• Title/Summary/Keyword: TC10

Search Result 2,129, Processing Time 0.031 seconds

Optimal Design and fabrication of Prototype DC Reactor for Inductive Superconducting fault Current Limiter (유도형 고온초전도 한류기용 Prototype 직류 리액터의 설계와 제작)

  • 김태중;강형구;고태국
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1292-1298
    • /
    • 2003
  • In this paper, dc reactor lot the inductive high-Tc superconducting fault current limiter (SFCL) was optimally designed by finite element method(FEM). The Prototype high-Tc do reactor was manufactured and compared to the results of design. This dc reactor consists of 4∼stacked double pancake coils which are wounded with Bi-2223 wire coated with SUS315L. Kapton tape is used for the insulation of turn to turn and layer to layer. Each pancake is connected in series by soldering Finally, optimal design and manufacture method lot the dc reactor is suggested in this paper. Through the comparison of result of optimal design and experimental result of prototype high-Tc superconducting dc reactor, reliance on the design of the high-Tc dc reactor tot the 1.2 kV/80 A SFCL is proved.

Significant Reperfusion on $^{99m}Tc-HMPAO$ SPECT in a Case of Subacute MCA Infarction (한의학적 치료로 $^{99m}Tc-HMPAO$ SPECT상 현저한 재관류를 보인 아급성기 중대뇌동맥경색 환자 1례)

  • Park, Jung-Mi;Jung, Woo-Sang;Seo, Al-An
    • The Journal of Internal Korean Medicine
    • /
    • v.22 no.3
    • /
    • pp.437-442
    • /
    • 2001
  • For ischemic cerebrovascular disease, it is well known that early luxury perfusion is related to a good clinical outcome and single photon emission computed tomography(SPECT) has the potential for providing useful information about regional cerebral blood flow. We report one case of Rt. MCA infarction mainly treated by oriental medicine and revealed luxury perfusion without thrombolysis. In acute stage, neurological deficits of the patient were very severe. 99mTc-HMPAO SPECT images obtained 10days after the attack showed large perfusion defect in the Rt. MCA territory. We followed up 99mTc-HMPAO SPECT 40days after the ictus. Despite of the poor early perfusion, we found considerably improved perfusion and neurological improvement.

  • PDF

The Electrical Insulation Design of 600kJ Conduction Cooled HTS SMES (600kJ 전도냉각 고온초전도 SMES의 전기절연 설계)

  • Choi, Jae-Hyeong;Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Min, Chi-Hyun;Kim, Hae-Jong;Seong, Ki-Chul;Kim, Sang-Hyun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.9 no.3
    • /
    • pp.67-71
    • /
    • 2007
  • The electrical insulation design of 600 kJ conduction cooled high-Tc superconducting magnetic energy storage (SMES) have been studied in this paper. The high voltage is applied to both ends of magnet of high-Tc SMES by quench or energy discharge. Therefore. the insulation design of the high voltage needs for commercialization. stability. reliability and so on. In this study. we analyzed the insulation composition of a high-Tc SMES. and investigated about the insulation characteristics of the materials such as Kapton. AIN. $Al_2O_3$. GFRP and vacuum in cryogenic temperature. Base on these results. the insulation design for 600 kJ conduction cooled high-Tc SMES was performed.

'Triangular Cord' Sign in Biliary Atresia (담도폐쇄증에서 'Triangular Cord' Sign)

  • Hee Jung Lee;Mu Sook Lee;Jin Young Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.5
    • /
    • pp.1003-1013
    • /
    • 2022
  • Biliary atresia is an unknown etiology of extrahepatic bile duct obstruction with a 'fibrous ductal remnant,' which represents the obliterated ductal remnant in the porta hepatis. The sonographic 'triangular cord' (TC) sign has been reported to indicate a fibrous ductal remnant in the porta hepatis. In this review, we discuss the correlations among surgicopathological and sonographic findings of the porta hepatis and the definition, objective criteria, diagnostic accuracy, and differential diagnosis of the TC sign in biliary atresia.

Assessment of the Synovial Inflammation in Rheumatoid Arthritis with $^{99m}Tc$-labelled Polyclonal Human IgG(HIG): Prospective Comparison with Gadolinium Enhanced MRI ($^{99m}Tc$-labelled HIG 스캔을 이용한 류마티스 관절염 환자에서 활막염증의 평가 : 조영증강 자기공명영상과의 전향적인 비교)

  • Ryu, Young-Hoon;Lee, Jong-Doo;Suh, Jin-Suck;Park, Chang-Yun;Jeon, Pyoung;Na, Jae-Beom;Lee, Soo-Kon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.84-91
    • /
    • 1995
  • Many clinical and laboratory tests have been employed to evaluate disease activity in rheumatioid arthritis. $^{99m}Tc$-labelled polyclonal IgG(HIG) has been demonstrated to accumulate in focal sites of infection or inflammation in both animals and human subjects. The purpose of this study was to distinguish arthritis with active inflammation from those without active inflammation and to correlate relative intensities of $^{99m}Tc$-labelled HIG uptake of the rheumatoid arthritis with clinical and MR indices of the joint inflammation. This study included twelve patients with active rheumatoid arthritis, two with ankylosing spondylitis and one with degenerative osteoarthritis without active inflammation. A Whole-body and spot images were obtained 4 hours after intravenous injection of 20mCi of $^{99m}Tc$-labelled HIG. Scintigrams were assessed visually by 3 experienced radiologists, and graded as normal or mildly and markedly increased uptake within the joints, and the degree of uptake was compared with clinical and radiologic severity of synovial inflammation. MRI studies were done on the involved joints consisted of wrist(n = 11), knee(n = 2) and hip joint(n= 2). Active synovitis was defined when marked elevation of ESR and gadolinium enhancement of synovium on MRI were demonstrated. Markedly increased radiotracer uptake was seen in 10 of 11 rheumatoid arthritic patients with active synovitis whereas normal or mildly increased uptakes were noted in others, including rheumatoid arthritic patient(n=1) and non-rheumatoid patients(n = 3) without active synovitis. This study showed that the localization of involved joints in rheumatoid arthritis could be detected with $^{99m}Tc$-labelled HIG and that the degree of uptake correlated well with the degree and activity of inflammation. In conclusion, $^{99m}Tc$-labelled HIG scan is a useful method in the evaluation of active inflammation in rheumatoid arthritis.

  • PDF

$^{99m}Tc$ Labeling Kit Preparation and Characteristics of Anti-NCA-95 Monoclonal Antibody (항 NCA-95 단일클론항체의 $^{99m}Tc$표지 키트 제조 및 특성 연구)

  • Hong, Mee-Kyoung;Jeong, Jae-Min;Chung, June-Key;Choi, Seok-Rye;Kim, Chae-Kyun;Lee, Yong-Jin;Lee, Dong-Soo;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.30 no.4
    • /
    • pp.541-547
    • /
    • 1996
  • The previous monoclonal antibody labeling method for bone marrow immunoscintigrapy was complicated and laborious for clinical application. Also it showed a relatively low labeling efficiency. To improve this procedure, we compared several direct labeling methods of $^{99m}Tc$. 1) The labeling efficiency in the method using gluconate as a transchelator was low (40-70%), but immunoscintigraphy using this radiotracer produced a clear image. 2) To improve labeling efficiency, ${\beta}$-mercaptoethanol was removed after reduction. The labeling efficiency was improved up to 70-80%, but the radioactivity of the blood pool was high. 3) The higest labeling efficiency (>90%) and best quality images could be obtained by using MDP as a transchelating agent. It did not require additional procedures for separation of labeled antibodies. The immunoreactivity of this antibody was 60%. Residual MDP which can be taken up by the bone could be removed by PD-10 column. The reduced antibodies were stable with a high labeling efficiency (>90%) for up to 47 days by deep freezing. We concluded that the improved procedure for $^{99m}Tc$ labeling of anti-NCA-95 monoclonal antibody using MDP as a transchelating agent will be a simple and useful method for clinical application.

  • PDF

Normal Limits of Left Ventricular Volumes and Ejection Fraction Measured by Gated Myocardial Perfusion SPECT: Comparison of Tc-99m MIBI and Tl-201 (심근 게이트 SPECT로 측정한 좌심실 용적과 구혈률의 정상 값 확립: Tl-201과 Tc-99m MIBI 게이트 SPECT의 비교)

  • Hyun, In-Young;Seo, Jeong-Kee;Kwan, Jun;Park, Keum-Soo;Choe, Won-Sick;Lee, Woo-Hyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.37 no.3
    • /
    • pp.147-152
    • /
    • 2003
  • Purpose: We evaluated radioisotope and sex-specific differences of normal limits for left ventricle volumes (LWs) and ejection fraction (EF) using myocardial perfusion gated SPECT (g-SPECT). Materials and Methods: Rest Tl-201/post-stress Tc-99m MIBI g-SPECT measurements with acquisitions of 8-frame were evaluated for 70 patients (mean age $55{\pm}14.56%$ female) who either had < 10% pretest likelihood of CAD (n = 12) or had normal coronary angiography (EF > 50%) (n = 58). LVEF, LWs were automatically determined by quantitative gated SPECT using QGS program. Results: Similar results were obtained for mean LVEF between Tc-99m MIBI ($62%{\pm}7%$ and Tl-201 ($63%{\pm}8%$) g-SPECT measurements. In Contrast, Tl-201 g-SPECT had significantly lower LWs values ($EDV;\;74{\pm}23mL,\;ESV;\;28{\pm}14mL$) than Tc-99m MIBI g-SPECT ($EDV;\;82{\pm}25mL,\;ESV;\;32{\pm}15mL$) (p<0.05). Women had significantly lower EDV ($Tc-99m\;MIBI;\;71{\pm}18mL,\;Tl-201;\;65{\pm}17mL$), and ESV values ($Tc-99m\;MIBI;\;27{\pm}10mL,\;Tl-201;\;23{\pm}8mL$) compared with EDV ($Tc-99m\;MIBI;\;96{\pm}27mL,\;Tl-201;\;85{\pm}24mL$), and ESV Values ($Tc-99m\;MIBI;\;40{\pm}17mL,\;Tl-201;\;36{\pm}16mL$) of men (p<0.05). Women had significantly higher LV EF Values ($65%{\pm}7%$) than men ($60%{\pm}8%$) by Tl-201 gated SPECT (p<0.05). Conclusion: These data suggest significant differeuces in normal limits for LWs and EF, according to genders and radiopharmaceutical. Therefore, the evaluation of cardiac function in patients should consider radioisotope and sex-matched normal values.

Radioimmunoimaging with Mixed Monoclonal Antibodies of Nude Mice Bearing Human Lung Adenocarcinoma Xenografts

  • Duan, Dong;Li, Shao-Lin;Zhu, Yu-Quan;Zhang, Tao;Lei, Cheng-Ming;Cheng, Xiang-Hua
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4255-4261
    • /
    • 2012
  • The present study was conducted to evaluate radioimmunoimaging (RII) and in vivo distribution of mixed antibodies $^{99m}Tc$-EGFR-mAb and $^{99m}Tc$-CD44-mAb in nude mice bearing human lung adenocarcinoma xenografts. Single and mixed applications of the two radiolabeled monoclonal antibodies (mAbs) were compared. Direct labeling of $^{99m}Tc$ was applied to radiolabel the EGFR and CD44 mAbs. The properties of the radiolabeled antibodies were then characterized. RII and assessment of the distribution of the antibodies in nude mice bearing lung adenocarcinoma xenografts were achieved by applying separate and combined doses of $^{99m}Tc$-EGFR-mAb and $^{99m}Tc$-CD44-mAb. The labeling rates of $^{99m}Tc$ for EGFR-mAb and CD44-mAb were $91.5%{\pm}3.8%$ and $92.3%{\pm}4.1%$ respectively, with specific activities of 2.8 and $2.9MBq/{\mu}g$, respectively, and radiochemical purities (RCP) of 96.5% and 96.2%. The radioactivity uptake of the combined application of both radiolabeled antibodies was clearly higher than with a single application of either alone. The relative values of target-to-nontarget (T/NT) measured through the regional interest (ROI) technique were $5.59{\pm}0.42$ (mixed antibodies), $2.78{\pm}0.20$ ($^{99m}Tc$-EGFR-mAb), and $2.28{\pm}0.16$ ($^{99m}Tc$-CD44-mAb) in the RII. The body distribution of the radiolabeled antibodies and their imaging results were basically identical. Application of the mixed antibodies with $^{99m}Tc$-EGFR-mAb and $^{99m}Tc$-CD44-mAb can increase the radioactivity uptake of tumor tissue, leading to more ideal target-to-nontarget ratios, and therefore superior results.

Analyzing Effective Thermal Conductivity of Rocks Using Structural Models (구조모델을 이용한 암석의 유효열전도도 분석)

  • Cha, Jang-Hwan;Koo, Min-Ho;Keehm, Young-Seuk;Lee, Young-Min
    • Economic and Environmental Geology
    • /
    • v.44 no.2
    • /
    • pp.171-180
    • /
    • 2011
  • For 21 rock samples consisting of granite, sandstone and the effective thermal conductivity (TC) was measured with the LFA-447 Nanoflash, and mineralogical compositions were also determined from XRD analysis. The structural models were used to examine the effects of quartz content and the size of minerals on TC of rocks. The experimental results showed that TC of rocks was strongly related to quartz content with $R^2$ value of 0.75. Therefore, the proposed regression model can be a useful tool for an approximate estimation of TC only from quartz content. Some samples with similar values of quartz content, however, illustrated great differences in TC, presumably caused by differences in the size of minerals. An analysis from structural models showed that TC of rocks with fine-grained minerals was likely to fall in the region between Series and EMT model, and it moved up to ME and Parallel model as the size of minerals increased. This progressive change of structural models implies that change of TC depending on the size of minerals is possibly related to the scale of experiments; TC was measured from a disk sample with a thickness of 3 mm. Therefore, in case of measurements with a thin sample, TC can be overestimated as compared to the real value in the field scale. The experimental data illustrated that the scale effect was more pronounced for rocks with bigger size of minerals. Thus, it is worthwhile to remember that using a measured TC as a representative value for the real field can be misleading when applied to many geothermal problems.

Adenosine $^{99m}Tc-MIBI$ Scintigraphy in the Diagnosis of Coronary Artery Disease: Comparison with Exercise $^{99m}Tc-MIBI$ Scintigraphy (관상동맥 질환에서의 Adenosine 부하 $^{99m}Tc-MIBI$ 심근 스캔의 진단적 가치 : 운동 부하 $^{99m}Tc-MIBI$ 심근 스캔과의 비교)

  • Kang, Seung-Wan;Woo, Eon-Jo;Chae, Sung-Chull;Jun, Jae-Eun;Park, Wee-Hyun;Chung, Byung-Cheon;Choi, Chung-Il;Lee, Jae-Tae;Lee, Kyu-Bo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.26 no.1
    • /
    • pp.72-81
    • /
    • 1992
  • Pharmacologic coronary vasodilation in conjunction with myocardial scintigraphy has become an accepted alternative to dynamic exercise testing for the diagnosis of coronary artery disease. Although dipyridamole has traditionally been used for this purpose, it causes frequent side effect, which at times can be life-threatening. Moreover, dipyridamole dose not elicit maximal coronary vasodilation in a substantial number of patients receiving the usual i.v. dose. Adenosine is an endogenously produced compound that has significant effects as a coronary vasodilator and rapid onset action and extremely short half-life (< 10 seconds). The diagnostic accuracy and safety profile of adenosine $^{99m}Tc-MIBI$ myocardial scintigraphy were evaluated and comparison with exercise $^{99m}Tc-MIBI$ was performed. Twenty-eight subjects underwent $^{99m}Tc-MIBI$ imaging after adenosine infusion and exercise $^{99m}Tc-MIBI$ imaging. Adenosine was infused intravenously at a dose of 0.14mg/kg/body weight per minute for 6 min and MIBI was injected at 3 minute. Adenosine caused an incerease in heart rate ($64{\pm}12$ at baseline versus $74{\pm}16$ beats/min at peak effect, p<0.001), a mild decrease in systolic and diastolic blood pressure and a slightly increase in PR interval(p; NS). Side effects were reported in 92% of patients and were mostly mild in nature and promptly resolved within 1 or 2 minutes of termination of adenosine infusion. Facial flushing (53%), chest pain (36%), mild dyspnea (39%), headache (21%), throat discomfort (21%) were frequent symptoms. ST segment depression (> 1 mm) and second degree AV block in electrocardiography occured in 11% of the patients, respectively. The overall sensitivity and specificity for individual coronary stenoses in 16 patients underwent coronary angiography were 88% and 95%, respectively. The agreement ratio of segmental perfusion between adenosine and exercise images was 92% (Kappa index=0.82). In conclusion, $^{99m}Tc-MIBI$ myocardial perfusion scintigraphy with intravenous adenosine is a feasible, safe and highly accurate noninvasive technique for the detection of coronary artery disease and results are at least comparable with those of exercise $^{99m}Tc-MIBI$ scintigraphy.

  • PDF