• Title/Summary/Keyword: T wave amplitude

Search Result 93, Processing Time 0.025 seconds

Effect of Exercise and Physical Stresses on the Electrocardiogram (운동부하 및 각종 신체조건이 혈압 및 ECG에 미치는 영향 -제2보- (각종 Stress에 의한 심전도 변화))

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.16 no.2
    • /
    • pp.129-136
    • /
    • 1982
  • We studied this experiment to compare the effects of exercise and other body conditions: i.e., Flack test, cold pressor test and bicycle ergometry on the electrocardiogram. We had sixty healthy college students who were thirty nine men and twenty one women. Their $mean{\pm}SD$ values of physical characteristics were as follows: age; $22.0{\pm}1.4$, weight; men $61.7{\pm}5.6\;kg$, women $46.2{\pm}7.47\;kg$. We observed the changes of P-Q and Q-T interval, R and T amplitude, mean QRS vector, S-T segment deviation, and P and T vector. The result obtained were summarized as follows: P vector was shifted rightward regardless of the type of stress. T vector was shifted var-in each stress but in the bicycle ergometry T vector was shifted leftward. Mean QRS vector was shifted rightward immediately after the bicycle ergometry. Percentage of the occurrence of the depression of S-T segment was 21.7% at the immediately after the submaximal bicycle ergometry in lead II. The elevation of S-T segment was often observed after the mild stresses. Increased amplitude of T wave in the cold pressor test and decreased amplitude of T wave in the bicycle ergometry were observed. In the bicycle ergometry and other stresses, the precise mechanism of S-T segment changes was unexplained but insufficient repolarization in base or apex of the left ventricle due to heart strain was indicated by so called S-T vector analysis.

  • PDF

Studies on the Electrocadiogram in Non-human Primates Reared in Korea (國內 飼育 원숭이의 心電圖에 관한 硏究)

  • 서진석;서지민;이버들;송근호;이수진;김덕환;현병화;신남식
    • Journal of Veterinary Clinics
    • /
    • v.19 no.2
    • /
    • pp.132-138
    • /
    • 2002
  • Non-human primates are widely used for experimental animal and raised as companion animal in Korea. To establish the electrocadiogram (ECG) of non-human primates that are domestically raised, the author measured bipolar limb leads and augmented unipolar limb leads, after tiletamine/zolazepam (TZ) injection as sedative agents. The amplitudes of P,Q, R,S and T wave and duration time of P wave, QRS complex, PR and QT interval in each lead of ECG were evaluated in 7 non-human primates at 15 minutes after TZ injection, respectively. The amplitude of P wave in I, II,III, aVR, aVL and aVF leads revealed 0.06$\pm$ 0.05,0.14$\pm$ 0.05, 0.1 $\pm$ 0.05,-0.11 $\pm$ 0.06,-0.04$\pm$ 0.04 and 0.12$\pm$ 0.05 mV respectively. The amplitude of Q wave revealed -0.16$\pm$ 0.15, -0.23$\pm$ 0.18, -0.17$\pm$ 0.13, 0.16$\pm$0.13, 0.04$\pm$ 0.09 and -0.2$\pm$0.13 mV, respectively. The amplitude of R wave revealed 0.56$\pm$0.56, 1.24$\pm$ 0.67, 0.92$\pm$0.33, -0.37$\pm$ 1.14, -0.22$\pm$ 0.47 and 1.12 $\pm$ 0.47 mV, respectively. The amplitude of S wave revealed -0.02$\pm$ 0.08, -0.04$\pm$0.06, -0.06$\pm$0.04, 0.02$\pm$0.04, 0.04$\pm$0.09 and -0.04 $\pm$ 0.06 mV, respectively. The amplitude of T wave revealed -0.01 $\pm$ 0.15,-0.02$\pm$ 0.13, 0.01 $\pm$ 0.08, 0.02$\pm$ 0.12, 0.01 $\pm$ 0.11 and -0.03$\pm$ 0.09 mV, respectively. The duration time of P wave revealed 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.02, 0.05 $\pm$ 0.02, 0.04$\pm$ 0.01 and 0.04$\pm$ 0.01 sec, respectively. The duration time of QRS complex revealed 0.05 $\pm$ 0.02,0.05$\pm$ 0.01, 0.05 $\pm$ 0.01, 0.04$\pm$ 0.01, 0.05$\pm$ 0.01 and 0.05 $\pm$ 0.01 sec, respectively. The duration time of PR interval revealed 0.08$\pm$ 0.01, 0.07$\pm$0.01,0.08$\pm$ 0.03, 0.08$\pm$0.01, 0.08$\pm$ 0.01 and 0.08$\pm$0.01 sec, respectively. The duration time of QT interval revealed 0.23$\pm$ 0.06, 0.22$\pm$ 0.05, 0.23 $\pm$ 0.06, 0.23$\pm$ 0.06, 0.24$\pm$ 0.05 and 0.22$\pm$ 0.02 sec, respectively. No significant changes were observed in e amplitude of P and T waves. The amplitude of QRS complex in ketamine group was higher than that of TZ group. However, no significant changes were observed in both intra-group and inter-group. There were no significant changes in the duration time of P wave, QRS complex and PR interval obtained from both groups. Also, the duration time of QT interval in TZ group was significantly longer at 30 min.(P< 0.05) an that of 10 minutes after injection. However, significant difference was not found between two groups. The mean cardiac electric axis in ketamine group tended to decrease until 30 min. after injection and then gradually increase. However, mean cardiac electric axis of TZ group was increased until 30 min. after injection and then decreased. But significant differences were not observed between groups. These results suggest that the ECG pattern after TZ injection to non-human primates reared in korea was established. It was also considered that the injection of ketamine and TZ didn't significantly affect on ECG pattern of the non-human primates.

Ultrasonic Measurement of Interfacial Layer Thickness of Sub-Quarter-Wavelength

  • Kim, No-Hyu;Lee, Sang-Soon
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.6
    • /
    • pp.577-582
    • /
    • 2003
  • This paper describes a new technique for thickness measurement of a very thin layer less than one-quarter of the wavelength of ultrasonic wave used in the ultrasonic pulse-echo measurements. The technique determines the thickness of a thin layer in a tapered medium from constructive interference of multiple reflection waves. The interference characteristics are derived and investigated in theoretical and experimental approaches. Modified total reflection wave g(t) defined as difference between total and first reflection waves increases in amplitude as the interfacial layer thickness decreases down to zero. A layer thickness less than one-tenth of the ultrasonic wavelength is measured using the maximum amplitude of g(t) with a good accuracy and sensitivity. The method also requires no inversion process to extract the thickness information from the waveforms of reflected waves, so that it makes possible to have the on-line thickness measurement of a thin layer such as a lubricating oil film in thrust bearings and journal bearings during manufacturing process.

Effect of Hematocrit Level on the Radial Pulse Wave (적혈구 용적이 요골 동맥의 맥파에 미치는 영향)

  • Ryu, Hyun-Hee;Jeon, Young-Ju;Kim, Jae-Uk;Lee, Hae-Jung;Woo, Young-Jae;Lee, Yu-Jung;Kim, Jong-Yeol
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.5
    • /
    • pp.1035-1040
    • /
    • 2009
  • In this work, we investigate the effect of blood hematocrit level on the radial pulse wave to study the clinical application of the pulse analyzer. For this purpose, we measured the radial pulse wave at the left Gwan for 15 males with abnormal high hematocrit level and 47 males with normal hematocrit level at the age of thirties and forties. Various variables of the radial pulse wave between two groups were analyzed by Student's T test. We found significant differences in several characteristic variables in the amplitude, time-span and the integrated area of the amplitude and time of the pulse wave. The systolic peak in the amplitude of the radial pulse wave was higher in abnormal high hematocrit group. In contrast, the third peak from the second incisure was higher and longer in normal hematocrit group. Our study suggests that the radial pulse wave can be useful in distinguishing the patient group with high hematocrit level and thus with high blood viscosity. Our finding may motivate research activities towards diverse clinical applications of the pulse wave.

Electrocardiograms in the Rats Fed Diets with Boiled Eggs (삶은 계란을 섭취한 흰쥐의 심전도)

  • 박병성
    • Food Science of Animal Resources
    • /
    • v.21 no.3
    • /
    • pp.272-277
    • /
    • 2001
  • Electrocardiograms in rats fed diets with boiled eggs for 30 days was investigated. Amplitudes of P,Q and R waves were not significant differences among treatment groups. Amplitude of S wave in rats fed the diet with 95% boiled eggs was significantly tended to be increased compared with other groups(P<0.05). Amplitude of T wave in the rats fed the diet with 0% boiled eggs showed the highest values, and there were significant difference among treatment groups fed diets with 0% boiled eggs, 25% and 95% boiled eggs (P<0.05). Durations of P and PQ(PR) waves were high in the rats fed diets with 25% and 50% boiled eggs (P<0.05). Duration of QRS complex showed low in the rats fed diet 0% boiled eggs but not significant difference among treatment groups. Duration of QT was high in the rats fed diet with 0% boiled eggs(P<0.05). This result is assumed that electrocardiograms in the rats is not changed to intake the boiled eggs.

  • PDF

PVC Classification based on QRS Pattern using QS Interval and R Wave Amplitude (QRS 패턴에 의한 QS 간격과 R파의 진폭을 이용한 조기심실수축 분류)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.4
    • /
    • pp.825-832
    • /
    • 2014
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require accurate detection of P-QRS-T point, higher computational cost and larger processing time. Even if some methods have the advantage in low complexity, but they generally suffer form low sensitivity. Also, it is difficult to detect PVC accurately because of the various QRS pattern by person's individual difference. Therefore it is necessary to design an efficient algorithm that classifies PVC based on QRS pattern in realtime and decreases computational cost by extracting minimal feature. In this paper, we propose PVC classification based on QRS pattern using QS interval and R wave amplitude. For this purpose, we detected R wave, RR interval, QRS pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through QS interval and R wave amplitude. The performance of R wave detection, PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30 PVC. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 93.72% in PVC classification.

Three-Dimensional Magnetohydrodynamic Simulations of Nonlinear Field Line Resonances

  • Kim, Kyung-Im;Lee, Dong-Hun;Ryu, Dong-Su
    • Bulletin of the Korean Space Science Society
    • /
    • 2010.04a
    • /
    • pp.39.2-39.2
    • /
    • 2010
  • Field line resonances (FLRs) observed in the magnetosphere often have the amplitude of a few nT, which indicates that dB/B roughly satisfies ~0.01. It is well known that the FLRs are excited by compressional waves via mode conversion, but there has been no apparent criterion on the maximum amplitude in the regime of linear approximations. Such limited range of amplitude should be understood by including nonlinear saturation of FLRs, which has not been examined until now. In this study, using a three-dimensional magnetohydrodynamic (MHD) simulation code, we examine the evolution of nonlinear field line resonances (FLRs) in the cold plasmas. The MHD code used in this study allows a full nonlinear description and enables us to study the maximum amplitude of FLRs. When the disturbance is sufficiently small, it is shown that linear properties of MHD wave coupling are well reproduced. In order to examine a nonlinear excitation of FLRs, it is shown how these FLRs become saturated as the initial magnitude of disturbances is assumed to increase. Our results suggest that the maximum amplitude of FLRs become saturated at the level of the same order of dB/B as in observations. In addition, we discuss the role of both linear terms and nonlinear terms in the MHD wave equations.

  • PDF

Method Generating Circular Wave for Synthetic Focusing (초음파 영상 시스템의 Synthetic Focusing을 위한 구면파 발생 방법)

  • Oh, J.S.;Kim, J.J.;Song, T.K.;Ahn, Y.B.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.215-216
    • /
    • 1998
  • The ultrasonic imaging systems using synthetic aperture beamforming has been formed in the way that one element transmits and then receives a pulse. Because the amplitude of a pulse from one element is too small to propagate a long distance, the SNR(Signal to Noise Ratio)is low. This paper proposes the method to make a circular wave almost equal to one generated by one element using several elements. The amplitude of the wave made up of several elements is much larger than that of one element. And we can improve the SNR.

  • PDF

Change of arterial pulse wave characteristic by measurement posture and brachial blood pressure (측정 자세 및 상완 혈압에 의한 맥파 특성 변화)

  • Nam, Ki-Chang;Kim, Eun-Gun;Hoe, Hyun;Huh, Young
    • Science of Emotion and Sensibility
    • /
    • v.12 no.3
    • /
    • pp.299-306
    • /
    • 2009
  • In this study, pulse waves were measured at radial artery using non-invasive tonometric pulse pressure measurement system, SphygmoCor(AtCor, Australia), according to subject's posture. Then it was analysed whether the pulse wave parameters, which contain heart activities, change among three different postures (upright stand, sit, and supine). And it was also verified that the pulse wave parameters change among blood pressure level groups(hypotensive, normotensive, and hypertensive). As a results, posture effects were verified in time information of pulse wave rather than amplitude. But some parameters calculated by ratio of two amplitude, such as augmented index(AI) and ratio of central aortic pulse and radial artery pulse, showed significant difference according to postures. In post hoc test, time to the $1^{st}$ and $2^{nd}$ pulse peak(P_$T_1$, and P_$T_2$), ED(ejection duration), and HR(heart rate) showed significant difference among posture groups with each other. In comparison of blood pressure groups, it was verified that the parameters related to amplitude of pulse wave showed significant difference rather than time information.

  • PDF

Effects of Sodium Bicarbonate on Electrocardiogram in Hyperkalemia (과칼륨혈증의 심전도변화와 중조(重曹)투여가 이에 미치는 영향)

  • Cho, Young-Ho;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.16 no.1
    • /
    • pp.41-50
    • /
    • 1982
  • The effects of $NaHCO_3$ on the electrocardiogram of rats were studied in the induced hyperkalemia. The subjects were divided into 4 groups: the group 1 was normal control and the data on this normal control had teen obtained from the following three groups before administration of KCl or $NaHCO_3$, the group 2 (KCl) was administered 40 ml per kg body weight of the 10 per cent KCl solution, the group 3 $(NaHCO_3)$ was administered 40 ml per kg body weight of the 10 per cent $NaHCO_3$ solution, and the group 4 $(KCl+NaHCO_3)$ was received 10 per cent KCl, which was followed by administration of 10 per cent $NaHCO_3$ at one and half hours later. In KCl, the heart rate was decreased rapidly, and then maintained its level, later rapid decreasing heart rate was followed by the cardiac stand still. The mean electrical axis of QRS complex became progressively deviated to the left. The amplitude of T wave was increased transiently but was not changed thereafter. There was prolongation of the P-Q interval and the Q-T interval at the beginning and then they were shortened. In $NaHCO_3$, the heart rate was decreased rapidly at the beginning, later showed a tendency of recovery. The mean electrical axis of QRS was not changed initially, but later became deviated to the left. The amplitude of T wave was not changed. There was prolongation of the P-Q interval and the Q-T interval at the beginning and then they were shortened. In $KCl+NaHCO_3$, there were a tendency of recovery of both the amplitude of the T wave and the electrical axis of the QRS complex after administration of $NaHCO_3$ but the heart rate was not recovered. There was prolonged P-Q interval, but the Q-T interval was relatively unchanged.

  • PDF