• 제목/요약/키워드: TEST BED

Search Result 1,630, Processing Time 0.032 seconds

Performance Evaluation of the Tip-tilt Actuator in Fast Steering Secondary Mirror for Large Telescope (대형 망원경용 FSM(Fast Steering Secondary Mirror)을 위한 팁틸트 액츄에이터의 성능평가)

  • Kim, Ho Sang;Lee, Dong-Chan;Lee, Kyoung-Don;Kim, Young-Soo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.31 no.5
    • /
    • pp.403-409
    • /
    • 2014
  • For ground-based telescope application, the performance assessment of tip-tilt actuator is important because the optical quality of telescope depends upon the windshake compensation ability of the fast steering secondary mirror. But it is difficult to measure the performance characteristics of the actuators due to the large size mirror and test facilities including the vacuum support and structural frame. In this paper, the full-scale tip-tilt test bed for the large size secondary mirror with diameter of 1m is built and the several tests are performed including the range, resolution and frequency response function. From the measurement results, it is shown that the tip-tilt actuator can successfully compensate the windshake with frequency of maximum 12 Hz and be a candidate for the Giant Magellan Telescope.

Effect of Positioning on Back Pain and Comfort of Bed Rest Patients after Transhepatic Arterial Chemoembolization (체위변경이 간동맥 화학색전술 후 침상안정기 환자의 요통과 안위에 미치는 효과)

  • Park Han-Jong;Sohng Kyeong-Yae
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.12 no.3
    • /
    • pp.317-324
    • /
    • 2005
  • Purpose: The study was done to investigate whether positioning relieves the back pain and enhances comfort during bed rest after transhepatic arterial chemoembolization(TACE). Methods: A quasi-experimental design with non-equivalent control group non-synchronized design was used. The experimental group was placed semi Fowler's position for the first 2 hours. The following 4 hours the position was rotated hourly between 30 degrees laterally inclined position and a semi Fowler's position. The control group was maintained in a supine position for the 6 hours. Data were analyzed using t-test, $x^2$-test, Fisher's exact test and repeated measures ANOVA. Results: 1) Back pain intensity significantly decreased in the experimental group compared to the control group. 2) Comfort level significantly decreased in both groups, but there was no significant difference between the two groups. 3) There were no hematoma and bleeding complication in either group. In addition, there was no significant difference in urinary retention between the two groups. 4) Analgesics were less frequently taken by the experimental group. Conclusion: These results suggest that positioning relieves back pain without causing an increased incidence of hematoma and bleeding formation after TACE and this nursing intervention might help patients be more comfortable during the treatment of TACE.

  • PDF

A Tentative Methodology for Quality Control of Trackbed Fills Using Field and Laboratory P-Wave Measurements

  • Park, Chul-Soo;Park, In-Beom;Kim, Eun-Jung;Mok, Young-Jin
    • International Journal of Railway
    • /
    • v.1 no.2
    • /
    • pp.64-71
    • /
    • 2008
  • The quality of track-bed fills of railways has been controlled by field measurements of density $({\gamma}_d)$ and the results of plate-load tests. The control measures are compatible with the design procedures whose design parameter is $k_{30}$ for both ordinary-speed railways and high-speed railways. However, one of fatal flaws of the design procedures that there are no simple laboratory measurement procedures for the design parameters ($k_{30}$ or, $E_{v2}$ and $E_{v2}/E_{v1}$) in design stage. A new quality control procedure, in parallel with the advent of the new design procedure, is being proposed. This procedure is based upon P-wave velocity involving consistently the evaluation of design parameters in design stage and the field measurements during construction. The Key concept of the procedure is that the target value for field compaction control is the P-wave velocity determined at OMC using modified compaction test, and direct-arrival method is used for the field measurements during construction. The procedure was verified at a test site and the p-wave velocity turned out to be an excellent control measure. The specifications for the control also include field compaction water content of OMC${\pm}$2% as well as the p-wave velocity.

  • PDF

Design and Fabrication of Tool Change Multi-nozzle FDM 3D Printer (툴 체인지 방식 멀티 노즐 3D프린터의 설계 및 제작)

  • Suk, Ik-hyun;Park, Jong-kyu
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.2
    • /
    • pp.38-44
    • /
    • 2021
  • To cater to the transition from single-color to multicolor/multi-material printing, this paper proposes a cartridge-replacing type multi-nozzle Fused Depositon Modeling(FDM) three-dimensional (3D) printer. In the test printing run, tool change failure/wobble/layer shift occurred. It was confirmed that improper support was the cause of this tool change failure. As a solution, spline and electromagnetic cartridges were designed. Wobble was caused by machine vibration and the motor stepping out. To minimize wobble, an additional Z-axis was installed, and the four-point bed leveling method was used instead of the three-point bed leveling method. The occurrence of layer shift was ascribed to the eccentricity of the Z-axis lead screw. Therefore, slit coupler was replaced with an Oldham type. In addition to the mechanical supplementation, the control environment was integrated to prevent accidents and signal errors due to wire connections. Before the final test printing run, a rectifier circuit was added to the motor to secure precise control stability. The final test printing run confirmed that the wobble/layer shift phenomenon was minimized, and the maximum error between layers was reduced to 0.05.

Virus Test bed using VMware in Preparation for the Mobile IP Generation (Mobile IP 세대를 대비한 VMware 기반의 바이러스 Test bed)

  • Kim, Hong-Il
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.1
    • /
    • pp.56-63
    • /
    • 2009
  • Contrast operating system installed on traditional PC, operating system installed to mobile IP host is a status not to be established a definite monopoly system. Accordingly, for the time being, it is expected that operating system operated in mobile IP host will be used various operating systems. Regardless of operating system, this condition is a very vulnerable to modified virus. Because operating system used in an individual host is very diverse, It makes technical development to cure complicated in detection efficiently these virus. In this thesis, By using VMware under the various operating system, I designed and implemented system which is able to test a modified virus. Also I implemented prototype system to operate under the real mobile condition.

Commercial ECU-Based Test-Bed for LIN-CAN Co-Analysis and Proof on Ultrasonic Sensors through Physical Error Injection (실차기반 LIN-CAN 연계 통합 분석 테스트베드 개발과 초음파센서 물리적 오류주입 및 분석을 통한 효용성 검증)

  • Yoon-ji Kim;Ye-ji Koh;In-su Oh;Kang-bin Yim
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.33 no.2
    • /
    • pp.325-336
    • /
    • 2023
  • With the development of autonomous driving technology, the number of external contact sensors mounted on vehicles is increasing, and the importance is also rising. The vehicular ultrasonic sensor uses the LIN protocol in the form of a bus topology and reports a status message about its surroundings through the vehicle's internal network. Since ultrasonic sensors are vulnerable to various threats due to poor security protocols, physical testing on actual vehicle is needed. Therefore, this paper developed a LIN-CAN co-analysis testbed with a jig for location-specific distance test to examine the operational relation between LIN and CAN caused by ultrasonic sensors.

Spot Cooling System Development for Ever-bearing Strawberry by Using Low Density Polyethylene Pipe (연질 PE관을 이용한 여름딸기 부분냉방기술 개발)

  • Moon, Jong Pil;Kang, Geum Choon;Kwon, Jin Kyung;Lee, Su Jang;Lee, Jong Nam
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.56 no.6
    • /
    • pp.149-158
    • /
    • 2014
  • The effects of spot cooling on growing ever-bearing strawberry in hydroponic cultivation during summer by spot cooling system was estimated in plastic greenhouse located in Pyeongchang. The temperature of cooling water was controlled by heat pump and maintained at the range of $15{\sim}20^{\circ}C$. Cooling pipes were installed in root zone and very close to crown. Spot cooling effect was estimated by applying system in three cases which were cooling root zone, crown plus root zone, and crown only. White low density polyethylene pipe in nominal diameter of 16 mm was installed on crown spot, and Stainless steel flexible pipe in nominal diameter of 15A was installed in root zone. Crown and root zone cooling water circulation was continuously performed at flowrates of 300 ~ 600 L/hr all day long. Strawberry yields by test beds were surveyed from Aug. 1 to Sep. 30. The accumulated yield growth rate compared with a control bed of crown cooling bed was 25 % and that of crown plus root zone cooling bed was 25 % and that of root zone cooling bed was 20 %. The temperatures of root spot in root zone cooling was maintained at $18{\sim}23.0^{\circ}C$ and that of crown spot in crown cooling was maintained at $19{\sim}24^{\circ}C$. Also, the temperatures of root spot in crown plus root zone cooling bed was maintained at $17.0{\sim}22.0^{\circ}C$ and that of crown spot was maintained at $19{\sim}25^{\circ}C$.

Effects of Nurse Staffing Level on In-hospital Mortality and 30-day Mortality after Admission using Korean National Health Insurance Data (간호사 확보수준이 입원 환자의 병원사망과 입원 30일 이내 사망에 미치는 영향)

  • Kim, Yunmi;Lee, Kyounga;Kim, Hyun-Young
    • Journal of Korean Clinical Nursing Research
    • /
    • v.28 no.1
    • /
    • pp.1-12
    • /
    • 2022
  • Purpose: The purpose of this study is to investigate the association between the nurse staffing level and the patient mortality using Korean National Health Insurance data. Methods: The data of 1,068,059 patients from 913 hospitals between 2015 and 2016 were analyzed. The nurse staffing level was categorized based on the bed-to-nurse ratio in general wards, intensive care units (ICUs), and hospitals overall. The x2 test and generalized estimating equations (GEE) multilevel multivariate logistic regression analyses were used to explore in-hospital mortality and 30-day mortality after admission. Results: The in-hospital mortality rate was 2.9% and 30-day mortality after admission rate was 3.0%. Odd Ratios (ORs) for in-hospital mortality were statistically lower in general wards with a bed-to-nurse ratio of less than 3.5 compared to that with 6.0 or more (OR=0.72, 95% CI=0.63~0.84) and in ICUs with a bed-to-nurse ratio of less than 0.88 compared to that with 1.25 or more (OR=0.78, 95% CI=0.66~0.92). ORs for 30-day mortality after admission were statistically lower in general wards with a bed-to-nurse ratio of less than 3.5 compared to that with 6.0 or more (OR=0.83, 95% CI=0.73~0.94) and in ICUs with a bed-to-nurse ratio of less than 0.63 compared to that with 1.25 or more (OR=0.85, 95% CI=0.72~1.00). Conclusion: To reduce the patient mortality, it is necessary to ensure a sufficient number of nurses by improving the nursing fee system according to the nurse staffing level.

A study on breakthrough characteristics of ion exchange bed with H- and ETAH-form resins for cation exchange in NH3 and ETA solution including trace NaCl (미량의 NaCl을 포함하는 NH3 및 ETA 용액에서 H 및 ETAH 형 수지에 대한 이온교환 파과 특성 연구)

  • Ahn, Hyun-Kyoung;Kim, Youn-Su;Park, Byung-Gi;Rhee, In-Hyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.35 no.6
    • /
    • pp.533-544
    • /
    • 2021
  • Ion exchange (IX) performance on the exchanger bed is essentially evaluated for the generation of ultrapure water in electronics and chemical industries and for the corrosion control in nuclear power plants. The breakthrough characteristics of IX bed with multi-component were investigated with both cation- and mixed-IX beds of H- and ETAH-form for four kinds of cation exchange resins by using the combined solution of ethanolamine (ETA) and ammonia (NH3) at trace NaCl. Unlike major components (ETAH+ and NH4+ ), the phenomena of breakthrough and overshooting at bed outlet were not observed by Na+ over the test period (> 3 times theoretical exchange capacity of IX bed). The breakthrough from H-form resin bed was sequentially reached by ETAH+ and NH4+, while the overshooting was observed for ETAH+ at the breakthrough of NH4+. NH4+ was 51.5% higher than ETAH+ in terms of the relative selectivity determined with the width of breakthrough zone. At the increased concentration of Na+ at bed inlet, the selectivity and the overshooting were decreased and increased, respectively. Na+ leakage was higher from ETAH-form resin bed and was not identical for four kinds of cation-exchange resins, which may be reduced by improving the intrinsic property of IX resin.

Development of a Test Facility for Cold-air Performance of Small Axial Turbine (소형 축류터빈의 상온 성능시험기 개발)

  • 손창민;차봉준;이대성
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.7
    • /
    • pp.1780-1786
    • /
    • 1995
  • The main goal of the present study is to establish the techniques and methodolgies of turbine performance test through evaluating the objective turbine test piece, and checking the reliability of the self-developed test facility by performing a series of turbine tests under ambient temperature condition. A high speed coupling, a lubrication system and a test bed of the test facility were modified through a series of preliminary test in order to reduce the vibration and oil leakage. The flowrate control of the test facility and data acquisition were accomplished by using a software called "Labview" The measurement of shaft horse power and control of rotational speed according to the conditions of turbine rotation were performed by a separate system. The preliminary evaluation of the measured data suggests that the developed test facility and the test technique can be used reliably for the performance test of turbines with the minor improvement.provement.