• Title/Summary/Keyword: Surge Control

Search Result 251, Processing Time 0.027 seconds

A Development of Intelligent Controller for Phase Control in Main Circuit Breaker (주회로차단기 투입전원 위상제어를 위한 지능형 제어기 개발)

  • Oh, Yong-Kuk;Kim, Jae-Won;Ryu, Joon-Hyoung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.11
    • /
    • pp.755-761
    • /
    • 2017
  • In railways powered by AC power, the main circuit breaker (MCB) is used for supplying the electric power to the catenary of the vehicle. Generally, the main circuit breaker is located between the pantograph and the main transformer, and the phase of the power applied to the vehicle changes according to the operation timing of the main circuit breaker. The operation of the main circuit breaker should be actively controlled according to the phase of the power source, since the phase of the power causes unintended transient states in the vehicle's electrical system in the form of an inrush current and surge voltage. However, the MCB has a delay time when it operates which is not constant. Therefore, an intelligent controller is needed to predict the operation delay time and control the opening and closing of the MCB.

A Study of Clinical Efficacy of GnRH Antagonist (Cetrorelix) Single and Multiple Dose Protocol for Controlled Ovarian Hyperstimulation (과배란유도에서 GnRH Antagonist (Cetrorelix) Single 및 Multiple Dose Protocol의 임상적 효용성에 관한 연구)

  • Ko, Sang-Hyeon;Kim, Dong-Ho;Bae, Do-Hwan;Lee, Sang-Hoon
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.29 no.4
    • /
    • pp.259-267
    • /
    • 2002
  • Objective: This study was performed to compare the clinical outcomes of GnRH antagonist (Cetrorelix) single dose and multiple dose protocols for controlled ovarian hyperstimulation with GnRH agonist long protocol. Materials and Method: From September 2001 to March 2002, 48 patients (55 cycles) were performed controlled ovarian hyperstimulation for ART using by either GnRH antagonist and GnRH agonist. Single dose of 3 mg GnRH antagonist was administered in 15 patients (17 cycles, single dose group) at MCD #8 and multiple dose of 0.25 mg of GnRH antagonist was administered in 15 patients (18 cycles, multiple dose group) from MCD #7 to hCG injection day. GnRH agonist was administered in 18 patients (20 cycles, control group) by conventional GnRH agonist long protocol. We compared the implantation rate, number of embryos, and clinical pregnancy rate among three groups. Student-t test and Chi-square were used to determine statistical significance. Statistical significance was defined as p<0.05. Results: There were no significant differences in ampules of used gonadotropins, number of mature oocytes, obtained embryos between single and multiple dose group, but compared with control group, ampules of used gonadotropins, number of mature oocytes, obtained embryos were decreased significantly in both groups. Clinical pregnancy rate and implantation rate were not different in three groups. There were no premature LH surge and ovarian hyperstimulation syndrome in three groups. Multiple pregnancy were occurred 1 case in multiple dose group and 2 case in control group. Conclusions: GnRH antagonist is a safe, effective, and alternative method in the controlled ovarian hyperstimulation compared with GnRH agonist. Clinical outcomes and efficacy of both single and multiple dose protocol are similar between two groups.

Effects of Aromatase Inhibitor on Reproductive Hormone Profiles and Ovulation Induction (방향화효소억제제의 생식호르몬 분비와 배란유도에 대한 효과)

  • Kim, Sook-Hyun;Kim, Jeong-Ah;Park, Joon-Cheol;Bae, Jin-Gon;Shin, So-Jin;Kwon, Sang-Hoon;Cho, Chi-Heum;Yoon, Sung-Do;Cha, Soon-Do;Kim, Jong-In;Rhee, Jeong-Ho
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.2
    • /
    • pp.143-153
    • /
    • 2008
  • Objective: To investigate the effects of aromatase inhibitor on reproductive hormone profiles and evaluate it's ovulation inducing capability in anovulatory infertile women. Methods: We quantified the blood levels of reproductive hormones from 30 healthy normal cycling women in natural cycle (control) and letrozole medicated cycle (study). LH, FSH, estradiol, testosterone, DHEA-S were quantified on third, 11th, 21th day in both cycles, and on 21th day, progesterone was added. Sixth anovulatory infertile women received either letrozole or clomiphene citrate for ovulation induction (n=30 in each groups). We compared the clinical parameters such as ovulation rate, pregnancy rate, the day of LH surge, number of follicles and endometrial thickness, cervical mucus amount, spinnbarkeit, mean diameter of follicles on the day of LH surge. Results: Letrozole had no effect on the LH, FSH, estradiol, DHEA-S secretion but there were significant increase in testosterone level on day 11 and progesterone level on day 21 in letrozole medicated cycle compared than control cycle ($0.40{\pm}0.16$ vs $0.28{\pm}0.11\;ng/ml$, p=0.002, $18.18{\pm}13.07$ vs $8.38{\pm}7.64\;ng/ml$, p=0.001, respectively). In comparison between letrozole and clomiphene groups, there were no significant difference in ovulation rate, pregnancy rate, number of mature follicle, mean diameter of follicles, but showed earlier LH surge, thicker endometrium, more cervical mucus, and higher spinnbarkeit in letrozole group ($12.12{\pm}2.46$ vs $14.52{\pm}3.18$ days, p=0.006, $10.48{\pm}1.23$ vs $8.52{\pm}0.93\;mm$, p=0.000, $2.04{\pm}0.61$ vs $1.57{\pm}0.59$, p=0.012, $6.00{\pm}1.12$ vs $4.95{\pm}1.61\;cm$, p=0.003, respectively). Conclusion: Letrozole may augment folliculogenesis and improve the endometrial condition for implantation in normal cycling women. Ovulation efficacy of letrozole in anovulatory women was comparable to clomiphene citrate and letrozole may be more physiological in ovulation induction.

A Case Report of Acute Nicotine Poisoning from Subcutaneous Injection of Nicotine Solution for Electronic Cigarette (전자담배 용액의 피하 주사에 의한 급성 니코틴 중독 1례)

  • Choi, Jiun;Ko, Dong Ryul;You, Je Sung;Chung, Sung Phil
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.15 no.1
    • /
    • pp.60-64
    • /
    • 2017
  • Nicotine-poisoning related to the electronic cigarettes (e-cigarette) is increasing worldwide. Moreover, the American Association of Poison Control Centers has advised the public to use caution with e-cigarette devices and highly concentrated liquid nicotine after a surge in related poisonings. We report here the first case of nicotine poisoning from self-injected e-cigarette fluid in Korea. A 17-year-old male patient subcutaneously injected himself with 0.5 ml of nicotine solution for an electronic cigarette via the dorsum of his hand, after which he complained of nausea, vomiting, dizziness and dyspnea. His vital signs were within the normal range, but his mental status was drowsy. He was admitted for observation and the symptoms disappeared the following day. Sinus bradycardia with a rate of 45/min was observed on the third hospital day, but improved after 6 hours. He was discharged without complications.

Output Filter Design for Conducted EMI Reduction of PWM Inverter-Fed AC Motor Drive System (PWM 인버터 시스템에서의 전도노이즈 저감을 위한 출력필터 설계에 관한 연구)

  • 김이훈;박규현;원충연;김영석;최세완
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.546-555
    • /
    • 2001
  • In this paper filtering techniques to reduce the adverse effects of motor leads on high-frequency PWM inverter fed AC motor drives are presented. The filter was designed to keep the motor terminal from the cable surge impedance to reduce overvoltage reflections ringing and the dv/dt, di/dt, at the motor terminals. Specially the output filter is used to limit the rate of the inverter output voltage and reduce common mode noise to the motor, The performance of the output filter is evaluated through simulations and experiment on PWM inverter-fed AC motor drive. An experimental PWM drive system reduction of conducted EMI was implemented on an available TMS320C31 microprocessor control board Finally, experimental result shows inverter output filter reduces more common mode voltage than low pass filter also reduce overoltage and ringing at the motor terminal.

  • PDF

Process Development of a Standard Operating Procedure (SOP) for the Manufacturing of Standardized Distribution Boards (규격화된 분전반 제작을 위한 표준작업절차(SOP)의 공정 개발)

  • Ko, Wan-Su;Lee, Byung-Seol;Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.5
    • /
    • pp.21-27
    • /
    • 2018
  • The purpose of this study is to develop a SOP (Standard Operating Procedure) for a distribution board that can monitor the leakage current of a load distribution line in real time. The developed distribution board was fabricated by applying IEC 61439-1. It consists of the distribution board and an alarm device. The work process for making the distribution board was compliant with the KEMC (Korea Electrical Manufacturers Cooperative) regulations. And the AC distribution board range is 1,000 V. In addition, the voltage in DC is less than 1500 V. The distribution board receives a 3-phases and 4-wires power supply system and can supply power to the load of a maximum of 32 single or three phase distribution circuits. Also, leakage current measured on the power distribution board was used by sensors installed. The SOP of the developed distribution board consists of the installation standards for the short circuit alarm device and sensor, the surge protection device, switches and indication lamps, and other devices. The operation procedure was prepared so that each manufacturing step of the distribution board must be confirmed by the persons in charge of preparation, production, quality control and approval before moving forward to the next step.

Design & characteristics of impulse current test system for station class(up to class 5) (송변전급(up to class 5) Impulse current test system의 설계 및 특성)

  • Kim, Seok-Sou;Choi, Ike-Sun;Kang, Young-Sik;Park, Byung-Rak;Park, Tae-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.1146-1149
    • /
    • 2004
  • A new developed impulse current test system(100kV, 250kJ)is presented, which can carry out all impulse current and performance tests on surge arrester sections with rated voltage up to 12kV according to IEC 60099-4(2001). The maximum achievable peak value is 200kA for the impulse current $4/10{\mu}s$ and 60kA for the $30/80{\mu}s$ and $8/20{\mu}s$. The long duration current impulse is realized from class 1 to class 5. The digital transient recorder(4 channels 60MS/S 10bit) is used for measuring AC voltage, impulse current, reference voltage and leakage current. The complex control, measuring, evaluation and data storage system is controlled by one industrial PC system.

  • PDF

The Evolution of Green Growth Policy: An Unwelcome Intrusion on Global Environmental Governance?

  • Park, Jeongwon
    • East Asian Economic Review
    • /
    • v.17 no.2
    • /
    • pp.207-241
    • /
    • 2013
  • The notion of green growth emerged in 2009. Since then, policy makers and practitioners have largely adopted the term. Although rather intermittently, there have been academic observations on green growth, with the term often being cited as a paradigm and a policy guide for generating new sources of growth. The most important reasons for the surge in green growth today as a new trend and an international agenda item are the rather unsatisfactory results and pitfalls of sustainable development, which has failed at promoting a tangible international environmental principle or a concrete policy framework. Green growth has been proposed as an alternative simultaneously to foster the dynamics of global environmental governance and to reinvigorate the world economy. This study examines to what extent green growth plays a complementary role in existing global environmental governance. Available evidence provides reasonable grounds for arguing that a positive outcome may well be expected from the evolution of green growth architecture and followed by practical policies. It became a global agenda out of a few influential national governments' control. However, decision makers in the leading countries, both developed and developing must be willing to continue implementing what has been discussed and agreed thus far, beyond changes in political leadership and administrations.

Dynamic Response of Hydraulic Transmission Lines with an Accumulator (축압기를 갖는 유압관로의 동특성에 관한 연구)

  • Lee, Ill-Yeong;Hong, Bong-Ki
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.17 no.1
    • /
    • pp.29-34
    • /
    • 1981
  • More recently, unsteady flow in small-diameter pipes plays a major role in liquid propellantrocket systems, hydraulic and pneumatic control system, and elsewhere. And it has shown that line dynamics can have a marked effect on the hydraulic system characteristics. In this paper, transfer function of hydraulic lines with an accumulator and an outlet orifice is' developed and compared with experimental data from frequency response tests at various airvolume(V.) and the location of accumulator(ld1t), so that their performance may be correctly and easily predicted and the design of the systems incorporating them improved. The obtained results are as follows: 1. The dynamic response of hydraulic lines may be analyzed more accurately by use of the viscous term(22) in unsteady laminar flow. 2. There was good agreement between the theoretical and experimental results of this investigation, and hydraulic systems with liines included an accumulator can be analyzed more accurately by use of the pressure transfer function given by eq. (16). 3. For the mitigation of surge in hydraulic lines, it is more effective that the location ofaccumulator is close to the pipe outlet side. 4. According to the gas volume of accumulator is increased(the sealing pressure is close tomean line pressure), the damping effect of pressure wave is improved.

  • PDF

Design and Analysis of 20 W Class LED Converter Considering Its Control Method (제어 방식에 따른 20 W급 LED Converter 설계 및 분석)

  • Jeong, Young-Gi;Kim, Sung-Hyun;Park, Dae-Hee
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.1
    • /
    • pp.53-57
    • /
    • 2012
  • In this paper, by designing 20 W class driving circuit for driving high-power LED (Light Emitting Diode), we are going to comparatively carry out the analysis of characteristics for power circuit according to each design method. In this case, 200 V 60 Hz was performed as input data. The electrical characteristics such as voltage, current and ripple are checked for constant current circuit and constant voltage circuit in the LED module. In addition, as the ripple has an influence on illumination of LED light, low temperature working (-20 [$^{\circ}C$]) and high temperature working(80 [$^{\circ}C$]) are measured to make sure the ripple characteristics in accordance with temperature. In low temperature operation -20 [$^{\circ}C$] measurements, both constant current circuit and constant-voltage circuit were less impacted on input fluctuation, whereas in the high temperature operation 80 [$^{\circ}C$], current voltage in constant voltage circuit was surge after 430 [hour]. Voltage current ripple of constant current circuit was much less than constant voltage circuit, therefore we can show that constant current circuit is more stable.