• Title/Summary/Keyword: Surgery, technique

Search Result 2,978, Processing Time 0.038 seconds

Role of Postoperative Radiation Therapy in the Management of Cervical Cancer (자궁경부암에서 수술 후 방사선치료의 역할)

  • Chun, Ha-Chung;Lee, Myung-Za
    • Radiation Oncology Journal
    • /
    • v.22 no.4
    • /
    • pp.265-270
    • /
    • 2004
  • Purpose: To evaluate the effectiveness of postoperative radiation therapy in cervical cancer patients and define the prognostic factors to affect survival rates. Materials and Methods: Eighty one patients with cervical cancer who were treated with postoperative radiation therapy following surgery at our institution between May 1992 and April 2000 were retrospectivelv analyzed. Forty two patients had stage IB disease, 17 had stage IIA disease, and remaining 22 had stage IIB disease, respectively. Histological examination revealed 76 squamous cell carcinoma and 5 adenocarclnoma. Sixty one patients were noted to have stromal invasion greater than 8 mm and 20 patients were noted to have stromal invasion 7 mm or less. Sixteen patients had parametrial invasion and 65 patients did not. Positive vaginal resection margin was documented in only eight patients and positive lymphovascular invasion was in twelve patients. All of the patients were treated with external beam radiation therapy alone. Majority of the patients were treated with 4 field brick technique to encompass whole pelvis. Total of 5,500 cGy was delivered to the primary surgical tumor bed. Minimum follow up period was four years. Results: Actuarial disease free survival rates for entire group of the patients were 95% and 89% at 2 and 5 years, respectively Five year disease free survival rates for patients with stage IB, IIA, and IIB disease were 97%, 87% and 70%, respectivelv. Local recurrences were documented in 5 patients. Cumulative local failure rate at 3 years was 6% Five year disease free survival rates for patients with stromal invasion greater than 8 mm and 7 mm or less were 88% and 92%, respectively (p>0.05). Five year disease free survival rate for patients with parametrial invasion was significantly lower than those with no invasion (72% vs 92%, p<0.05). Also there was significantly lower survival in patients with positive vaginal resection margin, compared with patients with negative resection margin (64% vs 94%, p<0.05). However, lymphovascular invasion was not a statistically significant prognostic factor Parametrial invasion and positive surgical resection margins were noted to be significant prognostic factors. Conclusions: Postoperative radiation therapy appears to be beneficial in controlling local disease in cervical cancer patients with high pathologic risk factors. Parametrial invasion and positive resection margins were noted to be significant prognostic factors to affect survival and more effective treatment should be investigated in these patients.

Hybrid Natural Orifice Transluminal Endoscopic Cholecystectomy in Dogs: Transgastric, Transcolonic and Transvaginal Approaches (개에서 자연개구부를 통한 하이브리드 내시경적 담낭절제술: 경위장관, 경결장 및 경질 접근법)

  • Kim, Soo-Hyun;Jeong, Seong-Mok;Shin, Sa-Kyeng;Kim, Seong-Su;Shin, Beom-Jun;Lee, Jae-Yeon;Park, Ji-Yeong;Kim, Myung-Cheol;Kim, Young-Il;Lee, Sang-Il;Kim, Ji-Yeon
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.497-505
    • /
    • 2011
  • Natural orifice transluminal endoscopic surgery is a newly emerging technique recently, with its many potential advantages in clinical practice. Cholecystectomy by Hybrid NOTES in this work, performed with single working channel endoscope in conjunction with a laparoscopic grasping forceps in dogs, is a "bridge" between laparoscopic procedure and pure NOTES. Three different approaches for cholecystectomy were carried out; transgastric, transcolonic and transvaginal. In all three approaches, abdominal opening was made by a 5 mm trocar, followed by making pneumoperitoneum of 4 mmHg with $CO_2$ insufflator. Transgastric cholecystectomy, single working channel endoscope was advanced to the peritoneal cavity through gastric incision in antral region made by endoscopic needle knife. Endoscope was retroflexed to visualize the gall bladder. Transcolonic access, incision for endoscopic entry was done at right ventral wall of descending colon, 15 cm inside from the anus. Incision in transvaginal access was made at right-ventral region, just caudal to the caudal tubercle. With the simple traction by the laparoscopic grasping forceps, good visualization of surgical field was obtained in all three groups. Cystic duct and artery were ligated with endoclips; for complete gall bladder dissection from liver, L-knife was used. Closure of incision sites were done in transgastric and transcolonic cholecystectomy by endoclips, not in transvaginal approach.

3D analysis of soft tissue around implant after flap folding suture (Flap folding suture를 활용한 판막의 고정에 따른 임플란트 주변 연조직 3차원 부피 변화 관찰)

  • Jung, Sae-Young;Kang, Dae-Young;Shin, Hyun-Seung;Park, Jung-Chul
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.37 no.3
    • /
    • pp.130-137
    • /
    • 2021
  • Purpose: The various suture techniques can be utilized in order to maximize the keratinized tissue healing around dental implants. The aim of this study is to compare the soft tissue healing pattern between two different suture techniques after implant placement. Materials and Methods: 15 patients with 18 implants were enrolled in this study. Simple implant placement without any additional bone graft was performed. Two different suture techniques were used to tug in the mobilized flap near the healing abutment after paramarginal flap design. Digital intraoral scan was performed at baseline, post-operation, stitch out, and 3 months after operation. The scan data were aligned using multiple points such as cusp, fossa of adjacent teeth, and/or healing abutment. After subtracting scan data at baseline with other time-point results, closed space indicating volume increment of peri-implant mucosa was selected. The volume of the close space was measured in mm3. The volume between two suture techniques at three time-points was compared using nonparametric rank-based analysis. Results: Healing was uneventful in both groups. Both suture technique groups showed increased soft tissue volume immediately after surgery. The amount of volume increment significantly decreased after 3 months (P < 0.001). Flap folding suture group showed higher median of volume increment than interrupted suture group after 3 months without any statistical significance (P > 0.05). Conclusion: After paramarginal flap reflection, the raised flaps stabilized by flap folding suture showed relatively higher volume maintenance after 3-month healing period. However, further studies are warranted.

The dosimetric guide of treatment modalities for Left side breast irradiation after conservative surgery (좌측 유방암 방사선 치료 시 치료 기법에 따른 선량적 고찰)

  • Kim, Tae Min;Moon, Sung Kong;Kim, Li Zzy;Kim, Se Young;Park, Ryeung Hwang;Kim, Joo Ho;Cho, Jung Heui
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.30 no.1_2
    • /
    • pp.153-160
    • /
    • 2018
  • Purpose : We retrospectively analyzed doses of each radiation therapy technique used in the treatment for left breast cancer patients after partial mastectomy through dose results for normalorgans and tumor volume to use this as a clinical reference for radiation therapy of domestic left breast cancer patients. Materials and Methods : 40 patients who underwent partial mastectomy on left breast cancer were classified in 3 treatment methods. The treatment plan was evaluated by HI(homogeneity index), $D_{95%}$, and CI(conformity index), and the $V_{hot}$ for gross tumor volume and clinical target volume of each treatment method. In Cyberknife treatment, tumor volume was the same as high dose volume in the other techniques, so no consideration was given to clinical target volume. Treatment plan evaluation for normal organs were evaluated by mean dose on ipsilateral lung, heart, left anterior descending artery, opposite breast and lung, and non-target tissue. Result : Treatment with volumetric arc radiotherapy(VMAT) showed $95.84{\pm}0.75%$ of $D_{95%}$ on the clinical target volume, significantly higher than that of 3D-CRT. The $D_{95%}$ value of the total tumor volume was slightly higher than the other treatments. In Cyberknife treatment, the dose to the normal organs was significantly lower than other treatments. Overall, the maximum dose and mean dose to the heart were $26.2{\pm}6.12Gy$ and $1.88{\pm}0.2Gy$ in VMAT treatment and $20.25{\pm}9.35Gy$ and $1.04{\pm}0.19Gy$ in 3D-CRT therapy, respectively. Conclusion : In comparison on 3D-CRT and VMAT, most of the dosimetric parameters for the evaluation of the treatment plan showed similar values, so that there is no significant difference in treatment plan evaluation. It is possible to select the treatment method according to the patient's anatomical structure or possibility of breath control. Cyberknife treatment is very useful treatment for normal organs because of its accurate dose exposure to the tumor volume However, it has restrictions to treat the local area, to have relatively long treatment time and to involve invasive procedure.

  • PDF

The comparison of lesion localization methods in breast lymphoscintigraphy (Breast lymphoscintigraphy 검사 시 체표윤곽을 나타내는 방법의 비교)

  • Yeon, Joon ho;Hong, Gun chul;Kim, Soo yung;Choi, Sung wook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.19 no.2
    • /
    • pp.74-80
    • /
    • 2015
  • Purpose Breast lymphoscintigraphy is an important technique to present for body surface precisely, which shows a lymph node metastasis of malignant tumors at an early stage and is performed before and after surgery in patients with breast cancer. In this study, we evaluated several methods of body outline imaging to present exact location of lesions, as well as compared respective exposure doses. Materials and Methods RANDO phantom and SYMBIA T-16 were used for obtaining imaging. A lesion and an injection site were created by inserting a point source of 0.11 MBq on the axillary sentinel lymph node and 37 MBq on the right breast, respectively. The first method for acquiring the image was used by drawing the body surface of phantom for 30 sec using $Na^{99m}TcO_4$ as a point source. The second, the image was acquired with $^{57}Co$ flood source for 30 seconds on the rear side and the left side of the phantom, the image as the third method was obtained using a syringe filled with 37 MBq of $Na^{99m}TcO_4$ in 10 ml of saline, and as the fourth, we used a photon energy and scatter energy of $^{99m}Tc$ emitting from phantom without any addition radiation exposure. Finally, the image was fused the scout image and the basal image of SPECT/CT using MATLAB$^{(R)}$ program. Anterior and lateral images were acquired for 3 min, and radiation exposure was measured by the personal exposure dosimeter. We conducted preference of 10 images from nuclear medicine doctors by the survey. Results TBR values of anterior and right image in the first to fifth method were 334.9 and 117.2 ($1^{st}$), 266.1 and 124.4 ($2^{nd}$), 117.4 and 99.6 ($3^{rd}$), 3.2 and 7.6 ($4^{th}$), and 565.6 and 141.8 ($5^{th}$). And also exposure doses of these method were 2, 2, 2, 0, and $30{\mu}Sv$, respectively. Among five methods, the fifth method showed the highest TBR value as well as exposure dose, where as the fourth method showed the lowest TBR value and exposure dose. As a result, the last method ($5^{th}$) is the best method and the fourth method is the worst method in this study. Conclusion Scout method of SPECT/CT can be useful that provides the best values of TBR and the best score of survey result. Even though personal exposure dose when patients take scout of SPECT/CT was higher than another scan, it was slight level comparison to 1 mSv as the dose limit to non-radiation workers. If the scout is possible to less than 80 kV, exposure dose can be reduced, and also useful lesion localization provided.

  • PDF

INFLUENCES OF DRY METHODS OF RETROCAVITY ON THE APICAL SEAL (치근단 역충전와동의 건조방법이 폐쇄성에 미치는 영향)

  • Lee, Jung-Tae;Kim, Sung-Kyo
    • Restorative Dentistry and Endodontics
    • /
    • v.24 no.1
    • /
    • pp.166-179
    • /
    • 1999
  • Apical sealing is essential for the success of surgical endodontic treatment. Root-end cavity is apt to be contaminated with moisture or blood, and is not always easy to be dried completely. The purpose of this study was to evaluate the influence of dry methods of retrocavity on the apical seal in endodontic surgery. Apical seal was investigated through the evaluation of apical leakage and adaptation of filling material over the cavity wall. To investigate the influence of various dry methods on the apical leakage, 125 palatal roots of extracted human maxillary molar teeth were used. The clinical crown of each tooth was removed at 10 mm from the root apex using a slow-speed diamond saw and water spray. Root canals of the all the specimens were prepared with step-back technique and filled with gutta-percha by lateral condensation method. After removing of the coronal 2 mm of filling material, the access cavities were closed with Cavit$^{(R)}$. Two coats of nail polish were applied to the external surface of each root. Apical three millimeters of each root was resected perpendicular to the long axis of the root with a diamond saw. Class I retrograde cavities were prepared with ultrasonic instruments. Retrocavities were washed with physiologic saline solution and dried with various methods or contaminated with human blood. Retrocavities were filled either with IRM, Super EBA or composite resin. All the specimens were immersed in 2% methylene blue solution for 7 days in an incubator at $37^{\circ}C$. The teeth were dissolved in 14 ml of 35% nitric acid solution and the dye present within the root canal system was returned to solution. The leakage of dye was quantitatively measured via spectrophotometric method. The obtained data were analysed statistically using one-way ANOVA and Duncan's Multiple Range Test. To evaluate the influence of various dry methods on the adaptation of filling material over the cavity wall, 12 palatal roots of extracted human maxillary molar teeth were used. After all the roots were prepared and filled, and retrograde cavities were made and filled as above, roots were sectioned longitudinally. Filling-dentin interface of cut surfaces were examined by scanning electron microscope. The results were as follows: 1. Cavities dried with paper point or compressed air showed less leakage than those dried with cotton pellet in Super EBA filled cavity (p<0.05). However, there was no difference between paper point- and compressed air-dried cavities. 2. When cavities were dried with compressed air, dentin-bonded composite resin-filled cavities showed less apical leakage than IRM- or Super EBA-filled ones (p<0.05). 3. Regardless of the filling material, cavities contaminated with human blood showed significantly more apical leakage than those dried with compressed air after saline irrigation (p<0.05). 4. Outer half of the cavity showed larger dentin-filling interface gap than inner half did when cavities were filled with IRM or Super EBA. 5. In all the filling material groups, cavities contaminated with blood or dried with cotton pellets only showed larger defects at the base of the cavity than ones dried with paper points or compressed air.

  • PDF

Individualized Determination of Lower Margin in Pelvic Radiation Field after Low Anterior Resection for Rectal Cancer Resulted in Equivalent Local Control and Radiation Volume Reduction Compared with Traditional Method (하전방 절제술을 시행한 직장암 환자에서 방사선조사 영역 하연의 개별화)

  • Park Suk Won;Ahn Yong Chan;Huh Seung Jae;Chun Ho Kyung;Kang Won Ki;Kim Dae Yong;Lim Do Hoon;Noh Young Ju;Lee Jung Eun
    • Radiation Oncology Journal
    • /
    • v.18 no.3
    • /
    • pp.194-199
    • /
    • 2000
  • Purpose : Then determining the lower margin of post-operative pelvic radiation therapy field according to the traditional method (recommended by Gunderson), the organs located in the low pelvic cavity and the perineum are vulnerable to unnecessary radiation. This study evaluated the effect of individualized determination of the lower margin at 2 cm to 3 cm below the anastomotic site on the failure patterns. Materials and Methods . Authors included ぉ patients with modified Astler-Coiler (MAC) stages from B2 through C3, who received low anterior resection and post-operative pelvic radiation therapy from Sept. 1994 to May 1998 at Samsung Medical Center, Sungkyunkwan University. The numbers of male and female patients were 44 and 44, and the median age was 57 years (range: 32-81 years). Three field technique (posterior-anterior and bilateral portals) by 6, 10, 15 MV X-rays was used to deliver 4,500 cGy to the whole pelvis followed by Sn cGy's small field boost to the tumor bed over 5.5 weeks. Sixteen patients received radiation therapy by traditional field margin determination, and the lower margin was set either at the low margin of the obturator foramen or at 2 cm to 3 cm below the anastomotic site, whichever is lower. In 72 patients, the lower margin was set at 2 cm to 3 cm below the anastomotic site, irrespectively of the obturator foramen, by which the reduction of radiation volume was possible in 55 patients ($76\%$). Authors evaluated and compared survival, local control, and disease-free survival rates of these two groups. Results : The median follow-up period was 27 months (range : 7-58 months). MAC stages B2 in 32($36\%$), B3 in 2 ($2\%$), Cl in 2 ($2\%$), C2 in 50 ($57\%$), and C3 in 2 ($2\%$) Patients, respectively. The entire patients' overall survival rates at 2 and 4 years were $94\%$ and $68\%$, respectively, and disease-free survival rates at 2 and 4 years were $86\%$ and $58\%$, respectively. The first failure sites were local only in 4, distant only in 14, and combined local and distant in 1 patient, respectively. There was no significant difference with respect to local control and disease-free survival rates ( p=0.42, p=0.68) between two groups of different lower margin determination policies. Conclusion : The new concept in the individualized determination of the lower margin depending on the anastomotic site has led to the equivalent local control and disease-free survival rates, and is expected to contribute to the reduction of unnecessary radiation-related morbidity by reduction of radiation volume, compared with the traditional method of lower margin determination.

  • PDF

Comparisons of Unicortical and Bicortical Lateral Mass Screws in the Cervical Spine : Safety vs Strength (경추부의 후관절 나사못 고정술에서 단피질삽입법과 양피질 삽입법 간의 특성에 관한 비교)

  • Park, Choon-Keun;Hwang, Jang-Hoe;Ji, Chul;Lee, Jae Un;Sung, Jae Hoon;Choi, Seung-Jin;Lee, Sang-Won;Seybold, Eric;Park, Sung-Chan;Cho, Kyung-Suok;Park, Chun-Kun;Kang, Joon-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.10
    • /
    • pp.1210-1219
    • /
    • 2001
  • Introduction : The purpose of this study was to analyze the safety, pullout strength and radiographic characteristics of unicortical and bicortical screws of cervical facet within cadaveric specimens and evaluate the influence of level of training on the positioning of these screws. Methods : Twenty-one cadavers, mean 78.9 years of age, underwent bilateral placement of 3.5mm AO lateral mass screw from C3-C6(n=168) using a slight variation of the Magerl technique. Intraoperative imaging was not used. The right side(unicortical) utilized only 14mm screws(effective length of 11mm) while on the left side to determine the length of the screw after the ventral cortex had been drilled. Three spine surgeons(attending, fellow, chief resident) with varying levels of spine training performed the procedure on seven cadavers each. All spines were harvested and lateral radiographs were taken. Individual cervical vertebrae were carefully dissected and then axial radiographs were taken. The screws were evaluated clinically and radiographically for their safety. Screws were graded clinically for their safety with respect to the spinal cord, facet joint, nerve root and vertebral artery. The grades consisted of the following categories : "satisfactory", "at risk" and "direct injury". Each screw was also graded according to its zone placement. Screw position was quantified by measuring a sagittal angle from the lateral radiograph and an axial angle from the axial radiograph. Pull-out force was determined for all screws using a material testing machine. Results : Dissection revealed that fifteen screws on the left side actually had only unicortical and not bicortical purchase as intended. The majority of screws(92.8%) were satisfactory in terms of safety. There were no injuries to the spinal cord. On the right side(unicortical), 98.9% of the screws were "satisfactory" and on the left side(bicortical) 68.1% were "satisfactory". There was a 5.8% incidence of direct arterial injury and a 17.4% incidence of direct nerve root injury with the bicortical screws. There were no "direct injuries" with the unicortical screws for the nerve root or vertebral artery. The unicortical screws had a 21.4% incidence of direct injury of the facet joint, while the bicortical screws had a 21.7% incidence. The majority of "direct injury" of bicortical screws were placed by the surgeon with the least experience. The performance of the resident surgeon was significantly different from the attending or fellow(p<0.05) in terms of safety of the nerve root and vertebral artery. The attending's performance was significantly better than the resident or fellow(p<0.05) in terms of safety of the facet joint. There was no relationship between the safety of a screw and its zone placement. The axial deviation angle measured $23.5{\pm}6.6$ degrees and $19.8{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The resident surgeon had a significantly lower angle than the attending or fellow(p<0.05). The sagittal angle measured $66.3{\pm}7.0$ degrees and $62.3{\pm}7.9$ degrees for the unicortical and bicortical screws, respectively. The attending had a significantly lower sagittal angle than the fellow or resident(p<0.05). Thirty-three screws that entered the facet joint were tested for pull-out strength but excluded from the data because they were not lateral mass screws per-se and had deviated substantially from the intended final trajectory. The mean pull-out force for all screws was $542.9{\pm}296.6N$. There was no statistically significant difference between the pull-out force for unicortical($519.9{\pm}286.9N$) and bicortical($565.2{\pm}306N$) screws. There was no significant difference in pull-out strengths with respect to zone placement. Conclusion : It is our belief that the risk associated with bicortical purchase mandates formal spine training if it is to be done safely and accurately. Unicortical screws are safer regardless of level of training. It is apparent that 14mm lateral mass screws placed in a supero-lateral trajectory in the adult cervical spine provide an equivalent strength with a much lower risk of injury than the longer bicortical screws placed in a similar orientation.

  • PDF