MS. The concentration levels of indoor respirable TVOC were found to be higher than those of outdoor TVOC for new apartments. Before occupation, the average indoor and outdoor concentrations were 1498.61 $ug/m^3$ and 468.38 $ug/m^3$, respectively. After being occupied, the average indoor and outdoor concentration were 847.04 $ug/m^3$ and 102.84, respectively. The concentrations of TVOC in new apartments before occupation were shown in the order of Toluene(328.12 $ug/m^3$) > m,p-Xylene(163.67 $ug/m^3$) > Ethy1benzene(80.70 $ug/m^3$>o-XYlene (67.04$ug/m^3$). In addition, the TVOCs concentrations after occupation were also found in the order of Toluene (272.28 $ug/m^3$) > m.p-Xylene(121.79 $ug/m^3$) > Ethylbenzene(53.92 $ug/m^3$)>O-Xylene(24.94 $ug/m^3$). As a result, the concentrations of VOCs in new apartment houses were shown to be affected by indoor environment according activity patterns. So new apartments need to be controled in indoor air quality so that the residents can have more comfortable and healthier living environment.

The Actual State of the Indoor Environment in the Elderly Hall at Apartment Complexes during Winter (아파트단지 경로당의 겨울철 실내환경 실태)

  • Choi, Yoon-Jung;Yang, Hyun-Ju;Yang, Eun-Seok;Kim, Seon-Hui;Jeon, Eun-Sun
    • Korean Journal of Human Ecology
    • /
    • v.20 no.1
    • /
    • pp.225-241
    • /
    • 2011
  • The purposes of this study were to determine the actual state of the indoor environment, and to analyze the relationship between the architectural or living factors and indoor physical elements in the elderly hall at apartment complexes during winter. The field surveys consisted of measurements of the physical elements, observations of living factors, and interviews with users. The field surveys were carried out at 5 halls in February 2009. The measured elements were air temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, and illumination. The results showed that the averages of indoor temperature for the hall was between $22.7{\sim}25.1^{\circ}C$, relative humidity was 22.0~48.2%, $CO_2$ level was 892.4~2066.7ppm, CO level were 0~0.4ppm, PM10 level were $22.3{\sim}31.4{\mu}g/m^3$, HCHO level was 0.00~0.24ppm, and illumination level was 94~391.6lux. TVOC level was detected at 0.00~0.54ppm in only one hall. The average clothing amount of the users was 1.18clo and activity was 0.7~1.6met. It was evaluated to be a comfortable state at indoor temperature, CO level, PM10 level, and TVOC level, but an uncomfortable state at relative humidity, $CO_2$ level, HCHO level, and illumination level. The main reason seemed to be lack of ventilation.

Seasonal impact to air qualities in industrial areas of the Arabian Gulf region

  • Al-Taani, Ahmed A.;Howari, Fares M.;Nazzal, Yousef;Yousef, Ahmad
    • Environmental Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.143-149
    • /
    • 2018
  • Air quality conditions and pollution status have been evaluated in the industrial area between Sharjah and Ajman border in UAE. Daily concentrations of $O_3$, CO, $NO_2$, $SO_2$, $PM_{2.5}$, $PM_{10}$, Total Volatile Organic Compounds (TVOC) and Total Suspended Particulate (TSP) have been monitored from Sept. 2015 to April 2016. The monthly average concentrations of $O_3$, CO, $NO_2$, $SO_2$, TVOC were within the UAE ambient air quality standards during the survey period. However, $PM_{10}$ and TSP levels exceeded the recommended limits in Sept. 2015, Oct. 2015 and March 2016. Temporal variations in air quality parameters showed highest levels in March 2016 for $PM_{2.5}$, $PM_{10}$, $NO_2$, TVOC and TSP, whereas $O_3$, $SO_2$ and CO showed relatively low values in this month. $PM_{2.5}$ levels in ambient air were above the EPA guideline of $35{\mu}g/m^3$ in all months. $PM_{2.5}$ was the critical ambient air pollutant with Index for Pollutant ($I_p$) values varying from 103-209, indicating Air Quality Index categories of unhealthy for sensitive groups (62.5%) to unhealthy (25%) to very unhealthy (12.5%). The $I_p$ average values of $PM_{2.5}$ decreased from Sept. 2015 to reach lowest value in Dec. 2015 before increasing gradually, peaking in March 2016. These results suggest the potential health risks associated with $PM_{2.5}$ is low in winter, where the prevailing meteorological conditions of lower temperatures, higher humidity, higher wind speed reduced particulate matter. The results revealed the industrial area is impacted by anthropogenic and natural sources of particulate matter.

A Prediction Model for TVOC and HCHO Emission of Paint Materials (페인트에서 방출되는 TVOC 및 HCHO 방출량 예측모델)

  • Kim, Hyung-Soo;Lee, Kyung-Hoi
    • KIEAE Journal
    • /
    • v.3 no.1
    • /
    • pp.13-20
    • /
    • 2003
  • It is highly recognized that there is need for protection against indoor air pollution, as we realize environmental pollution is growing, For example, in an indoor environment, a person spends more than 80 percent of their time inside the building. Thus, concern about indoor decoration materials is growing, since they cause pollution in the rooms of an apartment, as well as in offices. As the indoor decoration materials become more diverse and lusurious, so the effect of VOCs(Volatile Organic Compounds) and HCHO(Formaldehy) is growing. The indoor decoration materials cause the Sick Building Syndrome, such as headaches, dizziness, or lack of concentraion, and they in turn cause serious deterioration in people's health. In this study, I probed the status of the indoor air pollution and carried on an investigation and analysis about the prevention technique. In doing so, I performed experimental tests and an assessment of the indoor decoration materials of an apartment. I also examined elements of the emitted and the emission. Finally, I examined the character of emissions, by changing environmental conditions, such as the temperature, humidity, and ventilation. With respect to VOCs tests, I applied the method of solid state adsorption using the adsorptive tube, based on the measurement of the American EPA TO-17, ASTM 5116-97, and the measurement of the Japanese Wall Decoration Industrial Association. The tested sample was analyzed by High Performance Liquid Chromatography, after going through the process of dissolvent extraction. As subjects of the test, Paint were selected. The process of this test is as follows; first, I figured out the character of the emission, by measuring the emitted concentration of VOCs and HOHC from the indoor decoration materials of an apartment. Second, I made a small-scale chamber and the test was processed in the chamber in order to suggest an environment-friendly prediction modlel development.

BTX Treatment of a Petrochemical Plant by Sliding Arc Plasma (Sliding Arc Plasma를 이용한 석유공장에서의 BTX 처리효율에 관한 연구)

  • Kwon, Woo-Taeg;Kwon, Lee-Seung;Lee, Woo-Sik
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.65-70
    • /
    • 2015
  • This research examines the removal efficiency of benzene, toluene, xylene (BTX) and total volatile organic compounds (TVOCs) by flowing VOCs, which are generated at a petrochemical complex in the Ulsan area, in a sliding arc plasma (SAP) reactor. The SAP reactor process is composed of 5 steps and the analysis was conducted using a BTX detector and TVOC measuring instrument. The removal efficiency of BTX was better at high concentration than at low concentration and the emitted TVOC concentration increased in later steps of the reactor. In addition, the removal efficiency improved, as the flow velocity increased. The maximum permissible concentration of TVOCs in the first step was about 481 ppm and showed over 94.83% efficiency when it was operated in the 2nd step at concentrations beyond 481 ppm. Therefore, there are many factors for improving the removal efficiency of SAP reactors at low concentration and measures should be prepared according to the application method for the various types of industrial reactors.