• Title/Summary/Keyword: TC10

Search Result 2,124, Processing Time 0.032 seconds

The Effects of Trunk Control Ability on Balance, Gait, and Functional Performance Ability in Patients With Stroke (뇌졸중 환자의 체간 조절 수준이 균형과 보행 및 기능적 수행 능력에 미치는 영향)

  • An, Seung-Heon;Chung, Yi-Jung;Park, Sei-Yeon
    • Physical Therapy Korea
    • /
    • v.17 no.2
    • /
    • pp.33-42
    • /
    • 2010
  • The aim of this study was to investigate correlations of the Trunk Control Test (TCT), Postural Assessment Scale for Stroke (PASS-TC), and Trunk Impairment Scale (TIS) and to compare the TCT, PASS-TC, TIS and its subscales in relation to balance, gait and functional performance ability after stroke. Sixty-two stroke patients attending a rehabilitation program participated in the study. Trunk control was measured with the use of TCT, PASS-TC, TIS balance (Berg Balance scale; BSS), gait ability (10 m walk test), functional performance ability (Tuned Up and Go Test TUG) and the mobility part of the Modified Barthel index (MBI), Fugl Meyer-Upper/Lower Extremity ($FM-U{\cdot}L/E$), The scatter-plot (correlation coefficient) was composed for the total scores of the TCT, PASS-TC, and TIS. The multiple regression analysis was performed to evaluate the impact of trunk control on balance, gait, and functional performance ability. Twenty eight participants (45.2%) and twenty participants (32.3%) obtained the maximum score on the TCT and PASS-TC respectively; no subject reached the maximum score on the Trunk Impairment Scale. There were significant correlations between the TIS and TCT (r=.38, p<.01), PASS-TC (r=.30, p<.05), TCT and PASS-TC (r=.59, p<.01). Stepwise multiple regression analysis showed that the BBS score (${\beta}=.420{\sim}.832$) had slightly more power in predicting trunk control than the $FM-U{\cdot}L/E$. TIS-dynamic sitting balance, TUG and the MBI-mobility part. This study 치early indicates that trunk control is still impaired in stroke patients. Measures of trunk control were significantly related with values of balance, gait and functional performance ability. The results imply that management of trunk rehabilitation after stroke should be emphasized.

Feasibility Study of Docetaxel and Cyclophosphamide Six- Cycle Therapy as Adjuvant Chemotherapy for Japanese Human Epidermal Growth Factor Receptor 2-Negative Breast Cancer Patients

  • Abe, Hajime;Mori, Tsuyoshi;Kawai, Yuki;Tomida, Kaori;Kubota, Yoshihiro;Umeda, Tomoko;Tani, Tohru
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.8
    • /
    • pp.4835-4838
    • /
    • 2013
  • Background: We compared treatment completion rates and safety of docetaxel and cyclophosphamide sixcycle therapy (TC6) with docetaxel followed by 5FU, epirubicin and cyclophosphamide (T-FEC) therapy in Japanese patients with human epidermal growth factor receptor 2 (HER2)-negative breast cancer. Materials and Methods: We administered TC6 q3w or T-FEC q3w to HER2-negative breast cancer patients. The primary endpoint of this trial was toxicity. As second endpoints, the treatment completion rate and relative dose intensity were evaluated. Results: The TC6 and T-FEC group consisted of 22 and 21 patients, respectively. Concerning hematological toxicity, grade 3 or higher adverse reactions included neutropenia and febrile neutropenia. As non-hematological adverse events, exanthema and peripheral neuropathy were frequently reported in the TC6 group, whereas more patients of the T-FEC group reported nausea and vomiting. In TC6, the treatment completion rate was 86.4% and the relative dose intensity of docetaxel was 93.2%. In T-FEC, the values were 95.2% and 98.9%, respectively. Conclusions: These results suggest that TC6 is tolerable in Japanese, and that this regimen can also be performed in outpatient clinics. However, with the TC6 regimen, the compliance was slightly lower than with the T-FEC regimen, and supportive therapy needs to be managed appropriately.

Analgesic Effects of Taxus cuspidata Pharmacopuncture Using Different Extraction Methods on the Formalin-Induced Pain Model (추출 방식의 차이에 따른 주목약침이 Formalin 유도 통증 모델의 진통에 미치는 영향)

  • Shin, You Bin;Lee, Hyun Jong;Kim, Jae Soo;Lee, Yun Kyu
    • Journal of Acupuncture Research
    • /
    • v.33 no.3
    • /
    • pp.17-28
    • /
    • 2016
  • Objectives : This study was designed to investigate the analgesic effects of Taxus cuspidata pharmacopuncture(TCP) at KI03 on formalin-induced pain in rats and to evaluate the efficiency of different extraction methods of Taxus cuspidata(TC). Methods : 30 rats were divided into 5 groups, each consisting of 6 rats. Each of the groups was treated two times. The first treatment for its right KI03 was as follows: rats were treated with normal saline(NOR), normal saline(CON), hot-water extraction of TC(W), ethanol extraction of TC(E), and ultrasonification extraction of TC(U). The second treatment was given 35 mins after the first one. Rats in NOR were treated with normal saline at their hind-paw. All groups, except NOR, were treated with formalin(5 %, $40{\mu}{\ell}$) at their hind-paw. To evaluate pain behavior, Ultrasonic vocalization(USV) was examined to be around 18~30 kHz. After analysis of USV, blood samples were taken from the rats for analysis of Substance P, aspartate aminotransferase(AST) and alanine aminotransferase(ALT). Results : In the experimental groups, USV was significantly decreased compared with CON and similar to that of NOR in the early phase. But there were no significant differences among the three extraction methods of TC. In addition, Substance P of W was significantly decreased. AST and ALT activation showed no significant differences among the 5 groups. Conclusion : These results show that regardless of extraction methods of TC, TCP at KI03 has analgesic effects in the early phase on formalin-induced pain in rats. In particular, hot-water extraction of TC significantly reduces Substance P activation.

Standardization of Rare Earth Elements in ISO TC 298 and Korea's Standardization Strategy (ISO TC 298에서의 희토류 분야 표준화 현황과 우리나라의 전략 및 과제)

  • Eom, Nu Si A;Abbas, Sardar Farhat;Aneeq, Haq Muhammad;Zarar, Rasheed Mohammad;Lee, Mi Hye;Kim, Bum Sung;Kim, Taek-Soo;Lee, Bin
    • Journal of Powder Materials
    • /
    • v.26 no.3
    • /
    • pp.251-257
    • /
    • 2019
  • Since the ISO decided to deal with rare-earth elements at the $298^{th}$ Technical Committee (TC) in 2015, Korea has participated in four plenary meetings and proposed four standards as of June 2019. The status of ISO TC 298, the standards covered by the TC, and the standardization strategies of Korea are summarized. Korean delegations are actively engaged in WG2, which deals with recycling, proposing four standards for fostering the rare-earth recycling industry. However, the participation of domestic experts is still low compared with the increase in the number of working groups and the number of standards in TC 298. The aim of this article is to summarize the current status of ISO international standards related to rare-earth elements, to encourage relevant experts to participate in standardization, and to develop international standards that accurately reflect the realities of the industry.

Stable Desalination of Hardness Substances through Charge Control in a Capacitive Deionization System (축전식 탈염 시스템에서 전하량 제어를 통한 경도물질의 안정적인 탈염)

  • Kim, Yoon-Tae;Choi, Jae-Hwan
    • Applied Chemistry for Engineering
    • /
    • v.30 no.4
    • /
    • pp.472-478
    • /
    • 2019
  • A stable desalination method of the hardness substance such as $Ca^{2+}$ by controlling the total charge (TC) supplied to the membrane capacitive deionization (MCDI) cell was studied. The adsorption (1.5 V) and desorption (0.0 V) were repeated 30 times while varying the TC in the adsorption process. The concentration and pH of effluent, adsorption and desorption amounts, current densities and cell potentials were analyzed in the desalination process. The maximum allowable charge (MAC) of the carbon electrode used in MCDI cell was measured to be 46 C/g. As a result of operation at TC (40 C/g) below the MAC value, electrode reactions did not occur, resulted in the stable desalination characteristics for a long-term operation. When operating at TCs (50, 60 C/g) above the MAC value, however, the concentration and pH of effluent varied greatly. Also, the scale was formed on the electrode surface due to electrode reactions, and the electric resistance of the cell gradually increased. It was thus concluded that it is possible to remove stably the hardness substance without any electrode reactions by controlling the charge supplied to MCDI cell during the adsorption process.

Effect of Hematological Factors on the Risk Index of Cardiovascular Disease (혈액학적 인자가 심혈관 질환 위험지수에 미치는 영향)

  • Hyun An;Hyun-Seo Yoon;Chung-Mu Park
    • Journal of radiological science and technology
    • /
    • v.46 no.4
    • /
    • pp.303-313
    • /
    • 2023
  • This study aimed to investigate the relevance of cardiovascular disease risk factors AI and AIP, divided into three groups, among 300 individuals who underwent health checkups at the hospital. Various variables such as Age, Sex, BMI, WC, TC, TG, HDL-C, LDL-C, FBS, HbA1C, SBP, DBP, HR, AI (TC/HDL-C), and AIP (log(TG/HDL-C)) were analyzed using statistical methods including frequency analysis, cross-tabulation, one-way ANOVA, Pearson's correlation analysis, and multiple linear regression analysis. The cross-analysis based on cardiovascular disease risk criteria revealed that men and individuals in their 50s had higher cardiovascular disease risk based on AI and AIP. Significant differences were observed in TG, TC, HDL-C, LDL-C, SBP, DBP, AI (TC/HDL-C), and AIP (log(TG/HDL-C)) according to AI criteria. For the AIP criteria, TG, TC, HDL-C, FBS, HbA1C, HR, AI (TC/HDL-C), and AIP (log(TG/HDL-C)) were identified as cardiovascular disease risk factors. FBS and HbA1c showed the highest positive correlation In the correlation analysis, followed by TC and LDL-C. The lowest positive correlation was observed between LDL-C and DBP. In terms of negative correlation, HDL-C and AI had the highest negative correlation, while LDL-C and TG showed the lowest negative correlation. Multiple regression analysis indicated that the AI and AIP risk criteria had explanatory powers of 73.6% and 72.5%, respectively. HDL-C had the greatest negative effect on the AI risk criterion, while TG had the most significant influence on the AIP risk criterion. In conclusion, while other serological variables are important, managing HDL-C and TG levels may help reduce the risk of cardiovascular disease.

Adsorption and electro-Fenton processes over FeZSM-5 nano-zeolite for tetracycline removal from wastewater

  • Niaei, Hadi Adel;Rostamizadeh, Mohammad
    • Advances in nano research
    • /
    • v.9 no.3
    • /
    • pp.173-181
    • /
    • 2020
  • Adsorption and heterogeneous electro-Fenton process using iron-loaded ZSM-5 nano-zeolite were investigated for the removal of Tetracycline (TC) from wastewater. The nano-zeolite was synthesized hydrothermally and modified through impregnation. The zeolite was characterized by XRD, FT-IR, FE-SEM, N2 adsorption-desorption, and NH3-TPD techniques. The equilibrium data were best represented by the Freundlich isotherm. The pseudo-second-order kinetic model was the most accurate model for the adsorption of TC on the modified nano-zeolite. The effect of parameters such as pH of solution and current density were investigated for the heterogeneous electro-Fenton process. The results showed that the current density of 150 mA and pH of 3 led to the highest TC removal (90.35%) at 50 min. The nano-zeolite showed the appropriate reusability. Furthermore, the developed kinetic model was in good agreement with the removal data of TC through the electro-Fenton process.

High-Tc superconducting magnet properites with design conditions (설계조건에 따른 고온 초전도 마그넷의 특성변화)

  • Kim, Min-Ki;Ko, Yo;Han, Byoung-Sung
    • Electrical & Electronic Materials
    • /
    • v.8 no.4
    • /
    • pp.451-457
    • /
    • 1995
  • Most important study on development of high-Tc superconducting magnet is magnetic properties with design conditions To study optimal design condition of high-Tc superconducting magnet, small size solenoid magnet was designed and simulated. Design conditions are radius of bobbin, radius of magnet, length of magnet, critical cur-rent and notch size. We know that intensity of magnetic fields was controled by critical current and uniformity of magnetic fields was controled by notch size. The optimal design conditions to get the high intensity and uniformity of magnetic field in this experiments were radius of bobbin=3[cm], radius of magnetic=12[cm], length of Z=10[cm], notch size=6[cm] and critical current=12[A].

  • PDF

A Study of Bone Scan Time by Use of $^{99m}Tc-MDP$ ($^{99m}Tc-MDP$를 이용한 Bone scan 시간(時間)에 관(關)한 고찰(考察))

  • Park, Soung-Ock;Lee, Hyun-Bae
    • Journal of radiological science and technology
    • /
    • v.17 no.1
    • /
    • pp.77-86
    • /
    • 1994
  • The bone scan reflects the metabolic reaction of bone to a disease process, whether neoplastic, traumatic or inflammatory. In normal bone tissue, the labeled diphosphate complexes accumulate in the perivascular fluid next to the marrow cavity at the interface between uncalcified and calcified bone matrix. HMDP has the most rapid plasma clearance among the commonly used diphosphonate followed by MDP and then HEDP. I have studied about bone scan time by use of $^{99m}Tc-MDP$, and got 336 images from 112 patients. The result obtained as follow; 1. Accumulation rate of $^{99m}Tc-MDP$ is higher than other age groups in below 30-year old group. 2. Accumulation rate, in 10year old group, is 75.85% on 120min. but other groups are most high on 180 min. 3. The density differants between bone and soft tissue increased with time. 4. Image contrast is good in younger group than old.

  • PDF

The Irrigation Characteristics of The Eumsung TM/TC system (음성지구 물관리자동화시스템의 용수공급 특성)

  • Ko, Gwang-Don;Kwun, Soon-Kuk
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.1-6
    • /
    • 2005
  • Eumsung TM/TC system is composed of one control center, four reservoirs and twenty irrigation canal systems. In this paper we analyzed operation frequencies of the irrigation system to verify the effect of TM/TC system. Large facilities's operation frequency were more low then small thing and irrigation type was continuous irrigation. operation frequency was most high in may and june. usually water gate was operated once per 5-10 day. With these analysis we concluded that operators should operate irrigation facilities based on scientific technique and designer should make a proper choice in TM/TC system selection fit to the field.

  • PDF