• Title/Summary/Keyword: TPH-1

Search Result 188, Processing Time 0.021 seconds

호소 및 하천의 오염 저질토 sampling 방법 및 처리방안 연구

  • 최동호;배우근;최형주
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.115-119
    • /
    • 2003
  • Pollutants from industry, mining, agriculture, and other sources have contaminated sediments in many surface water bodies. Sediment contamination poses a severe threat to human health and environment because many toxic contaminants that are barely detectable in the water body can accumulate in sediment at much higher levels, the purpose of this study was to make convenient sampling method and optimal treatment of sediment for water quality improvement in reservoir or stream based on an evaluation of degree of contamination. Results for analysis of S-reservoir sediments were observed that copper concentration of almost areas were higher than the regulation of soil pollution (50 mg/1) for the riverbed. S-stream sediments were observed that copper, arsenic and TPH concentration of almost areas were exceeded soil pollution concerning levels for factorial areas. We used Remscreen(version. 1.0) program which is contaminated soil recovery program to select optimal treatment method of contaminant sediments. The result was shown in the order of Thermal Calcination > Excavation, Retrieval and Off-site Disposal(comparative less then contaminant) > Low Temperature Thermal Desorption + Solidification/Stabilization.

  • PDF

Development of In-Situ Soil Gas Monitoring Well for Managing the Bioventing Performance (생물학적 통풍법 공정관리를 위한 원위치 토양가스 관측정 개발)

  • Yu, Chan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.49 no.1
    • /
    • pp.67-76
    • /
    • 2007
  • Bioventing is commonly used for petroleum hydrocarbon (PHC) spills. This process provides better subsurface oxygenation, thus stimulating degradation by indigenous microorganisms. Therefore soil vapor monitoring points (VMPs) are extremely important in determining the potential effectiveness of bioventing and in long-term monitoring of bioventing progress. In this study in-situ soil gas monitoring well (GMW) was developed and presented the pilot test results which recover the contaminated site by bioventing method. The result of application was successful and it was expected that GMW developed could be applied to the evaluation procedure of bioventing effectiveness and long-term remediation potential.

Effects of Soil Temperature on Biodegradation Rate of Diesel Compounds from a Field Pilot Test Using Hot Air Injection Process (고온공기주입 공법 적용시 지중온도가 생분해속도에 미치는 영향)

  • Park Gi-Ho;Shin Hang-Sik;Park Min-Ho;Hong Seung-Mo;Ko Seok-Oh
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.4
    • /
    • pp.45-53
    • /
    • 2005
  • The objective of this study is to evaluate the effects of changes in soil temperature on biodegradation rate of diesel compounds from a field pilot test using hot air injection process. Total remediation time was estimated from in-situ biodegradation rate and temperature for optimum biodegradation. All tests were conducted by measuring in-situ respiration rates every about 10 days on highly contaminated area where an accidental diesel release occurred. The applied remediation methods were hot air injection/extraction process to volatilize and extract diesel compounds followed by a bioremediation process to degrade residual diesels in soils. Oxygen consumption rate varied from 2.2 to 46.3%/day in the range of 26 to $60^{\circ}C$, and maximum $O_2$ consumption rate was observed at $32.0^{\circ}C$. Zero-order biodegradation rate estimated on the basis of oxygen consumption rates varied from 6.5 to 21.3 mg/kg-day, and the maximum biodegradation rate was observed at $32^{\circ}C$ as well. In other temperature range, the values were in the decreasing trend. The first-order kinetic constants (k) estimated from in-situ respiration rates measured periodically were 0.0027, 0.0013, and $0.0006d^{-1}$ at 32.8, 41.1, and $52.7^{\circ}C$, respectively. The estimated remediation time was from 2 to 9 years, provided that final TPH concentration in soils was set to 870 mg/kg.

A STUDY ON THE DEGREE OF CONVERSION OF LIGHT CURING COMPOSITE RESIN ACCORDING TO THE DEPTH OF CURE AND LIGHT CURING TIME (수종 광중합 복합 레진의 중합 깊이와 광조사 시간에 따른 중합률에 관한 연구)

  • Kim, Kyung-Hyun;Kwon, Oh-Sung;Kim, Hyun-Gee;Baek, Kyu-Chul;Um, Chung-Moon;Kwon, Hyuk-Choon
    • Restorative Dentistry and Endodontics
    • /
    • v.22 no.1
    • /
    • pp.35-60
    • /
    • 1997
  • Physical properties of composite resins such as strength, resistance to wear, discoloration, etc, depend on the degree of conversion of the resin components. The clinical behavior of restorative resins varies brand to brand. Part of this variation is associated with the filler and differences in the polymer matrix. The polymer matrix of resins may differ because the involved monomers are dissimilar and because of variation in the catalyst system. The purpose of this study was to evaluate the degree of conversion of the composite resins according to the depth of cure and light curing time. 7mm diameter cylindrical aluminum molds were filled with each of five different hybrid light curing composite resins(Z-100, Charisma, Herculite XRV, Prisma TPH, Veridonfil) on the thin resin films. The molds were 1mm, 2mm, 3mm, 4mm, and 5mm in depth to produce resin films of various heights. Each sample was given 20sec, 40sec, and 60sec illumination with a light source. The degree of conversion of carbon double bonds to single bonds in the resin films was examined by means of Fourier Transform Infrared Spectrometer. The results were obtained as follows; 1. There was difference in the degree of conversion among five light curing composite resins according to the depth of cure for 20sec, 40sec, and 60sec illumination with light source with statistical significance(P<0.05). 2. Five light curing composite resins show lower degree of conversion at surface of the resin than depth of 1mm. 3. The degree of conversion of five light curing composite resins was siginificantly reduced from the maximum for the resin film when the light passed through as little as 1mm of each composite. 4. The degree of conversion of five light curing composite resins decrease significantly at the depth of 4mm, and polymerization was not occured at the depth of 5mm except for Prisma TPH. 5. The degree of conversion of five light curing composite resins was increased with increased light curing time, and there was no significant differences in the degree of conversion above 4mm in Z-100, 3mm in Charisma, and at depth of 5mm in Herculite XRV and Veridonfil(P>0.05).

  • PDF

Degradation of TPHs, TCE, PCE, and BTEX Compounds for NAPLs Contaminated Marine Sediments Using In-Situ Air Sparging Combined with Vapor Extraction (증기추출법과 결합된 공기주입법을 이용한 비수용성액체 해양퇴적물의 TPHs, TCE, PCE 및 BTEX 정화)

  • Lee, Jun-Ho;Han, Sun-Hyang;Park, Kap-Song
    • Economic and Environmental Geology
    • /
    • v.46 no.5
    • /
    • pp.425-444
    • /
    • 2013
  • This study was carried out in order to determine the remediation of total petroleum hydrocarbons (TPHs), trichloroethylene (TCE), perchloroethylene (PCE), benzene, toluene, ethylbenzene and xylenes (BTEX) compounds for non-aqueous phase liquids (NAPLs) using in-situ air sparging (IAS) / vapor extraction (VE) with the marine sediments of Mandol, Hajeon, Sangam and Busan, South Korea. Surface sediment of Mandol area had sand characteristics (average particle size, 1.789 ${\Phi}$), and sandy silt characteristics (average particle size, 5.503 ${\Phi}$), respectively. Sangam surface sediment had silt characteristics (average particle size, 5.835 ${\Phi}$). Sediment characteristics before experiment in the Busan area showed clay characteristics (average particle size, 8.528 ${\Phi}$). TPHs level in the B1 column of Mandol, Hajeon, Sangam, and Busan sediments were 2,459, 6,712, 4,348, and 14,279 ppm. B2 (3 L/min) to B5 (5 L/min) columns reduced 99.5% to 100.0% of TCE and 93.2% to 100.0% of PCE. Removal rates of TCE, PCE, and BTEX are closely correlated (0.90-0.99) with particle sizes and organic carbon concentrations. However, TPHs (0.76) and benzene (0.71) showed the poorer but moderate correlations with the same parameters.

Antidepressant effects of capsaicin in rats with chronic unpredictable mild stress-induced depression (만성 스트레스로 유발된 우울증 쥐 모델에서 캡사이신의 항우울 효과)

  • Jae Ock, Lim;Min Ji, Kim;Jun Beom, Bae;Chan Hyeok, Jeon;Jae Hyeon, Han;Tae Hyeok, Sim;Youn Jung, Kim
    • Journal of Korean Biological Nursing Science
    • /
    • v.25 no.1
    • /
    • pp.280-320
    • /
    • 2023
  • Purpose: This study was conducted to assess the antidepressant effects of capsaicin in chronic depressive rats and elucidate the mechanism underlying its effects. Methods: Male Wistar rats (280~320 g, 8 weeks of age) were subjected to depression induced by chronic unpredictable mild stresses. The rats were exposed to 8 kinds of stresses for 8 weeks. In the last 2 weeks, fluoxetine or capsaicin was injected subcutaneously. The dose of fluoxetine was 10 mg/kg (body weight), while the doses of capsaicin consisted of low (1 mg/kg), middle (5 mg/kg), and high (10 mg/kg). The forced swim test (FST) was conducted to evaluate the immobility time of rats. The immobility time indicates despair, one of symptoms of depression. The change of tryptophan hydroxylase (TPH) in the dorsal raphe was investigated using immunohistochemistry. In the hippocampus cornu ammonis (CA) 1 and 3, glucocorticoid receptor (GR) expression was measured. Results: The immobility time in the FST was significantly lower (p < .05) in the low-dose (M = 32.40 ± 13.41 seconds) and middle-dose (M = 28.48 ± 19.57 seconds) groups than in the non-treated depressive rats (M = 90.19 ± 45.34 seconds). The amount of TPH in the dorsal raphe was significantly higher (p < .05) in the middle-dose (M = 249.17 ± 35.02) and high-dose (M = 251.0 ± 56.85) groups than in the non-treated depressive rats (M = 159.78 ± 41.16). However, GR expression in the hippocampus CA1 and CA3 did not show significant differences between the non-treated depressive rats and the capsaicin-injected rats. Conclusion: This study suggests that capsaicin produces an antidepressant-like effect on chronic unpredictable mild stress-induced depression in rats via the serotonin biosynthesis pathway.

디젤오염 토양 정화를 위한 토양세정 및 응집효과

  • 박준석;박종은;신철호;원찬희;김승호
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.285-288
    • /
    • 2004
  • 약 10,000 ing TPH/kg으로 오염시킨 디젤오염토양을 계면활성제로 세정한 결과 단일 계면활성제를 사용한 경우에는 POE12가 63%로 가장 세정효율이 우수하였다 단일 계면활성제를 혼합하여 세정한 결과 POE12와 SDS를 1%로 혼합하였을 때 10%의 세정증가효과가 있었으나, 다른 혼합액에서는 POE12를 단일로 사용한 경우와 유사하거나 오히려 감소하였다. 토양세정과 응집제를 사용하여 디젤오염토양을 정화할 경우 비이온 계면활성제인 POE12와 음이온 계면활성제인 SDS를 혼합하여 세정한 후 고분자 응집제인 A601p를 사용하여 세정액을 응집처리하는 것이 가장 효과적이었다.

  • PDF

A Study on the Degree of Pollution of Stream and Reservoir Sediments in Rural Area (농촌 중.소 하천 및 저수지 퇴적물의 오염현황)

  • Chang, Pyoung-Wuck;Woo, Chull-Woong;Kim, Seong-Pil
    • Journal of Korean Society of Rural Planning
    • /
    • v.9 no.2 s.19
    • /
    • pp.1-6
    • /
    • 2003
  • This study was performed to investigate the degree of pollution of sediments of stream and reservoir in rural area. A series of field investigations were carried out for Kyongki-do area and chemical analysis were performed for sediment samples. It was found that some samples were heavily polluted with phenol and TPH and gave off a malodor. Soil Pollution Scores(SPSs) was determined for sediment samples. Some samples were classified to Soil Pollution Class(SPC) 2 and 3. For recycling and disposal of dredged sediments from stream and reservoirs, these polluted sediments should be carefully considered. In the environmental improvement operations of rural area, the degree of pollution of sediments of stream and reservoir are carefully investigated and suitable counterplan must be established.

Beneficial Effect of Hyangsayangwi-tang on the Cisplatin-Induced Gastrointestinal Dysfunctions in Rats (향사양위탕이 시스플라틴 유발 랫트의 위장관 기능 장애에 미치는 영향)

  • Seo, Eun-Hee;Kim, Seong-Tae;Bae, Na-Young;Choi, Ae-Ryun
    • Journal of Sasang Constitutional Medicine
    • /
    • v.25 no.4
    • /
    • pp.343-358
    • /
    • 2013
  • Objectives This study aimed to observe the effect of Hyangsayangwi-tang on the cisplatin-induced gastrointestinal dysfunctions in rats. Methods Four groups(each of 8 rats per group) were used in this study. Saline and distilled water treated control rats are Intact vehicle control group. Delayed gatrointestinal mortility was induced by intraperitoneal treatment of cisplatin 2mg/kg, once a week for 5 weeks(Cisplatin control group). Hyangsayangwi-tang aqueous extracts(HY) were orally administered in a volume of 5ml/kg, once a day for 14 days from 4th ciplatin treatmernt(HY group). Ondansetron 1mg/kg was subcutaneously treated, in a volume of 1ml/kg, as same as HY(ondansetron group). We measured the body weights, intestinal charcoal transit ratio, fecal parameters, fundus MDA, GSH contents and SOD, CAT activities, TPH and MAO activities, pyloric gastrin and serotonin contents with their immunoraective cells, colonic serotonin-immunoreactive cells, the histopathology of pylorus, fundus mucosa and colon. Results and Conclusions (1) The body weight gains, the small intestinal charcoal transfer rates, the fecal parameters(numbers, weights and water contents) were increased in HY, ondansetron group. (2) The inhibit of fundus antioxidant defense systems by cisplatin were decreased in HY, ondansetron group. (3) The pyloric TPH activities were increased and the pyloric MAO activities were decreased in HY group. (4) The pyloric gastric contents and the gastrin-immunoreactive cells were increased in HY group. And the pyloric serotonin contents and the pyloric and colonic serotonin-immunoreactive cells were decreased in HY group. (5) The pyloru atrophic changes and the gastric surface erosive damage regions by cisplatin were favorably inhibited by treatment of HY. HY, a representative Soeumin prescription improve GI dysfunctions and constipation retarded by cisplatin through modulations of GI enterochromaffin cells, serotonin and gastrin-producing cells and antioxidative systems. Especially HY showed the highest favorable effects more than those of ondansetron.

A Study on the Effect of Improving Permeability by Injecting a Soil Remediation Agent in the In-situ Remediation Method Using Plasma Blasting, Pneumatic Fracturing, and Vacuum Suction Method (플라즈마 블라스팅, 공압파쇄, 진공추출이 활용된 지중 토양정화공법의 정화제 주입에 따른 투수성 개선 연구)

  • Geun-Chun Lee;Jae-Yong Song;Cha-Won Kang;Hyun-Shic Jang;Bo-An Jang;Yu-Chul Park
    • The Journal of Engineering Geology
    • /
    • v.33 no.3
    • /
    • pp.371-388
    • /
    • 2023
  • A stratum with a complex composition and a distributed low-permeability soil layer is difficult to remediate quickly because the soil remediation does not proceed easily. For efficient purification, the permeability should be improved and the soil remediation agent (H2O2) should be injected into the contaminated section to make sufficient contact with the TPH (Total petroleum hydrocarbons). This study analyzed a method for crack formation and effective delivery of the soil remediation agent based on pneumatic fracturing, plasma blasting, and vacuum suction (the PPV method) and compared its improvement effect relative to chemical oxidation. A demonstration test confirmed the effective delivery of the soil remediation agent to a site contaminated with TPH. The injection amount and injection time were monitored to calculate the delivery characteristics and the range of influence, and electrical resistivity surveying qualitatively confirmed changes in the underground environment. Permeability tests also evaluated and compared the permeability changes for each method. The amount of soil remediation agent injected was increased by about 4.74 to 7.48 times in the experimental group (PPV method) compared with the control group (chemical oxidation); the PPV method allowed injection rates per unit time (L/min) about 5.00 to 7.54 times quicker than the control method. Electrical resistivity measurements assessed that in the PPV method, the diffusion of H2O22 and other fluids to the surface soil layer reduced the low resistivity change ratio: the horizontal change ratio between the injection well and the extraction well decreased the resistivity by about 1.12 to 2.38 times. Quantitative evaluation of hydraulic conductivity at the end of the test found that the control group had 21.1% of the original hydraulic conductivity and the experimental group retained 81.3% of the initial value, close to the initial permeability coefficient. Calculated radii of influence based on the survey results showed that the results of the PPV method were improved by 220% on average compared with those of the control group.