• Title/Summary/Keyword: Switch-control

Search Result 1,253, Processing Time 0.03 seconds

Study on Transient Improvement through Governor Control under Asynchronous Transition of CTTS (CTTS의 비동기 절체 시 조속기 제어를 통한 과도 개선에 관한 연구)

  • Kang, Byoung-Wook;Chai, Hui-Seok;Han, Woon-Ki;Lim, Hyun-Sung;Kwon, Seung-Ok;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.11
    • /
    • pp.47-52
    • /
    • 2015
  • This paper derives the problems that occur when asynchronous transfer in case of phase, frequency, voltage between the emergency generator and the grid and proposed the countermeasure to solve this problem when the transfer switch replace ATS(Automatic Transfer Switch) with CTTS(Closed Transition Transfer Switch) for the non-interrupting switching. In order to simulate above cases, modelling was used the transient analysis program PSCAD/EMTDC. By using this, the customer installed emergency generator and the grid was implemented. We compared three cases of asynchronous transition based on the basic case and proposed improvement by controlling the governor of emergency generator.

Resonant Capacitor On/Off Control of Half-Bridge LLC Converter for High Efficiency Server Power Supply (고효율 서버용 전원 장치를 위한 하프-브리지 LLC 컨버터의 공진 커패시터 온-오프 제어)

  • Lee, Jae-Bum;Baek, Jae-Il;Youn, Han-Shin;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.285-286
    • /
    • 2015
  • In this letter, a simple control method of the HB LLC converter with one additional switch and capacitor in the primary side is proposed for wide-input-voltage applications with the hold-up time conditions. At nominal input, since the proposed method enables the HB LLC converter to operate with large transformer magnetizing inductance, it can reduce the conduction and switch turn-off losses in the primary side, which makes a high efficiency. On the other hand, during the hold-up time, since the proposed method increases the resonant capacitance by turning on one additional switch, the HB LLC converter can obtain high voltage gain.

  • PDF

Fault Tolerant System for Open Switch Fault of BLDC Motor Drive (BLDC 전동기 드라이브의 개방된 스위치 고장에 대한 고장 허용 시스템)

  • Park, Byoung-Gun;Kim, Tae-Sung;Ryu, Ji-Su;Lee, Byoung-Kuk;Hyun, Dong-Seok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.11 no.2
    • /
    • pp.164-171
    • /
    • 2006
  • In this paper, the fault tolerant system for BLDC motor has been proposed to maintain control performance under an open switch fault of inverter. The fault identification is proposed to two methods, which are using the difference between reference and actual current, and adding voltage sensors across lower legs of inverter. The reconfiguration scheme is achieved by the four-switch topology connecting a faulty leg to the middle point of DC-link using bidirectional switches. The proposed fault tolerant system quickly recovers control performance by short fault detecting time and reconfiguration of system topology. Therefore, continuous free operation of the BLDC motor drive system after faults is available. The superior performance of the proposed fault tolerant system is proved by simulation.

Case Study of Intermittent Poor Acceleration Fault Diagnosis by Brake Switch Fault (브레이크 스위치 결함에 의한 간헐적인 가속불량 현상의 고장진단 사례연구)

  • Kim, Sung Mo;Jo, Haeng Deug
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.2
    • /
    • pp.203-210
    • /
    • 2015
  • This paper investigates the failure of a car with a 2.5-liter CRDi engine of the Hyundai Company. The failure is caused by intermittent poor acceleration while driving. To analyze the cause, we investigated the air intake volume, the fuel injection, and the air-fuel ratio, which were determined to be normal. The brake switch signal error was discovered while analyzing the function that limits the output of the engine. While investigating the cause, we discovered the corrosion of the pins on the connector of the brake switch. We determined that it was generated by soapy water flowing in the solar film. Therefore, the cause of the failure was the brake switch signal errors. Additionally, we determined that ECM was the normal fail-safe mode that implemented the override device for safety during normal acceleration. Based on these results, further solar film experiments must be conducted to fully elucidate the causes.

Power Monitoring System of Smart Homes using Embedded System (임베디드 시스템을 이용한 스마트 홈 전력 모니터링 시스템)

  • Kim, Woo-Sung;Park, Kyeong-Jin;Park, Sang-Cho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.8
    • /
    • pp.5201-5206
    • /
    • 2014
  • A 'Light switch remote control' was made with an android smartphone and a smart light switch, which can use wireless communication on this paper. A smart light switch uses an embedded board and Bluetooth communication to receive and transmit data, and it receives and sends data again with a smartphone and wireless communication. This study used the flexibility of sensors that could be added later to utilize the embedded board as a gateway. This skill is being serviced now in a new apartment and building. On the other hand, existing households that do not support this skill can use it if they change only the switch. In conclusion, this system ensured user convenience and flexibility of system.

A study on Non-contacted Transmitter Switch for Vehicle (비 접촉식 차량용 Transmitter Switch에 관한 연구)

  • Ahn, Jong-Young;Kim, Young-Sub;Kim, Sung-Su;Hur, Kang-In
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.10 no.5
    • /
    • pp.245-249
    • /
    • 2010
  • Now normally using a contact method of vehicle Inhibitor Switch that is use direct voltage level signal. This method is good solution for signal deliverly. but The contacted method have a short lifetime because of deterioration of contact surface. so we suggest to non-contacted method using magnetic sensor. The magnetic sensor is used to non-contacted method that is solution for problem of contacted method. In this paper using that of magnetic sensor feature, so we applied to Vehicle Transmitter switch that of non-contacting method. Sensor voltage outputs have variable electric potential that normally 0 mV to 150 mV, and it is depend on Switch Angle. we used two differential sin wave for switching of 5 state signal.

Implementation of Quad-Band p-HEMT SP6T Switch for Handset Applications (개인 휴대통신용 4중대역 p-HEMT SR6T 스위치 구현)

  • Shin, One-Chul;Jeong, In-Ho
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.48 no.1
    • /
    • pp.97-101
    • /
    • 2011
  • Quad band p-HEMT SP6T switch for handset applications was developed. To achieve the low insertion loss and high isolation, trade-off between "On" state and "Off" state was considered by optimization of unit cell. Especially, in case isolation between transmit port and receive port, it was achieved by large capacitors and miniaturization of chip size was achieved by common voltage control and ground using back via process. Designed SP6T switch has size of $950um{\times}100um$ and take into consideration the gate recess error, excellent loss and isolation was confirmed in operating frequency.

Space-vector PWM Techniques for a Two-Phase Permanent Magnet Synchronous Motor Considering a Reduction in Switching Losses

  • Lin, Hai;Zhao, Fei;Kwon, Byung-il
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.3
    • /
    • pp.905-915
    • /
    • 2015
  • Two PWM techniques using space vector pulse-width modulation (SVPWM) are proposed for a two-phase permanent magnet synchronous motor (PMSM) driven by a two-phase eight-switch inverter. A two-phase motor with two symmetric stator windings is usually driven by a two-phase four-, six-, or eight-switch inverter. Compared with a four- and six-switch inverter, a two-phase eight-switch inverter can achieve larger power output. For two-phase motor drives, the SVPWM technique achieves more efficient DC bus voltage utilization and less harmonic distortion of the output voltage. For a two-phase PMSM fed by a two-phase eight-switch inverter under a normal SVPWM scheme, each of the eight PWM trigger signals for the inverter have to be changed twice in a cycle, causing a higher PWM frequency. Based on the normal SVPWM scheme, two effective SVPWM schemes are investigated in order to reduce the PWM frequency by rearranging four comparison values, while achieving the same function as the normal PWM scheme. A detailed explanation of the normal and two proposed SVPWM schemes is illustrated in the paper. The experimental results demonstrate that the proposed schemes achieve a better steady performance with lower switching losses compared with the normal scheme.

A Design of Proposed ATM Switch using PRRA (PRRA로 제안된 ATM Switch 설계)

  • Seo, In-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.7 no.2
    • /
    • pp.115-123
    • /
    • 2002
  • This thesis proposes a new type of Input-Output Buffered ATM Switch which employs an arbiter and its performance under different traffic conditions studied. The proposed switch is designed with a view to exploit the architecture and other characteristics of the arbiter. The primary aim of the proposed switch is the elimination, or at least, the reduction of HOL blocking phenomenon which occurs in the simple input buffered switch. Several HOL arbitration algorithms have been proposed for this purpose in the literature. The proposed switch attempts to reduce the HOL blocking as it uses the arbiter and the buffer at the output port in an effective manner. The arbiter is designed to work with Three Phase Algorithm which is one of the many well known HOL arbitration algorithms. The Proposed switch acquires control over priority transmission through the REQ signal. As the signals are transmitted to the arbiter, the latter controls the one which is sent by the input buffer. Computer simulation results have been provided to demonstrate the effectiveness of the Proposed switch under uniform traffic conditions.

  • PDF

A Design of ATM Switch for High Speed Network (고속 네트워크를 위한 ATM Switch 설계)

  • Seok, Seo-In;Kuk, Cho-Sung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.2
    • /
    • pp.97-105
    • /
    • 2003
  • This thesis proposes a new type of Input-Output Buffered ATM Switch which employs an arbiter and its performance under different traffic conditions studied. The proposed switch is designed with a view to exploit the architecture and other characteristics of the arbiter The primary aim of the proposed switch is the elimination, or at least, the reduction of HOL blocking phenomenon which occurs in the simple input buffered switch. Several HOL arbitration algorithms have been proposed for this purpose in the literature. The Proposed switch attempts to reduce the HOL blocking as it uses the arbiter and the buffer at the output Port in an effective manner. The arbiter is designed to work with Three Phase Algorithm which is one of the many well known HOL arbitration algorithms . The proposed switch acquires control over priority transmission through the REd signal. As the signals are transmitted to the arbiter, the latter controls the one which is sent by the input buffer. Computer simulation results have been provided to demonstrate the effectiveness of the proposed switch under non-uniform random traffic conditions.

  • PDF