• 제목/요약/키워드: System Code

검색결과 6,253건 처리시간 0.067초

LLR-based Cooperative ARQ Protocol in Rayleigh Fading Channel (레일리 페이딩 채널에서 LLR 기반의 협력 ARQ 프로토콜)

  • Choi, Dae-Kyu;Kong, Hyung-Yun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • 제45권4호
    • /
    • pp.31-37
    • /
    • 2008
  • Conventional cooperative communications can attain gain of spatial diversity and path loss reduction because destination node independently received same signal from source node and relay node located between source node and destination node. However, these techniques bring about decreased spectral efficiency with relay node and increased complexity of receiver by using maximal ratio combining (MRC). This paper has proposed cooperative ARQ protocol that can improve the above problems and can get the better performance. This method can increase the spectral efficiency than conventional cooperative communication because if the received signal from source node is satisfied by the destination preferentially, the destination transmits ACK message to both relay node and source node and then recovers the received signal. In addition, if ARQ message indicates NACK relay node operates selective retransmission and we can increase reliability of system compared with that of general ARQ protocol in which source node retransmits data. In the proposed protocol, the selective retransmission and ARQ message are to be determined by comparing log-likelihood ratio (LLR) computation of received signal from source node with predetermined threshold values. Therefore, this protocol don't waste redundant bandwidth with CRC code and can reduce complexity of receiver without MRC. We verified spectral efficiency and BER performance for the proposed protocol through Monte-Carlo simulation over Rayleigh fading plus AWGN.

Numerical Analysis of the Complex Permittivity of MWNT added Epoxy Depending on Agglomeration Size (에폭시 내부의 MWNT 응집 크기에 따른 복소유전율 변화의 해석적 관찰)

  • Shin, Jae-Hwan;Jang, Hong-Kyu;Choi, Won-Ho;Song, Tae-Hoon;Kim, Chun-Gon;Lee, Woo-Yong
    • Composites Research
    • /
    • 제27권5호
    • /
    • pp.190-195
    • /
    • 2014
  • This paper predicts the complex permittivity of MWNT added epoxy depending on agglomeration by numerical analysis. 1wt% MWNT added epoxy specimen is prepared using 3-roll-mill method and its complex permittivity is measured in X-band (8.2~12.4 GHz) using freespace measurement system. The analytic model is comprised of cube epoxy and perfect sphere agglomeration. The complex permittivity of the agglomeration model is predicted by complex permittivity mixing rule using the measured complex permittivity of epoxy and 1 wt% MWNT added epoxy. Commercial electromagnetic analysis software, CST, is used to obtain S-parameter of the analytic model and MATLAB code is used to calculate complex permittivity from the S-parameter. It is confirmed that the complex permittivity increases when the agglomeration size decreases.

Implementation of LDPC Decoder using High-speed Algorithms in Standard of Wireless LAN (무선 랜 규격에서의 고속 알고리즘을 이용한 LDPC 복호기 구현)

  • Kim, Chul-Seung;Kim, Min-Hyuk;Park, Tae-Doo;Jung, Ji-Won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제14권12호
    • /
    • pp.2783-2790
    • /
    • 2010
  • In this paper, we first review LDPC codes in general and a belief propagation algorithm that works in logarithm domain. LDPC codes, which is chosen 802.11n for wireless local access network(WLAN) standard, require a large number of computation due to large size of coded block and iteration. Therefore, we presented three kinds of low computational algorithms for LDPC codes. First, sequential decoding with partial group is proposed. It has the same H/W complexity, and fewer number of iterations are required with the same performance in comparison with conventional decoder algorithm. Secondly, we have apply early stop algorithm. This method reduces number of unnecessary iterations. Third, early detection method for reducing the computational complexity is proposed. Using a confidence criterion, some bit nodes and check node edges are detected early on during decoding. Through the simulation, we knew that the iteration number are reduced by half using subset algorithm and early stop algorithm is reduced more than one iteration and computational complexity of early detected method is about 30% offs in case of check node update, 94% offs in case of check node update compared to conventional scheme. The LDPC decoder have been implemented in Xilinx System Generator and targeted to a Xilinx Virtx5-xc5vlx155t FPGA. When three algorithms are used, amount of device is about 45% off and the decoding speed is about two times faster than convectional scheme.

A Study on the Amendments of the Cathodic Protection Criteria Considering IR Drops (전압강하를 고려한 전기방식 기준 개정에 관한 연구)

  • Ryou, Young-don;Lee, Jin-han;Jo, Young-do;Kim, Jin-Jun
    • Journal of the Korean Institute of Gas
    • /
    • 제20권4호
    • /
    • pp.50-57
    • /
    • 2016
  • According to the urban gas business legislation, cathodic protection systems should be applied for buried steel gas pipelines to prevent corrosion. In advanced countries including United States, the criteria for Cathodic Protection Potential is at least -850mV with respect to a saturated copper/copper sulfate electrode(CSE) when the CP applied, and the IR drops must be considered for valid interpretation. However, the IR drop through the pipe to soil boundary has been neglected in Korea. According to KGS code, a reference electrode must be placed in proximity to gas pipelines possible when measuring the CP potential. In this study, we have installed several solid reference electrodes around the buried pipeline(1.2m depth), lower surface(0.5m depth), and the surface individually in order to measure the CP potentials through the each reference electrode and find out the IR drops according to the location of each reference electrode. We have found the IR drop is the greatest when measuring the CP potential through the electrode placed on the ground and the IR drop is the smallest through the electrode installed near pipeline. Therefore, we have suggested the solid reference electrode should be installed as close as possible to buried pipeline in order to measure the correct CP potential without IR drop. We have also suggested the amendment of CP criteria considering IR drop.

A Study on the Ultimate Strength Behavior for Ship Perforated Stiffened Plate (선체 유공보강판의 최종강도 거동에 관한 연구)

  • Ko Jae-Yong;Lee Jun-Kyo;Park Joo-Shin;Bae Dong-Kyun
    • Proceedings of KOSOMES biannual meeting
    • /
    • 해양환경안전학회 2005년도 춘계학술발표회
    • /
    • pp.141-146
    • /
    • 2005
  • Ship have cutout inner bottom and girder and floor etc. Ship's structure is used much, and structure strength must be situated, but establish new concept when high stress interacts sometimes fatally the area. There is no big problem usually by aim of weight reduction, a person and change of freight, piping etc. Because cutout's existence grow up in this place, and, elastic buckling strength by load causes large effect in ultimate strength. Therefore, stiffened perforated plate considering buckling strength and ultimate strength is one of important design criteria which must examine when decide structural concept at initial design. Therefore, and, reasonable buckling strength about perforated stiffened plate need to ultimate strength limited design . Calculated ultimate strength varied several web height and cutout's dimension, and thickness in this investigated data. Used program(ANSYS) applied F.E.A code based on finite element method.

  • PDF

Effect of Grid, Turbulence Modeling and Discretization on the Solution of CFD (격자, 난류모형 및 이산화 방법이 유동해석 결과에 미치는 영향)

  • Park, Dong-Woo;Yoon, Hyun-Sik
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • 제20권4호
    • /
    • pp.419-425
    • /
    • 2014
  • The current work investigated the variation of numerical solutions according to the grid number, the distance of the first grid point off the ship surface, turbulence modeling and discretization. The subject vessel is KVLCC. A commercial code, Gridgen V15 and FLUENT were used the generation of the ship hull surface and spatial system and flow computation. The first part of examination, the effect of solutions were accessed depending on the grid number, turbulence modeling and discretization. The second part was focus on the suitable selection of the distance of the first grid point off the ship surface: $Y_P+$. When grid number and discretization were fixed the same value, the friction resistance showed differences within 1 % but the pressure resistance showed big differences 9 % depending on the turbulence modeling. When $Y_P+$ were set 30 and 50 for the same discretization, friction resistance showed almost same results within 1 % according to the turbulence modeling. However, when $Y_P+$ were fixed 100, friction resistance showed more differences of 3 % compared to $Y_P+$ of 30 and 50. Whereas pressure resistance showed big differences of 10 % regardless of turbulence modeling. When turbulence modeling and discretization were set the same value, friction, pressure and total resistance showed almost same result within 0.3 % depending on the grid number. Lastly, When turbulence modeling and discretization were fixed the same value, the friction resistance showed differences within 5~8 % but the pressure resistance showed small differences depending on the $Y_P+$.

Radiation Field in PWR Plants (PWR 발전소에서의 방사선장 특성)

  • Song, Myung-Jae;Kim, Hee-Keun;Kim, Bong-Hwan;Chang, Si-Young
    • Journal of Radiation Protection and Research
    • /
    • 제17권2호
    • /
    • pp.61-70
    • /
    • 1992
  • Photon, neutron and beta radiation fields were measured at PWR plants which are the representative types of nuclear power plant operated in Korea. The photon energy spectra were measured at locations in the auxiliary building during operation period and in the containment vessel(C/V) during shutdown period using a portable gamma spectrometer with a HPGe detector. The distribution of average energy was found to range from 440 to 780 keV in the C/V and from 280 keV to 760 keV in the auxiliary building, respectively. The average neutron energy measured at the five locations around the operation deck in the C/V in operation using a BMSS (Bonner Multi-Sphere Spectrometer) ranged from 20 keV to 210 keV. A computer code, BUNKI was used to unfold the spectrum. The beta energy spectra in the C/V and in the auxiliary building in annual outage were determined using 14 smear samples taken from the highly contaminated areas. The analysis showed that the representative corrosion product, $^{60}Co$ made main contribution to the beta energy field.

  • PDF

A dryout mechanism model for rectangular narrow channels at high pressure conditions

  • Song, Gongle;Liang, Yu;Sun, Rulei;Zhang, Dalin;Deng, Jian;Su, G.H.;Tian, Wenxi;Qiu, Suizheng
    • Nuclear Engineering and Technology
    • /
    • 제52권10호
    • /
    • pp.2196-2203
    • /
    • 2020
  • A dryout mechanism model for rectangular narrow channels at high pressure conditions is developed by assuming that the Kelvin-Helmholtz instability triggered the occurrence of dryout. This model combines the advantages of theoretical analysis and empirical correlation. The unknown coefficients in the theoretical derivation are supported by the experimental data. Meanwhile, the decisive restriction of the experimental conditions on the applicability of the empirical correlation is avoided. The expression of vapor phase velocity at the time of dryout is derived, and the empirical correlation of liquid film thickness is introduced. Since the CHF value obtained from the liquid film thickness should be the same as the value obtained from the Kelvin-Helmholtz critical stability under the same condition, the convergent CHF value is obtained by iteratively calculating. Comparing with the experimental data under the pressure of 6.89-13.79 MPa, the average error of the model is -15.4% with the 95% confidence interval [-20.5%, -10.4%]. And the pressure has a decisive influence on the prediction accuracy of this model. Compared with the existing dryout code, the calculation speed of this model is faster, and the calculation accuracy is improved. This model, with great portability, could be applied to different objects and working conditions by changing the expression of the vapor phase velocity when the dryout phenomenon is triggered and the calculation formula of the liquid film.

ICFGO : UI Concealing and Dummy Flow Insertion Method for Inter-Procedural Control Flow Graph Obfuscation (ICFGO : Inter-Procedural Control Flow Graph 난독화를 위한 UI 은닉 및 Dummy Flow 삽입 기법)

  • Shim, Hyunseok;Jung, Souhwan
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • 제30권3호
    • /
    • pp.493-501
    • /
    • 2020
  • For the obfuscation of Flow Analysis on the Android operating system, the size of the Flow Graph can be large enough to make analysis difficult. To this end, a library in the form of aar was implemented so that it could be inserted into the application in the form of an external library. The library is designed to have up to five child nodes from the entry point in the dummy code, and for each depth has 2n+1 numbers of methods from 100 to 900 for each node, so it consists of a total of 2,500 entry points. In addition, entry points consist of a total of 150 views in XML, each of which is connected via asynchronous interface. Thus, the process of creating a Inter-procedural Control Flow Graph has a maximum of 14,175E+11 additional cases. As a result of applying this to application, the Inter Procedure Control Flow Analysis too generates an average of 10,931 edges and 3,015 nodes with an average graph size increase of 36.64%. In addition, in the APK analyzing process showed that up to average 76.33MB of overhead, but only 0.88MB of execution overhead in the user's ART environment.

Subcriticality Evaluation Using the Modified Neutron Source Multiplication Method (개선된 중성자 선원 증배법을 이용한 미임계도 평가)

  • Yoon, Seok-Kyun;Naing, Win;Kim, Myung-Hyun
    • Journal of Energy Engineering
    • /
    • 제16권4호
    • /
    • pp.155-163
    • /
    • 2007
  • To insure nuclear reactor safety, the reactivity of control rods should be calculated by measuring the criticality of reactor core and it is regularly performed during the annual physics test period. Also, the core criticality should be monitored during the start-up operation to avoid reactivity induced accidents. Many research works on control rod reactivity measurement and subcriticality measurement have been accomplished throughout the world for decades and recently a new method named "Modified Neutron Source Multiplication Method (MNSM)" was proposed in Japan which is known to be improved overcoming limitations of traditional Neutron Source Multiplication Method (NSM). In this study, MNSM was tested in calculation of subcriticalities and in evaluation of application validity using the educational reactor in Kyung Hee University, AGN-201. For this study, a revised nuclear data library and a neutron transport code system TRANSX - PARTISN were established. Correction factors for various control rod positions were produced using the k-effective values and the corresponding flux distributions and adjoint flux distributions. Experimental values of the core criticality were obtained using the neutron count rates of the BF3 proportional counters. The results showed that the expected reactivity worth of control rods by MNSM agreed well with the theoretical values and the correction factors contributed much for this purpose.