• 제목/요약/키워드: Surface response

검색결과 4,776건 처리시간 0.039초

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • 대한의용생체공학회:의공학회지
    • /
    • 제6권2호
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

High Resolution HC$_3$N Observations toward the Central Region of Sagittarius B2

  • H.S-Ching;Oh, M.ishi;M.Morimoto
    • 한국우주과학회:학술대회논문집(한국우주과학회보)
    • /
    • 한국우주과학회 1993년도 한국우주과학회보 제2권2호
    • /
    • pp.17-17
    • /
    • 1993
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70${\pm}$1.32mmHg/min)compared to CF dialyzers(4.32${\pm}$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500,550,570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500,550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100,300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3,000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.

  • PDF

목화진딧물과 배추좀나방에 대한 thiamethoxam의 살충효과 및 작용특성 (Action properties and insecticidal effects of thiamethoxam to the melon aphid, Aphis gossypii, and diamondback moth, Plutella xylostella)

  • 장철;황인천;유용만;최광렬
    • 농약과학회지
    • /
    • 제2권3호
    • /
    • pp.126-136
    • /
    • 1998
  • 신규화합물인 thiamethoxam의 목화진딧물과 배추좀나방에 대한 살충효과를 분석하기 위하여 일반적인 생물검정 방법을 이용하여 접촉 및 섭식독성반응과 속효성, 침투이행성, 잔효성 등을 다른 약제들과 비교 검토하였다. Spray법을 이용하여 접촉독성을 조사한 결과 목화진딧물에 대한 반수치사농도($LC_{50}$)는 유기인계인 acephate 41.9 ppm, 카바메이트인 carbosulfan 5.2 ppm, 니코틴계인 imidacloprid와 thiamethoxam은 각각 1.1, 0.7 ppm을 나타냈다. 배추좀나방을 대상으로 엽침적법으로 처리했을 경우 섭식독성은 2령 유충의 경우 $LC_{50}$값이 imidacloprid 64.9 ppm, thiamethoxam 24.6 ppm, acetamiprid 15.2 ppm, 3령 유충에서는 각각 125.1, 42.7, 27.8 ppm이었고, 4령 유충에서는 각각 241.1, 44.5, 23.9 ppm으로 령기별로 약간의 차이를 보였다. 한편, 목화진딧물을 대상으로 한 약제의 속효성을 측정하는 반수치사시간 ($LT_{50}$)은 접종 후 약제살포시에 imidaclopid 26.6분, thiamethoxam 28.0분, carbosulfa 30.3분, acephate 41.7분의 순이었고, 약제살포 후 접종하였을 때에는 thiamethoxam 95.5분, imidaclopid 118.0분, carbosulfan 122.9분으로 진딧물에 직접 살포한 것이 살충시간을 단축시켰다. 또한, 잎표면으로부터 이면으로의 약효성분의 이행성을 비교한 결과 $LT_{50}$값은 thiamethoxam 162.2분, imidacloprid 168.9분, carbosulfan 564.1분이었고, 하위 잎으로부터 최상위 잎으로의 이행성에서는 carbosulfan 2.3일, thiamethoxam 2.9일, imidacloprid 3.0일, acephate 8.8일이었다. 뿌리로부터 잎으로의 이행성은 carbosulfan 0.6일, imidacloprid 1.0일, thiamethoxam 1.0일, acephate 13.8일로서 thiamethoxam의 침투이행성이 가장 빠른 것으로 나타났다. Spray법을 이용한 잔효성 시험결과 thiamethoxam과 imidaclopid는 약제처리 후 10일째에도 80%이상의 높은 살충효과를 나타내어 잔효성이 우수하였다.

  • PDF

토끼 경골에서 hydroxyapatite 코팅의 면적에 따른 임프란트의 뒤틀림 제거력과 조직계측학적 분석 (Removal Torque and Histometric Evaluations of Implants with Various Area of Hydroxyapatite Coating Placed in the Rabbit Tibia)

  • 문상권;조규성;안세영;이훈;김한성;심준성;최성호
    • Journal of Periodontal and Implant Science
    • /
    • 제33권4호
    • /
    • pp.625-641
    • /
    • 2003
  • Background: This study presents a biomechanical and histometric comparison of bone response to implants with various area of hydroxyapatite(HA) coating. Methods: The implants were placed in the tibia of 10 rabbits weighing 2.5-3.5kg. The control group had a machined surface, the experimental group 1 had 50${\mu}m$ thick HA coated in a band form, and the experimental group 2 had 50${\mu}m$ thick HA coated on the entire surface. 8 weeks after implantation, the animals were sacrificed. Removal torque was measured and histologic preparation was also performed for histologic and histometric analysis. Bone to implant contact as well as percentage of bone area inside threads were measured. ANOVA post hoc, and t-test were used for statistical analysis with p-value p<0.05. Results: 1. The removal torques were 9.36${\pm}$5.64 Ncm, 48.40 ${\pm}$ 16.66 Ncm, and 82.37${\pm}$22.56 Ncm for the control, exp. 1, and exp. 2 group respectively. Statistically significant difference were found among all the groups(p<0.05). 2. Bone to implant contact in the cortical bone were 38.94${\pm}$10.9 %, 66.90${\pm}$14.1 %, 73.00${\pm}$19.4 %, in the marrow bone, 8.30${\pm}$5.4%, 14.59${\pm}$5.9%, 18.54${\pm}$11.8%, and in total, 22.40${\pm}$10.1%, 31,17${\pm}$7.5%, 41.41${\pm}$12.2% for the control, exp. 1, and exp. 2 group respectively . In the cortical bone, exp. 1, and exp. 2 group showed statistically significantly higher contact compared to control group. Total contact and in the marrow bone, only exp. 2 group showed statistically significantly higher contact compared to control group(p<0.05). In all the groups significantly higher contact were observed in the cortical bone compared to the marrow bone(p<0.05). 3. Percentage of bone area inside threads in the cortical bone were 55.68${\pm}$7.25%, 55.19${\pm}$13.19%, 57.04${\pm}$13.33%, in the marrow bone, 12.34${\pm}$14.61%, 17.56${\pm}$20.04%, 20.26${\pm}$12.83%, and in total, 30.30${\pm}$12.46%, 31.57 ${\pm}$15.15%, 34.25${\pm}$12.56% for the control, exp.1, and exp. 2 group respectively. There was no statistical difference among the groups. In all the groups significantly higher bone area were observed in the cortical bone compared to the marrow bone(p<0.05)

BCG 접종 후 발생한 화농성 림프절염 환자의 단핵구에서 Toll-like receptor 2의 발현 (Toll-like receptor 2 expression on monocytes from patients with BCG vaccine-associated suppurative lymphadenitis)

  • 오현주;신경수
    • Clinical and Experimental Pediatrics
    • /
    • 제52권6호
    • /
    • pp.667-673
    • /
    • 2009
  • 목 적 : TLR2는 숙주의 항결핵 방어면역의 중요한 역할을 하는 것으로 알려져 있다. 본 연구는 BCG 접종 후 발생한 화농성 림프절염 환자 단핵구에서 TLR2의 발현과 TLR2 리간드 자극에 의한 $TNF-{\alpha}$와 IL-6의 생성을 조사하여 화농성 림프절염 발병과 TLR2의 연관성을 알아보고자 하였다. 방 법 : BCG 접종 후 발생한 화농성 림프절염 환자 16명과 건강 대조군 10명의 말초 혈액에서 단핵구를 분리하고, TLR2 리간드인 Pam3CSK4로 자극한 후 유세포분석과 역전사중합효소반응을 이용하여 TLR2의 발현을 측정하였고, 자극 후 $TNF-{\alpha}$와 IL-6의 생성을 측정하여 TLR2의 발현 정도를 간접적으로 조사하였다. 결 과 : BCG 접종 후 발생한 화농성 림프절염 환자 단핵구의 TLR2 발현 정도($3.39{\pm}1.2%$)는 대조군($4.64{\pm}2.6%$)에 비하여 유의하게 감소하였고, 단핵구 자극에 의한 $TNF-{\alpha}$와 IL-6의 생성도 대조군($TNF-{\alpha}$, $1,098.5{\pm}94.3pg/mL$; IL-6, $6,696.3{\pm}544.3pg/mL$)에 비하여 환자군($TNF-{\alpha}$, $775.5{\pm}60.8pg/mL$; IL-6, $4,645.8{\pm}583.9pg/mL$)에서 유의하게 감소하였다. 그리고 자극 시간에 따른 TLR2 발현 정도와 $TNF-{\alpha}$와 IL-6의 생성 증가가 유사한 양상을 나타내었다. 결 론 : 본 연구의 결과에서 BCG 접종 후 발생한 화농성 림프절염 환자군 단핵구의 TLR2 발현 감소가 연관되어 있고, M. bovis BCG의 리간드 인식에 TLR2가 관여함을 추정할 수 있다.

벼 무경운 재배시 재배양식에 따른 생육 및 수량 (Rice Growth and Yield at Different Cultural Methods under No-tillage Condition)

  • 박홍규;김상수;백남현;석순종;박건호;이선용
    • 한국작물학회지
    • /
    • 제41권4호
    • /
    • pp.420-428
    • /
    • 1996
  • 획기적인 벼 생산비 절감 기술 확립을 위해1993~1995년 호남농업시험장인 전북통(미사질양토)에서 동진벼를 공시하고 무경운 기계이앙, 무경운 무논골뿌림, 무경운 표면조파, 무경운 산파, 경운 기계이앙 등 5가지로 하여 재배 양식간의 생육 및 수량성의 차이를 비교 검토한 결과는 다음과 같다. 1. 토양 경도는 무경운에서 높았고(토심 10cm의 경도 : 무경운 1.6kg/$cm^2$, 경운 1.0kg/$cm^2$), 토괴 심도가 깊을수록 경운과의 차이가 커지는 경향이었으며, 토양 물리성중 가비중은 무경운이 경운보다 높았으며 공극률은 경운에서 58.5~55.9로 무경운의 52.1~50.5보다 높았다. 2. 무경운 직파재배시 m$^2$당 입모수는 l13~133개였으며 이앙재배시 결주율은 경운 이앙 3%, 무경운 이앙 4.5%로 무경운 이앙에서 높았고, 유효경 비율은 경운 이앙이 높았으며, 무경운 재배 양식간에는 이앙>무논골뿌림>표면조파>산파의 순으로 높았다. 3. 잡초 발생량은 무경운에서 많았으며 경운에서는 피, 올양개, 방동사니가 우점하였고 무경운에서는 나도겨풀, 사마귀풀, 둑새풀이 우점하였 다. 4. 뿌리량은 경운 이앙에서 가장 많았고, 무경운재배 양식간에는 이앙>무논골뿌림>표면조파>산파의 순으로 많았으며, 뿌리 분포는 무경운에서 경운보다 표층 분포가 많았다. 특히 표면에 파종한 산파와 표면조파에서 표층 분포가많았다. 5. 하위 절간의 분포 비율은 도복이 심했던 무경운 표면조파와 산파에서 낮았고, 무경운 무논골뿌림, 무경운 이앙은 경운 이앙과 비슷하였으며, 중심고는 이앙재배에 비해 직파재배에서낮았고 줄기 매몰 심도는 경운(3.1cm)에 비해 무경운에서 낮았는데 무경운 표면조파, 산파에서는 0.6~0.7cm로 현저히 낮았다. 6. 도장 도복은 무경운재배시 산파>표면조파>무논골뿌림>이앙재배 순으로 높게 발생했으며, 특히 무경운 표면조파와 산파에서 뿌리도복이 심하게 발생되었다. 7. m$^2$당 수수는 경운 이아이 가장 많았고 무경운산파가 가장 적었으며, 등숙 비율은 포장도복이 심했던 무경운 표면조파, 산파에서 가장 낮았다. 벼 수량성은 경운, 무경운 이앙은 서로 비슷하였고 무경운 무논골뿌림은 경운 이앙의 약 93%였으며, 무경운 표면조파, 산파는 포장도복으로 크게 낮아 경운 이질의 87~81%정도였다.

  • PDF

안구내 악성종양에 대한 저준위 방사선요법에 관한 연구 (A study of Brachytherapy for Intraocular Tumor)

  • 지광수;유대헌;이성구;김재휴;지영훈
    • 대한방사선치료학회지
    • /
    • 제8권1호
    • /
    • pp.19-27
    • /
    • 1996
  • 연구의 목적 및 중요성 안구에 발생하는 악성종양의 치료에 일반적으로 사용되는 적출술이나 외부 방사선치료법은 시력상실 및 충분한 종양선량을 얻을 수 없는 단점이 있다. 최근 들어 기존치료법의 단점들을 줄이면서 치료 효과를 높이기 위한 치료법으로서 방사성동위원소가 삽입된 기구를 이용한 근접 방사선요법이 외국에서 개발되어 시행되고 있다. 본 연구에서는 안구내 악성종양의 새로운 치료법인 근접 방사성요법을 시행하기 위하여 접합한 형태의 기구를 개발하고, 기구에서 방출되는 방사선의 선량 및 선량분포측정을 통하여 종양 및 주변조직에 분포되는 선량을 보다 정확하게 계산해 보고자 하였다. 연구의 내용 및 범위 안구내 악성종양의 치료를 위한 근접 방사선요법의 연구를 위하여, 1. 안구의 모델을 결정하고, 적당한 방사성동위원소를 선택하였으며, 2. 적합한 형태의 기구를 설계 및 제작하고, 3. 제작된 기구의 방사선 투과계수 및 기구에서 방출되는 방사선의 선량분포를 측정하였으며, 4. 이들 측정 결과와 기존의 컴퓨터 선량계산모델들의 계산 결과와 비교하였다. 연구 결과 및 활용에 대한 건의 본 연구를 통해 다음과 같은 결과를 얻었다. 1. 안구의 모델은 지름 25mm인 구형으로 결정하였으며, 근접 치료에 사용될 방사성동위원소는 크기, 반감기, 발생 방사선의 에너지 및 구입의 용이성 등을 고려하여 Ir-192가 가장 적합한 것으로 판단되었다. 2. 기구는 인체 조직과의 생물학적 반응 및 피폭 선량 차폐를 고려하여 순금으로 제작하였으며, 기구의 크기는 지름이 15mm, 17mm 및 20mm인 3종류로 하였고, 두께는 모두 1.5mm로 하였다. 3. 기구의 방사선 투과계수를 TLD 및 Film으로 측정한 결과 표면에서 모두 0.71, 표면의 1.5mm거리에서 각각 0.45, 0.49이었다. 4. Ir-192가 삽입된 기구의 선량분포 측정 결과를 Gary Luxton 등의 컴퓨터 선량계산모델 및 원자력병원에서 보유하고 있는 방사선 치료계획장치인 CAP-PLAN의 선량계산모델의 계산 결과와 비교하여, 흡수선량은 ${\pm}10\%$ 이내에서 거리로는 0.4mm 이내에서 대부분 일치하였다. 최대 오차는 각각 $11.3\%$ 및 0.8mm로 나타났다. 이상의 결과들로부터 새로 개발한 금으로 된 기구와 Ir-192 seed를 이용한 근접 방사선 치료법으로 안구의 악성종양에 대한 치료를 보다 효과적으로 시행할 수 있을 것으로 기대된다.

  • PDF

Phellinus sp.의 분리 및 균사체의 액체배양 (Isolation and Mycelial Cultivation Submerged of Phellinus sp.)

  • 강태수;이동기;이신영
    • 한국균학회지
    • /
    • 제25권4호통권83호
    • /
    • pp.257-267
    • /
    • 1997
  • 강원도 양양군 일원 야산의 뽕나무에서 자생하고 있는 상황버섯 형태의 자실체를 채집하고, 그 자실체로부터 Phellnus속의 한 균주를 분리동정하였으며, 액체배양에 의하여 분리 균사체의 대량생산을 위한 배양조건, 배지조성 및 배양장치의 영향을 조사하였다. 자실체는 표면이 검으며 거칠고, 갓의 안쪽은 황갈색으로 평평하였으며, 자실층이 두터웠고(5-7 cm), 말굽형으로 조직이 매우 단단하여 전형적인 상황버섯의 형태를 나타내었다. 또, 조직 일부를 water agar에 이식하여 순수분리한 결과, 분리된 균사체는 황갈색으로, PDA 평판배지에서 자갈색의 색소를 분비하였으며, 균사는 clamp connection을 형성하지 않았고, 많은 branch가 있었다. 또 laccase, tyrosinase 및 peroxidase activity를 가지고 있어, 본 균주는 Phellinus속의 한 균주로 확인되었다. 플라스크 배양에서 균사체 생성을 위한 최적배양조건은 접종비 5%(v/v), 배지액량 70 mL, 교반속도 150rpm, 초기 pH 6, 배양온도 $30^{\circ}C$ 및 배양기간은 8일이었다. 또, 반응표면분석에 의한 최적 배지조성은 glucose 12.12 g/L, sucrose 12.12 g/L, yeast extract 11.15 g/L, malt extract 11.15 g/L, $KH_2PO_4$ 0.855 g/L 및 $CaCl_2$ 0.855 g/L 이었으며, 배양 4일 및 8일 후 균사체량은 각각 1.95 및 9.89 g/L 이었고, 최대 비생육속도 $0.020\;hr^{-1}$, 생산성은 1.25 g/L/day이었다. 그러나 서로 다른 3종의 배양장치를 사용한 결과, 3 L air-lift fermentor에서 통기량 2.5 vvm으로 4일간 배양하였을 때, 약 7.5g/L의 균사체를 얻을 수 있었으며, 이때, 최대 비증식속도는 $0.033\;hr^{-1}$, 생산성은 1.9g/L/day로, 같은 기간내 플라스크 배양시 보다 각각 1.7 및 4.2배가 향상된 결과를 얻을 수 있었다.

  • PDF

유역(流域) 물 수지(收支)의 회귀모형화(回歸模型化) (Regression Modeling of Water-balance in Watershed)

  • 김태철
    • 농업과학연구
    • /
    • 제10권2호
    • /
    • pp.324-333
    • /
    • 1983
  • 장기유출해석(長期流出解析) 모형(模型)은 물수지(收支)에 그 기반(基盤)을 두고 있다. 하천(河川) 유출량(流出量)의 물수지(收支)를 강우량(降雨量), 증발산량(蒸發散量), 토양수분변화량(土壤水分變化量)으로 단순화(單純化)하여, 이를 강우량(降雨量)pan증발량(蒸發量), 전기유출량(前期流出量)의 변수(變數)로 회귀모형화(回歸模型化)하여 회귀계수(回歸係數)로 부터 다음과 같은 유역(流域) 수문반응(水文反應)의 일반화(一般化) 경향(傾向)을 모색하였다. 이들 회귀계수(回歸係數), $b_1$, $b_2$, $b_3$로부터 개괄적(槪括的), 정성적(定性的), 연역적(演譯的)으로 유역(流域)의 수문반응(水文反應)을 해석(解析)할 수 있었다. 물수지(收支) 회귀모형(回歸模型)의 특성(特性)은 다음과 같다. 1. 회귀계수(回歸係數) $b_1$은 강우중(降雨中)에서 차단(遮斷), 지표저류량(地表貯溜量) 및 하도손실(河道損失)을 뺀 직접유출성분(直接流出成分)으로, 수계별(水系別)로 하류지점(下流地點), 유역면적(流域面積)이 커짐에 따라 $b_1$값은 작아진다. 2. 회귀계수(回歸係數) $b_2$는 토양수분변화에 따른 유출 체(滯)를 나타내는 기저유출(基底流出)의 Index로 유역면적(流域面積)이 커지고 유역평균경사(流域平均傾斜)가 완만할수록 유역(流域)의 저류능(貯溜能)이 커지므로 $b_2$값도 커진다. 3. 회귀계수(回歸係數) $b_3$는 토양수분과 토양피복상태에 따른 유역증발산(流域蒸發散)에 의(依)한 손실(損失)을 나타내어 부치(負値)를 가지며 하류지점(下流地點), 유역면적(流域面積)이 커짐에 따라 지표(地表), 지하저류능(地下貯溜能)이 커지므로 $b_3$값도 커진다. 4. 강우일수(降雨日數)가 많은 달은 대체로 Pan증발량(蒸發量)이 적으므로 큰 유출(流出)이 발생(發生)하여 전(前)달의 유출(流出)이 많았으면 그 달에 강우(降雨)가 없어도 기저유출(基底流出)이 나타내는 등(等) 유출(流出)의 계절적변화를 해석(解析)할 수 있다. 5. 월(月) 유출(流出)에 대한 강우량(降雨量), 증발산량(蒸發散量) 토양수분변화(土壤水分變化)의 상대적(相對的) 기여도(寄與度)는 ${\beta}$ Coeff.의 백분율(百分率)로 나타내면 각각(各各) 80%, 11%, 9%이다.

  • PDF

백두산 화산의 전조활동 분석 연구 (Analysis of Unrest Signs of Activity at the Baegdusan Volcano)

  • 윤성효;이정현
    • 암석학회지
    • /
    • 제21권1호
    • /
    • pp.1-12
    • /
    • 2012
  • 우리 민족의 영산인 백두산은 동북아시아 지역에서 가장 활동적인 화산의 하나이며, 10세기 대분화는 지난 2,000년 이내에서 가장 격렬한 화산활동이었다. 백두산 천지 일원에서는 2002년에서 2005년까지 지하 마그마의 관입에 의한 화산성 지진의 급증 및 비정상적인 지표 변형이 발생하였다. 화산구조성 지진의 규모가 2002년 7월부터 갑자기 급증하였으며, 지진발생 빈도도 한 달에 수십 회에서 수백 회로 증가하였으며, 2002-2003년도에는 하루에 백 여 회의 군발(群發)지진이 발생하였으며, 2003년에는 연간 2,100여 회 발생하였고, 2006년도부터는 감소하는 추세를 보여 현재에는 1999년-2001년의 수준을 유지하고 있다. 주파수가 대체로 5 Hz 또는 5-10 Hz의 범위에 속하는 이러한 지진들은 B-형 화산구조성 지진(VT-B)과 장주기 지진(LP)으로 지하 3~5 km 천부에 위치한 마그마방 상부의 균열과 마그마의 관입에 기인하는 것이다. 2002년도부터 2009년도까지의 GPS관측에 의한 지표면의 수평변위에 의하면 2002년 이후 천지 칼데라 정상부를 중심으로 화산체가 팽창하는 것이 감지되었으며, 2002년도 대비 2003년도에는 약 4 cm 이상이었고 2003년도 이후에 그 변화율은 감소하는 경향으로 보였다. 백두산 성층화산체 사면에서의 정밀수준 측량에 의한 지표면의 수직적 팽창 또한 최대 10 cm 이상의 변위를 보였으며, 수직 변위와 수평 변위 모두 2006년도 이후 변화율은 다소 감소하는 추세를 보이나, 여전히 불안정한 상태를 보이고 있다. 온천에서 채취한 화산가스로부터 분석된 헬륨 동위원소비($^3He/^4He$)의 높은 값은 이들 가스들이 맨틀로부터 유래된 것임을 증명하고 있다. 천지 주변의 온천수의 온도가 $69^{\circ}C$에서 점진적으로 증가하여 최대 $83^{\circ}C$에 이르고 있다. 그간 비교적 큰 규모의 지진에 의한 산사태, 암벽붕괴, 화산가스에 의한 나무의 고사 등이 관찰되었고, 올해 여름 천지 칼데라 외륜산의 절벽으로부터 수차례의 암벽붕괴도 발생하였다. 이런 모든 현상들이 백두산 천지화산이 불안정한 상태에 있으며, 잠재적으로는 충분하게 분화 가능성이 있다는 것을 지시하는 것이다. 강력한 화산 감시 모니터링과 화산재해 경감을 위한 사전 방재대책이 필요한 단계라고 평가된다.