• 제목/요약/키워드: Surge Arrester

검색결과 142건 처리시간 0.025초

피뢰기의 ZnO 소자 성능평가 분석 (Performance Evaluation and Analysis of ZnO Element for Distribution Line Arresters)

  • 김석수;김경운;박영창;조한구;박태곤;송일근;김주용
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 춘계학술대회 논문집 유기절연재료 방전 플라즈마
    • /
    • pp.78-81
    • /
    • 2000
  • Metal oxide surge arrester were developed in the late 1970s, and were immediately adopted as significant breakthrough in over voltage protection of power system. Work was continued throughout the world on the design, development and application of metal oxide surge arrester. This paper describes the evaluating test and results of practical use for analyzing the performance of gapless metal oxide surge arresters under various type test. In the result, ZnO element exhibited badness rate of 6.95 percent.

  • PDF

국내 지중배전시스템의 서어지 보호방안 (Surge Protection Method of the Underground Distribution System in Korea)

  • 이재봉;정연하;박철배
    • 조명전기설비학회논문지
    • /
    • 제22권10호
    • /
    • pp.84-88
    • /
    • 2008
  • 본 논문은 2007년에 게재된 "지중배전케이블의 서어지 전파특성 실증연구"를 통해 검증된 서어지 전파특성을 고려하여 피뢰기를 이용한 보호효과를 ATP-EMTP(Electro-Magnetic Transient Program)로 해석하고 국내 상황에 적합한 보호방법을 제시하고자 한다. 국내 지중배전시스템은 입상주에 설치된 피뢰기에 의해 보호되고 있지만 서어지가 케이블의 말단 개방점에서 두배 정도로 상승하여 배전설비의 절연을 위협할 수 있으므로 추가적인 보호 방법이 필요하다. 본 논문에서 추가적인 보호 방법으로 제안하는 스카우트 방법은 입상주 피뢰기 전 후단 전주에 피뢰기를 추가 설치하는 방법으로 지중배전선로에 피뢰기를 설치하기 곤란한 경우나 지중배전선로용 엘보우 피뢰기를 개발하여 적용하는 것보다 경제성에서 유리하고 설치 및 유지보수 측면에서도 효과적일 것으로 기대된다.

산화아연 피뢰기 소자와 전극사이에 발생하는 방전광 현상 (Discharge Luminous Phenomena Caused Between ZnO Surge Arrester Block and Electrodes)

  • 이복희;박건영;강성만
    • 조명전기설비학회논문지
    • /
    • 제19권3호
    • /
    • pp.44-50
    • /
    • 2005
  • 본 논문에서는 산화아연(이하 ZnO) 피뢰기 열화진행의 한 요인으로 예측되는 전극과 ZnO소자 사이에서 발생하는 방전광 현상에 관한 연구를 수행하였다. 이를 위해 $8/20[{\mu}s]$, 최대 10[kA]의 뇌임펄스전류를 발생시키는 뇌임펄스전류 발생장치를 설계${\cdot} $제작하였다. 실험결과, 상${\cdot}$하부의 전극 부근에서 발생하는 방전광의 형상은 인가되는 뇌임펄스의 극성에 따라 다르게 나타났으며 상대적으로 (-)극의 전극부근에서 방전광이 더 강하고 활발하게 발생하는 것으로 관찰되었다. 또한 전극의 면적에 따른 방전광의 세기는 전극의 면적이 증가할수록 감소하는 것으로 관측되었다. 동시에 전극과 소자의 접촉상태도 방전광의 발생과 매우 밀접한 관계가 있는 것으로 확인되었다. 따라서 배전급 ZnO피뢰기의 기존 전극구조는 보완이 필요하며 ZnO피뢰기 제품의 성능향상 및 지속적인 성능유지를 위해서는 환형구조 대신 내부면적이 있는 원판구조로 교체하는 것이 바람직하다고 판단된다.

지중배전선로용 피뢰기를 고려한 과도현상 해석 (Analysis of Transient Phenomena Considering Arrester in Underground Distribution Line)

  • 윤창섭;이종범;이재봉
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.276-278
    • /
    • 2007
  • This paper describes the analysis to install an arrester for an underground distribution line effectively. Currently, the underground distribution cable is protected by the arrester connected with overhead distribution line. However, riser pole arrester can't protect all parts of cable like the end of the underground distribution cable. To solve this problem, we installed the arrester on each cable and have measured the overvoltage made by lightning surge in each situation. The location to get effective results has been decided from the measured voltage above.

  • PDF

워터 햄머 흡수기의 압력흡수 효과에 관한 연구 (A Study of Surge Pressure Absorption by Water Hammer Arrester in Water Supply Piping System)

  • 이용화;유지오
    • 설비공학논문집
    • /
    • 제12권12호
    • /
    • pp.1066-1072
    • /
    • 2000
  • This study is to investigate the pressure wave characteristics and the absorption of maximum and minimum pressure generated by instantaneous valve closure at the end of the straightening copper piping system with and without a water hammer arrester. Experiments were conducted under the following conditions : initial pressure 1~5 bar, flow velocity 0.6~3.0 m/s, water temperature $20^{\circ}C$ and air volume of water hammer arrester $80~180^cm^3$. Experimental results show that the optimum air volume of water hammer arrester is 110㎤.

  • PDF

내뢰성 향상을 위한 154 kV 송전선용 피뢰기의 성능 시험 (A Type Test of 154 kV Transmission Line Arrester for improvement of lightning performance)

  • 곽주식;강연욱;우정욱;심응보;박윤석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.454-456
    • /
    • 2003
  • This paper describes a type test results of 154 kV transmission line arrester with external gap. The test was carried on surge arrester unit and line arrester with external gap, respectively. Withstand voltage test demonstrate the voltage withstand capability of the line arrester with external series gap under the dry and wet conditions. In insulation coordination test external series gap shall be discharged every time when lightning impulse voltage with the steepness of more than 1500 $kV/{\mu}s$ are applied under the wet condition.

  • PDF

고분자 피뢰기의 기밀특성에 관한 연구 (Sealing Integrity of polymeric ZnO Surge Arresters)

  • Liang, He-Jin;Han, Se-Won;Cho, Han-Goo;Kim, In-Sung
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1997년도 추계학술대회 논문집
    • /
    • pp.258-261
    • /
    • 1997
  • The sealing integrity is related to the safe operation of arrester the prime failure reason of porcelain housed arresters is moisture ingress. To be a meaningful tests a polymer arrester sealing test must be a realistic acceleration of field service. We think the test should be an accelerating course of actual temperatures, the enduring property to mechanical load and temperatures should be considered together. A union test method consisting of the thermal mechanical test and thermal cycling test is proposed to test the sealing integrity of polymeric arresters, which uses dielectric loss, leakage current 1mA DC voltage and partial discharge as the diagnostic techniques, and the test results were presented. The comparison states that the TMTCUT method is suitable fur the test of sealing integrity of polymeric arresters. .

  • PDF

중첩전압(직류+교류 60Hz)에서 산화아연 피뢰기 소자의 누설전류 특성 (The characteristic of leakage current in ZnO surge arrestor elements with mixed direct and 60Hz voltage)

  • 이복희;박건영;강성만;최휘성;오성균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.186-188
    • /
    • 2003
  • The ZnO surge arrester is the protective device for limiting surge voltages on equipment by diverting surge current and returning the device to its original status. The occurrence of overvoltage appears in any phase to AC power supply system and it appears in mixing AC and impulse voltages, moreover because HVDC power supply system uses converter in semiconductor, it makes mixed DC and high harmonics voltages. In this study, the various mixed AC and DC voltages was made for investigating the degradation effect of ZnO arrester according to mixed voltage. As a result, the increase of DC component to mixed voltages causes the increase of resistive component of total leakage current to ZnO block. In changing V-I curve for mixed voltages, the cross-over point acts a factor as making the proper capacitor size of an equivalent circuit for ZnO block.

  • PDF

전력용 피뢰기의 MOV 미립화와 에너지 내량 특성 연구 (Study on Surge Absorption Capability for Power Arrester with MOV Micro-milling Characteristics)

  • 한세원;조한구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2004년도 춘계학술대회 논문집 방전 플라즈마 유기절연재료 초전도 자성체연구회
    • /
    • pp.120-124
    • /
    • 2004
  • The protection performance and energy absorption capability are important for both MOAs for distribution lines and MOAs for high voltage systems, therefore the manufacturing technique of ZnO varistor elements with high ability against surge impacts is great important for high voltage systems. But until now ZnO varistors for low voltage class have been developed in Korea, ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems depend on an import from advanced countries, such as Japan or U.S.A, which have developed its in the late 1980s. So in the aspect of taking independent technique the development of ZnO varistors with the rate discharge current of 5, 10kA class for high voltage systems is important. In this research project ZnO varistor elements with diameters of 35mm and 70mm for the rate discharge current of 5, 10kA class for high voltage systems are manufactured, then various chemical composition and processing variables affected the electrical and the physical characteristics of these ZnO varistors are investigated.

  • PDF

직격뢰 침입시 배전계통 절연설계 (Insulation Design of Distribution Systems in Case of the Stroke of Direct Lightning Surge)

  • 정채균;김상국;이종범;서재호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권4호
    • /
    • pp.238-247
    • /
    • 2004
  • This paper describes the insulation coordination scheme of line in distribution system when the direct lightning surge strikes. The BIL that is applied to distribution system is not properly considered the performance and operation of arresters. Because of that, the high BIL is being used at partial system. This paper variously analyses the lightning overvoltage of line and equipment with earth of overhead grounding wire and installation types of arrester. From these result. authors examine the rationality of BIL.