• Title/Summary/Keyword: Switching power

Search Result 4,310, Processing Time 0.025 seconds

Operating characteristics analysis of 3-phase voltage disturbance generator for the test of custom power devices (전력품질 개선장치의 성능시험을 위한 3상 전압변동 발생기의 동작특성 분석)

  • Park, S.D.;Nho, E.C.;Kim, I.D.;Chun, T.W.;Kim, H.G.
    • Proceedings of the KIEE Conference
    • /
    • 2006.04b
    • /
    • pp.244-246
    • /
    • 2006
  • This paper deals with an analysis of SCR thyristor switching pattern for a power quality disturbance generator with phase jump function. The proposed generator can be applied to the performance test of custom power devices. Voltage sag, swell, outage, unbalance and phase jump after outage are provided by the generator. The phase jump operating principle of the generator is described and analysed. Especially, a proper switching of the SCR thyristors for the proposed generator is important to guarantee the system reliability. Therefore the switching patterns for the thyristors in each made were analysed.

  • PDF

A Novel Auxiliary Resonant Commutated Pole Inverter Topology with Zero Current Turn-off for High Power Applications (대용량에 적합한 영전류 턴-오프 특성을 가진 새로운 공진 폴 인버터)

  • 김민홍;서범석;현동석
    • Proceedings of the KIPE Conference
    • /
    • 1996.06a
    • /
    • pp.39-42
    • /
    • 1996
  • This paper proposes a novel Auxiliary Resonant Commutated Pole Inverter (ARCPI) topology. The conventional ARCPIs make the hard switching at turn-off likewise the conventional PWM inverters. Therefore, turn-off switching losses may be so serious and can be so much considerable in high power level. The proposed ARCPI can solve this problem with high frequency transformers, switches, and capacitors. All the switches in the expanded auxiliary circuit achieves the soft switching and operates only during the commutating intervals. The characteristics and the analysis for each operation mode are described in detail and the validity is verified by the simulations and the experimental results.

  • PDF

A Study on about Implementation to Induction Cooker that load Turbo Inverter algorithm

  • Lee Min-Ki;Koh Kang-Hoon;Kwon Soon-Kurl;Lee Hyun-Woo;nakaoka M.
    • Proceedings of the KIPE Conference
    • /
    • 2001.10a
    • /
    • pp.136-139
    • /
    • 2001
  • The voltage resonating inverter has a defect in the switching element that works at 5 or 6 times higher than input voltage. Especially, it is very difficult to choose very high switching device for the 220[V]commercial voltage. In this paper, it is proposed the optimum method to realize the turbo 2000[W] power for induction cooker that is employed the 900[V] IGBT with decreasing operating voltage of the switching component by making the 220[V], 1500[W] inverter through the clamp mode voltage resonating inverter.

  • PDF

Design and Fabrication of Heater-triggered Switching System for the Charging of Bi-2223 Pancake Load (Bi-2223 팬케익부하 충전용 히터-트리거 스위칭 장치의 설계 및 제작)

  • 김영식;윤용수;배덕권;안민철;임대준;김호민;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.43-48
    • /
    • 2004
  • This paper deals with design and fabrication of heater-triggered switching system for the high-Tc superconducting (HTS) power supply with series-connected double-pancake load. Amongst all components, heater triggering is the most important element for the performance of HTS power supply. To fabricate the optimal heater-triggered system, its characteristics have been analysed through the simulation and expriment. The thermal analysis of switching parts of the Bi-2223 solenoid according to the heater input was carried out. Based upon the analysis, 8A electromagnet current and 1.5A DC Heater current were optimally derived, and 8s and 20s for the pumping period were selected in this experiment. In the experiment. the maximum pumping current reached about 24A with Bi-2223 pancake load of 6mH.

Dynamic Characteristic Analysis of Single Phase SRM (단상 SRM의 구동 특성 해석)

  • Lee, Jong-Han;Lee, Eun-Woong;Jo, Yeon-Chan
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.59-61
    • /
    • 2006
  • The single phase switched reluctance motor(SRM) is simpler in control circuit because the number of switching devices is fewer than the poly phase SRM. The energy density per unit volume is very big because all stator poles are excited simultaneously by a single switching power source. But it must be provided a starting device on account of not being generated the starting torque at specific rotor positions. And also it has some demerits that have a torque ripple, noise and vibration because of being excited by switching pulse power source. Therefore, to make up for these demerits, it is realized many studies for the structure design used by computer and the operating methods by power electronics technique. In this paper, we'll present the comparison of the single phase SRM with the various rotor pole face types, as like stepped rotor pole face type and general rotor pole face type. For the torque characteristics analysis.

  • PDF

Boost-Half Bridge Single Power Stage Configured PWM DC-DC Converter for Residential PEFC Stack Interface.

  • Khairy, Fathy;Choi, Kwang-Ju;Lee, Hyun-Woo;Mutsuo, Nakaoka
    • Proceedings of the KIEE Conference
    • /
    • 2006.10d
    • /
    • pp.132-134
    • /
    • 2006
  • This paper presents the design and implementation of 1 kW prototype DC-DC power converter with bridge voltage-doubler suitable for small scale PEM fuel cell system and its associated control scheme. The operation principle of this converter is described using some operating waveforms and the switching mode equivalent circuits based on simulation results and a detailed circuit operation analysis and soft-switching conditions.

  • PDF

The improvement of sterilization effective using resonance inverter Power conversion device (공진용 인버터 전력 변환 장치를 이용한 플라즈마 살균효과 개선)

  • Kim, J.Y.;Kim, Y.M.;Kwon, S.K.;Lee, H.W.;Suh, K.Y.
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.266-269
    • /
    • 2003
  • A sterilizer equipment by using electrical energy has merits that no process of chemical and no second environmental pollution. Also, the power conversion circuit for sterilizer equipment has merits that are reducing switching loss for soft switching topology by using zero current and zero voltage switching, and miniaturizing size of equipment. Thus, it is expected that the cost of sterilization process, when quality of the device is measured by power consumption, will be reduced. Therefore, the purpose of this research is to solve the sterilization problems of existing powder with plasma sterilization device, to find more economical and effective way, and to suggest more improved sterilizer.

  • PDF

A Study for the Switching Method of the Temperature Control System with the Resonance Feature (공진특성을 가지는 온도제어시스템의 스위칭 기법 연구)

  • Park, Hwal-Gon;Park, Cheol-U;Choe, Yeon-Ho;Gu, Bon-Ho;Gwon, U-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.87-90
    • /
    • 2003
  • There are generally two temperature control methods using ac voltage regulators - the phase control method and the on-off control method. The phase control method uses thyristor's angles of extinction for the output power regulation and the on-off control method uses the control of on and off times for the output power regulation. Both of methods have the problems that are the unbalance of the three phase and surge current caused system's destruction. The main object of this study proposes a solution of problems of surge currents and unbalance of three phase when thyristor voltage regulator is switching. To solve the problem, It is proposes that the solution of surge currents is using a tap transformer and an additional switch with adjustable resistance and applies zero crossing of switching voltage of two input line to power load. This method is discuss and verified by computer simulations and experiments.

  • PDF

A Signal Anti-reduction System in PLC using Ferrite Core and Switching Amplifier (페라이트 코어와 스위칭 증폭기를 이용한 PLC 신호 감쇠 저하 시스템)

  • 고종선;김영일;김규겸
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.474-480
    • /
    • 2001
  • In this paper a low signal reduction communication system that does not use the communication line but power line is presented It will be very useful for an information-oriented society with tele-metering and home automation. The conventional system has a difficulty in transmitting information due to decreasing communication voltage. The proposed system employs a special type switching amplifier system which has a low inner resistance and uses high efficient ferrite core in coupling circuit. This new system is proposed to reduce the loss of conductor load and coupling circuit in a PLC system.

  • PDF

A New Zero Voltage Transition Bridgeless PFC with Reduced Conduction Losses

  • Mahdavi, Mohammad;Farzanehfard, Hosein
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.708-717
    • /
    • 2009
  • In this paper a new zero voltage transition PWM bridgeless PFC is introduced. The auxiliary circuit provides soft switching condition for all semiconductor devices. Also, in the resonant path of the auxiliary circuit, only two semiconductor devices exist. Therefore the resonant conduction losses are low. Furthermore, the auxiliary circuit semiconductor elements consist of only one diode and one switch. The proposed auxiliary circuit is applied to a bridgeless PFC converter to further reduce conduction and switching losses. In this paper, the operating modes of this converter are explained and the resulting ideal and simulation waveforms are shown. The presented experimental results justify the theoretical analysis.