• 제목/요약/키워드: System Capacity

검색결과 8,732건 처리시간 0.036초

초전도기기를 적용한 미래 저압대용량 신 배전계통 (Future New Distribution System with Low voltage and Mass Capacity using HTS equipments)

  • 윤재영;김종율;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제7권1호
    • /
    • pp.37-41
    • /
    • 2005
  • This paper describes the construction scheme of new distribution system using HTS(High Temperature Superconducting) power equipments such as cable, transformer and FCL(fault current limiter). At present, one of the most serious problems in distribution power system, especially for metropolitan complex city, is to obtain the ROW for cable line routes, space for downtown substations and satisfy the environmental protection caused by NIMBY phenomena. Unfortunately, it is expected that this situation will get more and more worse. As the HTS technology to apply in power system Is developed, HTS cable utilizing mass-capacity characteristic can be a useful countermeasure to overcome this problem. This paper describes the application methodology of 22.9kV HTS cable with low-voltage, mass-capacity characteristics replacing the 154kV conventional cable. By applying 22.9kV HTS cable, the HTS transformer with higher capacity for the reduction of space and transformer numbers of downtown substation is necessary. Also, if the leakage Impedance of HTS transformer is same as or lower than that of conventional transformer, the fault current of 22.9kV bus will increase because the HTS transformer capacity is larger than that of the conventional transformer. This means the parallel application of HTS-FCL to reduce the fault current in addition to the HTS cable and transformer can be necessary. With the basic construction scheme of new distribution system, this paper describes the future study points to realize this new distribution system using HTS equipments.

다중빔 위성 통신 시스템에서 빔간 직교 코드 공유 기법과 동적 무선 자원 할당 (Orthogonal Code Sharing and Radio Resource Allocation in Multibeam Satellite Communication Systems)

  • 임광재;김수영;오덕길;김재명
    • 한국통신학회논문지
    • /
    • 제28권3A호
    • /
    • pp.140-150
    • /
    • 2003
  • 본 논문에서는 다중빔 정지궤도 위성을 이용한 이동 위성 시스템에서, 하향 링크 용량 증대를 위해 빔간 직교 코드를 공유하는 방법과, 제안된 시스템을 위한 무선 자원 및 전력 할당 방법을 제시한다. 또한, 하향 링크 용량에 대한 간단한 이론적 분석과 다중빔 위성 시스템에 대한 시뮬레이션을 통하여 제시된 시스템의 용량 증대 효과를 보인다. 기존의 확산 코드 사용 방법을 적용한 다중빔 위성 시스템에 대해 제안된 시스템은 약 2 배 이상의 용량 증대 효과를 보이며, 주파수 선택적 페이딩 채널에 의해 기인하는 직교 코드 사이의 상호 간섭이 적을수록 그 효과는 증대된다.

상관 MIMO 페이딩 채널에서 Multi-Carrier CDMA 시스템의 용량 평가 (Capacity Evaluation of Multi-Carrier CDMA System in Correlated MIMO Fading Channel)

  • 노재성;조성준;김춘길
    • 한국항행학회논문지
    • /
    • 제7권1호
    • /
    • pp.51-58
    • /
    • 2003
  • 일반적으로 다중경로는 무선통신에서 불필요한 특징을 나타낸다. 따라서 이러한 영향을 극복하기 위하여 다이버시티 수신이나 적응 어레이 기법이 제안되었다. 최근에는 스펙트럼 효율과 링크 신뢰도를 증가시키기 위해 MIMO 기법이 산란 무선 채널에서 다중경로를 이용하기 위해 고안되었다. 본 논문에서는 경로 상관 페이딩 채널에서 MIMO Multi-Carrier CDMA 시스템의 채널 용량을 평가한다. 그리고 MIMO 시스템의 채널 용량을 SISO 시스템의 채널 용량과 비교한다. 결과로부터 경로 상관을 갖는 MIMO Multi-Carrier CDMA 시스템은 SISO 시스템의 채널 용량에 비하여 우수함을 알 수 있다.

  • PDF

혼합냉매의 성분비 조절을 통한 열펌프의 용량조절 (Capacity Modulation of a Heat Pump System by Changing the Composition of Refrigerant Mixtures)

  • 김민성;김민수;김용찬
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.258-266
    • /
    • 2000
  • Experimental investigation and cycle simulation of a capacity modulation of a heat pump system using a hydrofluorocarbon (HFC) refrigerant mixture, R32/134a as an alternative to R22, have been done. In the cycle simulation, the refrigeration system was operated by assigning the temperatures of the external heat transfer fluids with the heat exchangers generalized by an average effective temperature difference. Heating capacity, cooling capacity, and coefficient of performance (COP) of the system were investigated at several operating conditions. Experimental apparatus which had a refrigeration part and a composition changing part was built, and the performance of the heat pump system filled with R32/134a mixture was investigated. A gas-liquid separator was used in the experiment to change the composition by collecting the vapor and the liquid Phase separately, The mass fraction of the charged refrigerant in the heat pump system was 40/60 and 70/30 by weight percentage. The composition of the refrigerant with initial composition of 40/60 varied from 29/71 to 41/59 in the refrigeration cycle. For the refrigerant with initial composition of 70/30, the composition varied from 65/35 to 75/25.

  • PDF

열펌프-잠열축열 시스템 온실에서 토양의 열저장 및 방열 특성 (Thermal Energy Storage and Release Characteristics of the Soil in the Greenhouse Equipped with Heat Pump and Latent Heat Storage System)

  • 노정근;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제27권1호
    • /
    • pp.39-44
    • /
    • 2002
  • In order to obtain the information of bio-environment control, the thermal characteristics of soil in the greenhouse heated by the heat pump and latent heat storage system were experimentally analyzed. The experimental systems were composed of the greenhouse with a heat pump and a latent heat storage system (system I), the greenhouse with a heat pump (system II), the greenhouse with a latent heat storage system (system III), and the greenhouse without auxiliary heating system (system IV). The thermal characteristics experimentally analyzed in each system were temperature of soil layers, soil heat storage and release, soil heat capacity and soil heat storage ratio. The results could be summarized as follows. 1. Time to reach the highest temperature at 20cm deep in soil layers of the crop routs in case of system I was shown to be delayed by 6 hours in comparison to the time of the highest temperature at the soil surface. 2. In the clear winter days, the stored heat capacity values fur the system I and the system II were shown to be 22.3% and 11.0% higher than the released heat capacity respectively, and the stored heat capacity values for the system III and the system IV were shown to be 6.2% and 29.6% lower than the released heat capacity respectively This confirms that the system I provided the best heat storage effect. j. The heat quantity values stored or released were shown to be highest at 5 cm depth of soil layers. And it was reduced with increasing of depth of soil layers until 20 cm and was not changed under the soil layer of 20 cm depth. 4. The heat absorption rates of soil, the ratio between supplied and stored heat energy, fur both the system I and system II were lower than 23%.

지반파괴거동에 따른 마이크로파일-기초의 지지특성 (Bearing Characteristics of Micropile-raft by Failure Mode of Soil)

  • 황태현;신종호;허인구;권오엽
    • 한국지반공학회논문집
    • /
    • 제31권2호
    • /
    • pp.13-25
    • /
    • 2015
  • 최근 마이크로 파일의 활용 빈도가 점차 증가함에 따라 몇몇 연구자들은 마이크로파일 및 마이크로파일-기초에 대한 관련 연구를 수행하였다. 그러나 대부분의 관련연구는 모래지반을 대상으로 한 경우이다. 또한 마이크로파일-기초시스템의 지지특성은 기초시스템내 하부지반의 파괴거동과 파일설치조건에 따라 기초시스템의 지지력이 달라지나 이를 고려하지 않고 있다. 따라서 본 연구에서는 파괴거동이 상이한 지반에 설치된 마이크로파일-기초시스템의 지지력을 평가위해 수치해석을 수행하였다. 해석결과, 전면전단파괴가 발생한 모래지반에서는 기초시스템의 파일을 양 또는 음의 각도로 설치한 경우가 수직파일로 설치된 기초시스템보다 큰 것으로 나타났다. 관입파괴형상으로 파괴가 발생한 실트지반의 경우, 파일이 교차하도록 음의 각도로 설치한 기초시스템이 수직파일인 경우보다 지지력이 증가하였다. 그리고 양의 각도로 설치한 경우에는 수직인 경우와 유사한 것으로 나타났다.

수정된 능력스펙트럼을 이용한 건축구조물의 내진성능평가 (Seismic Performance Evaluation of Building Structures Using Modified Capacity Spectrum)

  • 최원호
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.267-274
    • /
    • 2000
  • Current seismic design codes for building structures are based on the method which can provide enough capacity to satisfy objected performance level and exactly evaluate the seismic performance of buildings. The capacity spectrum method using the nonlinear static(pushover) analysis is becoming a popular tool for evaluating the seismic performance of existing and new building structures. By means of a graphical procedure capacity spectrum method esimates the performance level of structure by comparing the capacity of structure with the demand of earthquake ground motion on the structure. In the method the relation between base shear estimated by a nonlinear static analysis and horizontal displacement is used. Capacity spectrum is usually expressed as what represent the responses of the equivalent single degree of freedom (ESDOF) system for the building structures. However there are some problems in converting procedures into ESDOF system which include not considering the effect of higher modes of structures. The objective of this paper is to compare and verify existing methods and suggest the modified capacity spectrum for seismic performance evaluation of building structures.

  • PDF

합성구조체의 경계면 슬립이 거동과 성능에 미치는 영향 (Effects of Slip for Interface on Behavior and Capacity in Hybrid Structure)

  • 정연주;정광회;김병석
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.385-390
    • /
    • 2001
  • This paper presents a nonlinear analysis technique with slip, the effects of slip modulus and composite action by shear connector on behavior and capacity in composite structure of sandwich system. As a results of this study, it proved that the slip modulus, in case of shear behavior, seldom influence load-resistance capacity such as yield and ultimate load, but in case of flexural behavior, it appropriately influence load-resistance capacity because of stress redistribution by slip. In case of flexural behavior, analysis result for perfect-composite results in over-estimation and perfect-slip results in under-estimation on behavior and capacity. Therefore, it is desirable to model steel-concrete interface with partial-composite. The effects of slip on behavior and capacity are less in case of positive composite than loosely composite, and it proved that composite action by shear connector improve the load-resistance capacity of this system.

  • PDF

공동주택의 성능기반설계 시 내진철근의 영향평가 (Performance Based Seismic Design of Apartment Houses by Applying Seismic Rebar)

  • 조민주;유성용;강지연;김형근
    • 한국공간구조학회논문집
    • /
    • 제17권4호
    • /
    • pp.115-122
    • /
    • 2017
  • In this study, performance based seismic design was performed on the shear wall structural system and the beam-column system as a variable general rebar and seismic rebar, and comparing the capacity of the two models of each system. From nonlinear analyses, the capacity of the shear wall structural system applying seismic rebar has shown a stable behavior after the maximum strength, but there is little difference. Furthermore, both models showed similar capacity between story drift and story shear force and capacity of members. These results are attributed to the fact that the seismic rebar, which is highly ductile under the seismic load applied to the target structure, does not render sufficient capacity.

전력계통 주파수응답 기여도 기반의 전기저장장치 주파수추종서비스 유효용량 산정 (Effective Capacity Calculation of the Electrical Energy Storage providing the Primary Frequency Control Service based on the Contribution to the Frequency Response of Power Systems)

  • 임현옥;최우영;권한나;국경수
    • 전기학회논문지
    • /
    • 제66권11호
    • /
    • pp.1561-1567
    • /
    • 2017
  • This paper calculates the effective capacity of EES providing the primary frequency control service based on its contribution to the frequency response of the power system. The amount of governor response from conventional generators which can be replaced by the primary frequency control from EES keeping the frequency response of the power system is defined as the effective capacity. The proposed method for calculating the effective capacity of EES is verified through case studies employing Korean power system. Furthermore, the application of the effective capacity of EES to power system operation is also discussed.