• Title/Summary/Keyword: T/S볼트

Search Result 26, Processing Time 0.022 seconds

Discrimination of Bolt and Nut's Presence in a T-Bar Using Image Processing Method (영상처리 방법을 이용한 T-Bar의 볼트와 너트 유무 판별)

  • Joo, Ki-See;Kim, Eun-Seok
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.5
    • /
    • pp.937-943
    • /
    • 2009
  • In this paper, the algorithm discriminating the existence and nonexistence of bolts and nuts using image processing in an automobile T-Bar influencing the vibration of a frame, is introduced. To distinct whether bolts and nuts exist or not, the features of bolts and nuts are learned, and then these feature values are matched using a statistical pattern matching algorithm. Furthermore, the minimum and maximum variation rate of pixel values are used since the matching rate is low with the large variation of pixel values of bolts and nuts in each image. The proposed method in this paper is very efficient in the automation of inspection requiring real time since the inspection time is significantly reduced compared with the conventional methods.

Compressive Stress Distribution of High Tension Bolted Joints (고장력 볼트 이음부의 내부 압축응력 분포)

  • Kim, Sung Hoon;Lee, Seung Yong;Choi, Jun Hyeok;Chang, Dong Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.9 no.2 s.31
    • /
    • pp.171-179
    • /
    • 1997
  • The high-tension bolted joints are clamped by the axial force which approaches the yielding strength. The introduced axial force is transmitted to the connection members pass through washer. The transferred load in connections is balanced to the compressive stress of plates, axial force in bolts and the external loads. In this mechanism, the compressive stress and slip load we dominated by the effective stiffness of bolted joints and plates. In general the effective stiffness is specified to product to the effective area and elasticity modulus in connections. In this reason, the conic projection formular which is assumed that the axial force in bolts is distributed to the cone shape and that region is related to the elastic deformation mechanism in connections, was proposed. But it conclude what kind of formula is justified. Therefore in this paper, the fatigue tests are performed to the high tension bolted joints and inspected to the phase on the friction face. And using the FEM and numerical method, it is analyzed and approximated to the compressive stress distribution and its region. Moreover, it is estimated to the effective area and to the relation the friction area to the effective compressive distribution region.

  • PDF

Experimental study on the Behavior CFT Column to H-Beam Endplate Connections with Penetrated High Strength Bolts (II) (관통형 고력볼트를 사용한 엔드플레이트형식 콘크리트 충전 각형강관 기둥.H형강 보 접합부의 거동에 관한 실험적 연구 (II))

  • Kim, Jae Keon;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.11 no.2 s.39
    • /
    • pp.109-116
    • /
    • 1999
  • This paper presents an experimental study on the behavior of CFT Column to H-Beam Endplate Connections with penetrated H/T bolts under monotonic loading. The object of this study is to estimate accurately the effect about the thickness of endplate and the arrangement of H/T bolts which was not got a grip on the results reported in the previous paper. Main parameters are the thickness of endplates (12mm, 16mm) and the arrangemement of H/T bolts (EP1, EP2, EP3 Type). The experimental results compared and analysed. 1) The specimens were classified by Bjorhovde's and EC3's method. 2) A formula to predict the ultimate moment of connection was derived based on the T-stub model, and theoretical value $(_tM_u)$ computed by the formula corresponded to the experimental value $(_eM_u)$.

  • PDF

An Analytical Study on the Strength Behavior of Column-Foundation Connection with High Tension Bolts (고장력 볼트 기둥-기초 연결부의 강도특성에 관한 해석적 연구)

  • Hwang, Dong A;Hwang, Won Sup;Ham, Jun Su;Jeong, Jin Il
    • Journal of Korean Society of Steel Construction
    • /
    • v.28 no.2
    • /
    • pp.121-128
    • /
    • 2016
  • In order to suggest a reasonable design for the circular concrete filled tube steel column-foundation connection applying high-tension bolts, Overall structural behavior and characteristics according to various variables of column-foundation connection are numerically analyzed using a commercial FE analysis program, ABAQUS. To that goal, finite element analysis is conducted on the basis of the previous study replacing anchor bolts to high-tension bolts, and the analytical results are validated by comparison with experimental results. Also, the various variables(embedded depth and grade of anchor, and height and thickness of rib) involved in behavior of the column-foundation connection are selected through analyzing the current design criteria, and the characteristics of the column-foundation connection are compared and analyzed according to the various variables. In case of the anchor bolts, Applying the high-tension bolts is more advantage and securing the embedded depth beyond 0.5D is recommendable. In case of the rib, a minimum of 0.5D for rib's height and $0.4t_b$ for rib's thickness should be secured to develop the structural performance.

Structural Tensile Capacities of Split-Tee Connection with High Strength Bolts (고력볼트 Split Tee 접합부의 인장내력)

  • Choi, Hye Kyoung;Choi, Sung Mo;Kim, Jin Ho
    • Journal of Korean Society of Steel Construction
    • /
    • v.15 no.5 s.66
    • /
    • pp.541-549
    • /
    • 2003
  • Split-tee connection with High Strength Bolts is normally used in low and middle rise buildings in Europe because the structural efficiency and installation work of connections are excellent. However, the domestic situation is different from that in Europe. The analysis and the design for the T-split connection are complicated, because the structural behavior often T-split connection with High Strength Bolt is governed by so many parameters, i.e., prying action, bolt's tension, shear failure and plastic failure of flange plates. Many researches regarding the structural behavior of the split-tee connection have been undertaken in other parts of the world, such as the, Americas, Japan and Europe, but in the domestic context, this is a pioneering study. Therefore, the purpose of this paper is to supply basic data for the design of T-split connection, and to verify the structural characteristics that define reactions to prying action, based on an experimental study.

A Comparison Study for the Fatigue Behavior of H/T and T/S Bolt Friction Joint (H/T 와 T/S 볼트 마찰이음의 피로거동 비교·검토)

  • JUN, Je Sang;WOO, Sang Ik;LEE, Seong Heang;JUNG, Kyoung Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.8 no.3 s.28
    • /
    • pp.139-150
    • /
    • 1996
  • H/T(High Tension) bolt is generally being used in joining the members of steel structure. It has some difficulties in management such as an adequate fastening force and a selection of proper instrument for fastening. T/S(Torque Shear Type High Tension) bolt which is more convenient and easier than H/T bolt in quality control has recently been developed. T/S bolts are produced and widely used these days in domestic, but those have not a detail regulation for their on. Those are only being used according to the specification for the H/T bolts. In this study, we tried to confirm the soundness of T/S bolts by the fatigue test of the modified specimens. First, we measured the reduction rate of the initial axial force with time at bolts. Second, we investigated the slip forces of bolts when the test specimen is loaded in tension. Third, we implemented the fatigue tests. During the test, we measured the variation of the axial forces of bolts under the cyclic loading. Finally, we compared and analyzed the fatigue behavior of H/T and T/S bolt, by S-N curve diagrams that are obtained in this study.

  • PDF

스파부이의 유실방지 및 기능개선 방안

  • Yu, Jong-Seong;Gong, Hyeon-Dong;Kim, Hae-Geun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2012.10a
    • /
    • pp.414-416
    • /
    • 2012
  • 항로표지는 선박의 안전한 통항로 확보를 위한 필수적인 항해 보조시설이며, 세계 주요 5대 항만에 포함되는 부산항은 2006부터 입 출항 항로표의 정확한 법선 표시를 위해 스파부이(LSP-28)를 설치 운영중에 있으나 매년 선박 충돌 및 자연 유실로 2~3기의 유실사고가 발생하고 있다. 항로표지의 국제적 신뢰성 확보 및 관리 효율성을 강화하기 위하여 원인 분석과 기능 개선방안을 모색하였다.

  • PDF

Manufacturing Process Design of High Strength Al 6056 Bolts by Strain Hardening Effect (가공경화를 이용한 고강도 Al 6056 볼트의 생산 공정설계)

  • Park, J.S.;Kim, Y.B.;Kim, S.W.;Kim, H.S.;Ann, K.H.;Park, J.S.;Kang, J.H.
    • Transactions of Materials Processing
    • /
    • v.30 no.4
    • /
    • pp.165-171
    • /
    • 2021
  • This study was conducted on the manufacturing method of high-strength aluminum bolts. We obtained the displacement-load information by tensile test of the Al 6056 raw material and the T6 heat-treated material and calculated the precise flow stress and fracture limit using repetitive finite element analysis for before and after heat treatment. We designed a multi-stage forging process for T6 heat-treated material, and calculated that the accumulated damage value does not exceed fracture limits by finite element method. We produced the prototype forgings without any harmful defects such as cracks and folding occurring. Bolts made of T6 heat treated material show 9.6%higher tensile strength than T6 heat treated material after wire drawing.

The Static Strength Analysis of Prying Action for T-flange Shape Structure Using F10T High Strength Bolt (F10T 고장력 볼트를 이용한 T-형 플랜지형 구조물의 Prying Action에 따른 정적강도 해석)

  • Park, Myung-Kyun;Lee, Joong-Won;Koo, Bon-Sung
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.19-24
    • /
    • 2008
  • This paper presents and discusses the experimental results on the F10T high strength bolts used in the T-flange joint structure. The experimental works were carried out for the parameters which are flange web thickness, the distance between bolts, prying ratio. The results show that the working stress imposed to bolts decreases as the flange web thickness increases on the other hand the imposed stress to the bolts increases as the distance between two bolts increases. In other words the strength of the T-flange joint increased as the web flange thickness increases and the distance between two bolts decreases. The prying ratio is increased as the distance between two bolts increases and as the flange web thickness decreases However, the degree of stress decrease in flange thickness variation is not that high as the distance variation between two bolts. Finally the equation for predicting the failure stress in T-flange joint structure using F10T high strength bolts was suggested.