• 제목/요약/키워드: THICKNESS

검색결과 26,125건 처리시간 0.044초

BIW 전착도장에서의 컴퓨터 시뮬레이션 적용사례 (Introduction of Computer Simulation for BIW Electrocoating Process)

  • 손대홍;정희진;안승호;김병수;김정연;최병삼
    • Corrosion Science and Technology
    • /
    • 제15권2호
    • /
    • pp.78-83
    • /
    • 2016
  • The e-coating to inhibit induced corrosion can deposit a coating not only on the exterior surface but also on the inside of whole metallic components of body-in-white (BIW). But it is difficult to deposit paint films on the inside area because metallic components are multi layered. It may cause shortness of e-coating thickness. The only way to properly verify e-coating thickness is by performing the use of tear-down prototypes. When paint films' thickness is inadequate, a structural modification on each metallic component is needed. Verification of the thickness improvement for a structural modification requires much manual effort and leads to increasing development time. Recently, the simulation technology has been developed to predict the e-coating thickness in e-coating field. By applying the simulation to BIW, improvement in paint thickness quality and shortening of development period are expected. The paper explains a validated solution that allows simulating the effect of design changes to the e-coating thickness and current density, thereby delivering results within a time frame of a few days.

폴리머 콘크리트 샌드위치 패널의 휨에 관한 실험적 연구 (An Experimental Study on the Flexural Deflection of Sandwich Panels with Polymer Concrete Facings)

  • 함형길;이석건;연규석;이현우;이종원
    • 한국농공학회지
    • /
    • 제39권1호
    • /
    • pp.54-63
    • /
    • 1997
  • The purpose of this study is to analyse deformation properties by carrying out of flexure experimentations after fabricating polymer concrete sandwich panels which are composed of the polymer concrete in facing and expanded polystyren in cores, and to provide the basic data necessary to design, fabricate and operate the structure using these polymer concrete sandwich panels The analysed result of this study is summarized as follows. 1. The result of experiment on flexural deflection indicated that the thicker the thickness of both cores and facing of the polymer concrete sandwich panels, the smaller the deflection but the larger the ultimate shear force. In addition, it was also shown that the thicker the thickness of these cores and facing, the smaller the increasing rate of the deflection with the increase of load. 2. The breaking shape of polymer concrete sandwich panels by experiment on flexure was different according to the thickness of facing. When the facing was 5mm in thickness, it was the flexure while it was the flexure and shear failure when the facing was 5mm in thickness. As a result, it seems that the thickness of the facing has a great effect on failure. 3. There were induced not only the related formula between load, deflection and deformation according to the thickness of cores and facing on the basis of the flexure experiment, but also formula between load, horizontal displacement, Then, it seems that it will be possible to estimate the above elements by using these related formulas.

  • PDF

질화규소 이층 층상재료에서 코팅층의 파괴에 관한 연구 : II Coating Thickness의 영향 (A Study on the Coating Fracture in Silicon Nitride Bilayer : II. Effect of Coating Thickness)

  • 이기성;이승건;김도경
    • 한국세라믹학회지
    • /
    • 제35권1호
    • /
    • pp.48-54
    • /
    • 1998
  • Part I에 이어서 질화규소로 코팅된 질화규소-질화붕소 시스템에 있어서 접촉하중에 의한 코팅층의 파괴에 대한 코팅층의 두께의 영향을 고찰하였다. 코팅층과 기판층간의 elastic/plastic mismatch가 큰 경우 코팅층의 균열생성을 방지하는 어느 임계 두께가 존재한다는 사실을 발견하였으며, mismatch가 감소할수록 이러한 요구 임계두께가 감소하였다. 또한 가해진 하중이 증가할수록 요구 임계두께는 증가하여야 함을 알 수 있었다. 따라서 코팅층의 파괴를 방지하기 위해서는 코팅층과 기판층간의 mismatch와 사용환경(가해지는 하중)을 고려한 적정 임계두께늬 설계가 요구된다.

  • PDF

KL-510 하중모형을 적용한 강합성 2거더교 RC 장지간 바닥판의 최소두께 (Minimum Thickness of Long Span RC Deck Slabs for Composite 2-girder Bridges Designed by KL-510 Load Model)

  • 박우진;황훈희
    • 한국안전학회지
    • /
    • 제29권3호
    • /
    • pp.72-78
    • /
    • 2014
  • The minimum thickness of long-span deck slab is proposed by checking the limit state according to the Korean highway bridge design code(limit state design). Both minimizing thickness and ensuring safety of deck slab are important design factors to increase a competitive price of the long span deck slabs. The required thicknesses for satisfying flexural capacity, preventing punching shear failure and limiting deflection were calculated by considering KL-510 load model which has increased total load compared to DB 24 from 432 kN to 510 kN. The results of the required thickness for various limit states were compared to propose the minimum thickness as a function of span length of deck slabs. The proposed minimum thickness is influenced by satisfying flexural capacity and limiting deflection. It turns out to be similar compared to the results of the previous study by ultimate strength design method even if the live load model was increased in total weights.

한국 성인의 각화치은 두께측정에 관한 연구 (A Study on Keratinized Gingival Thickness in Healthy Korean Adults)

  • 강철흔;장문택;류성훈;김형섭
    • Journal of Periodontal and Implant Science
    • /
    • 제30권1호
    • /
    • pp.179-187
    • /
    • 2000
  • The objectives of this study were to measure keratinized gingival thickness in healthy Korean adults, and to correlate the keratinized gingival thickness with width of keratinized gingiva, probing pocket depth and gingival recession.Thickness measurements were performed in 37 Korean dental students using an ultrasonic device(SDM). Width of keratinized gingiva, gingival recession and probing pocket depth were measured with a Williams periodontal probe.The results showed that the keratinized gingival thickness varied from 0.83 mm(canines) to 1.16 mm(central incisors) in the maxilla and, in the mandible, from 0.68 mm(1st premolars) to 1.69 mm(2nd molars). In a stepwise multiple linear regression analysis, 23% of variation of gingival thickness could be explained by width of keratinized gingiva and probing pocket depth. It could be concluded that the keratinized gingival thickness depends on tooth type and correlates with width of keratinized gingiva and probing pocket depth.

  • PDF

Effect of LiCoO2 Cathode Density and Thickness on Electrochemical Performance of Lithium-Ion Batteries

  • Choi, Jaecheol;Son, Bongki;Ryou, Myung-Hyun;Kim, Sang Hern;Ko, Jang Myoun;Lee, Yong Min
    • Journal of Electrochemical Science and Technology
    • /
    • 제4권1호
    • /
    • pp.27-33
    • /
    • 2013
  • The consequences of electrode density and thickness for electrochemical performance of lithium-ion cells are investigated using 2032-type coin half cells. While the cathode composition is maintained by 90:5:5 (wt.%) with $LiCoO_2$ active material, Super-P electric conductor and polyvinylidene fluoride polymeric binder, its density and thickness are independently controlled to 20, 35, 50 um and 1.5, 2.0, 2.5, 3.0, 3.5 g $cm^{-3}$, respectively, which are based on commercial lithium-ion battery cathode system. As the cathode thickness is increased in all densities, the rate capability and cycle life of lithium-ion cells become significantly worse. On the other hand, even though the cathode density shows similar behavior, its effect is not as high as the thickness in our experimental range. This trend is also investigated by cross-sectional morphology, porosity and electric conductivity of cathodes with different densities and thicknesses. This work suggests that the electrode density and thickness should be chosen properly and mentioned in detail in any kinds of research works.

지르코니아 단일구조 전부도재관의 파절강도 (FRACTURE STRENGTH OF ZIRCONIA MONOLITHIC CROWNS)

  • 정희찬
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.157-164
    • /
    • 2006
  • Purpose: The purpose of this study was to compare the fracture strength of the zirconia monolithic all-ceramic crowns according to the thickness(0.5 mm, 0.8 mm, 1.1 mm) and IPS Empress II ceramic crown of 1.5 mm thickness. Material and method: Eight crowns for each of 3 zirconia crown groups were fabricated using CAD/CAM system(Kavo, Germany) and eight Empress II crowns were made from silicone mold and wax pattern. Each crown group was finished in accordance with the specific manufacturer s instruction. All crowns were luted to the metal dies using resin cement and mounted on the testing jig in a universal testing machine. The load was directed at the center of crown with perpendicular to the long axis of each specimen until catastrophic failure occurred. Analysis of variance and Tukey multiple comparison test(p<.05) were applied to the data. Results and Conclusion: 1. The fracture strength of the zirconia monolithic all-ceramic crown was higher thickness increased(p<.05). 2 The fracture strength of 1.1 mm thickness zirconia monolithic all-ceramic crown was higher than the fracture strength of 1.5 mm thickness IPS Empress II crown(p<.05). 3. The fracture strength of 0.5 mm thickness zirconia monolithic all-ceramic crown exceeded maximum occlusal forces.

두께에 따른 생체 모방 종이 작동기의 성능평가 (The Performance of EAPap Actuators with Thickness Variation)

  • 송춘석;김재환;강유근;윤성률
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계학술대회논문집
    • /
    • pp.735-738
    • /
    • 2005
  • Electro-Active Paper (EAPap) is attractive as an EAP actuator material due to its merits in terms of lightweight, dry condition, large displacement output, low actuation voltage and low power consumption. This paper presents the performance of EAPap actuators with thickness variation. The EAPap is made with cellulose paper, and is shown to bend in response to an external electric field. Up to the present, we have tested displacement, current and force of EAPap with 20 $\mu$m thickness. The thickness of EAPap is important factor that affects the performance of the actuator. Therefere, three different thickness of EAPap, 20, 30, and 40 $\mu$m are investigated that inference the tip displacement, blocked force, the resonance and the actuator efficiency. There is an optimum thickness of EAPap, which is resulted from the stiffness and the mass. The performance of EAPap with thickness is discussed.

  • PDF

MDCT에서 절편두께에 따른 Noise 측정 (Measurement of the Noise according to the Slice Thickness in MDCT)

  • 문일봉;동경래;김미현;최성현;권대철;구은회
    • 방사선산업학회지
    • /
    • 제11권3호
    • /
    • pp.151-155
    • /
    • 2017
  • MDCT is used to determine how the noise changes as the slice thickness changes. Noise according to thickness of 1.5, 3.0, 5.0 and 10.0 mm was analyzed using the Siemens (Somatom Definition Flash, Germany) equipment and calibration conditions such as tube voltage and tube current using the calibration QC phantom. 1.5, 3.0, 5.0 and 10.0 mm, respectively. The mean HU was 1.5 mm (7.7 HU), 3.0 mm (4.9 HU) and was reduced by 59.5% from 1.5 mm. 5.0 mm (3.9 HU) and 97.6% compared to 1.5 mm, 10.0 mm (3.1 HU) and 148% less than 1.5 mm. It was found that as slice thickness increased, noise decreased, while slice thickness decreased. In conclusion, setting the appropriate slice thickness for each site may be useful for obtaining appropriate noise and image quality.

Comparison of Injection Molding Characteristics according to Thickness Variations of Preform for PET bottle

  • Kim, Nam Hyun;Woo, In Young;Nam, Kyung Woo;Yeon, Baek Rim;Kim, Mi Rae;Lyu, Min-Young
    • Elastomers and Composites
    • /
    • 제56권3호
    • /
    • pp.164-171
    • /
    • 2021
  • Due to the problem of environmental pollution by plastics, it is necessary to decrease their consumption. In the case of PET bottles, it is essential to reduce the thickness of the bottle for the reduction of plastic used. For manufacturing PET bottles with reduced thickness, it is a prerequisite to design a preform with reduced thickness and study its molding capability. In this study, the injection molding capability was investigated after reducing the body thickness of the preform to 15% and 20%, respectively, for the two preform models currently in use. Injection molding analysis was performed on the existing models and on the models for reduced weight, under the molding conditions of the existing models. Using the computed results, temperature distribution, pressure distribution, deformation and clamping force were compared. Based on the analysis, the injection conditions of the preform model with less thickness were discussed.