Piping Failure Analysis In Domestic Nuclear Safety Piping System (국내 안전등급 배관에 대한 손상사례 분석)

  • Choi, Sun-Yeong;Choi, Young-Hwan
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.617-621
    • /
    • 2003
  • The purpose of this paper is to analyze piping failure trend of safety pipings In domestic nuclear power plants. First, database for the piping failure was constructed with 105 data fields. The database includes plant population data, event data, and service history data. 7 kinds of piping failures in domestic NPPs were investigated. Among the 7 cases, detailed root causes were investigated for 3 cases. The first one is pipe wall thinning in main feedwater pipings of Westinghouse 3 loop type plants. The root cause of the wall thinning was flow accelerated corrosion near welding area. The next one is leak event in chemical and volume control system(CVCS) due to vibration. Some cracks occurred in socket welding area. The events showed that the integrity or socket weld is very vulnerable to vibration. The last one is also a leak event in primary sampling line in Korean standard reactor due to thermal fatigue. Although the structural integrity was not maintained by the events, there was no effect on nuclear safety in the above 3 piping failure eases.

  • PDF

A Study on the Formation of Fouling in a Heat Exchanging System for HAN-River Water as Cooling Water (냉각수로 하천수를 이용하는 열교환 시스템내 Fouling 형성에 관한 연구)

  • Sung, Sun-Kyung;Suh, Sang-Ho;Roh, Hyung-Woon;Cho, Young-Il
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.1473-1478
    • /
    • 2003
  • Scale is formed when hard water is heated or cooled in heat transfer equipments such as heat exchangers, condensers, evaporators, cooling towers, boilers, and pipe walls. When scale deposits in a heat exchanger surface, it is traditionally called fouling. The objective of the present study is to investigate the formation of fouling in a heat exchanging system. A lab-scale heat exchanging system is built-up to observe and measure the formation of fouling experimentally. Water analyses are conducted to obtain the properties of HAN river water. In the present study a microscopic observation is conducted to visualize the process of scale formation. Hardness of HAN-river water is higher than that of tap water in Seoul.

  • PDF

Determinating Sensor Location for Guided-Wave-Based Long Range Pipeline Inspection (유도파 기반 장거리 파이프라인 검사를 위한 모니터링 센서의 위치결정)

  • Na Won-Bae;Ryu Yeon-Sun;Kim Jeong-Tae
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2006.04a
    • /
    • pp.232-239
    • /
    • 2006
  • Guided wave techniques have been used for pipeline inspection because of the long range inspection capability of guided waves. One of main concerns of these technique is how ones decide the axial interval of sensors when they are utilized for pipeline inspection. This question is related to the characteristic of cylindrical guided wave propagation, especially wave attenuation. Thus, attenuation of fundamental longitudinal guided wave propagating liquid-filled steel pipes is numerically investigated in the paper. Several liquids such as water, diesel oil, castor oil etc. are considered for the filing materials in the pipes. Sink is considered for numerical models for abandoning standing wave modes; hence, the attenuation dispersion curves become much simpler. Those attenuation calculations can be utilized for guided-wave-based nondestructive testing of pipelines when one inspects pipelines, using monitoring sensors, which are installed outside pipes.

  • PDF

Case of construction method to the railway tunnel under the road (도로하부를 통과하는 철도터널의 특수공법 적용사례)

  • Kim, Sun-Hong;Jo, Yong-Seok;Kim, Dong-Ki;Park, Byung-Eun
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.337-344
    • /
    • 2007
  • This paper is about the examination and selection of the special method applied to the railway tunnel which will lie under the road. Moreover, the road was constructed on the weak ground. Eventually, we select DSM, considering geological condition, stability during construction of the railway tunnel, and economic efficiency. The 3D-analysis, performed with PENTAGON-3D and MIDAS CIVIL-3D, shows that allowable standards are all satisfied. In the design of the railroad tunnel under the road at low depth, this paper will give useful data for the selection of the tunneling method.

  • PDF

A Flow Quantity Distribution Characteristics of the Hot Water Header for Individual Room Control System (실별제어 온수분배기의 유량분배 특성)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2008
  • Flow quantity to supply to a coil in floor heating system is important to achieve comfortable indoor air condition in the winter season. The hot water header is used to distribute the water into the coil. Experimental study has been performed using the water header that have 5 branches consisted of flow control valves and automatic shut-off valves. Each branch line connected it with X-L pipe. Experimental tests accomplished it to investigate the flow distribution characteristics of the hot water header. Experimental results show that the selection of the pump head and differential pressure are very important to save running energy of the system, and high differential pressure needs more friction loss in the case of suitable differential pressure for balancing of the header.

Investigation of Research & Development Trends for Sunlight System (태양광 채광 시스템의 기술개발동향에 관한 조사분석연구)

  • Kim, Sun-Ho;Yoon, Kwang-Sik;Kim, Byung-Cheol
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2007.11a
    • /
    • pp.260-263
    • /
    • 2007
  • The importance of natural light in building is known by all of us who experienced dark rooms. The sunlight system is very important from energy saving and human welfare point of view. The system consists of light-collecting module, light -transporting module and light-emitting module. The light-collection is used light reflection mirror, a prism for lighting bent, and lens for light condensing. The transportation of collected sunlight is used polished duct, tube, pipe and specially used fiber optic cable. This paper investigate research and development trends of sunlight system for advanced product.

  • PDF

Development of Vehicle Door Impact Beam by Hot Stamping (핫스탬핑에 의한 자동차 도어 임팩트빔의 개발)

  • Yum, Young-Jin;Kim, Jong-Gook;Lee, Hyun-Woo;Hwang, Jung-Bok;Kim, Sun-Ung;Kim, Won-Hyuck;Yoo, Seung-Jo
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.7-12
    • /
    • 2008
  • A hot stamping technology of vehicle door impact beam made of thin sheet steel has been developed, with the aim of ensuring occupant safety in a side collision. This technology has been implemented to increase the strength of vehicle body parts and to reduce not only the weight of door impact beam but also the number of work processes. Mechanical tests were performed to obtain material properties of hot-stamped specimen and those were used as input data in stamping and structural simulation for optimal design of door impact beam. Strength of hot-stamped door impact beam increased to the value 102% higher than that of conventional pipe-shaped door impact beam and structural simulation showed that hot-stamped door impact beam achieved 28% weight reduction.

  • PDF

Development of Failure Pressure Evaluation Model for Local Wall-Thinned Elbows Based on Finite Element Analysis (유한요소해석에 기초한 감육곡관 손상압력 평가 모델 개발)

  • Kim, Jin-Weon;Park, Jong-Sun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.32 no.12
    • /
    • pp.1063-1071
    • /
    • 2008
  • This paper provides a failure pressure evaluation model for local wall-thinned elbows. In this study, parametric finite element analyses are performed on the elbows containing local wall-thinning defect at their intrados and extrados, and the failure pressures are obtained from the analysis results by applying a local failure criterion that was validated by real-scale pipe tests. An evaluation model including the effects of thinning depth, length, circumferential angle, thinning location, and elbow geometries on the failure pressure is derived based on the evaluated failure pressures. The proposed model agrees well with the results of finite element analyses and reasonably estimates the dependence of failure pressure on the wall-thinning dimensions and elbow geometries. Also, the comparison with experimental data demonstrates that the proposed evaluation model can accurately predict the failure pressure of local wall-thinned elbows.

A Study on Characteristic of Residual Stresses in a wind Tower Using the Tandem Circumferential Welding Process (Tandem 용접을 이용한 풍력타워 원주용접부 잔류응력 특성에 관한 연구)

  • Kim, Ji Sun;Kim, In Ju
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.21 no.6
    • /
    • pp.938-945
    • /
    • 2012
  • This research proposes FEM analysis for Tandem welding process used in wind tower and predicts optimal welding process to improve the stability of welded structures. Three dimensional elasto-plastic analyses are employed to evaluate thermo-mechanical behavior of residual stress and deformation during Tandem welding for different distance between two touches. To confirm the thermal distribution, Goldak's ellipse heat source model and the real size wind tower pipe model are utilized. Four different analyses are being performed, where in each case the distance between two electrode torches is being changed and residual stress and welding deformation are predicted. Depending on base material state, each case is divided into: Liquid (100mm), Austenite+Liquid (200mm), Austenite+Cementite (400mm), Pearlite+Cementite (800mm).

The study on the measurement for the pressure drop and friction factor of corrugated metal pipes (주름관에서의 압력강하와 마찰손실 계측에 관한 연구)

  • Yun, Young-Sun;Kang, Jun-One;Yoo, Jai-Suk;Kim, Hyung-Jung
    • Journal of the Korean Society of Visualization
    • /
    • v.4 no.2
    • /
    • pp.76-80
    • /
    • 2006
  • The data for friction factor of the pipe correlated by Reynolds number and relative roughness have been reported well as a Moody chart. However, the results for corrugated shapes have been not investigated sufficiently. In this research, therefore, the pressure drop and friction factor are obtained. Flexible metal tubes with corrugations for the measurement are made of stainless steel plates. The kinds of tubes for the measurement are 5 annular types and helical types. The pressure drop & the velocity of the flow are obtained by micromanometer & digital pressure sensor, supplying dry air at several steps. Then the pressure drop is calculated for each tube, using the obtained data. The result shows that the pressure drop is strongly influenced by the viscous dissipation of kinetic energy due to the circulation of flows, rather than a viscous friction loss. The pressure drop increased consistently as the Reynolds number increases.

  • PDF