• 제목/요약/키워드: Sustain electrode

검색결과 80건 처리시간 0.029초

Reciprocal Sustain and Auxiliary Pulse Waveforms Applied to an AC PDP with an Auxiliary Electrode

  • Choi, Kyung-Cheol;Lee, Sung-Min;Choi, Chung-Sock;Jang, Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2008년도 International Meeting on Information Display
    • /
    • pp.1543-1546
    • /
    • 2008
  • Modified pulse waveforms were applied to an AC plasma display panel with an auxiliary electrode in order to improve the operation voltage margin. Reciprocal sustain pulse waveforms and modified auxiliary pulse waveforms were applied to the sustain and auxiliary electrode, respectively. During the sustain period, the influence of the address electrode on the luminous efficacy of long-coplanar gap discharges was mitigated by application of reciprocal sustain pulse waveforms. Modified auxiliary pulse waveforms maintained the high efficacy obtained from the AC PDP with an auxiliary electrode. The proposed reciprocal sustain and modified auxiliary pulses waveforms can induce stable discharges in long-coplanar gap discharges and can control wall charges with a wider auxiliary pulse voltage margin, thereby enhancing the luminous efficacy of the AC PDP with an auxiliary electrode.

  • PDF

AC PDP의 장방전 구조의 구동을 위한 새로운 셀렉티브 리셋파형 (New Selective Reset Waveform for a Large-Sustain-Gap Structure in AC PDPs)

  • 송태용;김동훈;전원재;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1391-1392
    • /
    • 2007
  • A selective reset waveform which can improve the dark room contrast ratio in a large sustain gap structure is suggested in this paper. When conventional selective reset discharge is performed, frequent unexpected misfiring happens because of high Vxb and much quantity of negative wall charge formed on Y electrode during final sustain period. The misfiring between sustain electrode and address electrode can be removed by lowering Vxb value and the misfiring between address electrode and scan electrode can be prevented by applying last sustain pulse of 40us and rectangular pulse of Vscan on Y electrode. When the selective reset waveform has one time reset per 8 subfields, black luminance of 1.55 cd/m2 can be obtained without any misfiring.

  • PDF

AC PDP의 새로운 고효율 전극구조 (New Sustain Electrode Structure for High Luminous Efficiency in AC PDP)

  • 박차수;최준영;최윤창;허정은;이영권;박정후
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권9호
    • /
    • pp.475-480
    • /
    • 2004
  • One of the most important issues in AC PDP is the improvement of luminous efficiency. One possible method is to develop new sustain electrode shape showing high luminous efficiency. In this study, a new electrode shapehas a bridge is proposed in order to solve this problem. The experimental results show that the test panel with the suggested new electrode shape shows high luminance efficiency by 35.35% and low sustain voltage by 17V compared with the conventional structure.

Variation of the Discharge Characteristics in single-sustainer Driving of an AC PDP

  • Kim, Joong-Kyun;Jung, Hae-Yoon
    • Journal of Information Display
    • /
    • 제11권4호
    • /
    • pp.154-159
    • /
    • 2010
  • Single-sustainer driving is an AC PDP driving scheme to reduce the circuitry by maintaining the sustain electrode at ground level. To date, however, the research on the discharge characteristics in such driving scheme is insufficient. In this study, the panel performance and discharge characteristics of the single-sustainer driving scheme were observed while varying the address electrode condition. In single-sustainer driving, the address electrode is strongly involved in the sustain discharge when the former is maintained at ground level, and the dependence of the luminous efficacy on the sustain voltage is different from that in the conventional driving scheme. The dependence of the luminous efficacy on the sustain voltage appeared similar, however, to that in the conventional driving scheme when the address electrode was floated in single-sustainer driving. In the investigation of the temporal evolution of the sustain discharge using an IICCD camera, it was found that the sustain discharge in single-sustainer driving with a floating address electrode is similar to that in the conventional driving scheme, and the strong plasma formation region was located in the vicinity of the MgO surface, which seems to be related to the lifetime of a PDP with single-sustainer driving. In the investigation of the operation characteristics, the PDP that was operated with a floated address electrode showed a narrower dynamic operation margin, but a longer lifetime was expected.

The 2-dimensional Discharge Cell Simulation for the Analysis of the Peset and Addressing of an Alternating Current Plasma Display Panel

  • Kim, Joong-Kyun;Chung, Woo-Jun;Seo, Jeong-Hyun;Whang, Ki-Woong
    • Journal of Information Display
    • /
    • 제2권1호
    • /
    • pp.24-33
    • /
    • 2001
  • The characteristics of the reset and the address discharges of an alternating current Plasma Display Panel (ac PDP) were studied using 2-dimensional numerical discharge cell simulation. We investigated the wall charge variations during the reset discharge adopting ramping reset pulse and the subsequent addressing discharge. The roles of the ramping reset scheme can be divided into two stages, each electrode gathers wall charges during ramping-up of the initial stage and the built-up wall charges are lost during ramping-down of the later stage. Address discharge does not only change the wall charge distributions on the address and the scan electrodes but also on the sustain electrode. The increase in the wall charges on the sustain electrode was observed with the variation of the applied voltage to the sustain electrode during the address period. The increase of the applied voltage to the sustain electrode during the address period is expected to induce the decrease of the sustain voltage during the display period.

  • PDF

Experimental Observation of Temporal Dark Image Sticking in AC PDP with Face-to-Face Sustain Electrode Structure

  • Kim, Jae-Hyun;Park, Choon-Sang;Kim, Bo-Sung;Park, Ki-Hyung;Tae, Heung-Sik
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2007년도 7th International Meeting on Information Display 제7권1호
    • /
    • pp.617-620
    • /
    • 2007
  • The temporal dark image sticking phenomena for both the face-to-face and coplanar sustain electrode structures were compared. For both structures, the temporal dark image sticking phenomena were examined by measuring the difference in the IR emission, display luminance, perceived luminance, and temperature between the image sticking and the no image sticking cells. For the face-to-face structure, the 10-min sustain discharge causes a small increment of the panel temperature thanks to the ITO-less electrode structure, thereby resulting in mitigating the temporal dark image sticking phenomenon.

  • PDF

Characteristics of Sustain Discharges in AC PDP with various Coplanar-Gaps and Auxiliary Electrode

  • Lee, Kyo-Sung;Shin, Nam-Hoon;Shin, Bhum-Jae;Choi, Kyung-Cheol;Jang, Sang-Hun;Park, Hyoung-Bin;Lee, Seong-Eui
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.175-178
    • /
    • 2005
  • The spatio-temporal behaviors of Infra Red(IR) emission images of the sustain discharges were observed in AC PDP with various coplanar-gaps and auxiliary electrode. When the height of barrier rib was fixed, IR intensity of the sustain discharges in AC PDP did not increase with increase of coplanar-gap. The IR efficiency of sustain discharges showed the similar behavior with the IR intensity. The IR intensity had its maixmum value when the coplanar-gap was $200\;{\mu}m$ and the height of barrier rib was $150\;{\mu}m$. It was also found that the auxiliary electrode in the front plate enhanced IR emission during sustain discharge when the pulse was applied to the auxiliary electrode.

  • PDF

Effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap

  • Park, Sang-Dae;Lee, Seung-Hun;Shin, Nam-Hoon;Lee, Kyo-Sung;Park, Sung-Yun;Kim, Sang-Ho;Shin, Bhum-Jae;Choi, Kyung-Cheol
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2004년도 Asia Display / IMID 04
    • /
    • pp.109-112
    • /
    • 2004
  • The effect of auxiliary electrode on the discharge characteristics in AC PDP with long sustain-gap was investigated. The auxiliary electrode was placed between scan and common electrode. When the pulse was applied to the auxiliary electrode during sustain period, the luminance of Ne + 13%Xe gas-mixture discharge increased and the discharge current decreased. The auxiliary pulse plays a role of improving electron excitation efficiency. When the auxiliary pulse was applied during address period, the address discharge time lag of Ne + 13%Xe gas-mixture could be reduced remarkably.

  • PDF

42″ AC-PDP의 방사특성에 대한 연구 (Investigation on Radiation Characteristics of 42″ AC-PDP)

  • 임헌용;김민석;박동욱;이정해
    • 한국전자파학회논문지
    • /
    • 제15권9호
    • /
    • pp.841-847
    • /
    • 2004
  • EMI emission characteristics of 42" AC-PDP panel are investigated in this paper. First, EMI emission source was modeled the scan electrode and the sustain electrode to a simple electric and magnetic dipole type radiator. Second, EMI emission source was modeled as reconfigured the scan electrode and the sustain electrode. The primary source of EMI emission was investigated using FEM calculation of the wave impedance and 3 dB beam width. The third. the EMI emission level was estimated using the measured sustain electrode current. Also, EMI emission level of 42" AC-PDP was measured. The results show that the calculated EMI emission level from the simple electric dipole model was shown to agree with that from the corresponding FEM simulation.

교류형 플라즈마 디스플레이의 리셋구간 단축을 위한 새로운 리셋 파형 (A New Reset Waveform for Reducing Reset Period in AC-PDP)

  • 김근수;최훈영;김성익;김준형;정해영;민병국;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 C
    • /
    • pp.1636-1639
    • /
    • 2002
  • We proposed the new reset waveform for reducing reset period. The square pulse is applied to the address electrode when the ramp pulse increases before a discharge occurs between sustain electrodes. If the discharge occurs between address electrode and X electrode, the wall charge is reversely accumulated between sustain electrodes compared with the applying voltage before the discharge occurs between sustain electrodes. So the next discharge more weakly occurs between sustain electrodes. If the more weak discharge is obtained, it can make the low background luminance and the high contrast ratio and reduce ramp up time in the ramp reset waveform.

  • PDF