• Title/Summary/Keyword: Supervisory control and data acquisition

Search Result 117, Processing Time 0.023 seconds

Development of intelligent distribution automation system with the function of substation SCADA, power quality monitoring and diagnosis condition monitoring (SCADA 기능과 전기품질 온라인 감시 및 배전설비 열화감시 기능을 갖는 배전지능화 시스템 개발)

  • Ha, B.N.;Lee, S.W.;Shin, C.H.;Seo, I.Y.;Jang, Mun-Jong;Park, M.H.;Yun, G.G.;Song, I.K.;Lee, B.S.;Lee, J.C.;NamKoong, W.
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1776-1786
    • /
    • 2010
  • Intelligent distribution automation system have total monitoring and control capability. The system covers substation, distribution network, distributed generations and customers at HV system. Various intelligent distribution facilities installed at distribution systems have voltage sensor, current sensor, aging monitoring sensor. Intelligent Feeder Remote Terminal Unit (IFRTU) tied to intelligent distribution facilities process information from facilities and it checks information of fault, power quality and aging of distribution facilities. The information is transmitted to master station through communication line. The master station have remote monitoring system covers substation, distribution network, distributed generations and customers. It also have various application programs that maintain optimal network operation by using information from on-site devices.

A Study of Integrated SCADA System for Wind Farm to Support Interoperability (이기종간의 상호운용을 지원하는 풍력발전 통합 SCADA 시스템에 관한 연구)

  • Kim, Young-Gon;Moon, Chae-Joo;Joo, Yeong-Tae;Park, Tae-Sik;Chang, Young-Hak
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.6
    • /
    • pp.70-76
    • /
    • 2013
  • Recently industrial control systems have been required to ensure intelligent, high tech automation, interconnection and interoperability demands. Therefore, there is a need to redefine the structure concepts of SCADA system for wind power. Also, at this time, the integrated management system is required for the distributed development of wind farms where are needed often interoperability features and exchange information between different wind farms, wind turbines or SCADA systems. In this paper, an integrated structural concepts for SCADA system are defined. Based on this definition of an integrated SCADA system, the basic designs are analyzed on physical layer, system layer and application layer which are corresponded to wind turbine controller, the SCADA server and the SCADA client, and implement HMI. Between the implementation SCADA server and the client, their normal functions were verified at the small scale wind energy test facilities.

Characteristics of Wind Environment in Dongbok·Bukchon Wind Farm on Jeju (제주 동복·북촌 풍력발전단지의 바람환경 특성분석)

  • Jeong, Hyeong-Se;Kim, Yeon-Hee;Choi, Hee-Wook
    • New & Renewable Energy
    • /
    • v.18 no.1
    • /
    • pp.1-16
    • /
    • 2022
  • Climatic characteristics were described using the LiDAR (Light Detection and Ranging) and the met-mast on Dongbok·Bukchon region. The influences of meteorological conditions on the power performance of wind turbines were presented using the data of Supervisory Control And Data Acquisition (SCADA) and met-mast of the Dongbok·Bukchon Wind Farm (DBWF) located in Jeju Island. The stability was categorized into three parameters (Richardson number, Turbulence intensity, and Wind shear exponent). DBWF was dominant in unstable atmospheric conditions. At wind speeds of 14 m/s or more, the proportion of slightly unstable conditions accounted for more than 50%. A clear difference in the power output of the wind turbine was exhibited in the category of atmospheric stability and turbulence intensity (TI). Particularly, a more sensitive difference in power performance was showed in the rated wind speeds of the wind turbine and wind regime with high TI. When the flow had a high turbulence at low wind speeds and a low turbulence at rated wind speeds, a higher wind energy potential was produced than that in other conditions. Finally, the high-efficiency of the wind farm was confirmed in the slightly unstable atmospheric stability. However, when the unstable state become stronger, the wind farm efficiency was lower than that in the stable state.

A Centralized Monitoring System for Factory Electrical Installation Using Active Database (능동 데이터베이스를 이용한 중앙전력감시시스템)

  • Choi, Sang-Yule;Moon, Hyun-Ho;Lee, Jong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.6
    • /
    • pp.115-122
    • /
    • 2010
  • The main purpose of centralized monitoring system is to manage factory electrical installation efficiently by on-line data acquisition and supervisory control. The existing centralized system is only able to be managed by operator whenever electrical installation's faults are detected. Therefore, it may be possible for propagating the installation's faults when operator make the unexpected mistakes. To overcome the unexpected mistakes, in this paper, the author presents a centralized monitoring system for factory electrical installation using active database. by using active database production rule, stated system can minimize unexpected mistake and can operate centralized monitoring system efficiently. Test results on the five factory electrical installations show that performance is efficient and robust.

A Study on the Development of the SCADA System using the Internet (인터넷을 이용한 SCADA 시스템 구축에 관한 연구)

  • Park, I.K.;Yoon, K.K.;Kim, Y.S.;Lee, S.G.;Ahn, B.W.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2373-2376
    • /
    • 1998
  • This paper describes the development of the SCADA(Supervisory Control and Data Acquisition) system which can be controlled via the Internet. In this paper, the SCADA system is composed of a number of microprocessor-based RTU(Remote Terminal Unit)s, a MMI(Man Machine Interface) host, a SCADA server, and SCADA clients. There are two protocols used in the system. Each RTU and the MMI host are connected by a RS-485 line and CSMA/CD(Carrier Sense Multiple Access / Collision Detection) protocol is used to communicate with each other. TCP/IP(Transmission Control Protocol/Internet Protocol) is used among the MMI host, the SCADA server, and SCADA clients. The equipments installed in the field are controlled by a number of RTUs. The function of the MMI host is to acquire real-time data from RTUs and control them. The SCADA server supports data transfer between the networked MMI host and the SCADA client on the web-server through TCP/lP. Data transfer is possible regardless of the type of network only if there are TCP/lP Winsock-compatible stack driver. The SCADA client is implemented as the shape of web-page by means of JAVA language. Therefore, it runs on a web-browser such as Netscape and Explorer, and allows a number of users to access this SCADA system.

  • PDF

A Development of Cipher Device based on Embedded Linux for Serial Communication in SCADA (임베디드 리눅스 기반의 SCADA 직렬통신 구간 암호화 장치 개발)

  • Lee, Jong-Joo;Kim, Seog-Joo;Kang, Dong-Joo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.4
    • /
    • pp.25-32
    • /
    • 2010
  • The Supervisory Control and Data Acquisition Systems (SCADA) system provides monitoring, data gathering, analysis, and control of the equipment used to manage most infrastructure. The SCADA Network is implemented in a various manner for larger utilities, and multiple types of protocol and communication interfaces are used to network the control center to remote sites. The existing SCADA equipment and protocols were designed and implemented with availability and efficiency, and as a result security was not a consideration. So, performance, reliability, flexibility and safety of SCADA systems are robust, while the security of these systems is often weak. This makes some SCADA networks potentially vulnerable to disruption of service, process redirection, or manipulation of operational data that could result in public safety concerns and/or serious disruptions to the infrastructure. To reduce the risks, therefore, there is a need to have a security device such as cipher devices or cryptographic modules for security solutions. In this paper we develop an embedded cipher device for the SCADA equipment. This paper presents a cipher device designed to improve the security of its networks, especially in the serial communication.

Proposal and Implementation on Non-Repudiation of Origin for DNP3 (DNP3에 적합한 발신 부인 방지 기법 제안과 그 구현)

  • Yu, Ki-Soon;Song, Kyoung-Young;Jang, Min-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.5
    • /
    • pp.815-825
    • /
    • 2015
  • DNP3(Distributed Network Protocol) is one of the most representative protocols which is used in SCADA(Supervisory Control and Data Acquisition) system. IEC 62351 is listing the integrity, confidentiality, availability and non-repudiation or accountability as the security requirement. However, IEEE Std. 1815 that is DNP3 standards does not define a mechanism for non-repudiation or accountability. In this paper, we propose a non-repudiation of origin technique about the sender of critical ASDU and implement the proposed scheme using software such as OpenSSL and SCADA source code library.

Non-invasive acceleration-based methodology for damage detection and assessment of water distribution system

  • Shinozuka, Masanobu;Chou, Pai H.;Kim, Sehwan;Kim, Hong Rok;Karmakar, Debasis;Fei, Lu
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.545-559
    • /
    • 2010
  • This paper presents the results of a pilot study and verification of a concept of a novel methodology for damage detection and assessment of water distribution system. The unique feature of the proposed noninvasive methodology is the use of accelerometers installed on the pipe surface, instead of pressure sensors that are traditionally installed invasively. Experimental observations show that a sharp change in pressure is always accompanied by a sharp change of pipe surface acceleration at the corresponding locations along the pipe length. Therefore, water pressure-monitoring can be transformed into acceleration-monitoring of the pipe surface. The latter is a significantly more economical alternative due to the use of less expensive sensors such as MEMS (Micro-Electro-Mechanical Systems) or other acceleration sensors. In this scenario, monitoring is made for Maximum Pipe Acceleration Gradient (MPAG) rather than Maximum Water Head Gradient (MWHG). This paper presents the results of a small-scale laboratory experiment that serves as the proof of concept of the proposed technology. The ultimate goal of this study is to improve upon the existing SCADA (Supervisory Control And Data Acquisition) by integrating the proposed non-invasive monitoring techniques to ultimately develop the next generation SCADA system for water distribution systems.

A Study on the Security Management for Critical Key Infrastructure(SCADA) (중요핵심기반시설(SCADA)에 대한 보안 관리 연구)

  • Kim InJung;Chung YoonJung;Koh JaeYoung;Won Dongho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.8C
    • /
    • pp.838-848
    • /
    • 2005
  • Most of the national critical key infrastructure, such as power, piped gas and water supply facilities, or the high-speed railroad, is run on the SCADA system. Recently, concerns have been raised about the possibility of these facilities being attacked by cyber terrorists, hacking, or viruses. Thus, it is time to adopt the relevant security management techniques. This paper attempts to propose such security management techniques, including information protection measures and troubleshooting, based on a risk analysis process concerning assets, threats/vulnerability, and hazards, and to examine the security management status of critical key infrastructure in the U.S. and Japan.

DLMS SCADA System based on TETRA (TETRA 기반 DLMS 원방감시 시스템)

  • Song, Byung-Kwen;Lee, Suk-Hee
    • Journal of IKEEE
    • /
    • v.13 no.3
    • /
    • pp.95-102
    • /
    • 2009
  • TETRA(TErrestrial Trunked RAdio) is wireless communication system generally adopted to public network and backbone network, as the technology of Trunked Radio System specified by ETSI(European Telecommunications Standards Institute) and currently adopted to the Electric Power IT Backbone Network in Korea. DLMS(Device Language Message Specification) is used in order to meter an electric measuring instrument value. In this paper, DLMS Server and Client simulator are used based on Window operating system. The multi-functional gateway, which transforms the communications based on RS-232C between DLMS Server Simulator and Client Simulator to the one based on TETRA PEI(Peripheral Equipment Interface), is developed such that DLMS SCADA(Supervisory Control And Data Acquisition) system is constructed based on TETRA.

  • PDF