Experimental Study of Condensation Heat Transfer in Pre-heating Exchanger to the Type of Hydrophilic Surface Treatment (친수 표면처리 종류에 따른 공기 예열 열교환기의 응축 열전달 실험적 연구)

  • Seok, Sungchul;Chung, Tae-Yong;Chin, Donghoon;Hwang, Seungsik;Choi, Gyuhong;Park, Jaewon
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.237-238
    • /
    • 2012
  • Recently, an energy-saving due to the energy utilisation efficiency enhancement is important. In order to improve the heat efficiency of the general residential boiler, We performed an experiment of condensation heat transfer to air pre-heat exchanger adhered to the condensing boiler. In this research, We analyze the heat transfer performance through the hydrophilic surface treatment(plasma, etching). The results of the research, On plasma and etching treated surface, Overall heat transfer coefficient is displayed the tendency to increase.

  • PDF

The Effect of Water Contact Angles of the Fin Surfaces of the Fin-and-Tube Heat Exchangers on the Water Hold-up (핀-관 열교환기에서의 핀의 물 접촉각이 응축잔수량에 미치는 영향)

  • 신종민;이남교;한성주;하삼철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.6
    • /
    • pp.490-496
    • /
    • 2001
  • An experimental study on the behavior of the water hold-up by condensation of a fin-and-tube heat exchanger with regard to the surface characteristics, i.e., contact angle, was conducted. The static and dynamic contact angles were measured, and condensation experiments were conducted. Flow patterns on the fins with different surface characteristics were visualized. Results showed that the static contact angle is proportional to the dynamic contact angle within the range of this study. The water hold-up of the heat exchanger increases as the static or dynamic contact angle of its surfaces increases. Existence of transition of flow patterns was found as the static or dynamic angle increase. Due to the transition in the flow patterns, changes in the gradient of the water hold-up is occurred around the static angle of 8$0^{\circ}C$.

  • PDF

Changes in Water Content Affect the Post-Milling Quality of Paddy Rice Stored at Low Temperature

  • Kim, Young-Keun;Hong, Seong-Gi;Lee, Sun-Ho;Park, Jong-Ryul;Choe, Jung-Seob
    • Journal of Biosystems Engineering
    • /
    • v.39 no.4
    • /
    • pp.336-344
    • /
    • 2014
  • Purpose: In this study, the effect of milling on paddy rice stored at low temperature, the changes in grain temperature of bulk storage bags exposed at room temperature, the post-milling water content of paddy rice, the whiteness of rice, and the rate of pest incidence were investigated and data were analyzed. Methods: Changes in temperature inside the bulk storage bags kept at low temperature and grain temperature after exposure to room temperature were measured. Experiments were conducted for identifying the reasons of post-milling quality changes in paddy rice stored at low temperature. Results: It was determined that a short-term increase of water content in paddy rice was directly related to surface condensation, and that rice should be milled at least 72 h after removal from low-temperature storage, in order to completely eliminate surface condensation of paddy rice kept in bulk storage bags. It was observed that post-milling quality of rice changed, but water content was maintained at high levels for more than 18 d in rice that was milled when condensation occurred, regardless of paper or vinyl packaging. Rice whiteness rapidly decreased in rice that was milled when condensation occurred, regardless of packaging, while rice that was milled 72 h or more after removal from low temperature storage did not show any significant changes in whiteness. No pest incidence was observed up to 12 d after removal from low temperature storage, regardless of packaging. Starting at 18 d, after removal from low temperature storage, rice that was milled when condensation occurred, was affected by pests, while 24 d after removal from low temperature storage, all portions of rice were affected by pests. Conclusions: Our results suggest that changes in post-milling quality of rice could be significantly reduced by exposing paddy rice to room temperature for at least 72 h before milling, in order to allow the increase of grain temperature and prevent surface condensation.

AN EXPERIMENTAL STUDY ON PENETRATION OF DYE IN COMPOSITE RESIN (수종(數種) Composite Resin의 색소침투(色素浸透)에 관(關)한 실험적(實驗的) 연구(硏究))

  • Lee, Myung-Chong
    • Restorative Dentistry and Endodontics
    • /
    • v.12 no.1
    • /
    • pp.155-163
    • /
    • 1986
  • The purpose of this study was to measure penetration of dye stuff (2% Methylene blue, 2% Hematoxylin, 2% crystal violet and 2% safranin-O) on unfilled resin (Lang Dental MFG Co.) Hipol (Boopyung Dental Chemical Co. Macrocomposite resin) Durafill (Kulzer, Co. Microfilled Composite resin) and Heliosit (Vivadent Co. Microfilled Composite resin) The unfilled resin with dough stage was inserted into plastic tuble (5mm in diameter and 4mm in height) with condensation force of 1000 gr, 2000 gr and without condensation force. Hipol mixed on the mixed pad was inserted into the plastic tube by the same method as the unfilled resin. The microfilled resins which were Durafill and Heliosit were polymerized for 60 seconds with the visible light on each surface of the plastic tube which was upper and lower, under condensation force of 1000 gr, 2000 gr and without condensation force. All specimens were stored in the air for 24 hours, then specimens were immersed in the various kind of dye solution for different period of time (1 hour and 24 hours). These dye-treated specimens were polished horizontally until removing 0.5mm of each surface on the emery paper (#1000), and the dye penetration in the polished surface was measured under the digital microscope (Japan Fosuh). Following results were obtained 1. The penetration of dyes was the most excessive in Durafill and was not influenced on the condensation force and the period of immersion time. 2. All dyes were penetrated into Hipol, and Crystal violet was penetrated most excessively in all dyes. 3. The penetration of dye in all resins was not influenced by the period of immersion time and condensation force. 4. There was no evidence of dye penetration in unfilled resin.

  • PDF

Condensing Characteristics of Pin-finned Surfaces on Pool Boiling in FC-72 (풀비등에서 소형 사각기둥핀 배열형상에 따른 FC-72의 응축특성)

  • Karng, Sarng-Woo;Kim, Seo-Young
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.7
    • /
    • pp.498-504
    • /
    • 2011
  • As the electronic industry rapidly develops, the heat flux from state-of-the-art electronics increases up to $10^6\;W/m^2$. For this reason, the development of a new cooling technology for high heat flux applications is strongly required. Recently, some cooling technologies using boiling and condensation of working fluid are being adopted to overcome such a technical barrier. In the present study, a smooth boiling surface ($14{\times}14\;mm^2$) was immersed in FC-72 and its vapor was condensed by four different types of condensation surfaces ($30{\times}30\;mm^2$ base). The condensing surfaces were composed of a smooth surface and $1{\times}1\;mm^2$ pin-finned surfaces of 2 mm height with 0.3, 0.5 and 1 mm array spacing. Boiling and condensing characteristics were investigated in detail on their combinations of boiling and condensing surfaces. For a smooth boiling surface the results obtained showed that the pin-finned condensing surface with 1 mm array spacing yielded the best performance and the smooth condensation surface did the worst. Furthermore hysteresis phenomena could be reduced by using enhanced condensing surfaces.

A Study on the condensate Retention at Horizontal Integral-Fin tubes (낮은 핀을 가진 수평관의 응축액 억류에 관한 연구)

  • 한규일;조동현
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.1
    • /
    • pp.151-165
    • /
    • 1996
  • Relation between condensate retention and heat transfer performance is studied for condensation of CFC-11 on horizontal integral-fin tubes. Eight tubes with trapezoidally shaped integral fin density from 738fpm to 1654fpm and 10, 30 grooves are tested. The liquid retention angles are measured by the height gauge, and each tube is tested under static(non-condensing) condition (CFC-11, water) and under dynamic(condensing) condition (CFC-11). The analytical model predicts the amount of liquid retention on a horizontal integral-fin tubes within+10 percent over most of the data. Average retention angle increases as both surface tension-to-density ratio($\sigma/\rho$) and fin density(fpm) increase, The tube having a fin density of 1299~1654fpm has the best heat transfer performance. The amount of surface flooding must keep below of 40 percent for best heat transfer performance at condensation. The tube having low number of fin density must be used for fluids having high values of $\sigma/\rho$(water, (TEX)$NH_3$, ect.) and the tube having high number of fin density must be used for the fluid having low values of $\sigma/\rho$(R-11, R-22, etc.)

  • PDF

Development of Prediction Models of Dressroom Surface Condensation - A nodal network model and a data-driven model - (드레스룸 표면 결로 발생 예측 모델 개발 - 노달 모델과 데이터 기반 모델 -)

  • Ju, Eun Ji;Lee, June Hae;Park, Cheol-Soo;Yeo, Myoung Souk
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.36 no.3
    • /
    • pp.169-176
    • /
    • 2020
  • The authors developed a nodal network model that simulates the flow of moist air and the thermal behavior of a target area. The nodal network model was enhanced using a parameter estimation technique based on the measured temperature, humidity, and schedule data. However, the nodal model is not good enough for predicting humidity of the target space, having 55.6% of CVRMSE. It is because re-evaporation effect could not be modeled due to uncertain factors in the field measurement. Hence, a data-driven model was introduced using an artificial neural network (ANN). It was found that the data-driven model is suitable for predicting the condensation compared to the nodal model satisfying ASHRAE Guideline with 3.36% of CVRMSE for temprature, relative humidity, and surface temperature on average. The model will be embedded in automated devices for real-time predictive control, to minimize the risk of surface condensation at dressroom in an apartment housing.

Improvement of Condensation Performance in Corridor Type Apartment Door

  • Lee, Sungbok;Hwang, Hajin
    • Architectural research
    • /
    • v.10 no.1
    • /
    • pp.33-39
    • /
    • 2008
  • Condensation has mainly occurred in corridor type apartment door which is exposed to the outside air and is made of steel, which has high thermal conductivity. As a result, the total costs of repair have increased with the number of disputes with residents. In this study, therefore, we investigate materials and construction methods used in apartment door, perform a computer simulation to find out possible improvements, and then suggest the dew point to prevent the occurrence of condensation throughout simulation. The results indicate that the temperature that condensation does not occur is $15.4^{\circ}C$, and the optimum method of achieving this dew point is shown to be a door frame system including a large vertical slot to decrease the area of thermal conduction between the outer and inner portions of the door frame. Mock-up tests show that the surface temperature of the door frame was higher than the dew point, and the system can withstand severe cold conditions of $-20^{\circ}C$. In application test, the surface temperature of door frame with vertical slots is $5.9^{\circ}C$in average, which is higher than the existing door frame. Furthermore, in the temperature distribution of the surrounding door measured with infrared ray camera, the existing door shows the high temperature distribution indicating lack of insulation, but the improved door shows the low temperature distribution indicating higher insulation.

An Experimental Study on the Application of Polypropylene Capillary Tube Cooling System (폴리프로필렌 모세유관 냉방시스템의 적용에 관한 실험적 연구)

  • Lee Young-Ju;Jin Wu-feng;Yeo Myoung-Souk;Kim Kwang-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.9
    • /
    • pp.873-881
    • /
    • 2005
  • In this study, we made RFC, RCC and NCC according to the method by which polypropylene capillary tube was adopted, and evaluated cooling performance of each system through model experiments. We also investigated an applicability of the combined use of radiant cooling and dehumidification system. The results are as follows: In case of normal cooling load, RFC and RCC maintained set temperature without a condensation. But, in case of peak cooling load, RFC and RCC resulted in the lack of cooling performance and caused a condensation at the radiation surface. Consequently, the only use of polypropylene capillary tube is considered not to be enough for cooling in real application. Using the combination of a dehumidification and radiant cooling system maintained the set temperature without a condensation. NCC kept the set temperature at anytime without a condensation. It is more economic than packaged air-conditioner system due to the cooling effect of the floor surface.

A Study on the Prediction Method of Condensation on the Curtain Wall of the High-rise Apartment Unit (초고층 아파트의 커튼월 결로 예측 방법에 관한 연구)

  • Im, Jeong-Hui
    • Journal of the Korea Construction Safety Engineering Association
    • /
    • s.41
    • /
    • pp.88-101
    • /
    • 2007
  • Recently, the condensation of walls often occurring in domestic high-rise apartment buildings is an important problem. The main purpose of this study is to develop the prediction method for the surface condensation on curtain wall in high-rise apartment buildings. Therefore, in this study, we first analyzed exterior climate factors through the analysis of the Seoul climate data and predicted the change of indoor temperature by using Apache program to find the cause of the condensation state and to prevent condensation. Also, according to this result, exterior climate factors and interior factors, which caused the condensation, was examined. The thermal performance of the curtain wall and the range of potential condensation were analyzed to focus on high-rise apartment buildings through computer simulation programs. The results are as $follows;^1$) The frame edge of curtain wall has a higher U-value than in the center by $30%^2$) Because of stack effect, the rooms on the higher floor have a lower external ventilation rate resulting to a higher relative humidity3) Installing a ventilation system($20m^3$/h. person) makes it possible to have a higher external ventilation rate, resulting to a lower relative humidity.

  • PDF