Development of Tissue mimicking ultrasound phantom materials (Tissue mimicking 초음파 팬텀물질의 개발에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Park, Ki-Jung;Lee, Suk
    • Journal of radiological science and technology
    • /
    • v.26 no.1
    • /
    • pp.51-62
    • /
    • 2003
  • We carried out studies on develop of the ultrasound tissue mimicking materials(TMM) by synthesis of polymer urethane(C, CCR, $TiO_2$, tungsten, graphite, silver type). The major finding were as follows; (1) C type TMM was shown good homogeneity, penetration, gray scale like as liver tissue and propagated speed 1,540 m/s, attenuation $0.5{\sim}0.7\;dB/cm/MHz$. (2) $TiO_2$ type TMM was shown heterogeneous dot echo pattern. (3) Silver type TMM was appear good homogeneous echo pattern like as echo texture of thyroid gland. Therefor, C type TMM will be useful for ultrasound Q/A phantom materials and previous phantom materials.

  • PDF

The study on Development and characteristic of ultrasound biopsy training phantom of breast (유방 초음파 팬텀의 제작과 특성에 관한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun;Ahn, Young-Man
    • Journal of radiological science and technology
    • /
    • v.26 no.3
    • /
    • pp.19-24
    • /
    • 2003
  • We carried out studies on development and characteristic of ultrasound brast training biopsy phantom. the major finding were of follow ; (1) C type TMM was shown good homogeneity, brightness and attenuation as like human soft tissue. (2) $TiO_2$ 4.10%w/v TMM was shown good homogeneous echo texture and propagated speed as like the human Tissue. (3) $TiO_2$ type TMM was appeared lower brightness and higher penetration rate than C type TMM. Therefor, Breast TM phantom and target material TMM will be useful $TiO_2$ 4.10 %w/v TMM and C 2.09 %w/v TMM.

  • PDF

A Fat-Tissue Mimic Phantom for Therapeutic Ultrasound

  • Kim, Mi Seon;Kim, Ju Young;Jung, Hyun Du;Kim, Jae Young;Choi, Heung Ho
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.3
    • /
    • pp.153-159
    • /
    • 2014
  • As the number of treatments in the therapeutic ultrasound field targeted at fat tissue increase, the performance of the equipment should be evaluated for safety using a fat phantom. In this study, a fat phantom was fabricated using olive oil and a tissue-mimicking material (TMM) phantom. To evaluate the acoustic properties of the TMM phantom according to the changes in the olive oil, the composition ratio of a liquid mixture of olive oil with a surfactant was adjusted from 5-20% in 5% steps. The acoustic properties of the phantom were evaluated using the sound velocity, attenuation coefficient, density, and acoustic impedance. The experimental results showed that the sound velocity decreased with increasing amount of olive oil but the other acoustic properties did not change. In addition, the phantom using an olive-oil mixture with a 15% composition ratio was most similar to the acoustic characteristics of fat tissue with a sound velocity of 1477.35 m/s, an attenuation coefficient of 0.514 dB/MHz-cm, a density of $1.07g/cm^3$, and an acoustic impedance of 1.575 MRayl. These experimental results are expected contribute to the accuracy of the results using a TMM phantom and will be useful for the therapeutic ultrasound field targeted at subcutaneous fat tissue.

Improvement on resolution of mono-filament wire (초음파 팬텀 내 모노필라멘트의 해상력 개선에 대한 연구)

  • Ma, Sang-Chull;Kong, Young-Kun
    • Journal of radiological science and technology
    • /
    • v.26 no.2
    • /
    • pp.49-56
    • /
    • 2003
  • The purposes of this study are to improve the ultrasound resolution of various nylon and metallic mono-filament wires, therefore, it was tested that it analyze on nylon mono-filament wire of 0.1 mm in A Co.'s ultrasonic phantom and synthesis of C15 g tissue mimicking materials(TMM), analyze resolution of nylon and metallic mono-filament wires in water and TMM. The results obtained were summarized as follows: 1. Metallic mono-filament wire of 0.1 mm and nylon mono-filament wire of 0.12 mm, 180 denier showed that it cleared dot echo pattern. 2. Metallic and nylon mono-filament wire of 0.2 mm showed that it cleared comet tail echo by reverberation artifact. 3. Nylon and metallic mono-filament wire of 0.1 mm showed that it can used for dead zone and axial resolution test. 4. Nylon mono-filament wire compared with metallic mono-filament wire showed that it satisfy elasticity and construction. 5. Degree of hardness of na not changed mono-filament's echo textures.

  • PDF

Development of Human-Head-Mimicking Phantom for Brain Treatment Using Focused Ultrasound (집속 초음파 뇌 질환 치료를 위한 두부 유사 팬텀의 개발)

  • Min, Jeonghwa;Kim, Juyoung;Noh, Sicheol;Choi, Heungho
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.6
    • /
    • pp.433-439
    • /
    • 2013
  • In this study, human head-mimicking phantom was developed for brain disease treatment study using focused ultrasound. Acoustic parameters of skin, skull and brain were investigated through literature investigation and adequate substitutes according to each tissue were suggested. In the case of skin phantom, construction ratio of glycerol-based TMM phantom was controlled to mimic real skin. The suitability of skull substitutes was evaluated through measurement of acoustic parameters. In the case of brain phantom, transparent egg white phantom was used to observe thermal properties of focused ultrasound. Combined human-head-mimicking phantom using each substitutes was fabricated for development of brain disease treatment protocol. Denaturation of brain phantom according to ultrasonic condition was observed for validation.

The Implementation of TMM test phantom for evaluating the thermal performance in High Intensity Focused Ultrasound system (강력 집속 초음파 시스템의 열적 성능 평가를 위한 팬텀 개발에 관한 기초연구)

  • Yu, Woo-Jin;Noh, Si-Cheol;Park, Moon-Kyu;Min, Hae-Ki;Park, Jae-Hyun;Choi, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.484-485
    • /
    • 2008
  • 초음파는 의학적 진단 및 치료의 목적으로 널리 사용되어 왔다. 일반적으로, 초음파 조사의 생물학적 무해성은 많은 연구를 통하여 보고되었으나, 최근 초음파 집속을 통한 강력 초음파의 사용에 대한 열적 안전성 평가가 중요한 요소로 대두되고 있다. 이에 본 연구에서는 강력 집속 초음파의 전달 에너지와 열적 분포를 측정하여 안전성 평가에 활용 가능한 초음파 열분포 팬텀을 제안하였다. 온도 분포 측정용 팬텀은 초음파 조직유사 팬텀 재료인 한천을 이용하였으며, 음향학적 특성의 유사성을 평가하였다. 온도 효과를 측정하기 위하여 $3{\times}3$의 형태로 온도 센서를 팬텀 내부에 배열하여 초음파 조사에 따른 온도 분포를 측정하였고 온도 측정을 위한 시스템을 개발하여, 초음파 가열 실험을 수행하였다. 본 연구에서 제안된 초음파 온도 분포 측정용 팬텀의 유용성을 확인하였으며, 온도 분포용 팬텀을 통한 강력 집속 초음파 장비의 열적 성능 평가에 적용 될 수 있을 것으로 사료되었다.

  • PDF

A study for implementation of ultrasonic transducer in the prostate cancer hyperthermia (전립선암의 온열치료를 위한 초음파변환기 개발에 관한 연구)

  • Park, Mun-Kyu;Noh, Si-Cheol;Park, Jae-Hyun;Choi, Heung-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.18 no.5
    • /
    • pp.377-384
    • /
    • 2009
  • The ultrasonic hyperthermia for oncology has been developed and studied. The HIFU(high intensity focused ultrasound) is the most recent method to treat the tumor by using ultrasound. In this study, an insertion-type transducer for treating a prostate cancer, which can focus the ultrasonic beam mechanically and electrically, was designed and developed. The developed transducer was composed of three arrays, and each array has 32 elements. For the purpose of the mechanical focusing, both side arrays are slanted to the center array by $15^{\circ}$. With this structure, NFL(near field length) was set up as 30 mm. The PZT-4 and two matching layers were used, and the backing layer was excepted to prevent energy losses. The acoustic field analysis and the heating test were performed to evaluate the performance of developed transducer. The shape of an acoustic field, peak pressure, and acoustic pressure distribution were compared with numerical simulation. The NFL was 32 mm, the beam width was 5 mm, focal area was $40\;mm^2$, and peak pressure was 5.5 MPa. With heating by using developed transducer, the temperature increased up to $33^{\circ}C$ at focal zone. As a result of this study, the usefulness of suggested transducer for prostate cancer hyperthermia was confirmed by the acoustic field analysis and the heating test with TMM(tissue mimicking) phantom.