• 제목/요약/키워드: Surgery, technique

검색결과 2,934건 처리시간 0.034초

Radiographic evaluation of alveolar bone profile of maxillary anterior teeth in Korean young adult (한국인 성인의 상악 전치부 치조골 형태에 관한 방사선학적 연구)

  • Seo, Hyo-Seok;Chung, Chin-Hyung;Lim, Sung-Bin;Hong, Ki-Seok
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.461-471
    • /
    • 2006
  • In order to achieve a satisfactory esthetic result of periodontal surgery or implant in maxillary anterior area, periodontists must be aware of normal alveolar bone anatomy. The purpose of this study was to evaluate the relationship of alveolar bone morphology to tooth shape and form. 78(mean age : 25 yrs) periodontally healthy volunteers participated in this study. Two maxillary central incisor and one lateral incisor were selected to study. With minimal local anesthesia, gutta-percha cone inserted to labial gingival sulcus of selected teeth just after bone sounding with periodontal probe. Metal ball (4mm diameter) attached to palatal fossa of central incisor. Then, periapical radiograph was taken according to long cone paralleling technique. After film scan, labial alveolar bone profile reproduced along interproximal bone and apical ends of gutta-percha cones on computer screen. By utilizing computer program, the distance from height of interproximal bone to the labial bone crest in central incisor-central incisor and central incisor-lateral incisor area was measured and converted to real distance by using vertical length of metal ball on film. After measuring crown length & width of central incisor, the 10 individuals ranked lowest GW/L ratio (crown width/length ratio) and the 10 ranked highest were selected as having a long-narrow(group N), or a short-wide(group W) form of the central incisors. Means of the distance from height of interproximal bone to the labial bone crest of group N, W were calculated and compared by means of independent t-test. The results were as follows: 1. Mean distance from the height of the interproximal bone to the labial bone crest was $3.5{\pm}0.7mm$ between two central incisor, and $2.8{\pm}0.6mm$ between central and lateral incisor. 2. Mean GW/L ratio of group N was 0.57, and group W was 0.8. Mean distance from the height of the interproximal bone to the labial bone crest of group N was higher than group W in both measured area(measurements of group N, W were $3.9{\pm0.2mm$ and $3.5{\pm}0.2mm$ between two central incisor, $3.0{\pm}0.2mm$ and $2.8{\pm}0.2mm$ between central and lateral incisor), but there were no statistically significant differences when the groups were compared. Within the limits of the present study, there was a tendency that subjects with long-narrow teeth have more scalloped alveolar bone profile than subjects with short-wide teeth in upper anterior area, but no statistically significant differences were found.

Surface characteristics of a novel hydroxyapatite-coated dental implant

  • Jung, Ui-Won;Hwang, Ji-Wan;Choi, Da-Yae;Hu, Kyung-Seok;Kwon, Mi-Kyung;Choi, Seong-Ho;Kim, Hee-Jin
    • Journal of Periodontal and Implant Science
    • /
    • 제42권2호
    • /
    • pp.59-63
    • /
    • 2012
  • Purpose: This study evaluated the surface characteristics and bond strength produced using a novel technique for coating hydroxyapatite (HA) onto titanium implants. Methods: HA was coated on the titanium implant surface using a super-high-speed (SHS) blasting method with highly purified HA. The coating was performed at a low temperature, unlike conventional HA coating methods. Coating thickness was measured. The novel HA-coated disc was fabricated. X-ray diffraction analysis was performed directly on the disc to evaluate crystallinity. Four novel HA-coated discs and four resorbable blast medium (RBM) discs were prepared. Their surface roughnesses and areas were measured. Five puretitanium, RBM-treated, and novel HA-coated discs were prepared. Contact angle was measured. Two-way analysis of variance and the post-hoc Scheffe's test were used to analyze differences between the groups, with those with a probability of P<0.05 considered to be statistically significant. To evaluate exfoliation of the coating layer, 7 sites on the mandibles from 7 mongrel dogs were used. Other sites were used for another research project. In total, seven novel HA-coated implants were placed 2 months after extraction of premolars according to the manufacturer's instructions. The dogs were sacrificed 8 weeks after implant surgery. Implants were removed using a ratchet driver. The surface of the retrieved implants was evaluated microscopically. Results: A uniform HA coating layer was formed on the titanium implants with no deformation of the RBM titanium surface microtexture when an SHS blasting method was used. Conclusions: These HA-coated implants exhibited increased roughness, crystallinity, and wettability when compared with RBM implants.

Incidence of Paresthesia Related to the Insertion Length of Catheter during the Epidural Catheterization (경막외강 카테터 삽입 시 삽입 길이와 감각이상의 빈도)

  • Lim, Jun Goo;Kim, Young Jae;Cho, Jae Heung;Lee, Sang Eun;Kim, Young Hwan;Lim, Se Hoon;Lee, Jeong Han;Lee, Kun Moo;Cheong, Soon Ho;Choi, Young Kyun;Shin, Chee Mahn
    • The Korean Journal of Pain
    • /
    • 제20권1호
    • /
    • pp.50-53
    • /
    • 2007
  • Background: Continuous epidural catheterization is a popular and effective procedure for postoperative analgesia. However, continuous epidural catheterization has associated complications such as venous puncture, dural puncture, subarachnoid cannulation, suboptimal catheter placement, and paresthesia because the tip of the epidural catheter touches thenerves of the dura in the epidural space. In this study, we compared the incidence of paresthesia in two different lengths of epidural catheter insertion. Methods: One hundred women undergoing gynecologic or orthopedic surgery were enrolled in this prospective, double-blinded, randomized study. All patients were randomly divided into two groups based on the insertion length of the epidural catheter 2 cm (group A) or 4 cm (group B). A Tuohy needle was inserted in the lumbarspinal region with a bevel directed cephalad by use of the median approach, and then the epidural space was confirmed by the loss of resistance technique with air. While the practitioner inserted an epidural catheter into the epidural space, a blind observer checked for paresthesia or withdrawal movement. Results: In 97 included patients, 30.6% of the patients in group A (n = 49) had paresthesia, versus 31.3% in group B (n = 48). Withdrawal movements were represented in 2% and 6% of the patients in group A and group B, respectively. There was no difference in the incidence of paresthesia and withdrawal movement between the two groups. Conclusions: There is no clear relationship for the incidence of catheter-related paresthesia according to the catheter length inserted into the epidural space for epidural analgesia.

The Effect of Korean Mistletoe Extract M11C (Non-Lectin Components) on the Tumor Necrosis $Factor-{\alpha}$ Secretion from Mouse Splenic Macrophages and on the Inhibition of Sarcoma 180-Induced Tumor Growth in Mice (한국산 겨우살이 추출물 M11C(비렉틴 구성물질)의 생쥐 비장 대식세포로부터 Tumor Necrosis $Factor-{\alpha}$ 분비효과와 생쥐에 Sarcoma 180으로 유도된 육종암의 성장 억제효과)

  • Sung, Ki-Tai;Kang, Tae-Bong;Jun, Myung-Ha;Chang, Sung-Ho;Lee, Jun-Ho;Kim, Jong-Bae;Choi, Wahn-Soo;Yoo, Yung-Choon;Seong, Nak-Sul;Lee, Sung-Tae;Sung, Hyun-Jea;Her, Erk
    • Korean Journal of Pharmacognosy
    • /
    • 제34권3호통권134호
    • /
    • pp.210-217
    • /
    • 2003
  • Korean mistletoe (Viscum album) extract has been found to posses immunostimulatory activity. In this study, Korean mistletoe extract, M11C (non-lectin components), was used to know whether this extract might activate mouse splenic macrophages to produce tumor necrosis $factor-{\alpha}\;(TNF-{\alpha}$) and might play a role in anticancer. To know the effect of M11C on the production of $TNF-{\alpha}$, the splenic macrophages were treated by the M11C, and then collected the supernatant (M11C stimulated splenic macrophage-conditioned media; MSCM). MSCM was analyzed for the $TNF-{\alpha}$ secretion by means of ELISA and immunoblotting, and mRNA expression was analyzed by RT-PCR. The S-180 murine sarcoma model was established to know the effect of M11C on the inhibition of tumor growth. M11C had the effect of $TNF-{\alpha}$ production from splenic macrophages performed by ELISA technique. This ELISA data was reconfirmed by immunoblotting assay. The effects of M11C on the expression of $TNF-{\alpha}$ mRNA from the macrophages was also shown. M11C also had the inhibitory effect of S-180 tumor growth. These data suggest that Korean mistletoe extract M11C may be used for an immunomodulator.

A Retrospective Analysis of Treatment-Related Prognostic Factors for Local Recurrence after Primary Radiation Therapy for Patients with Primary T1N0 Glottic Cancer (T1N0 성문암의 방사선치료관련 예후 인자 분석)

  • Kim Su-Ssan;Kim Sang-Yoon;Nam Soon-Yuhl;Choi Seung-Ho;Cho Kyung-Ja;Kim Jong-Hoon;Ahn Seung-Do;Shin Seong-Soo;Song Si-Yeol;Choi Eun-Kyung;Lee Sang-Wook
    • Korean Journal of Head & Neck Oncology
    • /
    • 제19권1호
    • /
    • pp.34-40
    • /
    • 2003
  • Objective: To analyze the treatment-related parameters after the radiotherapy of T1N0 squamous cell carcinoma of the glottic larynx. Materials and Methods: Between October 1989 and August 2000, 54 patients with histologically proven T1N0 squamous cell carcinoma of the glottic larynx who received definitive radiation therapy in Department of Radiation Oncology, Asan Medical Center were analyzed. They were all males with age ranged from 31 to 80 years (median 61 years). 1997 AJCC stages were 31 T1a, 23 T1b. Patients were treated with 4-MV X-rays with a parallel-opposed two-field technique. Ten patients received 66.0-68.4Gy at 1.2Gy per fraction twice daily, 21 patients received 64.8-66.6Gy at 1.8Gy per fraction once daily, and 23 patients received 66.0Gy at 2.0Gy per fraction once daily. Follow-up period was 16-119 months (median 56 months). Results: 5-year overall survival and local control rates for patients with T1 lesions were 87.0% and 88.5%, respectively. 5-year local control with larynx preservation rate was 90.5%. Host and tumor-related prognostic factors including age, stage, anterior commissure involvement and tumor bulk proved not to be significant. Only shorter overall treatment time among treatment-related factors had correlation with imporved local control. Conclusion: Comparable high local control rate with organ preservation was achieved with primary radiation therapy and salvage surgery. Shortening of overall treatment time is related to improved local control rate. To determine the optimal fractionation scheme, randomized trial is mandatory.

Complete denture making in a patient of partial glossectomy using polished surface impression taking and direct metal laser sintering method: A case report (부분 설절제술을 받은 환자에서의 연마면 인상 및 Direct Metal Laser Sintering 을 이용한 총의치 제작 증례)

  • Jung, Yeon-Wook;Lee, Gyeong-Je;Kim, Hee-Jung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • 제57권4호
    • /
    • pp.350-355
    • /
    • 2019
  • For the success of complete denture, three essential requirements such as retention, stability and support are needed. Moreover, due to the absorption of residual ridge and scarring due to the surgery, when making a complete denture, which is difficult to form the mandibular lingual margins, various considerations such as the arrangement of the Non-anatomical dl non-anatomical teeth, the polished surface impression, the internally weighted metal framework and the use of the denture adhesive cream are necessary. In this case report, the patient has a severely resorbed edentulous ridge from severe periodontitis and has some soft tissue problems after the glossectomy due to tongue cancer. To obtain additional retention and stability, some trials such as polished surface impression taking, internally weighted metal insertion and minimal pressure impression were done for the better result. Moreover To make a metal framework that precisely shapes the desired three-dimensional shape and reduces the complicated process, minimal pressure impression method and direct metal laser sintering technique were used.

Radial Probe Endobronchial Ultrasound Using Guide Sheath-Guided Transbronchial Lung Biopsy in Peripheral Pulmonary Lesions without Fluoroscopy

  • Hong, Kyung Soo;Ahn, Heeyun;Lee, Kwan Ho;Chung, Jin Hong;Shin, Kyeong-Cheol;Jin, Hyun Jung;Jang, Jong Geol;Lee, Seok Soo;Jang, Min Hye;Ahn, June Hong
    • Tuberculosis and Respiratory Diseases
    • /
    • 제84권4호
    • /
    • pp.282-290
    • /
    • 2021
  • Background: Radial probe endobronchial ultrasound-guided transbronchial lung biopsy (RP-EBUS-TBLB) has improved the diagnostic yield of bronchoscopic biopsy of peripheral pulmonary lesions (PPLs). The diagnostic yield and complications of RP-EBUS-TBLB for PPLs vary depending on the technique, such as using a guide sheath (GS) or fluoroscopy. In this study, we investigated the utility of RP-EBUS-TBLB using a GS without fluoroscopy for diagnosing PPLs. Methods: We retrospectively reviewed data from 607 patients who underwent RP-EBUS of PPLs from January 2019 to July 2020. TBLB was performed using RP-EBUS with a GS without fluoroscopy. The diagnostic yield and complications were assessed. Multivariable logistic regression analyses were used to identify factors affecting the diagnostic yields. Results: The overall diagnostic accuracy was 76.1% (462/607). In multivariable analyses, the size of the lesion (≥20 mm; odds ratio [OR], 2.06; 95% confidence interval [CI], 1.27-3.33; p=0.003), positive bronchus sign in chest computed tomography (OR, 2.30; 95% CI, 1.40-3.78; p=0.001), a solid lesion (OR, 2.40; 95% CI, 1.31-4.41; p=0.005), and an EBUS image with the probe within the lesion (OR, 6.98; 95% CI, 4.38-11.12; p<0.001) were associated with diagnostic success. Pneumothorax occurred in 2.0% (12/607) of cases and chest tube insertion was required in 0.5% (3/607) of patients. Conclusion: RP-EBUS-TBLB using a GS without fluoroscopy is a highly accurate diagnostic method in diagnosing PPLs that does not involve radiation exposure and has acceptable complication rates.

A study on the development of severity-adjusted mortality prediction model for discharged patient with acute stroke using machine learning (머신러닝을 이용한 급성 뇌졸중 퇴원 환자의 중증도 보정 사망 예측 모형 개발에 관한 연구)

  • Baek, Seol-Kyung;Park, Jong-Ho;Kang, Sung-Hong;Park, Hye-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제19권11호
    • /
    • pp.126-136
    • /
    • 2018
  • The purpose of this study was to develop a severity-adjustment model for predicting mortality in acute stroke patients using machine learning. Using the Korean National Hospital Discharge In-depth Injury Survey from 2006 to 2015, the study population with disease code I60-I63 (KCD 7) were extracted for further analysis. Three tools were used for the severity-adjustment of comorbidity: the Charlson Comorbidity Index (CCI), the Elixhauser comorbidity index (ECI), and the Clinical Classification Software (CCS). The severity-adjustment models for mortality prediction in patients with acute stroke were developed using logistic regression, decision tree, neural network, and support vector machine methods. The most common comorbid disease in stroke patients were hypertension, uncomplicated (43.8%) in the ECI, and essential hypertension (43.9%) in the CCS. Among the CCI, ECI, and CCS, CCS had the highest AUC value. CCS was confirmed as the best severity correction tool. In addition, the AUC values for variables of CCS including main diagnosis, gender, age, hospitalization route, and existence of surgery were 0.808 for the logistic regression analysis, 0.785 for the decision tree, 0.809 for the neural network and 0.830 for the support vector machine. Therefore, the best predictive power was achieved by the support vector machine technique. The results of this study can be used in the establishment of health policy in the future.

Ex Vivo Raman Spectroscopy Measurement of a Mouse Model of Alzheimer's Disease (라만 기반 치매 모델의 뇌조직 분광 특성 측정)

  • Ko, Kwanhwi;Seo, Younghee;Im, Seongmin;Lee, Hongki;Park, Ji Young;Chang, Won Seok;Kim, Donghyun
    • Korean Journal of Optics and Photonics
    • /
    • 제33권6호
    • /
    • pp.331-337
    • /
    • 2022
  • Raman spectroscopy is an optical technique that can identify molecules in a label-free manner, and is therefore heavily investigated in various areas ranging from biomedical engineering to materials science. Probe-based Raman spectroscopy can perform minimally invasive chemical analysis, and thus has potential as a real-time diagnostic tool during surgery. In this study, Raman experimentation was calibrated by examining the Raman shifts with respect to the concentrations of chemical substances. Raman signal characteristics, targeted for normal mice and cerebral tissues of the 5xFAD dementia mutant model with accumulated amyloid beta plaques, were measured and analyzed to explore the possibility of diagnosis of Alzheimer's disease. The application to the diagnosis of dementia was cross-validated by measuring Raman signals of amyloid beta. The results suggest the potential of Raman spectroscopy as a diagnostic tool that may be useful in various areas of application.

Value of Image Subtraction for the Identification of Hepatocellular Carcinoma Capsule on Gadoxetic Acid-Enhanced MRI (가도세틱산-조영증강 MRI에서 간세포암 피막 발견에 대한 영상차감기법의 진단적 가치)

  • Kim, Hyunjung;Ahn, Jhii-Hyun;Moon, Jin Sil;Cha, Seung-Whan
    • Journal of the Korean Society of Radiology
    • /
    • 제79권6호
    • /
    • pp.340-347
    • /
    • 2018
  • Purpose: To evaluate value of image subtraction for identifying hepatocellular carcinoma (HCC) capsule on gadoxetic acid-enhanced MR images. Materials and Methods: This study involved 108 patients at risk of HCC preoperatively examined using gadoxetic acid-enhanced MRI with hepatic resection between May 2015 and February 2017. We evaluated qualities of subtraction images and presence of capsular appearance on portal venous or transitional phases conventional and subtraction images. We assessed effect of capsular appearance on subtraction images on HCC. Results: After excluding 1 patient who had treated by transarterial chemoembolization prior to surgery and 33 patients with unsatisfactory subtraction image qualities, 82 focal hepatic lesions (73 HCC, 5 non-HCC malignancies, and 4 benign) from 74 patients were analyzed. Regarding detection of capsules, sensitivity, accuracy, and area under the receiver operating characteristic curve (AUC) on subtraction images were significantly higher than those on conventional images (95.4%, 89.0%, and 0.80, respectively; p < 0.001), though specificities were same (64.7%). For diagnosis of HCC, sensitivity, accuracy, and AUC on subtraction images were significantly higher than on conventional images (82.2%, 79.3%, and 0.69, respectively; p = 0.011), though specificities were identical (55.6%). Conclusion: Portal venous or transitional phase gadoxetic acid-enhanced MRI subtraction images could improve detection of HCC capsule.