• 제목/요약/키워드: Surface decontamination

검색결과 141건 처리시간 0.028초

원자로 냉각재 펌프용 STS 304와 STS 415의 초음파-화학제염 공정 시 부식 손상 거동 (Corrosion Damage Behavior of STS 304 and STS 415 for Reactor Coolant Pump during Ultrasonic-Chemical Decontamination Process)

  • 현광룡;박재철;한민수;김성종
    • 한국표면공학회지
    • /
    • 제51권4호
    • /
    • pp.218-223
    • /
    • 2018
  • In this study, we proposed a new ultrasonic-chemical decontamination process for decontaminating radioactive corrosion products during the maintenance of reactor coolant pump (RCP). The actual decontamination process was reproduced in the laboratory. And the corrosion characteristics of stainless steel (STS), constituting the RCP interior parts, were examined. The weight-loss measurment and polarization experiment were carried out in order to determine the corrosion characteristics of STS 304 and STS 415 by repeated decontamination processes. The STS 304 presented a little corrosion damage, which was almost indistinguishable from visual observation. The weight-loss rate of STS 304 was also significantly lower. On the other hand, STS 415 showed severe corrosion damage on its surface, greater weight-loss rate and higher corrosion current density than STS 304.

Surface removal of stainless steel using a single-mode continuous wave fiber laser to decontaminate primary circuits

  • Song, Ki-Hee;Shin, Jae Sung
    • Nuclear Engineering and Technology
    • /
    • 제54권9호
    • /
    • pp.3293-3298
    • /
    • 2022
  • Removing radioactive contaminated metal materials is a vital task during the decommissioning of nuclear power plants to reduce the cost of the post-dismantling process. The laser decontamination technique has been recognized as a key tool for a successful dismantling process as it enables a remote operation in radioactive facilities. It also minimizes exposure of workers to hazardous materials and reduces secondary waste, increasing the environmental friendless of the post-dismantling processing. In this work, we present a thorough and efficient laser decontamination approach using a single-mode continuous-wave (CW) laser. We subjected stainless steels to a surface-removal process that repetitively exposes the laser to a confined region of ~75 ㎛ at a high scanning rate of 10 m/s. We evaluate the decontamination performance by measuring the removal depth with a 3D scanning microscope and further investigate optimal removal conditions given practical parameters such as the laser power and scan properties. We successfully removed the metal surface to a depth of more than 40 ㎛ with laser power of 300 W and ten scans, showing the potential to achieve an extremely high DF more than 1000 by simply increasing the number of scans and the laser power for the decontamination of primary circuits.

201Tl의 생산과정에서 발생한 방사성 폐기물의 제염 효율 평가 (Evaluation of the Decontamination Efficiency of Radioactive Wastes Generated during the Production of 201Tl)

  • 허재승;김상록;김기섭;안윤진;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권5호
    • /
    • pp.481-487
    • /
    • 2021
  • This study was conducted for the purpose of efficient radioactive waste disposal and management. Experiment was evaluated the decontamination efficiencies of the four types decontamination materials(Water, Alcohol, Decontamination Water, Decontamination Gel) with radioactive wastes generated during radio-pharmaceutical production process at Korea Institute Radiological and Medical Sciences(KIRAMS). The radioactive waste sample used in experiment is a lead plate of the fume hood that was disposed in April, 2019. In the experimental method, radioactive waste was measured before and after decontamination using a HPGe semiconductor detector and Gamma survey meter. The measured values before and after decontamination were evaluated for decontamination efficiency as a percentage. As a result, it was confirmed that a lot of specific activity and surface dose rate was removed from the radioactive wastes. In particular, when decontamination water was used, most of the radioactivity of radioactive wastes was removed. Considering these results, if decontamination water is used in decontamination of radioactive waste, decontamination efficiency equivalent to the disposition criteria can be expected with just one decontamination treatment. In addition, in the case of water and alcohol, only on decontamination was effective in approximately 75% and 95%. Otherwise, when decontamination gel was used, it was confirmed that the largest deviation occurred among all experimental results.

TRIGA 연구로 해체 시 발생하는 덕트 폐기물의 제염 (Decontamination of Duct Waste Arising from the Decommissioning of TRIGA Research Reactor)

  • 최왕규;이근우;정경환;오원진;박진호
    • 한국방사성폐기물학회:학술대회논문집
    • /
    • 한국방사성폐기물학회 2003년도 가을 학술논문집
    • /
    • pp.720-724
    • /
    • 2003
  • 국내의 가동중지 된 TRIGA 연구로의 해체 시 발생하는 다양한 덕트 폐기물의 자체처분을 위한 제염 공정을 개발할 목적으로 TRIGA 연구로에서 직접 인출한 덕트 시편을 대상으로 오염물의 성상을 조사하였고, 이를 통해 적절한 제염공정을 선정하였다 페인트 도막이 입혀진 덕트 내부계통 표면은 주로 Co-60과 Cs-137로 오염이 되어 있었으며, 이들 핵종은 페인트 층 내부뿐만 아니라 덕트 재료인 함석 표면의 아연 도금막까지 침투되어 있음을 알 수 있었다. 이들 표면 오염을 제거하기 위한 공정으로 NaOH와 황산을 교대로 사용하는 두 단계의 화학제염을 제시하였으며, 이들 제염제를 사용하는 제염공정의 적용을 통해 덕트 폐기물을 효과적으로 제염할 수 있었다.

  • PDF

원자로 냉각재 펌프용 재료의 화학 제염 공정 시 적용 가능성 평가 (Evaluation of application possibility in chemical decontamination of materials for reactor coolant pump)

  • 김정일;김기준;김성종
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권1호
    • /
    • pp.84-94
    • /
    • 2007
  • As a reactor coolant pump(RCP) is operated in the nuclear power system for a long time. so its surface is continuously contaminated by radioactive scales. In order to perform regular or emergency repair about RCP internals a special decontamination process should be used to reduce the radiation from the RCP surface by means of chemical cleaning. In this study, applicable possibility in chemical decontamination for RCP was investigated on the various materials. The STS 304 showed the best electrochemical properties for corrosion resistance than other materials. However, the pitting corrosion was slightly generated in both STS 415 and STS 431 with the increasing numbers of cycle and intergranular corrosion were sporadically observed. The size of their pitting corrosion and intergranular corrosion were also increased with increasing cycle numbers.

The efficacy of different implant surface decontamination methods using spectrophotometric analysis: an in vitro study

  • Roberto Giffi;Davide Pietropaoli;Leonardo Mancini;Francesco Tarallo;Philipp Sahrmann;Enrico Marchetti
    • Journal of Periodontal and Implant Science
    • /
    • 제53권4호
    • /
    • pp.295-305
    • /
    • 2023
  • Purpose: Various methods have been proposed to achieve the nearly complete decontamination of the surface of implants affected by peri-implantitis. We investigated the in vitro debridement efficiency of multiple decontamination methods (Gracey curettes [GC], glycine air-polishing [G-Air], erythritol air-polishing [E-Air] and titanium brushes [TiB]) using a novel spectrophotometric ink-model in 3 different bone defect settings (30°, 60°, and 90°). Methods: Forty-five dental implants were stained with indelible ink and mounted in resin models, which simulated standardised peri-implantitis defects with different bone defect angulations (30°, 60°, and 90°). After each run of instrumentation, the implants were removed from the resin model, and the ink was dissolved in ethanol (97%). A spectrophotometric analysis was performed to detect colour remnants in order to measure the cumulative uncleaned surface area of the implants. Scanning electron microscopy images were taken to assess micromorphological surface changes. Results: Generally, the 60° bone defects were the easiest to debride, and the 30° defects were the most difficult (ink absorption peak: 0.26±0.04 for 60° defects; 0.32±0.06 for 30° defects; 0.27±0.04 for 90° defects). The most effective debridement method was TiB, independently of the bone defect type (TiB vs. GC: P<0.0001; TiB vs. G-Air: P=0.0017; TiB vs. GE-Air: P=0.0007). GE-Air appeared to be the least efficient method for biofilm debridement. Conclusions: T-brushes seem to be a promising decontamination method compared to the other techniques, whereas G-Air was less aggressive on the implant surface. The use of a spectrophotometric model was shown to be a novel but promising assessment method for in vitro ink studies.

흙의 자체정화능력을 이용한 오염된 토양정화 (Application of Soil's Self-Decontamination Ability to Contaminated Ground)

  • 정진섭;정정권;김태형
    • 한국물환경학회지
    • /
    • 제22권4호
    • /
    • pp.632-638
    • /
    • 2006
  • 최근에 오염된 토양을 정화하기 위해서 다양한 방법들이 사용되고 있으나 이들 대부분은 이미 오염된 토양에 대한 정화기술로서 많은 비용이 수반되는 단점이 있다. 본 연구에서는 이들 방법과는 달리 잠재적인 토양오염지역에서 오염되기 전이나 혹은 진행 중일 때 지형학적인 특징, 지표 위나 아래의 배수시스템의 재배열 및 선행계획을 통해 토양자체의 정화능력을 이용하는 새로운 정화방법을 고찰하였다. 즉, 토양자체 정화과정이 왜, 어떻게 발전되는가에 대해 단계적으로 규명하였다. 해안지역에서 오염된 바닷물의 침투와 거주지역에서 유해 라돈가스($^{222}Rn$)의 조절 및 제거 등 두 가지 사례를 통해 흙의 자체정화 능력을 이용한 토양정화방법의 효율성을 평가하였다.

The effects of physical decontamination methods on zirconia implant surfaces: a systematic review

  • Tan, Nathan Chiang Ping;Khan, Ahsen;Antunes, Elsa;Miller, Catherine M;Sharma, Dileep
    • Journal of Periodontal and Implant Science
    • /
    • 제51권5호
    • /
    • pp.298-315
    • /
    • 2021
  • Purpose: Peri-implantitis therapy and implant maintenance are fundamental practices to enhance the longevity of zirconia implants. However, the use of physical decontamination methods, including hand instruments, polishing devices, ultrasonic scalers, and laser systems, might damage the implant surfaces. The aim of this systematic review was to evaluate the effects of physical decontamination methods on zirconia implant surfaces. Methods: A systematic search was conducted using 5 electronic databases: Ovid MEDLINE, PubMed, Scopus, Web of Science, and Cochrane. Hand searching of the OpenGrey database, reference lists, and 6 selected dental journals was also performed to identify relevant studies satisfying the eligibility criteria. Results: Overall, 1049 unique studies were identified, of which 11 studies were deemed suitable for final review. Air-abrasive devices with glycine powder, prophylaxis cups, and ultrasonic scalers with non-metal tips were found to cause minimal to no damage to implantgrade zirconia surfaces. However, hand instruments and ultrasonic scalers with metal tips have the potential to cause major damage to zirconia surfaces. In terms of laser systems, diode lasers appear to be the most promising, as no surface alterations were reported following their use. Conclusion: Air-abrasive devices and prophylaxis cups are safe for zirconia implant decontamination due to preservation of the implant surface integrity. In contrast, hand instruments and ultrasonic scalers with metal tips should be used with caution. Recommendations for the use of laser systems could not be fully established due to significant heterogeneity among included studies, but diode lasers may be the best-suited system. Further research-specifically, randomised controlled trials-would further confirm the effects of physical decontamination methods in a clinical setting.

금속 시편 형태에 따른 PEC 초음파 제염 성능 (PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens)

  • 원휘준;김계남;정종헌;박진호;오원진
    • 방사성폐기물학회지
    • /
    • 제3권4호
    • /
    • pp.293-300
    • /
    • 2005
  • Type 304 stainless steel 시편에 느슨하게 붙어있는 $Eu_2O_3$ 분말에 대한 초음파 제염 거동을 조사하였다. 매질을 물, PFC 및 $0.1\;vol\%$의 음이온 계면활성제를 함유한 PFC 용액으로 변화시킴에 따라 제염계수는 20, 50 및 200으로 증가하였다. 제염계수에 차이가 생기는 이유를 초음파 매질의 표면장력 및 양으로 하전된 산화물 표면과 음이온 계면활성제 사이의 상호작용에 기인한 것으로 설명할 수 있었다. 음이온 계면활성제를 함유한 PFC 용액 내에서 $Eu_2O_3$ 분말로 오염된 평면 시편, 파이프 시편, 틈새 시편 및 용접 시편에 대한 초음파 제염 효과를 관찰하였다. 연구된 모든 시편에 대해, 대부분의 오염물이 완벽하게 제거되는 것으로 나타났다. 길이가 6cm인 파이프 시편에 대해서는 오염물의 $98.5\%$가 제거되었다.

  • PDF

수질오염 제염을 위한 세슘 선택성 상자성 코어 무기복합제염제 개발 (Development of Cesium-selective Paramagnetic Core Inorganic Composite Agent for Water Decontamination)

  • 홍성표;강보선
    • 방사선산업학회지
    • /
    • 제18권2호
    • /
    • pp.127-132
    • /
    • 2024
  • Large amounts of liquid radioactive waste or radioactive contaminated water could be produced during the treatment of radiation accidents or during the dismantling and decontamination process of nuclear power plants. Since most of the decontamination agents to date are difficult to recover after adsorption of radioactive isotopes, their use in open environments such as rivers, reservoirs, or oceans is limited. In this study, as a radioactive decontamination agent that can overcome the current limitations when used in an open environment, a paramagnetic core inorganic composite (PMCIC) decomposite agent with high selectivity to cesium ions was developed. PMCore was prepared by synthesizing paramagnetic iron oxide nanoparticles, and inorganic crystals such as metal-ferrocyanide were conjugated to the surface so that PMCore could be selective to cesium ions. The developed PMCIC could be easily recovered from the water by magnetism and could adsorb up to 94 μM of Cs atoms per 1 g of PMCIC.