• Title/Summary/Keyword: THICKNESS

Search Result 26,128, Processing Time 0.044 seconds

A study on the transmittance due to thickness of zirconium core (지르코니아 코어의 두께에 따른 분광광도계 투과율에 관한 연구)

  • Jung, In-Ho;Park, Myung-Ja;Kim, Joo-Won
    • Journal of Technologic Dentistry
    • /
    • v.33 no.2
    • /
    • pp.129-136
    • /
    • 2011
  • Purpose: The purpose of this study was to investigate the transmittance differences of zirconium core due to thickness within the visible light spectrum. Methods: 36 specimens were divided into 3 groups (0.6mm, 0.8mm, 1.0mm) which have each 12 specimens. The size of specimens was 10mm high and 10mm wide. The transmittance of specimens are measured by spectrophotometer Model Cary 500 that can measure infrared-ray, visible wave and ultraviolet-ray. Results: The results shows that there was no significant difference between specimen's thickness and transmittance. Conclusion: The individual's color perception is personal and there are numerous factors that influence on it. In general, human eye can perceive the color of thing only within visible light spectrum but in this experiment through spectrophotometer there was no big difference between specimen's thickness and transmittance. To sum up, The most important factors were a layed porcelain structure and its thickness rather than core thickness in the porcelain crown.

Relation Between Measured Sea Ice Thickness and Freeboard on Chukchi and Beaufort Seas (추코트와 보퍼트 해에서 계측된 해빙 두께와 건현과의 관계)

  • Jeong, Seong-Yeob;Choi, Kyungsik;Cho, Seong-Rak;Kang, Kuk-Jin;Lee, Chun-Ju
    • Journal of Ocean Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.527-532
    • /
    • 2014
  • The thickness of Arctic sea ice is a particularly significant factor in Arctic shipping and other ice-related research areas such as scientific sea ice investigations and Arctic engineering. In this study, the relation between the measured sea ice thickness and freeboard on the Chukchi and Beaufort Seas during the 2010 and 2011 Arctic cruise of the icebreaking research vessel "Araon" were considered. An assumption of hydrostatic equilibrium was used to estimate the ice thickness as a function of the freeboard. Then, to examine the degree of error, a sensitivity analysis of the thickness estimation of the sea ice was conducted. The error in the density and depth of the snow and the error in the density of the seawater were subordinate parameters, but the density of the ice and the freeboard were the primary parameters in the error calculation. The presented relation formula showed fairly close agreement between the calculated and measured results at a freeboard of >0.24 m.

Influence of Multi-directional Dynamic Stabilization Exercise on Thickness of Abdominal Muscles

  • Yu, Jae-Young;Park, Jea-Cheol;Jeong, Jin-Gyu
    • The Journal of Korean Physical Therapy
    • /
    • v.28 no.4
    • /
    • pp.249-253
    • /
    • 2016
  • Purpose: The purpose of this study was to examine the influence of multi-directional dynamic stabilization exercise on the thickness of the external oblique abdominis, internal oblique abdominis, and transversus abdominis. Methods: For the study subjects, 40 adults were taken and divided into two groups and stabilization exercise was performed for 6 weeks. Changes in muscle thickness during the pre-experimental period, and at 2 weeks, 4 weeks, and 6 weeks were analyzed using repeated ANOVA. Results: The thickness of the external oblique abdominis, internal oblique abdominis, and transversus abdominis in the multi-directional dynamic stabilization exercise group showed significant differences per period and an interaction was observed between period and group (p<0.01), while there were no significant differences in changes per group (p>0.05). Conclusion: The effects of multi-directional stabilization exercises on abdominal muscle thickness differed. The results presented herein can be utilized as basic data for future studies and in development of rehabilitation treatments.

Monochromatic Image Analysis of Elastohydrodynamic Lubrication Film Thickness by Fringe Intensity Computation

  • Jang, Siyoul
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.11
    • /
    • pp.1704-1713
    • /
    • 2003
  • Point contact film thickness in elastohydrodynamic lubrication (EHL) is analyzed by image processing method for the images from an optical interferometer with monochromatic incident light. Interference between the reflected lights both on half mirror Cr coating of glass disk and on super finished ball makes circular fringes depending on the contact conditions such as sliding velocity, applied load, viscosity-pressure characteristics and viscosity of lubricant under ambient pressure. In this situation the film thickness is regarded as the difference of optical paths between those reflected lights, which make dark and bright fringes with monochromatic incident light. The film thickness is computed by numbering the dark and bright fringe orders and the intensity (gray scale image) in each fringe regime is mapped to the corresponding film thickness. In this work, we developed a measuring technique for EHL film thickness by dividing the image patterns into two typical types under the condition of monochromatic incident light. During the image processing, the captured image is converted into digitally formatted data over the contact area without any loss of the image information of interferogram and it is also interpreted with consistency regardless of the observer's experimental experience. It is expected that the developed image processing method will provide a valuable basis to develop the image processing technique for color fringes, which is generally used for the measurement of relatively thin films in higher resolution.

The Analysis on Diaphragm Thickness and Lung Function of Stroke Patients by Walking Ability (뇌졸중 환자의 보행능력에 따른 횡격막 두께와 폐기능 분석)

  • Jung, Ju-Hyeon;Kim, Nan-Soo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.6 no.4
    • /
    • pp.437-445
    • /
    • 2011
  • Purpose : The purpose of this study was to analysis on diaphragm thickness and lung function of stroke patients by walking ability. Methods : We recruited thirty-five adults after stroke(20 male, 15 female) for our study. The subjects were divided into two groups; independent walking group(11 male, 9 female) and non-independent walking group(9 male, 6 female). Assessment of diaphragm thickness was performed using ultrasound in B-mode with a 7.5 MHz linea probe. During the experiment, the subject was seated in the chair. All subjects performed maximal expiratory flow maneuvers using a spirometer in order to determine the forced expiratory volume in 1 second ($FEV_1$), forced vital capacity(FVC), peak expiratory flow(PEF) and $FEV_1$/FVC. Chest expansion was measured with a tape-measure placed circumferentially around the chest wall at the xiphoid process. The collected data analyzed by independent t-test. Results : The diaphragm thickness were significant differences between the independent walking and nonindependent walking group. Values of forced vital capacity, forced expiratory volume at one second, peak expiratory flow in pulmonary function tests were significant differences between the independent walking and non-independent walking group. However, chest expansion were not significant differences in both of the group. Conclusion : This study showed that walking ability of stroke patients have influenced on diaphragm thickness and pulmonary function.

Ultrasonographic findings of the normal diaphragm: thickness and contractility

  • Seok, Jung Im;Kim, Shin Yeop;Walker, Francis O.;Kwak, Sang Gyu;Kwon, Doo Hyuk
    • Annals of Clinical Neurophysiology
    • /
    • v.19 no.2
    • /
    • pp.131-135
    • /
    • 2017
  • Background: Neuromuscular ultrasound can be used to assess the diaphragm. Before it can be used clinically, the reference ranges of diaphragm thickness and contractility must be determined. Methods: We measured the thickness of the diaphragm and the diaphragmatic thickening fraction (DTF) in 80 healthy volunteers with ultrasound and collected their demographic information to determine if age, sex, and body mass index (BMI) influence these measures. Results: The thickness of the diaphragm at resting end expiration was $0.193{\pm}0.044cm$ on the right side and $0.187{\pm}0.039cm$ on the left. The DTF was $104.8{\pm}50.6%$ on the right side and $114.9{\pm}49.2%$ on the left. Sex, weight, height, and BMI significantly affected the thickness of the diaphragm, but had little effect on the DTF. Conclusions: Normal reference values for the diaphragm should be helpful when evaluating the diaphragm. The DTF appears more useful than resting diaphragm thickness because it is affected less by individual variation.

Vapor Permeability and Moisture Gradient on a Paulownia Wood for Inside Material of Furniture Making

  • Lee, Won-Hee
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.6
    • /
    • pp.447-451
    • /
    • 2008
  • This study was carried out to know the difference of vapor transmission on the thickness of Paulownia wood(Paulownia tomentosa). The behavior of moisture transmission of wood thickness direction is generally estimated by vapor permeability and vapor transmission resistance. In general, Paulownia wood is known to use of inside material for furniture making, because of the excellent ability of vapor adsorption and/or desorption. Quarter sawing Paulownia wood material is prepared and the thickness is 6.0mm, 7.0mm, 8.0mm, 9.0mm, 10.0mm, respectively. The measurement of vapor transmission were conducted by the "cup method" in accordance with JIS(Japanese Industrial Standard) Z-0208. The experiment was made in the condition of 49.8mmHg vapor pressure difference and $40^{circ}C$ at constant temperature. From the experiment results, it was considered that Paulownia wood is very stable on moisture variation and any other material conditions. In this experiment we found that the vapor permeability and vapor permeance was reduced with the increase of wood thickness to vapor direction and vapor transmission resistance and specific vapor transmission resistance was increased with the increase of wood thickness to vapor direction. Besides moisture contents of adsorption and desorption side were about 5 percent and 14 percent, respectively. Mean value was 9.5 percent and about 10 percent in dry oven method. Moisture gradient was reduced with the increase of wood thickness for a small moisture difference of adsorption and desorption side.

  • PDF

A Study on Heat Transfer Characteristics in the Air Side of Louvered Fin Heat Exchanger (루우버핀형 열교환기의 공기측 열전달 특성에 관한 연구)

  • Kim, Sun-Jung
    • Journal of the Korean Solar Energy Society
    • /
    • v.23 no.1
    • /
    • pp.9-16
    • /
    • 2003
  • For the study of an effect that fin thickness and shape of heat exchanger have on the elevation of heat transfer efficiency, we make models of plate fin type heat exchanger and louvered fin type heat exchanger which was given a transformation of fin thickness in plate f)n type heat exchanger and louvered fin type heat exchanger which are often used now. And the effect of fin thickness on pressure drop and characteristics of heat transfer was experimented and analysed when air velocity and temperature of plate heating was a variable. The results of experiment shows below. Pressure drop shows larger in louvered fin type exchanger than in plate fin type exchanger, size of pressure drop shows like this order that fin thickness is 0.3mm, 0.2mm, 0.1mm. Mean heat transfer coefficient shows higher in louvered fin type exchanger than in plate fin type exchanger, size of mean heat transfer coefficient by fin thickness shows same in both case in louvered fin type heat exchanger and plate fin type exchanger like this order that fin thickness is 0.1mm, 0.2mm, 0.3mm.

Evaluation of mandibular cortical bone thickness for placement of temporary anchorage devices (TADs)

  • Kim, Jung-Hoon;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.42 no.3
    • /
    • pp.110-117
    • /
    • 2012
  • Objective: In this study, we measured the cortical bone thickness in the mandibular buccal and lingual areas using computed tomography in order to evaluate the suitability of these areas for application of temporary anchorage devices (TADs) and to suggest a clinical guide for TADs. Methods: The buccal and lingual cortical bone thickness was measured in 15 men and 15 women. Bone thickness was measured 4 mm apical to the interdental cementoenamel junction between the mandibular canine and the 2nd molar using the transaxial slices in computed tomography images. Results: The cortical bone in the mandibular buccal and lingual areas was thicker in men than in women. In men, the mandibular lingual cortical bone was thicker than the buccal cortical bone, except between the 1st and 2nd molars on both sides. In women, the mandibular lingual cortical bone was thicker in all regions when compared to the buccal cortical bone. The mandibular buccal cortical bone thickness increased from the canine to the molars. The mandibular lingual cortical bone was thickest between the 1st and 2nd premolars, followed by the areas between the canine and 1st premolar, between the 2nd premolar and 1st molar, and between the 1st molar and 2nd molar. Conclusions: There is sufficient cortical bone for TAD applications in the mandibular buccal and lingual areas. This provides the basis and guidelines for the clinical use of TADs in the mandibular buccal and lingual areas.

Facial soft tissue thickness among skeletal malocclusions: is there a difference?

  • Kamak, Hasan;Celikoglu, Mevlut
    • The korean journal of orthodontics
    • /
    • v.42 no.1
    • /
    • pp.23-31
    • /
    • 2012
  • Objective: The purpose of this study was to determine the soft tissue thickness of male and female orthodontic patients with different skeletal malocclusions. Methods: Soft tissue thickness measurements were made on lateral cephalometric radiographs of 180 healthy orthodontic patients with different skeletal malocclusions (Class I: 60 subjects, Class II: 60 subjects, Class III: 60 subjects). Ten measurements were analyzed. For statistical evaluation, one-way ANOVA and Kruskal-Wallis tests were performed. Least significant difference (LSD) and Dunnet T3 post hoc tests were used to determine the individual differences. Results: Soft tissue thicknesses were found to be greater for men than for women. Statistically significant differences among the skeletal groups were found in both men and women at the following sites: labrale superius, stomion, and labrale inferius. The thickness at the labrale superius and stomion points in each skeletal type was the greatest in Class III for both men and women. On the other hand, at the labrale inferius point, for both men and women, soft tissue depth was the least in Class III and the greatest in Class II. Conclusions: Soft tissue thickness differences among skeletal malocclusions were observed at the labrale superius, stomion, and labrale inferius sites for both men and women.