• Title/Summary/Keyword: System shutdown

Search Result 276, Processing Time 0.022 seconds

Development of Self-Actuated Shutdown System Using Curie Point Electromagnet

  • Kim, Tae-Ryong;Park, Jin-Ho
    • Nuclear Engineering and Technology
    • /
    • 제31권6호
    • /
    • pp.1-7
    • /
    • 1999
  • An innovative concept for a passive reactor shutdown system, so called self-actuated shutdown system(SASS), is inevitably required for the inherent safety in liquid metal reactor, which is designed with the totally different concept from the usual reactor shutdown system in LWR. SASS using Curie point electromagnet(CPEM) was selected as the passive reactor shutdown system for KALIMER (Korea Advanced Liquid MEtal Reactor). A mock-up of the SASS was designed, fabricated and tested. From the test it was confirmed that the mockup was self-actuated at the Curie point of the temperature sensing material used in the mockup. An articulated control rod was also fabricated and assembled with the CPEM to confirm that the control rod can be inserted into core even when the control rod guide tube is deformed due to earthquake. The operability of SASS in the actual sodium environment should be confirmed in the future. All the design and test data will be applied to the KALIMER design.

  • PDF

셧다운제도에 대한 청소년의 인식과 정책에 관한 연구 (A Study on Cognition and Policy of Shutdown System of Adolescent)

  • 이영주
    • 디지털융복합연구
    • /
    • 제9권3호
    • /
    • pp.21-29
    • /
    • 2011
  • 본 연구는 최근 온라인게임으로 인해 부작용이 심각한 수준에 이르고 있는 청소년의 현실을 반영하여 심야시간에 게임접속을 제한하여 과도한 게임이용으로부터 청소년을 보호하기 위해 온라인 게임서비스 이용시간을 일부 제한하는 셧다운제도의 도입에 대한 청소년들의 인지도와 게임중독의 심각성인지정도, 셧다운제도의 효과성과 문제, 그리고 대안정책 등에 대해 알아보고자 하였다. 조사결과, 청소년의 17.5% 만이 셧다운제도에 대해 인지하고 있었다. 또한 청소년들은 게임중독에 대해 매우 심각한 것으로 인지하고는 있었으나 셧다운제도 도입의 효과성에는 절반정도만 효과적이라 응답했다. 셧다운제도 도입과 관련된 정책대안으로, 첫째, 공교육의 확립으로 청소년들이 입시경쟁 속에 많은 시간 사교육에 노출되는 것을 막아야 할 것이다. 둘째, 일상의 규제는 가정이 주체이고 가정에서 관리하는 것이 바람직한 만큼 가정교육 프로그램의 개발로 부모와 자녀 간 대화시간을 늘리는 것이 필요하다. 마지막으로 청소년의 여가문화 컨텐츠 개발과 보급의 활성화가 이루어져야 할 것이다.

원자력발전소 영구정지 시 소내전력공급계통 운영방안 (An Operating Strategy of In-house Power Supply Systems in the Permanent Shutdown Nuclear Power Plant)

  • 임희택;이광대;전당희;윤종현;주익덕
    • 전기학회논문지
    • /
    • 제67권2호
    • /
    • pp.337-342
    • /
    • 2018
  • Spent fuel is moved from the reactor into the spent fuel pool when nuclear power plant permanently shutdown. The sole function of a permanently defueled facility is to store spent fuel in a quiescent state. The function of electric system and loads are reduced. It is necessary to establish an operating strategy of electric system in the permanent shutdown nuclear plant. This paper reviews required loads and design criteria considering transition to permanent shutdown. An operating strategy of onsite electric system is proposed considering decommissioning strategy and stage of defueled condition.

이중연료엔진의 연료가스공급시스템에 대한 안전무결도 기반 안전계장시스템 설계 (SIS Design for Fuel Gas Supply System of Dual Fuel Engine based on Safety Integrity Level(SIL))

  • 강낙원;박재홍;정정호;나성
    • 대한조선학회논문집
    • /
    • 제49권6호
    • /
    • pp.447-460
    • /
    • 2012
  • In this study, the shutdown system of the fuel gas supply system is designed based on the Safety Integrity Level of IEC 61508 and IEC 61511. First of all, the individual risk($10^{-4}$/year) and the risk matrix which are the risk acceptance criteria are set up for the qualitative risk assessment such as the HAZOP study. The natural gas leakage at the gas supply pipe is identified as the highest risk among the hazards identified through the HAZOP study and as a safety instrumented function the shutdown function for leakage was defined. SIL 2 and PFD($2.5{\cdot}10^{-3}$) for the shutdown function are determined by the layer of protection analysis(LOPA). The shutdown system(SIS) carrying out the shutdown function(SIF) is verified and designed according to qualitative and quantitative requirements of IEC 61508 and IEC 61511. As a result of SIL verification and SIS conceptual design, the shutdown system is composed of two gas detectors voted 1oo2, one programmable logic solver, and two shutdown valve voted 1oo2.

중수로 정지냉각계통의 냉각능력 분석 (Analysis of Cooldown Capability for the HWR Shutdown Cooling System)

  • 신정철
    • 에너지공학
    • /
    • 제20권4호
    • /
    • pp.259-266
    • /
    • 2011
  • 원자로 정지냉각계통은 원자로 정지 시 핵연료 잔열 제거를 위하여 냉각수가 충분히 공급하고 원자로기기들을 보호할 수 있는 냉각율을 유지할 수 있도록 설계되어야 한다. 경수로 정지냉각계통을 분석하기 위한 KDESCENT코드를 중수로 정지냉각계통에 적용하여 보았으며 기존의 중수로형 해석코드인 SOPHT, SDCS 코드 결과와 비교분석하였다. 정지냉각펌프 모드와 열수송펌프 모드에서 정상냉각 운전상태는 계통의 설계 요건을 만족시켰으며 정지냉각 열교환기를 열제거원으로 사용하였을 때 냉각률은 설계요건에서 규정하고 있는 제한치인 $2.8^{\circ}C/min$ 이하의 값을 얻었다. 전반적인 냉각능력 분석 결과 월성 2, 3, 4호기 정지냉각계통은 핵연료로부터 핵분열 생성물의 방출을 충분히 제한하고 핵연료채널의 건전성을 유지시키기 위한 충분한 냉각을 핵연료에 제공하였다.

보일러 플랜트의 자동 Shutdown 시스템을 위한 지식표현 (Knowledge Representation for the Automatic Shutdown System in Boiler Plants)

  • 송한영;황규석
    • 한국안전학회지
    • /
    • 제11권3호
    • /
    • pp.143-153
    • /
    • 1996
  • Shutdown of boiler plants is a dynamic, complicated, and hazardous operation. Operational error is a major contributor to danserous situations during boiler plant shutdowns. It is important to develop an automatic system which synthesizes operating procedures to safely go from normal operation to complete shutdown. Knowledge representation for automatic shutdown of boiler plants makes use of the hierarchical, rule-based framework for heuristic knowledge, the semantic network, frame for process topology, and AI techniques such as rule matching, forward chaining, backward chaining, and searching. This knowledge representation and modeling account for the operational states, primitive operation devices, effects of their application, and planning methodology. Also, this is designed to automatically formulate subgoals, search for positive operation devices, formulate constraints, and synthesize shutdown procedures in boiler plants.

  • PDF

UHPLC 시스템 종료 및 재가동 시 가이드 (UHPLC System Shutdown and Reactivation Advice)

  • Mark Fever;Gemma Lo
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.8.1-8.3
    • /
    • 2024
  • Ultra-high performance liquid chromatography (UHPLC) systems are integral to modern analytical laboratories, necessitating careful maintenance and operation protocols to ensure optimal performance. This document provides comprehensive guidelines for the proper shutdown and reactivation of UHPLC systems to prevent damage and maintain operational efficiency. • Shutdown: Remove the column and replace it with a union to avoid blockages. Flush the system with a compatible solvent mix, clean mobile phase reservoirs to prevent microbial growth, flush the pump with storage solvent, and clean the autosampler, including the needle and injection port. • Reactivation: Inspect the system for wear or damage, gradually reintroduce mobile phases starting with a weak solvent, reinstall the column securely, and perform system checks on baseline stability, pressure consistency, and detector performance. By adhering to these guidelines, laboratories can ensure the longevity and reliability of their UHPLC systems, maintaining high analytical performance and minimizing downtime. These procedures help prevent common issues such as blockages, contamination, and component wear, thereby supporting efficient and accurate analytical operations.

  • PDF

Utilization of EPRI ChemWorks tools for PWR shutdown chemistry evolution modeling

  • Jinsoo Choi;Cho-Rong Kim;Yong-Sang Cho;Hyuk-chul Kwon;Kyu-Min Song
    • Nuclear Engineering and Technology
    • /
    • 제55권10호
    • /
    • pp.3543-3548
    • /
    • 2023
  • Shutdown chemistry evolution is performed in nuclear power plants at each refueling outage (RFO) to establish safe conditions to open system and minimize inventory of corrosion products in the reactor coolant system (RCS). After hydrogen peroxide is added to RCS during shutdown chemistry evolution, corrosion products are released and are removed by filters and ion exchange resins in the chemical volume control system (CVCS). Shutdown chemistry evolution including RCS clean-up time to remove released corrosion products impacts the critical path schedule during RFOs. The estimation of clean-up time prior to RFO can provide more reliable actions for RCS clean-up operations and transients to operators during shutdown chemistry. Electric Power Research Institute (EPRI) shutdown calculator (SDC) enables to provide clean-up time by Co-58 peak activity through operational data from nuclear power plants (NPPs). In this study, we have investigated the results of EPRI SDC by shutdown chemistry data of Co-58 activity using NPP data from previous cycles and modeled the estimated clean-up time by EPRI SDC using average Co-58 activity of the NPP. We selected two RFO data from the NPP to evaluate EPRI SDC results using the purification time to reach to 1.3 mCi/cc of Co-58 after hydrogen peroxide addition. Comparing two RFO data, the similar purification time between actual and computed data by EPRI SDC, 0.92 and 1.74 h respectively, was observed with the deviation of 3.7-7.2%. As the modeling the estimated clean-up time, we calculated average Co-58 peak concentration for normal cycles after cycle 10 and applied two-sigma (2σ, 95.4%) for predicted Co-58 peak concentration as upper and lower values compared to the average data. For the verification of modeling, shutdown chemistry data for RFO 17 was used. Predicted RCS clean-up time with lower and upper values was between 21.05 and 27.58 h, and clean-up time for RFO 17 was 24.75 h, within the predicted time band. Therefore, our calculated modeling band was validated. This approach can be identified that the advantage of the modeling for clean-up time with SDC is that the primary prediction of shutdown chemistry plans can be performed more reliably during shutdown chemistry. This research can contribute to improving the efficiency and safety of shutdown chemistry evolution in nuclear power plants.

Supercritical CO2-cooled fast reactor and cold shutdown system for ship propulsion

  • Kwangho Ju;Jaehyun Ryu;Yonghee Kim
    • Nuclear Engineering and Technology
    • /
    • 제56권3호
    • /
    • pp.1022-1028
    • /
    • 2024
  • A neutronics study of a supercritical CO2-cooled fast reactor core for nuclear propulsion has been performed in this work. The thermal power of the reactor core is 30 MWth and a ceramic UO2 fuel can be used to achieve a 20-year lifetime without refueling. In order to make a compact core with inherent safety features, the drum-type reactivity control system and folding-type shutdown system are adopted. In addition, we suggest a cold shutdown system using gadolinium as a spectral shift absorber (SSA) against flooding. Although there is a penalty of U-235 enrichment for the core embedded with the cold shutdown system, it effectively mitigates the increment of reactivity at the flooding of seawater. In this study, the neutronics analyses have been performed by using the continuous energy Monte Carlo Serpent 2 code with the evaluated nuclear data file ENDF/B-VII.1 Library. The supercritical CO2-cooled fast reactor core is characterized in view of important safety parameters such as the reactivity worth of reactivity control systems, fuel temperature coefficient (FTC), coolant temperature coefficient (CTC), and coolant temperature-density coefficient (CTDC). We can say that the suggested core has inherent safety features and enough flexibility for load-following operation.

The aerostatic response and stability performance of a wind turbine tower-blade coupled system considering blade shutdown position

  • Ke, S.T.;Xu, L.;Ge, Y.J.
    • Wind and Structures
    • /
    • 제25권6호
    • /
    • pp.507-535
    • /
    • 2017
  • In the strong wind shutdown state, the blade position significantly affects the streaming behavior and stability performance of wind turbine towers. By selecting the 3M horizontal axis wind turbine independently developed by Nanjing University of Aeronautics and Astronautics as the research object, the CFD method was adopted to simulate the flow field of the tower-blade system at eight shutdown positions within a single rotation period of blades. The effectiveness of the simulation method was validated by comparing the simulation results with standard curves. In addition, the dynamic property, aerostatic response, buckling stability and ultimate bearing capacity of the wind turbine system at different shutdown positions were calculated by using the finite element method. On this basis, the influence regularity of blade shutdown position on the wind-induced response and stability performance of wind turbine systems was derived, with the most unfavorable working conditions of wind-induced buckling failure of this type of wind turbines concluded. The research results implied that within a rotation period of the wind turbine blade, when the blade completely overlaps the tower (Working condition 1), the aerodynamic performance of the system is the poorest while the aerostatic response is relatively small. Since the influence of the structure's geometrical nonlinearity on the system wind-induced response is small, the maximum displacement only has a discrepancy of 0.04. With the blade rotating clockwise, its wind-induced stability performance presents a variation tendency of first-increase-then-decrease. Under Working condition 3, the critical instability wind speed reaches its maximum value, while the critical instability wind speed under Working condition 6 is the smallest. At the same time, the coupling effect between tower and blade leads to a reverse effect which can significantly improve the ultimate bearing capacity of the system. With the reduction of the area of tower shielded by blades, this reverse effect becomes more obvious.