• Title/Summary/Keyword: Surgical glove

Search Result 19, Processing Time 0.033 seconds

Incidence and Risk Factors for Surgical Glove Perforation (수술용 장갑의 천공률에 대한 연구)

  • Yoo, Seon Ju;Lim, Young Shin;Kim, Myung Suk
    • Journal of Korean Clinical Nursing Research
    • /
    • v.16 no.3
    • /
    • pp.63-71
    • /
    • 2010
  • Purpose: This study was conducted to evaluate the incidence and risk factors for surgical glove perforation during operation. Methods: During the month of december 2008, a total of 1,400 pairs of surgical gloves used in major operations was collected in a tertiary hospital. All gloves were examined immediately after operation using the standardized water-leak method to detect any perforation. Incidence of the glove perforation was counted according to the type of operation, operation time, the number of involved personnel, perforation sites, and the manufacturing companies. Results: Out of 2,800 gloves examined, 312 perforations were detected comprising 11.1% of samples. In terms of the type of operation, the perforation incidence varied from 5% to 20%, and the perforation rates in CS (20%) and NS (18%) (p<.001) were significantly higher than those in other departments. The 1st assistant or scrub nurse got glove perforation more frequently than the 2nd assistant or operator (p<.001). Longer operation time was associated with higher incidence of perforation evidently (p<.001). In terms of the sites, the thumb and index finger were more frequently perforated than other sites (4.1% and 3.4% respectively) without any differences between left and right side. Conclusion: Risk factors for glove perforation including the department of operation, operation time, participating personnel, and location of perforation should be taken into account to improve surgical safety.

The Effect of Glove Changing during Surgery for Colon Cancer (대장암수술 시 장갑교환의 효과)

  • Park, Eunji;Ham, Eunmi
    • Korean Journal of Adult Nursing
    • /
    • v.26 no.1
    • /
    • pp.98-106
    • /
    • 2014
  • Purpose: The purpose of this study was to explore the effect of glove changing during surgery for colon cancer on reducing the degree of contamination of surgical gloves. Methods: The randomized posttest control group design was used. Total 72 surgeries of colon cancer in the K University Hospital in Seoul performed by the team of A-Surgeon and B-Scrub nurse were randomly assigned to one of the three groups. Glove changing with single-gloved state was implemented in the Experimental Group I and outer glove changing with double-gloved state was executed in the Experimental Group II. Single-gloved state was carried in the Control Group. Following the surgical procedure, specimens for bacterial culture were collected the from scrub nurse's gloves to compare the degree of contamination among the three groups. Data were analyzed with One-way ANOVA and the Scheff$\acute{e}$'s multiple comparison test. Results: The degrees of contamination of the Experimental Group I and II were significantly lower than that of the Control Group. There was no significant difference between Experimental Group I and II. Conclusion: Glove changing during surgery with either single or double-gloved state is effective in reducing the degree of contamination of surgical gloves, therefore these methods should be utilized in clinical practice.

Role of the Surgical Glove in Modified Vacuum-Assisted Wound Healing

  • Hemmanur, Shankar Ram;Siddha, Loka Vijayan
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.630-632
    • /
    • 2013
  • Vacuum-assisted wound healing has been proven to be more efficacious than conventional dressings. Vacuum dressing has been frequently modified given the restrictions in resources available. Here we present a modified method of vacuum dressing by using surgical or gynaecological gloves for lower and upper limb wounds. Vacuum dressing was applied with parts of a surgical or gynaecological glove and Opsite with T-tailing of the suction outlet. Vacuum-assisted wound healing using the surgical gloves showed relatively good wound healing in the amputation stump, finger, arm, and leg in the cases studied.

Effectiveness of Silk-glove Test in the Contralateral Exploration of Inguinal Hernia in Children (소아 서혜탈장의 진단시 Silk-glove test의 유용성에 대한 연구)

  • Koo, Bon-Yong;Kim, Jae-Chun;Jeong, Yeon-Jun
    • Advances in pediatric surgery
    • /
    • v.12 no.1
    • /
    • pp.11-16
    • /
    • 2006
  • Inguinal hernia is one of the most common surgical diseases in pediatric patients. But the management of the side opposite the clinically apparent inguinal hernia, the "silent side" is controversial. Four hundred fifty-eight cases of pediatric inguinal hernias, operated by one pediatric surgeon at the Divisionof Pediatric Surgery, Department of Surgery, Chonbuk National University Hospital from January 1998 to December 2002, were reviewed retrospectively to determine the characteristics and significances of the silk-glove test on the side opposite the clinically apparent inguinal hernia. Males were preponderant as 2.8:1. Allhernias were of the indirect type and were repaired by high ligation of the sac. There were 238 (52.0 %) right sided hernias, 160 (35.0 %) were on the left and 60 (13.0%) were bilateral. The number of patients with a positive silk-glove sign on the contralateral side was 158(39.7 %), and 133 of these had a contralateral patent processus vaginalis. Positive predictive value of Silk-glove test was 84.2 % (133/158). The silk-glove test is a simple, safe, and relatively accurate method for contralateral exploration in the unilateral inguinal hernias in children.

  • PDF

A Study on Actual Conditions of Glove Size Standards - Focused on KS and ISO Sizing System- (장갑의 치수규격 실태에 관한 연구 - KS와 ISO 치수체계를 중심으로 -)

  • 김은경;최혜선
    • Journal of the Korean Society of Costume
    • /
    • v.54 no.6
    • /
    • pp.77-90
    • /
    • 2004
  • The purpose of this study was to provide basic information requisite in the new sizing system for gloves. KS glove standards' size dimensions, size designation and labeling systems were analyzed. Also, KS glove standards' control sizes were compared to the anthropometric data of 824 Korean adults taken in the previous study. As well, the ISO hand size system was also compared to the anthropometric data of the previous study according to frequency tables of hand length and hand circumference. The size dimensions showed differences among KS standards and there was no size designation and labeling systems existed in KS standards. Among KS glove size systems, protective rubber gloves for radioactive contamination and surgical rubber gloves' size which followed ISO system were accurately indicate the hand size of the person a glove is intended to fit. ISO glove sizing system comprised the control dimensions of hand length and hand circumference. The coverage of ISO size A was 84.8% which was highest among ISO size A. B, C. And in hand circumference 178, 191, 203, 216mm showed the frequencies above 3% and in hand length 167, 175. 183, 191, 199mm showed the frequencies above 3%.

Sutureless Laparoscopic Ovariectomy in Small Dogs Using Two 3-mm Portal Sites

  • Hyeon-Han Ku;Ho Hyun Kwak;Jun-Hyung Kim;Kyung-Mee Park;Heung Myong Woo
    • Journal of Veterinary Clinics
    • /
    • v.39 no.6
    • /
    • pp.319-325
    • /
    • 2022
  • Two-port laparoscopic ovariectomy (Lap-OVE) has been performed in small dogs, using 3-mm and 5-mm portal sites, and is associated with reduced surgical stress and postoperative pain. However, extension of the incision is often needed to extract the ovaries. In this study, we aimed to minimize invasiveness by using smaller-sized cannulas as well as a novel technique for ovary extraction. Lap-OVE was performed on six, healthy female dogs (range, 3 to 7.2 kg) using two 3-mm midline portals. The middle finger of a size M nitrile glove was cut at its base and sterilized preoperatively. The ovary was suspended at the body wall using a 1-0 blue nylon needle, and the ovarian pedicle and ligaments were transected using a 3-mm bipolar forceps. To facilitate the glove passing through the 3.9-mm port, it was turned inside out to expose the smooth inner surface, before being inserted into the abdominal cavity with an applicator. Both ovaries were placed inside, and the mouth of the glove was exteriorized through the port with a laparoscopic grasping forceps. The ovaries were morcellated inside the glove, using Adison-Brown tissue forceps and iris scissors, which enabled safe extraction without incision enlargement. Median incision lengths were 4.3 mm (3.5-mm cranial cannula) and 4.8 mm (3.9-mm caudal cannula). An advantage of this procedure was that there was no need for skin sutures. In conclusion, using our novel technique, sutureless Lap-OVE was possible in small dogs using two 3-mm portal sites without additional incision.

Development and evaluation of modified lead gloves to reduce hand radiation dose during interventional radiological procedures

  • Hyun-Jun Park;Byungdu Jo;Seung-Jae Lee
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2781-2789
    • /
    • 2024
  • We developed lead gloves that minimize radiation dose to the operator's hands during interventional radiological procedures and that do not impede the operator's surgical capabilities. Existing lead gloves can protect the operator's hands by shielding radiation, but use of such gloves may impair preception sensitivity, resulting in a reduction in the operator's surgical ability. Accordingly, in this study, we developed modified lead gloves that can reduce radiation dose while maintaining operator sensitivity during procedures by modifying the operator's main surgical finger area in existing lead gloves. To evaluate the performance of developed modified lead gloves, radiation was applied in surgical conditions without gloves and with surgical gloves, lead gloves, and modified lead gloves. The radiation dose was evaluated for each condition. When the modified lead gloves were worn, the degree of shielding was similar to when conventional lead gloves were worn. Based on these results, if the operator wears modified lead gloves during interventional radiological procedures, they will protect the hands from radiation while maintaining physical sensitivity in the hands.

Measurement of Orbit using Standardized Processing of CT Scan

  • Kim, Yong Oock
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.7-12
    • /
    • 2014
  • Purpose Surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these surgeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable reationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. Method Author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Results The method was allowed to evaluate inter-dacryon distance, inter-centroid distance, movement of the medial orbital wall, movement of the lateral orbital wall, alteration of thickness of the lateral periorbital fat as indicator of movement of the orbital wall and orbit in the patient with congenital periorbital anomaly and postoperative periorbital surgery. The goal of surgical correction of various occular problems which do not have visual problem in plastic surgical area is to normalize the appearance of the face by restoring the normal position of orbit and eyeball. With development of surgical technique, the orbit can be restored exactly in trauma patient and can be moved totally in hypertelorism, as an example of congenital disease. All these sugeries are based on the hypothesis that the position of oclular glove moves in the plane in a quantitatively predictable relationship to osseous orbit movement. However, no studies have critically evaluated between the change of periorbital soft tissue and the outcome of the surgical correction, because there is no method of objective, quantitave evaluation of the periorbital soft tissue. In this report, author suggest the methodology for quantitative assessment of ocular and periocular fat changes using the manipulation of digital images of computed tomographic scan. Conclusion The method suggested is objective and accurate method in measurement of the orbital contents. It takes time and is not easy to do, however, this kind of measurement for fine structures will be more easily available in near future.

A Clinical Study on Relationship of Surgical Glove and Back Pain after Lumbar Puncture in Children (소아에서 요추천자 후 발생하는 요통과 수술용 장갑과의 관계에 대한 임상적 연구)

  • Han, Sung Ryoung;Choi, Wan Suk;Lee, Hae Jeong;Kim, Hyun Seok;Lee, Ju Suk;Cho, Kyung Lae
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.3
    • /
    • pp.310-314
    • /
    • 2005
  • Propose : In this study, we evaluated whether powder on surgical gloves is a cause of postpuncture backpain in children. Mothods : In 164 children with meningitis between July and September 1997, we did not remove powder from surgical gloves. However, in 149 children with menigitis between May and October 2001 the powder was removed from the surgical gloves. Results : Out of the 164 patients in 1997, 41 cases(25.00%) were found to have postdural puncture backpain. On the other hand, out of 149 patients in 2001, with whom we used gloves from which the powder was removed, we found only 8 patients(5.36%) with postdural puncture backpain. Conclusion : We conclude that the powder on surgical gloves is one of the main causes of postdural puncture backpain in children.

Simple Molding Method for Post-distant Flap Stated Finger by Using Surgical Rubber Gloves (원위피판술을 시행한 환자의 손가락에 수술용 고무장갑을 이용한 간단한 조형법)

  • Kim, Ho Kil;Choi, Hwan Jun;Kim, Mi Sun;Shin, Ho Sung;Tark, Min Sung
    • Archives of Plastic Surgery
    • /
    • v.33 no.2
    • /
    • pp.263-267
    • /
    • 2006
  • In both cosmetic and functional aspects, loss of digital pulp is a common problem. Compound or composite defects of the hand and fingers with exposed denuded tendon, bone, joint, or neurovascular structures may require flap coverage. Most often these lesions can be repaired by using simple local flap, neurovascular flap, thenar flap, and cross-finger flap. But microvascular reconstruction is sometimes needed for large defects. But Authors do not recommend these procedures in case of severe crushing injuries involving multiple finger pulp losses because they have possibility of damage of the vascular network and infection. So we applied distant flaps such as chest flaps, groin flaps, abdominal flaps and etc. And then we applied surgical rubber gloves for remodeling the flap after cutaneous healing. We have acquired satisfactory results, after the simple molding method for distant flap finger by using surgical rubber gloves treatment.