• Title/Summary/Keyword: T wave

Search Result 1,258, Processing Time 0.033 seconds

High LO-RF Isolation 94 GHz MMIC Single-balanced Mixer (높은 LO-RF 격리 특성의 94 GHz MMIC Single-balanced Mixer)

  • An, Dan;Lee, Bok-Hyung;Lim, Byeong-Ok;Kim, Sung-Chan;Lee, Sang-Jin;Lee, Mun-Kyo;Shin, Dong-Hoon;Park, Hyung-Moo;Park, Hyun-Chang;Kim, Sam-Dong;Rhee, Jin-Koo
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.765-768
    • /
    • 2005
  • In this paper, high LO-RF isolation 94 GHz MMIC single-balanced mixer was designed and fabricated using a branch line coupler and a ${\lambda}/4$ transmission line. The 94 GHz MMIC single-balanced mixer was designed using the 0.1 ${\mu}m$ InGaAs/InAlAs/GaAs Metamorphic HEMT(MHEMT) diode. The fabricated MHEMT was obtained the cut-off frequency($f_T$) of 189 GHz and the maximum oscillation frequency($f_{max}$) of 334 GHz. The designed MMIC single-balanced mixer was fabricated using 0.1 ${\mu}m$ MHEMT MMIC process. From the measurement, the conversion loss of the single-balanced mixer was 23.1 dB at an LO power of 10 dBm. The LO-RF isolations of single-balanced mixer was obtained 45.5 dB at 94.19 GHz. We obtained in this study a higher LO-RF isolation compared to some other balanced mixers in millimeter-wave frequencies.

  • PDF

The Oriental Medical Study about the Arrythmia Detected on the Radial Pulses and the Result of ECG. (촌관척(寸關尺)부의 검측한 부정맥과 Electrocardiographic 결과의 한의학적 검토)

  • Lyu, Heui-Yeong;Heo, Eun-Jung;Kim, Ji-Hyon;Yoon, Jung-Mi;Jeon, Seong-Ha
    • Journal of Oriental Neuropsychiatry
    • /
    • v.19 no.2
    • /
    • pp.165-193
    • /
    • 2008
  • Objective: The ECG which used for this paper, is analysis result from alogrisms of arrythmia, and we have studied that how we could certain Cold(寒)type or Heat(熱) type and that Deficiency(虛) type or Excess(實)type of organs from various special diseases, and we obtained like these results. Method & Conclusion: 1. we depend on our examination about Pulse(脈) because we can't discriminate arrythmia using ECG analysis instruments. 2. We obtained that Cold(寒) type diseases had wave that prolonged above normal baseline and ST wave which had downward aptitude. 3. We obtained that Heat(熱) type diseases had the fibrillation which had shortend wave that compare to normal and had downward aptitude or negative aptitude. 4. We obtained that Respiratory system (肺) diseases had wave that is within normal or is short of normal range and had much fluctuation in potential difference or trans on P wave. 5. The character of EKG which presented about diseases of gastric systems is prolonged above narmal range of wave, and the ECG had represented mixed wave with Heat(熱) type when accompany inflammatory in gastric system. 6. The wave of Blood Stasis(瘀血) type had upward aptitude of QRS wave, and the wave of anemia or blood loss type(少血) had downward aptitude of QRS wave, the wave which had both Cold(寒)) and Heat (熱) represented mixed waves. 7. The Knotted Pulse(結脈) and Intermittent Pulse(代脈)is corresponded with sinus brady cardia, and the Swift Pulsle(疾脈) is corresponded with fibrillation. 8. We pay attention to the relations of formations about pressures pulse from formations of EMD( electromechanical dissociation ). Result : From these results, we will have to study about ECG which using in tests of change of Parkinsons disease.

  • PDF

Effect of Exercise and Physical Stresses on the Electrocardiogram (운동부하 및 각종 신체조건이 혈압 및 ECG에 미치는 영향 -제2보- (각종 Stress에 의한 심전도 변화))

  • Park, Won-Kyun;Chae, E-Up
    • The Korean Journal of Physiology
    • /
    • v.16 no.2
    • /
    • pp.129-136
    • /
    • 1982
  • We studied this experiment to compare the effects of exercise and other body conditions: i.e., Flack test, cold pressor test and bicycle ergometry on the electrocardiogram. We had sixty healthy college students who were thirty nine men and twenty one women. Their $mean{\pm}SD$ values of physical characteristics were as follows: age; $22.0{\pm}1.4$, weight; men $61.7{\pm}5.6\;kg$, women $46.2{\pm}7.47\;kg$. We observed the changes of P-Q and Q-T interval, R and T amplitude, mean QRS vector, S-T segment deviation, and P and T vector. The result obtained were summarized as follows: P vector was shifted rightward regardless of the type of stress. T vector was shifted var-in each stress but in the bicycle ergometry T vector was shifted leftward. Mean QRS vector was shifted rightward immediately after the bicycle ergometry. Percentage of the occurrence of the depression of S-T segment was 21.7% at the immediately after the submaximal bicycle ergometry in lead II. The elevation of S-T segment was often observed after the mild stresses. Increased amplitude of T wave in the cold pressor test and decreased amplitude of T wave in the bicycle ergometry were observed. In the bicycle ergometry and other stresses, the precise mechanism of S-T segment changes was unexplained but insufficient repolarization in base or apex of the left ventricle due to heart strain was indicated by so called S-T vector analysis.

  • PDF

Characteristics of Pulse Waves in Various Age Categories and Applicability of Pulse Wave to Metabolic Syndrome Using Pen-type Piezoresistive Sensor (펜타입 압저항 센서를 활용한 연령별 맥파 특성 및 맥파의 대사증후군에의 적용 가능성 평가)

  • Ha, Ye-Jin;Cho, Mun-Young;Yun, Jong-Min;Jun, Kyu-Sang;Park, Soo-Jung;Shin, Sun-Ho
    • The Journal of Internal Korean Medicine
    • /
    • v.33 no.3
    • /
    • pp.257-271
    • /
    • 2012
  • Objectives : The purpose of this study was to confirm that the pulse analyzer is useful for analyzing characteristics of variables of pulse waves in age categories, evaluating pulse waves of the metabolic syndrome group, compared with those of the non-metabolic syndrome group in Korean adults. Methods : The pulse wave variables were measured in Guan of all 1,056 subjects by the pulse analyzer, using a pen-type piezoresistive sensor. The physical measurement, blood test and survey were also performed by each subject. Results : In the age categories, height of pre-incisura (h2), height of tidal wave (h3), area of percussion wave (Aw), and width of percussion wave (w) increased in accordance with increase in age. While ratio of systolic period area (As) went up according to the increase of age, ratio of diastolic period area (Ad) went down. Radial augmentation index (R-AI), h2/h1, h3/h1, w/t and angle of percussion wave went up by aging, generally. Aw rate (Aw/At) also increased. Among the metabolic syndrome group, in the ages of 19 and 44, ratio of systolic period area (As) was higher and ratio of diastolic period area (Ad) was lower than in the non-metabolic group. w/t, Aw/At, and angle of percussion wave were higher than in the non-metabolic syndrome group. Among the metabolic syndrome group over the age of 60, height of pre-incisura (h2), height of tidal wave (h3), total area (At), area of percussion wave (Aw), radial augmentation index (R-AI), h2/h1 and h3/h1 were higher than in the non-metabolic syndrome group. Conclusions : The pulse analyzer is useful to analyze arterial stiffness in the age categories and in the metabolic syndrome group by some measures.

Lamb Wave Technique for Ultrasonic Nonlinear Characterization in Elastic Plates (판재의 초음파 비선형 특성평가를 위한 Lamb Wave 기법)

  • Lee, Tae-Hun;Kim, Chung-Seok;Jhang, Kyung-Young
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.30 no.5
    • /
    • pp.458-463
    • /
    • 2010
  • Since the acoustic nonlinearity is sensitive to the minute variation of material properties, the nonlinear ultrasonic technique(NUT) has been considered as a promising method to evaluate the material degradation or fatigue. However, there are certain limitations to apply the conventional NUT using the bulk wave to thin plates. In case of plates, the use of Lamb wave can be considered, however, the propagation characteristics of Lamb wave are completely different with the bulk wave, and thus the separate study for the nonlinearity of Lamb wave is required. For this work, this paper analyzed first the conditions of mode pair suitable for the practical application as well as for the cumulative propagation of quadratic harmonic frequency and summarized the result in for conditions; (1) phase matching, (2) non-zero power flux, (3) group velocity matching, and (4) non-zero out-of-plane displacement. Experimental results in aluminum plates showed that the amplitude of the secondary Lamb wave and nonlinear parameter growed up with increasing propagation distance at the mode pair satisfying the above all conditions and that the ration of nonlinear parameters measured in Al6061-T6 and Al1100-H15 was closed to the ratio of the absolute nonlinear parameters.

A Study on the Telescopic Cascode Comparator in SET Situation (SET 상황에서 텔레스코픽 캐스코드 비교기에 관한 연구)

  • Jang, Jae-Seok;Chung, Jae-Pil;Park, Jung-Cheul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.13 no.4
    • /
    • pp.277-282
    • /
    • 2020
  • This study was initiated to find a way to resolve electronic equipment as it could be affected by multiple environments. The effect of setting the exponential constant wave (iExp) in the telescopic cascade comparator to the SET (Single Event Transient) environment was tested. In this paper, the radio wave delay was measured at 0.46 ㎲ and the gain at 0.713 in the telescopic cascade comparator without setting the SET situation. FET T0 (M6) was measured to have a large spike at 11㎲ to 15㎲ in the telescopic cascade comparator entering the SET situation. FET T1 (M5) has shorted output signals from 10 ㎲ to 16 ㎲. FET T2 (M3) represented a shorted output signal, and FET T3 (M4) measured the output waveform in the form of a large spike waveform. The FET T4 (M1) and FET T5 (M2) are spiky signals. And at all FETs, the propagation delay was changed from 0.45㎲ to 0.54㎲. In summary, The FET element in the telescopic cascade comparator in SET situation was measured to be greatly affected.

Effect of Transcranial Direct Current Stimulation on University Student's Attention (경두개직류전류자극이 대학생의 집중력에 미치는 영향)

  • Oh, Myung Hwa;Lee, Eun Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.9
    • /
    • pp.127-132
    • /
    • 2019
  • This study examined the change in the attention of University students after being given Transcranial Direct Current Stimulation (tDCS). The participants were divided randomly into two group (tDCS vs. Control). tDCS was applied to 37 university students ($23.08{\pm}3.33years$). The tDCS group was applied 2 mA, for 13 minutes twice over a 26 minute period ($n_1=19$). The control ($n_2=18$) was not applied after padding and was applied twice for 13 minutes over a 26 minute period. This study was conducted from September 3 to 28, 2018 and three times a week for a total of four weeks. The electroencephalogram was confirmed to affect attention. tDCS showed significant improvement in the results in the sensory motor rhythm wave (p<0.01, 95% CI: -1.955, -0.459), middle beta wave (p<0.05; 95% CI: 0.027, 0.943), and power ratio (p<0.01, 95% CI: -1.764, -0.315). The results showed that tDCS application increased the attention ability significantly. These results can be applied to attention deficit disorder (ADHD) patients and college students.

Empirical Formula for Propagation Distance of Flood Wave-front in Flat Inundation Area without Obstacle due to Levee Breach (장애물이 없는 평탄지형 제내지에서의 범람홍수파 선단 전파거리 실험식 산정)

  • Yoon, Kwang-Seok;Lee, Jong-Kyu
    • Journal of Korea Water Resources Association
    • /
    • v.40 no.10
    • /
    • pp.833-840
    • /
    • 2007
  • The experimental study was carried out to investigate propagation distance of flood wave due to levee breach in a flat inundation area without obstacle. Hitter solution was considered to formulate the experimental results and a representative form was written referring to existing researches. As a result of experiments, it was found that the propagation velocity of the wave front in inundation area was significantly influenced by the initial water level in a channel, which was similar to flow in a channel due to dam break. An empirical formula was also suggested using the experimental results. The dimensionless propagation distance L can be written as the power function of dimensionless time T Coefficients k and m were varied with the dimensionless time T whereas k and m in Ritter solution were 2 and 0, respectively. The variation of coefficients in the relationship between L and T was influenced by the water depth in the inundation area and the fact proved that the changing points of L in the slope of relationship between L and T are the same to those of relationship between the dimensionless maximum water depth in the inundation area, $h_{max}$ and L.

Studies on electron Bernstein wave heating in CHS and LHD at NIFS

  • Yoshimura, Y.;Igami, H.;Margalet-Ferrando, S.;Nagasaki, K.;Kubo, S.;Shimozuma, T.;Isobe, M.;Suzuki, C.;Shimizu, A.;Akiyama, T.;Takahashi, C.;Nagaoka, K.;Nishimura, S.;Minami, T.;Matsuoka, K.;Okamura, S.;Mutoh, T.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2007.08a
    • /
    • pp.181-181
    • /
    • 2007
  • PDF