• Title/Summary/Keyword: TSS Removal

Search Result 115, Processing Time 0.026 seconds

Performance of Three Different Biofilter Media in Laboratory-Scale Recirculating Systems for Red Seabream Pagrus major Culture

  • Harwanto, Dicky;Oh, Sung-Yong;Park, Heung-Sik;Jo, Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.371-378
    • /
    • 2011
  • Juvenile red seabream (mean body weight 29.0 g) were reared in recirculating culture systems with three different biofilter media, sand (SF), polystyrene microbeads (PF), and Kaldnes beads (KF). The efficiencies of the three different biofilter media were also tested. The SF was fluidized, and the PF and KF were trickled. All treatments were duplicated. The volumetric removal rates of total ammonia nitrogen by SF, PF, and KF were 193.8, 183.9, and 142.6 g $m^{-3}day^{-1}$, respectively, and those of nitrite nitrogen ($NO_2$-N) were 113.4, 105.9, and 85.8 g $m^{-3}day^{-1}$, respectively. The TAN and $NO_2$-N removal rates of KF were lower than those of SF and PF (P < 0.05), but there was no significant difference in these rates between SF and PF (P > 0.05). Among the biofilters used, only KF showed total suspended solid (TSS) removal capacity. The TSS removal efficiencies of SF and PF were negative. The growth rates of fish in SF were significantly higher than those in KF but not higher than those in PF. There was no difference in growth rate between fish in PF and KF. The specific growth rate and feed conversion efficiency of red seabreams in KF were lower than those in SF and PF, but there were no significant differences between SF and PF. These results indicate that sand and polystyrene microbeads are recommended for red seabream culture in a recirculating system.

Deduction of Optimum Factors for Hydrogen Production from Organic Resources using a Continuous Reaction Process (연속반응공정을 이용한 유기성자원으로부터 수소생산을 위한 최적인자도출에 관한 연구)

  • Kim, Choong Gon;Shin, Hyun Gon
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.19 no.2
    • /
    • pp.22-27
    • /
    • 2011
  • This study was performed to find out the optimum condition for hydrogen production by changing mixture ratio from 3:7(food waste water : swine wastewater) without pre-treatment of food wastewater and swine wastewater using a continuous reaction process. It was confirmed that hydrogen generation according to pH is the highest in a condition of pH 5.5, and that the optimum pH for hydrogen production in case of mixing food wastewater with swine wastewater is 5.5 through this. Hydrogen generation according to HRT showed high hydrogen generation rate in case of 4 days rather than 3 days, and this involves largely in vitality of hydrogen producing bacteria according to variation of the HRT value, so it is judged that HRT also acts as an important factor to hydrogen producing bacteria. The organic removal efficiency recorded a removal efficiency of maximum TS 52%, VS 71%, TSS 83% and VSS 89% at the 6th day of operation, and it was confirmed that organic removal efficiency is possible even through an hydrogen production process.

The Effects of HRT, MLSS and DO on Nitrogen Removal Efficiency in MBR Process with Internal Baffle (내부 Baffle을 설치한 MBR 공정에서 HRT와 MLSS농도, DO농도 변화가 질소제거 효율에 미치는 영향)

  • Whang, Gye-Dae;Park, Joo-Young
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.5
    • /
    • pp.527-537
    • /
    • 2009
  • Three sets of parallel MBRs (reactor No.1, reactor No.2, reactor No.3) maintaining an MLSS of 4,000 mg/L, 6,000 mg/L and 8,000 mg/L, respectively, were operated to investigate the effect of various HRTs and DO concentration of MBRs on the removal efficiency of organic matters and nitrogen. The HRTs were operated on 4 hr, 6 hr, 8 hr. DO concentrations were ranged 1.5~2.0 mg/L and 0.5~1.0 mg/L respectively on each HRT conditions. MBR was divided into an aerated part and non-aerated part by baffle placed under the water. DO concentrations were controlled by altering the position of baffle. In terms of TSS and CODCr, all systems had a similar level of the removal under varied HRTs and MLSS. TSS removal efficiency was more than 99% and CODCr removal was ranged 94~97% under all conditions. Under the same condition on the HRT and MLSS concentrations, DO concentrations did not affect the organic removal efficiency. On the nitrification efficiency, with high DO concentration, as HRT or MLSS increased, the slight increment of nitrification efficiency was observed. However, under the low DO concentration, increase of MLSS and HRT resulted in larger increase of the nitrification efficiency. At the same HRT and MLSS, the nitrification efficiency increased greatly with up to 16% as DO increased. When the HRT increased from 4hr to 8hr, the denitrification efficiency slightly increased under most of conditions. However, the increase of MLSS resulted in about 19~39% denitrification efficiency increment. MLSS concentrations showed great effect on the denitrification. The increase of the DO concentration at the same HRT and MLSS resulted in decrease of denitrification efficiency with up to 27%. In all systems, the denitrification efficiency had more influence on the TN removal efficiency than nitrification efficiency. So, MLSS concentration has greater effect on the TN removal than HRT and DO. The TN removal efficiency increased as MLSS increased with up to 37%. As a result, the highest TN removal efficiency was observed 79.0% at the condition showed the highest denitrification efficiency that DO of 0.5~1.0 mg/L, an HRT of 8 hr, and 8,000 mg/L of MLSS concentration were maintained.

Early Stage Performance of Constructed Wetland System for Nonpoint Source Pollution Control (비점원오염 제어를 위한 인공습지의 초기단계 연구)

  • Kim, Hyung-Chul;Ham, Jong-Hwa;Han, Jung-Yoon;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.4 s.118
    • /
    • pp.481-488
    • /
    • 2006
  • The field scale experiment was performed to examine the performance of the constructed wetland for nonpoint source (NPS) pollution loading reduction. Four sets (0.88 ha each) of wetland and pond system were used. After three growing seasons of the wetland construction, plant coverage increased to about 90% even without plantation from bare soil surfaces at the initial stage. During the start up period of constructed wetlands, lower water levels should be maintained to avoid flooding newly plants, if wetland plants are to start from germinating seeds. The average removal rate of $BOD_5$, TSS, T-N and T-P during the first two years was 5.6%, 46.6%, 45.7%, and 54.8%, respectively. The $BOD_5$ removal rate was low and it might be attributed to the low influent concentration. The early stage of wetland performance demonstrated the effectiveness of water quality improvement and was satisfactory for treating polluted stream waters. From the first-order analysis, T-P was virtually not temperature dependent, and $BOD_5$ and TSS were more temperature dependent than T-N. A pond-wetland system was more effective than a wetland-pond or a wetland alone system in water quality improvement, particularly to reduce T-P. Overall, the wetland system was found to be an adequate alternative for treating a polluted stream water with stable removal efficiency and recommended as a NPS control measures.

Removal Efficiency of Pollutants in Agricultural Wastewater by Constructed Wetlands on Reclaimed Land in the Goheung Bay (고흥만 간척지 내 인공습지에 의한 농경배수 정화효율에 관한 연구)

  • Yu, Hun-Sun;Kang, Dong-Hwan;Kwon, Byung-Hyuk
    • Journal of Wetlands Research
    • /
    • v.11 no.3
    • /
    • pp.37-47
    • /
    • 2009
  • This research was conducted at the constructed wetland in Goheung reclaimed land, and water quality components were measured at the 12 points in 15 March 2008 and 10 January 2009, respectively. Temperature, pH, DO, EC and salinity components were measured at the field, and TOC, Cl-, COD, TSS, T-P and TN components were analyzed laboratory. Concentrations of field measured components at inflow points were higher than in constructed wetland. TOC concentration ratio of inflow water to constructed wetland water was higher in January, and Cl concentration ratio of it was higher in March. And, COD concentration ratio of it were 1.37 for March and 1.49 for January, respectively. T-P and T-N concentration ratios of it at inflow points were higher 3 times than in constructed wetland. Constructed wetland attenuated concentration of contaminated components inflow to it. Removal efficiencies of Cl-, T-P and T-N components in inflow water were high at the constructed wetland. removal efficiencies of Cl component were 83% for 1st monitoring and 76% for 2nd monitoring, this removal efficiency be caused by dilution effect of constructed wetland. removal efficiencies of T-P component were 67% for 1st monitoring and 69% for 2nd monitoring, and they of T-N component were 100% for 1st monitoring and 95% for 2nd monitoring. Abnormal removal efficiency of T-N component is caused that nitrogen in inflow water was a little. Removal efficiency of T-P component was higher in January, and T-N component was higher in March. This is caused by environmental difference between growing season and winter.

  • PDF

Evaluation of Particle Removal Rate in Inclined-pipe Settling System for Stormwater Infiltration (강우유출수의 침투시 부하저감을 위한 경사관 침전장치의 효율평가)

  • Kim, Sangrae;Kim, Dongkeun;Mun, Jungsoo;Han, Mooyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.23 no.6
    • /
    • pp.719-726
    • /
    • 2009
  • One of the alternative runoff management measures is on-site runoff mitigation, such as rainwater retention tank and infiltration facilities especially the latter that is possible to manage simultaneously runoff quality and quantity as a perspective of water-cycle. This study was conducted to develop a particle separator, inclined-pipe settling system, that could improve particle removal efficiency of road runoff as a pre-treatment device of stormwater infiltration. Solid particles larger than $100{\mu}m$ are separated by simple sedimentation; however, the significant amount of pollutants with a diameter less than $100{\mu}m$ remain in suspension. Without any treatment in that case of the runoff into infiltrate, groundwater would be deteriorated and also infiltration rate would be decreased by clogging. Therefore, we suggest optimal design parameters (inclined angle, pipe length, and surface loading rate) of inclined-pipe settling system which can be designed to effectively remove particles diameter smaller then $70{\mu}m$. Thus, the results showed TSS removal efficiency more than 80% with a particle diameter between $20{\mu}m$ and $70{\mu}m$, 100% above particle diameter $70{\mu}m$ for the inflow rate $0.018 m^3/m^2{\cdot}hr$ with pipe inclined at angle $15^{\circ}$.

The study of chemical treatment of pulp mill bleaching waste liquor using lime (석회를 이용한 펄프공장 폐액의 화학적 처리에 관한 연구)

  • 정병곤;이헌모;윤종호
    • Journal of environmental and Sanitary engineering
    • /
    • v.12 no.2
    • /
    • pp.23-28
    • /
    • 1997
  • This study was conducted to know the possibility of reducing lime dosage by recycling sludge from bleaching wastewater lime coagulation settlement treatment at pulp mill process. In case of bleaching wastewater at the pulp mill process, when the lime dosage was increased, the removal efficiency of TSS(Total Suspended Solids) was increased, proportionally, but the organic removal efficiency was increased very slowly. It was concluded that sludge recycling at the lime coagulation settlement process was effective method to reduce the requirement of lime dosage. At the lime coagulation settlement process with sludge recycling, when the recycling number was increased, the organic removal efficiency was decreased, sharply. It was evaluated that the pH could be the basic standard for lime supplement by sludge recycling.

  • PDF

An Experimental Study on Filtration Efficiency of Sand Filter Layers to TSS and COD in Non-point Source Pollutant (분산형 빗물 저류조용 모래 여과층을 적용한 도심지 비점오염원의 TSS와 COD 정화효율에 대한 실험적 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1477-1488
    • /
    • 2014
  • Prevalent construction of impermeable pavements in urban areas causes diverse water-related environmental issues, such as lowering ground water levels and shortage of water supply for the living. In order to resolve such problems, a rainwater reservoir can be an effective and useful solution. The rainwater reservoir facilitates the hydrologic cycle in urban areas by temporarily retaining precipitation-runoff within a shallow subsurface layer for later use in a dry season. However, in order to use the stored water of precipitation-runoff, non-point source pollutants mostly retained in initial rainfall should be removed before being stored in the reservoir. Therefore, the purification system to filter out the non-point source pollutants is essential for the rainwater reservoir. The conventional soil filtration technology is well known to be able to capture non-point source pollutants in a economical and efficient way. This study adopted a sand filter layer (SFL) as a non-point source pollutant removal system in the rainwater reservoir, and conducted a series of lab-scale chamber tests and field tests to evaluate the pollutant removal efficiency and applicability of SFL. During the laboratory chamber experiments, three types of SFL with the different grain size characteristics were compared in the chamber with a dimension of $20cm{\times}30cm{\times}60cm$. To evaluate performance of the reservoir systems, the concentration of the polluted water in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) were measured and compared. In addition, a reduction in hydraulic conductivity of SFL due to pollutant clogging was indirectly estimated. The optimum SFL selected through the laboratory chamber experiments was verified on the in-situ rainwater reservoir for field applicability.

Research on Design Capacity Evaluation of Low Impact Development according to Design Criteria (저영향개발 시설 설계 기준에 따른 용량 평가 방법 연구)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.24 no.1
    • /
    • pp.59-67
    • /
    • 2022
  • The interest in LID facilities is increasing worldwide for recovery of natural water cycle system to destroy by urbanization. However, problems are raised when installation of LID because comprehensive analysis about design capacity adequacy of LID facilities was not conducted completely. In this research, removal efficiency and design volume adequacy of LID facilities were analyzed based on rainfall monitoring data in four LID facilities(Vegetated Swale, Vegetative Filter Strip, Bio-Retention and Permeable Pavement). As a result, group of LID facility designed on WQV was shown higher flow(37%) and pollutants(TSS, BOD, TN and TP) removal efficiencies(20 ~ 37%) than group of LID facility designed on WQF. SA/CA graph was drawn for evaluation of design volume adequacy based on rainfall monitoring data. In this SA/CA graph, coefficient of determination show over 0.5 in all parameter, especially, Flow and TP were show over 0.95. And, 'SA/CA & L/CA' graph considering difference of structure mechanism in LID facility suggested in this research was confirmed that improved coefficient of determination in flow, TSS and TP than SA/CA graph. According to this research results, feasibility of applying 'SA/CA & L/CA' graph for evaluation of design volume adequacy in LID facility, and it is necessary to follow up research for generalization and normalization.

Seasonal Performance of Constructed Wetland for Nonpoint Source Pollution Control (비점오염원 제어를 위한 인공습지의 계절변화에 따른 처리효율 평가)

  • Ham, Jong-Hwa;Han, Jung-Yoon;Kim, Hyung-Chul;Yoon, Chun-Gyeong
    • Korean Journal of Ecology and Environment
    • /
    • v.39 no.4 s.118
    • /
    • pp.471-480
    • /
    • 2006
  • The field scale experiment was performed to examine the performance of the constructed wetland for nonpoint source (NPS) pollution loading reduction. Four sets (each set of 0.88 ha) of wetland (0.8 ha) and pond (0.08 ha) systems were used. Water flowing into the Seokmoon estuarine reservoir from the Dangjin stream was pumped into wetland systems. Water depth was maintained at 0.3-0.5 m and hydraulic retention time was managed to about 2-5 days; emergent plants were allowed to grow in the wetland. The wetland effluent concentrations of $BOD_5$, TSS, and T-N were higher in winter than in the growing season excepting the T-P, and effluent $BOD_5$ concentration was higher than influents in winter. Mass retention of T-N and T-P was stable throughout the year, whereas mass retention of $BOD_5$ and TSS was decreased in winter. $BOD_5$, TSS, T-N, and T-P performance of the experi-mental system was compared with the existing database (North American Treatment Wetland Database), and was within the range of general system performance. From the first-order analysis, T-P was virtually not temperature dependent, and $BOD_5$ and TSS were more temperature dependent than T-N. Overall, the wetland system was found to be an adequate alternative for treating polluted stream water with stable removal efficiency and recommended as a NPS control measures.