• Title/Summary/Keyword: Surface Temperature

Search Result 14,492, Processing Time 0.044 seconds

Relationship between Sea Surface Temperature and Air Temperature Variation Depend on Time Scale at Coastal Stations in Korea (시간스케일에 따른 해양표면수온과 기온의 변동 및 상관연구)

  • 장이현;강용균;서영상
    • Journal of Environmental Science International
    • /
    • v.9 no.4
    • /
    • pp.303-309
    • /
    • 2000
  • The relationship between air temperature and sea surface temperature and studied using the daily air temperature and sea surface temperature data for 25 years (1970~1994) at 9 coastal stations in Korea. Seasonal variations of air temperature have larger amplitudes than those of sea surface temperature. The seasonal variations of air temperature leads those of sea surface temperature by 2 to 3 weeks. The anomalies of sea surface temperature and air temperature with time scales more than 1 month are more ghighly correlated than those of short term, with time scales less than 1 month. Accumulated monthly anomalies of sea surface temperature and air temperature for 6 months shwoed higher correlation than the anomailes of each month. The magnitudes of sea surface temperature and air temperature anomalies are related with the duration of anomalies. Their magnitudes are large when the durations of anomalies are long.

  • PDF

Daily Changes in Red-Pepper Leaf Surface Temperature with Air and Soil Surface Temperatures

  • Eom, Ki-Cheol;Lee, Byung-Kook;Kim, Young-Sook;Eom, Ho-Yong
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.5
    • /
    • pp.345-350
    • /
    • 2014
  • This study was conducted to investigate the changes in daily surface temperature of red pepper leaf compared to air and soil surface temperature. The maximum, minimum and average daily temperatures of red pepper leaf were 27.80, 11.40 and $19.01^{\circ}C$, respectively, which were lower by 0.10, 7.60 and $3.86^{\circ}C$ than air temperature, respectively, and lower by 15.00, 0.0 and $4.38^{\circ}C$ than soil surface temperature, respectively. Mean deviations of the difference between measured and estimated temperature by the E&E Model (Eom & Eom, 2013) for the air and surface temperature of red pepper leaf and soil were 0.64, 1.82 and $4.77^{\circ}C$, respectively. The relationships between measured and estimated scaled factor of the air and surface temperature of red pepper leaf and soil were very close to the 1:1 line. Difference between air and surface temperature of red pepper leaf showed a linear decreasing function with the surface temperature of red pepper leaf. Difference between soil surface temperature and air and surface temperature of red pepper leaf linearly increased with the soil surface temperature.

The Land Surface Temperature Analysis of Seoul city using Satellite Image (위성영상을 통한 서울시 지표온도 분석)

  • Jeong, Jong-Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.22 no.1
    • /
    • pp.19-26
    • /
    • 2013
  • The propose of this study is to analyze the optimum spatial resolution of the urban spatial thermal environment structure and to evaluate of the possibility detection using aerial photographs and thermal satellite images. The proper techniques of the optimum spatial resolution for the urban spatial thermal environment structure were analyzed. Thermal infrared satellite image of Seoul city were used for the change rate of surface temperature variation and suggested to the spatial extent and effects of urban surface characteristics and spatial data was interpreted as regions. To extract the surface temperature, Landsat thermal infrared satellite image compared with an automatic weather station data and in the field of the measured temperature and surface temperature by thermal environment affects, the spatial domain has been verified. The surface temperature of the satellite images to extract after adjusting surface temperature isotherms were constructed. The changes in surface temperature from 2008 to 2012 the average surface temperature observation images of changing areas were divided into space. The results of this study are as follows: Through analysis of satellite imagery, Seoul city surface temperature change due to extraction comfort indices were classified into four grades. The comfort index indicative of the temperature of Gangnam-gu, $23.7{\sim}27.2(^{\circ}C)$ range and Songpagu, a $22.7{\sim}30.6(^{\circ}C)$ respectively, the surface temperature of Yeouido $25.8{\sim}32.6(^{\circ}C)$ were in the range.

Measuring Temperature on Wood Surface at the Beginning of Drying Using IR Image Measuring System (적외선 화상처리 장치를 이용한 건조초기 목재 표면 온도 측정)

  • Lee, Kwan-Young;Kang, Ho-Yang;Lee, Min-Kyung
    • Journal of the Korea Furniture Society
    • /
    • v.17 no.3
    • /
    • pp.79-85
    • /
    • 2006
  • Temperature of board surface was monitored during drying using an IR image measurement system. Boards were water-saturated and dried at the levels of four temperatures and three air velocities. At higher DB the surface temperature increased more steeply and level off period was significantly short. At the DB temperatures of 70, 80, $90^{\circ}C$ the period where the surface temperature was equivalent to WB temperature was constant regardless of air velocity while at $60^{\circ}C$ it decreased as air velocity increased. It was confirmed that a surface transfer coefficient increased with DB temperature. Variation of temperature profile on a wood surface increased with DB temperature and air velocity.

  • PDF

A Study on Surface Temperature Patterns in the Tokyo Metropolitan Area Using ASTER Data

  • Fukui, Yuko
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1457-1459
    • /
    • 2003
  • This study reports the surface temperature pattern of the Tokyo Metropolitan area using the ASTER surface temperature product. The product is an image processed by applying temperature-emissivity separation to atmospheric corrected infrared thermal radiance of the land surface, then converted to surface temperature by using Planck's function. Daytime and nighttime observation in a cold season and a warm season were used in this study. As a result, 1) contrast between urban and suburban, 2) extraction of heating area in urban, 3) measurement of cooling effect of green space were achieved.

  • PDF

Analyzing Impact of the Effect of Greenbelts on the Land Surface Temperature in Seoul Metropolitan Area (수도권 그린벨트가 지표면 온도에 미치는 영향 분석)

  • Kim, Hee-Jae
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.17-31
    • /
    • 2020
  • This study aims to analyze the relations among greenbelt, urban land surface temperature empirically in order to assess the environmental effects of the greenbelt in the Seoul metropolitan area, objectively. For this purpose, this study conducts an empirical analysis of impacts of greenbelt on urban land surface temperature using a multiple-regression model. The main data employed in the analysis include real-time air pollution data, Landsat 8-OLI Landsat imagery data, KLIS data and Jip-gye-gu data. The major findings are summarized as follows. NDVI has a negative (-) correlation with the land surface temperature, and the urban temperature is high in areas with poor vegetation. The land surface temperature is low in residential or commercial areas, while the temperature is high in industrial areas. The temperature is low in green fields, open spaces, and river areas. it is found that the urban land surface temperature is low in the greenbelt zone. In the greenbelt zone, there is an effect that reduces the land surface temperature by 1% on average, as compared to that at the center of the Seoul metropolitan area. Especially, the center of the Seoul metropolitan area, in a range from 0.6% to 1.9% of the average temperature, the temperature gets lower up to approximately 3km from the greenbelt boundary.

Plasma Surface Treatment of the Polymeric Film with Low Temperature Process (저온프로세스를 이용한 고분자필름의 플라즈마 표면처리)

  • Cho, Wook;Yang, Sung-Chae
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.5
    • /
    • pp.486-491
    • /
    • 2008
  • The plasma processing is applied to many industrial fields as thin film deposition or surface treatment technique. In this study, we investigated large-area uniformed surface treatment of PET film at low temperature by using Scanning Plasma Method(SPM). Then, we measured difference and distribution of temperature on film's surface by setting up a thermometer. We studied the condition of plasma for surface treatment by examining intensity of irradiation of uniformed plasma. And we compared contact angles of treated PET film by using Ar and $O_2$ plasma based low temperature. In our result, surface temperature of 3-point of treating is low temperature about $22^{\circ}C$, in other hands, there is scarcely any variation of temperature on film's surface. And by using Ar plasma treatment, contact angle is lower than untreatment or $O_2$ plasma treatment. In case of PET film having thermal weak point, low temperature processing using SPM is undamaged method in film's surface and uniformly treated film's surface. As a result, Ar plasma surface treatment using SPM is suitable surface treatment method of PET film.

Change of Surface Temperature in Woodceramics Made from MDF(I) -Effect of Density and Burning Temperature- (MDF로 제조된 우드세라믹의 표면온도변화(I) -밀도 및 소성온도의 영향-)

  • 오승원
    • Journal of Korea Foresty Energy
    • /
    • v.21 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • The following conclusions were obtained with measuring the surface temperature change of woodceramics which were made of MDF to identify usability of using them as a sub-material for heating system when installing Ondol heating floor. For this purpose, woodceramics were burned at the temperature of $650^{\circ}C$ and $800^{\circ}C$ 1. Surface temperature of woodceramics increased with the increase of density of woodceramics, but no significant difference was detected at the surface temperature when burning temperature was changed. 2. Surface temperature change under given temperature increased as time passed and it showed more increase in temperature at the burning temperature of 80$0^{\circ}C$. 3. Surface temperature change with the change in floor temperature increased u hen floor temperature increased and heating mechanism was fast with increase of measuring temperature.

  • PDF

A Study of the Infrared Temperature Sensing System for Surface Temperature Measurement in Laser Welding(I) - Surface Temperature Profile According to Bead Shape - (레이저용접부 온도측정을 위한 적외선 온도측정장치의 개발에 관한 연구(I) -용융부 형상에 따른 표면온도분포-)

  • 이목영;김재웅
    • Journal of Welding and Joining
    • /
    • v.20 no.1
    • /
    • pp.62-68
    • /
    • 2002
  • This study investigated the feasibility of penetration depth measurement using infrared temperature sensing on the weld surface. The detection point was optimized by FEM analysis in the laser keyhole welding. The profile of the weld surface temperature was measured using infrared detector array. Surface temperature behind the weld pool is proportional or exponentially proportional to penetration depth and bead width. From the results, the monitoring device of surface temperature using infrared detector array was applicable fur real time penetration depth control.

A Study on the Thermal Performance of Embossing Surface Sandwich Panel

  • Son, Cheol-Soo
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.9 no.2
    • /
    • pp.69-76
    • /
    • 2001
  • The purpose of this research is to investigate the thermal performance of embossing surface sandwich panel and flat surface sandwich panel. To do this research, thermal performances in summer season at the six points of embossing surface sandwich panel and flat surface sandwich panel are investigated focusing on the temperature. Three kinds of embossing surface sandwich panel and one kind of flat surface sandwich panel are used for this research. At the same size of sandwich panel, the average temperature differences of flat surface sandwich panel between average temperature at the 0.5 mm below copper plate and average outside air temperature and surface temperature are higher than those of embossing surface sandwich panel. The average heat transfer rate of flat surface sandwich panel in higher than that of embossing surface sandwich panel. More study will be needed about the size of diameter and height of embossing, and materials of embossing surface sandwich panel.

  • PDF