• 제목/요약/키워드: T wave

검색결과 1,256건 처리시간 0.028초

A Study on the Allowable Bearing Capacity of Pile by Driving Formulas (각종 항타공식에 의한 말뚝의 허용지지력 연구)

  • Lee, Jean-Soo;Chang, Yong-Chai;Kim, Yong-Keol
    • Journal of Navigation and Port Research
    • /
    • 제26권1호
    • /
    • pp.106-111
    • /
    • 2002
  • The estimation of pile bearing capacity is important since the design details are determined from the result. There are numerous ways of determining the pile design load, but only few of them are chosen in the actual design. According to the recent investigation in Korea, the formulas proposed by Meyerhof based on the SPT N values are most frequently chosen in the design stage. In the study, various static and dynamic formulas have been used in predicting the allowable bearing capacity of a pile. Further, the reliability of these formulas has been verified by comparing the perdicted values with the static and dynamic load test measurements. Also, in most cases, these methods of pile bearing capacity determination do not take the time effect consideration, the actual allowable load as determined from pile load test indicates severe deviation from the design value. The principle results of this study are summarized as follows : As a result of estimate the reliability in criterion of the Davisson method, t was showed that Terzaghi & Peck >Chin>Meyerhof > Modified Meyerhof method was the most reliable method for the prediction of bearing capacity. Comparisons of the various pile-driving formulas showed that Modified Engineering News was the most reliable method. However, a significant error happened between dynamic bearing capacity equation was judged that uncertainty of hammer efficiency, characteristics of variable, time effect etc... was not considered. As a result of considering time effect increased skin friction capacity higher than end bearing capacity. It was found out that it would be possible to increase the skin friction capacity 1.99 times higher than a driving. As a result of considering 7 day's time effect, it was obtained that Engineering news, Modified Engineering News, Hiley, Danish, Gates, CAPWAP(CAse Pile Wave Analysis Program) analysis for relation, repectively, $Q_{u(Restrike)} / Q_{u(EOID)} = 0.98t_{0.1}$ , $0.98t_{0.1}$, $1.17t_{0.1}$, $0.88t_{0.1}$, $0.89t_{0.1}$, $0.97t_{0.1}$.

Comparison of apical sealing ability of continuous wave of obturation technique using EndoTwinn and System B (EndoTwinn과 System B continuous wave of obturation units를 이용한 근단부 근관충전 효율비교)

  • Shin, Hyun-Ju;Park, Jeong-Kil;Hur, Bock;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제32권6호
    • /
    • pp.522-529
    • /
    • 2007
  • The purpose of this study was to compare the apical leakage of the root canal filled with the System B and the EndoTwinn(the combined application of heat and ultrasonic vibration). Sixty extracted premolars with straight root were cleaned and shaped to size 35. Group SB was obturated using System B and Group ET was filled with EndoTwinn. A size 35 of 0.06 tapered gutta-percha and Adseal were used and the plugger which could be introduced to 4 mm short of working length was selected in the obturation procedure. As the positive control, Group PC was not filled. In Group SB, ET and PC, all external surfaces of each tooth were coated with nail varnish leaving only 1 mm area around the apical foramen. In the negative control of Group NSB and Group NET, all of external tooth surface including apical foramen was coated with the nail varnish. The specimens were immersed in methylene blue dye solution for 2 days. Then the specimens were sectioned at each 1 mm from apex to 5 mm level. The final score of one specimen was given by summing up of the points at all levels. The dye leakage of Group ET was significantly less than that observed in Group SB (p < 0.05). And the frequency of gutta-percha pulling out from root canal when the plugger was removed was more often with the System B than with EndoTwinn but there was no significant difference.

Exploiting W. Ellison model for seawater communication at gigahertz frequencies based on world ocean atlas data

  • Tahir, Muhammad;Ali, Iftikhar;Yan, Piao;Jafri, Mohsin Raza;Jiang, Zexin;Di, Xiaoqiang
    • ETRI Journal
    • /
    • 제42권4호
    • /
    • pp.575-584
    • /
    • 2020
  • Electromagnetic (EM) waves used to send signals under seawater are normally restricted to low frequencies (f) because of sudden exponential increases of attenuation (𝛼) at higher f. The mathematics of EM wave propagation in seawater demonstrate dependence on relative permeability (𝜇r), relative permittivity (𝜀r), conductivity (𝜎), and f of transmission. Estimation of 𝜀r and 𝜎 based on the W. Ellison interpolation model was performed for averaged real-time data of temperature (T) and salinity (S) from 1955 to 2012 for all oceans with 41 088 latitude/longitude points and 101 depth points up to 5500 m. Estimation of parameters such as real and imaginary parts of 𝜀r, 𝜀r', 𝜀r", 𝜎, loss tangent (tan 𝛿), propagation velocity (Vp), phase constant (𝛽), and α contributes to absorption loss (La) for seawater channels carried out by using normal distribution fit in the 3 GHz-40 GHz f range. We also estimated total path loss (LPL) in seawater for given transmission power Pt and antenna (dipole) gain. MATLAB is the simulation tool used for analysis.

Enhancing the Reliability of Coating Flaw Detection for Pipes Buried in Soil Using a Multi-Electrode Detector (다전극 탐상을 통한 토중 매설배관 피복결함 탐상 정확도의 개선)

  • Kim, M.G.;Lim, B.T.;Kim, K.T.;Chang, H.Y.;Park, H.B.;Kim, Y.S.
    • Corrosion Science and Technology
    • /
    • 제19권5호
    • /
    • pp.265-280
    • /
    • 2020
  • External corrosion of buried pipes can be controlled using both coating and cathodic protection. However, deterioration of the coating can occur due to several reasons. The detection reliabilty of coating flaw detection methods is affected by interference such as metal objects connected to rectifiers and copper grids. When performing parallel direct current voltage gradient (DCVG) inspection, a sine wave form without potential reversal in voltage gradient appears in the area where the interference exists. However, this area may be not identified using existing methods. The objective of this study was to determine the effect of analyzing direction on the reliability of coating flaw detection of pipes buried in soil using a multi-electrode detector. DCVG on the buried pipe was measured along the buried pipe. This measurement parallel to the pipe was repeated. Measured data were analyzed for parallel, vertical, and diagonal directions. The reliability of coating flaw detection was improved by up to 46.4% compared to the conventional method.

Studies on IF noise caused by transmitter signal leakages of the W-band homodyne FMCW radar with a single antenna configuration (단일 안테나를 사용하는 W-대역 호모다인 FMCW 레이더의 누설신호에 의한 IF 잡음에 관한 연구)

  • Park Jung-Dong;Kim Wan-Joo
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제42권7호
    • /
    • pp.49-56
    • /
    • 2005
  • In this paper, we describe a solution to improve the effects of the transmitter leakage signals on the frequency modulated continuous wave (FMCW) radar with a single antenna configuration. We analyze characteristics of the IF noise caused by insufficient isolation between transmitter and receiver. The magnitude of the intermediate frequency (IF) noise from a front-end can be reduced by matching the LO signal delay time with that of the largest leakage source. Because the IF noise has periodic singularities at nT$_{m}$/2, t=0,1,2$\cdots$, we find that spectrum of the IF noise due to the leakage signals is very similar to that of the VCO moduation signal except low frequency elements in the vicinity of DC. Based on the studies, we fabricated a W-band homodyne FMCW radar sensor and verified the proposed solution. The results are applicable to design of the homodyne FMCW radar with a single antenna configuration.

Design and Fabrication of 100 GHz MIMIC Amplifier Using Metamorphic HEMT (Metamorphic HEMT를 이용한 100GHz MIMIC 증폭기의 설계 및 제작)

  • 안단;이복형;임병옥;이문교;백용현;채연식;박형무;이진구
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • 제41권9호
    • /
    • pp.25-30
    • /
    • 2004
  • In this Paper, the 0.1 w InGaAs/InAlAs/GaAs Metamorphic HEMT, which is applicable to MIMIC, and a 100 GHz MIMIC amplifier were designed and fabricated. The DC characteristics of MHEMT are 640 mA/mm of drain current density, 653 mS/mm of maximum transconductance. The current gain cut-off frequency(fT) is 173 GHz and the maximum oscillation frequency(fmax) is 271 GHz. A 100 GHz amplifier was designed using 0.1${\mu}{\textrm}{m}$ MHEMT and CPW technology. The measured results from the 100 GHz MIMIC amplifiers show good S21 gain of 10.1 dB and 12.74 dB at 100 GHz and 97.8 GHz, respectively.

The effects of Pulsed Ultrasound on the bone healing process in Fracture Model of Diabetes Mellitus Rat (당뇨병증 골절렛트의 골치유 과정에서 맥동성 초음파가 미치는 영향)

  • Min, Soon-Gyu;Chun, Jin-Sung;Yong, Jun-Hwan;Yoo, Young-Dae
    • The Journal of Korean Physical Therapy
    • /
    • 제18권2호
    • /
    • pp.47-58
    • /
    • 2006
  • Purpose: The study to pulsed ultrasound effects of diabetes mellitus fracture model in rat. Methods: We used 36 Sprague-Dawely rats which were divided into 3 groups; the animals were divided into group of 4 rats each 4th, 14th and 28th days. All animal was induced diabetes mellitus model to used streptozotocin with 45 mg/kg. Pulsed wave were divided into $50\;mW/cm^2$ and $100\;mW/cm^2$. Results: T-ALP value was significantly change from group II, III on 14th, 28th days (p<0.05). Especially T-ALP value to between groups was significantly change from group II on 14th days (p<0.05). Osteocalcin value was significantly change from group II on 28th days(p<0.05). At fracture site, osteoblast, osteoclast expression was observed from 4th days after treatment and it reached its maximum intensity at 28th days. At fracture site, $TGF-{\beta}_1$ expression was observed from 4th days after treatment and it reached maximum intensity at 14th days. Conclusion: According to this study, diabetes mellitus fracture model to the more effective is divided into $50m\;W/cm^2$ pulsed ultrasound.

  • PDF

Analysis on The Reflection Degree of Worker's Stress by Brain-waves based Anti-Stress Quotient (뇌파기반 항스트레스 지수에 의한 직장인의 스트레스 반영도 분석)

  • Ahn, Min-Hee
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제11권10호
    • /
    • pp.3833-3838
    • /
    • 2010
  • Brainwave can be the most effective means of detecting the state of the brain that changes moment by moment. Since brain has closed relations with hormones which are a foundation of metabolism, it needs to examine closely the mutual relationship between brainwave and hormone. We examined the possibility to find out such information about metabolism by comparing brainwave with cortisol hormone. The major variables are anti-stress quotient of brainwave and cortisol density which give stress information of the working women, to measure from March 3 to May 28, 2007. To find out the relationship between them, we performed such statistical analysis about the before and after of brainwave training as t-test, correlational analysis and regression analysis. We obtained following results: First, considerable changes of variables is shown by brain-wave training. Second, there exist a correlation between variables. Third, according to regression analysis, influence between variables is verified. Thus, we found that stress information of hormone analytical level can be obtined only through brainwave analysis.

Time-Multiplexed RF Transmission to Improve $B_1$ Homogeneity in High Field MRI

  • Han, Byung-Hee;Seo, Jeung-Hun;Heo, Hye-Young;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • 제29권2호
    • /
    • pp.99-106
    • /
    • 2008
  • To improve $B_1$ homogeneity in high field MRI, the RF power is applied to the transmit array coil elements sequentially in the time-multiplexed way. Since only a single coil element is activated in a time-multiplexing slot, the global standing wave formation in the human body is greatly suppressed. The time-multiplexing slot width is on the order of micro seconds, hence, high-order-harmonic slices can be placed far from the transmit coil and simultaneous multiple slice selection can be avoided. The $B_1$ homogeneities of a birdcage coil and an eight-channel transmit array coil have been compared through finite difference time domain simulations. The simulation results indicate that the proposed technique can reduce the peak-to-peak $B_1$ inhomogeneity down to one fourth of the transmission with a birdcage coil on the central plane of the human head model at 3 T. The mimicking experiments at 3 T, eight separate experiments with a single coil element activated and image reconstruction by combining the eight images, also show promising results. It is expected that the proposed technique has some advantages over other $B_1$ improving methods in real practice since simple RF switching circuitries are only necessary and electromagnetic coupling between the coil elements is out of concern in its realization.

A Computational Model of the Temperature-dependent Changes in Firing Patterns in Aplysia Neurons

  • Hyun, Nam-Gyu;Hyun, Kwang-Ho;Hyun, Kwang-Beom;Han, Jin-Hee;Lee, Kyung-Min;Kaang, Bong-Kiun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제15권6호
    • /
    • pp.371-382
    • /
    • 2011
  • We performed experiments using Aplysia neurons to identify the mechanism underlying the changes in the firing patterns in response to temperature changes. When the temperature was gradually increased from $11^{\circ}C$ to $31^{\circ}C$ the firing patterns changed sequentially from the silent state to beating, doublets, beating-chaos, bursting-chaos, square-wave bursting, and bursting-oscillation patterns. When the temperature was decreased over the same temperature range, these sequential changes in the firing patterns reappeared in reverse order. To simulate this entire range of spiking patterns we modified nonlinear differential equations that Chay and Lee made using temperature-dependent scaling factors. To refine the equations, we also analyzed the spike pattern changes in the presence of potassium channel blockers. Based on the solutions of these equations and potassium channel blocker experiments, we found that, as temperature increases, the maximum value of the potassium channel relaxation time constant, ${\tau}_n(t)$ increases, but the maximum value of the probabilities of openings for activation of the potassium channels, n(t) decreases. Accordingly, the voltage-dependent potassium current is likely to play a leading role in the temperature-dependent changes in the firing patterns in Aplysia neurons.