• Title/Summary/Keyword: Surface Water Temperature

Search Result 2,819, Processing Time 0.026 seconds

An Experimental Study on the Measurement of Water Surface Discharge Temperature of High-Temperature Bubble Injected into Cylindrical Acrylic Water Tank (원통 아크릴 수조로 주입된 고온 기포의 수면 배출 온도 측정에 관한 실험적 연구)

  • SeokTae Yoon;YongJin Cho
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.6
    • /
    • pp.99-105
    • /
    • 2023
  • Submarines, which require a high degree of survivability, are among the most critical combat weapon systems in military strategic assets. Conventional submarines need air to operate their propulsion systems. Exhaust gases released into the water during snorkel navigation heat the surrounding fluid, producing a temperature wake. This wake, in turn, reduces the submarine's survivability. In this study, we conducted a preliminary experiment on the temperature traces formed by an underwater submarine's waste discharge. For this purpose, we collected propulsion system and navigation condition data from domestically introduced submarines and developed an experimental system to measure the temperature traces. As a result, we observed that high-temperature bubbles injected into the tank broke down into smaller sizes, and their temperature dropped to levels similar to the surrounding fluid. This observation was confirmed using a thermocouple sensor. Consequently, the thermal imaging system designed to measure the temperature trace of the water's surface did not detect any significant temperature traces.

Passive Microwave Remote Sensing of Snow, Soil Moisture, Surface Temperature and Rain

  • Koike, Toshio;Fujii, Hideyuki
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.319-322
    • /
    • 1999
  • Land surface hydrological conditions have been considered to play an important role in the global and regional climate variability. Especially, snow, soil moisture, surface temperature, vegetation and rain are the key parameters which should be observed in the global scale. In this paper, new algorithms for these land surface hydrological parameters have been developed by introducing frequency and polarization dependencies of these parameters in the microwave radiative-transfer equations. The algorithms were applied to the TRMM Microwave Radiometer. (TMI) and validated by using the ground data obtained in the Tibetan Plateau. The estimated snow, soil moisture, surface temperature, water content of vegetation and rain patterns corresponded reasonably to the observed ones.

  • PDF

The Influence of Temperature on the Surface Electrokinetic Features of Particulate Matters in Aqueous Environment (수중입자의 표면 전기적 특성에 미치는 온도의 영향)

  • O, Sejin;Kim, Dong-Su
    • Journal of Korean Society on Water Environment
    • /
    • v.26 no.3
    • /
    • pp.525-531
    • /
    • 2010
  • To figure out the importance of temperature on electrochemical properties in water environment, calcium carbonate, one of important substances in water chemistry, was chosen to make suspensions. The result of electrokinetic potential of calcium carbonate suspensions revealed that it tended to increase as temperature increased. In addition, electrokinetic potential was negatively increased as suspensions became more basic. Its isoelectric point was ca. 7 regardless of temperature. The adsorption of hydrogen ions on calcium carbonate particles followed endothermic reaction. This result was verified by continuously measuring pH as adding HCl solution in calcium carbonate suspension. It explained that suspensions' potential was determined by DLVO theory which calculated total interaction energy between particles. Suspensions' total interaction energy was proportional to the value of electrokinetic potential. Furthermore, total interaction energy between particles increased as suspensions' temperature was increased.

Effect of the Urban Land Cover Types on the Surface Temperature: Case Study of Ilsan New City (도시지역의 토지피복유형이 지표면온도에 미치는 영향: 경기도 일산 신도시를 중심으로)

  • Kim, Hyun-Ok;Yeom, Jong-Min
    • Korean Journal of Remote Sensing
    • /
    • v.28 no.2
    • /
    • pp.203-214
    • /
    • 2012
  • The physical environment of urban areas covered mostly by concrete and asphalt is the main cause of the urban heat island effect, primarily becoming apparent through increased land surface temperature. This study examined the effect of different urban land cover types on the land surface temperature using MODIS, Landsat ETM+ and RapidEye satellite data. As a result, the remote sensing based land surface temperature showed a marked difference according to the land use pattern in the case study of Ilsan new city. The high-rise apartment residential districts with less building-to-land ratio and higher green area ratio revealed lower land surface temperature than the low-story single-family housing districts characterized by relatively high building-to-land ratio and low green area ratio. From the view of climate zone and land cover types, there is a strong linear correlation between the impervious land cover ratio and the land surface temperature; the land surface temperature increases as the impervious built-up areas expand. In contrast, vegetation;water and shadow areas affect the decrease of land surface temperature. There is also a negative (-) correlation between NDVI and land surface temperature but the seasonal variation of NDVI can be hardly corrected.

Long-term Variability of Sea Surface Temperature in the East China Sea: A Review (동중국해 표층수온의 장기 변동성: 종설)

  • Lee, Jae Hak;Kim, Cheol-Ho
    • Ocean and Polar Research
    • /
    • v.35 no.2
    • /
    • pp.171-179
    • /
    • 2013
  • The long-term variability of sea surface temperature in the East China Sea was reviewed based mainly on published literatures. Though the quantitative results are not the same, it is generally shown that sea surface temperature is increasing especially in recent years with the rate of increase about $0.03^{\circ}C$/year. Other meaningful results presented in the literatures is that the difference of water properties between layers upper and lower than the thermocline in summer shows an increasing trend both in temperature and salinity, suggesting that the stratification has been intensified. As a mechanism by which to evaluate the wintertime warming trend in the region, the weakening of wind strength, which is related to the variation of sea level pressure and atmospheric circulation in the western North Pacific and northern Asian continent, is suggested in the most of related studies.

Evaluation of Environmental Fatigue Strength in Adhesive Bonding of Different Materials (이종재료 접착제 접합부의 환경 피로강도 평가)

  • 임재규;이중삼;윤호철;유성철
    • Journal of Welding and Joining
    • /
    • v.20 no.5
    • /
    • pp.99-105
    • /
    • 2002
  • One of the important advantage of adhesive bonded joint can combine the different materials. The joint that bonded by structural adhesive bond must keep a large force and its strength is affected by some environmental factors such as temperature and submergence time in water. In order to advance the fatigue strength of adhesive bonded joint, mostly put a surface treatment on the surface. This study was researched the effect of air temperature, submergence time, submergence temperature and surface treatment on the fatigue strength. We found that submergence temperature has the most effect and low plasma treatment specimens have the most fatigue strength.

Effect of Temperature on the Surface Tensions in the Detergency System(I) -Change of Surface Tension Components of Washing Liquids- (온도가 세척계의 표면장력에 미치는 영향(제1보) -세액의 표면장력 성분변화를 중심으로-)

  • Chae, Chung-Hee;Kim, Sung-Reon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.17 no.4
    • /
    • pp.511-517
    • /
    • 1993
  • Changes of the surface and interface tension with temperature for washing liquids and alkanes were measured by FACE surface tensiometer. Using the extended Fowkes' equation, the dispersion and polar force components of the surface tension were estimated. The results were as follows : 1. The surface tensions of washing liquids and alkanes decreased almost linearly with the increase of temperature. 2. The interface tensions of 0.25% DBS/alkane increased slowly with the increase of temperature. In the case of nonionic surfactant solutions, however, the interface tensions with alkanes varied with the number of hydrophilic ethylene oxide(EO) groups. 3. Of the surface tension of water at $20^{\circ}C$, the dispersion force component was 25.3 dyn/cm and the polar force component was 47.8 dyn/cm. As the temperature increased, both the polar and dispersion force components decreased in a similar fashion. 4. The dispersion force component of surface tension of 0.25% DBS solution was 30.0 dyn/cm, and the polar force component was 2.2 dyn/cm at $20^{\circ}C$. The two components decreased with the increase of temperature. 5. As the temperature increased, the dispersion force component of surface tension decreased and the polar force component increased significantly for 0.25% NPPG-7.5EO solution. In the case of 025% NPPG-10EO, both the dispersion and polar force components decreased slowly, but the polar force component is expected to increase from $60^{\circ}C$. However, the polar force component of surface tension decreased with the increase of temperature for 025% NPPG-15EO solution, and at the temperature higher than $60^{\circ}C$ the surface tension is expected to be composed of only dispersion force component.

  • PDF

Oceanographic Characteristics of the Jspan Sea Proper Water II. The Japan Sea Proper Water and Chimney (동해고유수의 해양학적 특성 II. 동해고유수와 chimney)

  • Choi, Yong-Kyu;Cho, Kyu-Dae;Yang, Sung-Kee
    • Journal of Environmental Science International
    • /
    • v.4 no.2
    • /
    • pp.121-139
    • /
    • 1995
  • Based on the Results of Marine Meteorological and Oceanographical Observations (1966 -1987), the phenomenon of chimney is found as a candidate for the formation of the Japan Sea Proper Water (JSPW). The chimney phenomenon occurs twelve times Inuring 1966∼ 1987. The water types in the chimney denoting the deep convection are similar to those of the JSPW 0∼ 1℃ in potential temperature, 34.0∼34.1 ‰ in salinity and 68∼80 cl/t in potential thermosteric anomaly from the sea surface to the deep layer. The static stabilities in the chimney stations are unstable or neutral. This indicates that the winter time convection occurs. The JSPW sunken from the surface layer of chimney in winter spreads out under the Tsushima Warm Current area, following the isosteric surface of about 76 cl/t in Potential thermosteric anomaly. The formation of the deep water of the JSPW is mainly affected by the cooling of the sea surface than the evaporation of winds because the temperature and the salinity on the isoteric surface of about 76 cl/t in potential thermosteric anomaly ate cold and low The phenomenon of chimney occurred in here and there of the area in the north of 40" 30'N, west of 138" E. This suggests that the deep water of the JSPW is formed not in a limited area but probably in the overall region of the northern open ocean.

  • PDF

Failure Analysis of Commercial Water-Repellent Coatings for High Temperature Plant (플랜트 부품용 상용 발수코팅의 고온 환경 고장 특성 비교 분석)

  • Lee, Byung-Ho;Kim, Hye-young;Hyeon, Chang-young;Byeon, Jai-Won
    • Journal of Applied Reliability
    • /
    • v.17 no.1
    • /
    • pp.78-82
    • /
    • 2017
  • Purpose: The purpose of this study is to evaluate failure characteristic and mechanism of four commercial water-repellent coatings for elevated temperature machinery applications. Method: Thermal degradation was performed for up to 64 thermal cycles. 1 cycle consists of 15 minute holding at 523K under 300rpm revolution and 15 minute-natural cooling. Contact angle was measured and microstructure of the coating layer was observed by using a scanning electron microscope. Results: Four kinds of commercial repellent coating showed hydrophobic or super-hydrophobic property implying that all coatings are suitable for room temperature application. Contact angle of three kinds of commercial coatings decreased rapidly after thermal exposure, while only one specimen having hydrophobic surface showed extremely slow degradation. Conclusion: Observed decrease in contact angle of the coatings were attributed to formation of macro-sized pores and disappearance of micro-protrusion during thermal exposure. Optimum water-repellent coating needs to be selected under the consideration of initial contact angle as sell as service temperature.

Corrosion Behavior of Ytterbium Silicates in Water Vapor Atmosphere at High Temperature for Environmental Barrier Coating Applications (환경차폐코팅용 이터븀 실리케이트의 고온 수증기부식 거동)

  • Min-Ji Kim;Jae-Hyeong Choi;Seongwon Kim
    • Journal of the Korean institute of surface engineering
    • /
    • v.56 no.6
    • /
    • pp.443-450
    • /
    • 2023
  • SiC/SiCf CMC is vulnerable to water vapor corrosion at a high temperature of 1500℃. So, EBC (Environmental Barrier Coating) materials are required to protect Si-based CMCs. Ytterbium silicates are reported to have coefficient of thermal expansion (CTE) similar to that of the base material, such as SiC/SiCf CMC. When the EBC are materials exposed to high temperature environment, the interface between ytterbium silicates and SiC/SiCf CMC is not separated, and the coating purpose can be safely achieved. For the perspective of EBC applications, thermally grown oxide (TGO) layer with different CTE is formed by the reaction with water vapor in EBC, which leads to a decrease in life time. In this study, we prepare two types of ytterbium silicates to observe the corrosion behavior during the expose to high temperature and water vapor. In order to observe this behavior, the steam-jet furnace is prepared. In addition, phase formation of these ytterbium silicates is analyzed with microstructures by the before/after steam-jet evaluation at 1500℃ for 100 h.