• Title/Summary/Keyword: Summer Power

Search Result 400, Processing Time 0.022 seconds

A study on efficient operation of DC track circuit (DC 궤도회로의 효율적인 운용방법에 대한 연구)

  • Jang, Dongwan;Jeon, Taehyun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.2
    • /
    • pp.70-75
    • /
    • 2014
  • A track circuit is a critical piece of equipment that allows the existence of the trains on the track to be detected. Train detection is very important for the signal safety equipment. It allows for the confirmation of a train's location, the locking of switch points, the coordination of safe distance between trains, and the advance notice of a train's arrival. Track circuits can be powered by AC or DC. The DC track circuits are usually used on non-electrified tracks. On these tracks, many signal errors can be caused by lightning or problems with the power source. These problems can also cause damages to the rectifiers which must be repaired or replaced, promptly. This issue is especially problematic in the summer because of the higher frequency of thunderstorms. Issues with track circuits also cause problems for other equipment, such as railroad crossings and switch points. This further disrupts the safe operation of trains. This study aims to enhance maintenance efficiency and improve safety by utilizing parallel operation and multiplexing of a DC track circuit as well as installing an external surge protector. The experimental results on the operation of the proposed method is also presented.

A Study on the Characteristics of Local Corrosion for Gas Absorption Refrigeration and Hot Water Systems in LiBr-$H_2O$ Working Fluids (LiBr작동유체 중에서 가스흡수식 냉온수기의 국부부식 특성에 관한 연구)

  • Uh- Joh Lim;Ki-Cheol Jeong;Byoung-Du Yun
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.27 no.6
    • /
    • pp.714-720
    • /
    • 2003
  • Due to the electric power shortage in summer season and regulation of freon refrigerant, the application of gas absorption refrigeration and hot water systems are considerably increasing trend. But, this system consists of condenser, heat exchanger, supply pipe and radiator etc. which are easily corroded by acidity and dissolved oxygen and gases. In result, this system occurs scale attachment and corrosion damage like pitting and crevice corrosion. In this study, electrochemical polarization test of heat exchanger tubing material (copper, aluminium brass, 30% cupronickel(30% Cu-Ni)) was carried out in 60% lithium bromide solution at $95^{\circ}C$. As a result of polarization test, corrosion behavior by impressed potential and local corrosion. such as galvanic corrosion, pitting corrosion behavior, of tubing materials was investigated. The main results obtained are as follows: (1) The effect of pitting and crevice corrosion control of 30% cupronickel in 60% LiBr solution at $95^{\circ}C$ is very excellent. (2) Dissimilar metal corrosion of 30% cupronickel coupling to aluminium bronze is the most sensitive. (3) Current density behavior of tube materials by impressed potential is high in order of copper > aluminium brass > 30% cupronickel.

Designing Forward Markets for Electricity using Weather Derivatives (날씨파생상품을 이용한 전기선물시장 설계)

  • Yoo, Shiyong
    • Environmental and Resource Economics Review
    • /
    • v.15 no.2
    • /
    • pp.319-353
    • /
    • 2006
  • This paper shows how weather derivatives can be used to hedge against the price risk and volume risk of purchasing relatively large amounts of electricity. Our specific approach to designing new contracts for electricity is to focus on the return over a summer season rather than on the daily levels of demand and price. It is shown that correct market signals can be preserved in a contract and the associated financial risk can be offset by weather options. The advantage of combining a forward contract with a weather derivative is that the high prices on hot days or when the temperature is high reflect the underlying high cost of producing power when the load is high and that the combined contract with a weather derivative substantially reduces the volatility of the return.

  • PDF

Thermal Effluent Diffusion and Flow Characteristics using the TGPS Buoy (TGPS 부이를 이용한 온배수 확산과 흐름 특성)

  • 박일흠;이연규;최정민
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2000.10a
    • /
    • pp.614-617
    • /
    • 2000
  • To get the maximum diffusion boundary of thermal effluent of Youngkwang Nuclear Power Plant, paths of TGPS Buoy and temperatures of surface water are obtained to 4 times at spring tide during 1 year. According to the paths of TGPS Buoy, the flumes of thermal effluent are moved about 12km from outlet to SW or WSW direction. After 3∼4 times of tidal period the waters are reached to Chilsan Island because the ebb flow is more predominant than the flood flow in this area. At the spring and fall season, a sudden drop of surface water temperature is detected around 5km radius from the outlet. At the summer season, it is measured about 10km. On the other hand the flumes are continuously cooled down by the atmosphere condition at winter season.

  • PDF

Emissions of Volatile Organic Compounds from a Swine Shed

  • Osaka, Nao;Miyazaki, Akane;Tanaka, Nobuyuki
    • Asian Journal of Atmospheric Environment
    • /
    • v.12 no.2
    • /
    • pp.178-191
    • /
    • 2018
  • The concentrations and chemical compositions of volatile organic compounds (VOCs), including volatile fatty acids, phenols, indoles, aldehydes, and ketones, which are the main organic compounds generated by swine, were investigated in July and October 2016 and January 2017. In addition, the emission rates and annual emissions of these components from the swine shed were estimated. The concentrations of VOCs in the swine shed averaged $511.3{\mu}g\;m^{-3}$ in summer, $315.5{\mu}g\;m^{-3}$ in fall and $218.6{\mu}g\;m^{-3}$ in winter. Acetone, acetic acid, propionic acid, and butyric acid were the predominant components of the VOCs, accounting for 80-88% of the total VOCs. The hourly variations of VOC concentrations in the swine shed in fall and winter suggest that the VOC concentrations were related to the ventilation rate of the swine shed, the activity of the swine, and the temperature in the swine shed. Accordingly, the emission rates of VOCs from the swine shed were $1-2{\times}10^3{\mu}g(h\;kg-swine)^{-1}$.

A Study on the Damage Reduction Strategy Against a Harmful Aquatic Organism, Jellyfish's Bloom (유해 해양생물 해파리 피해 저감 방안 연구)

  • Park, Seongwook;Lee, Kyounghoon;Yoon, Won-Duk;Lee, Dong-Gil;Kim, Seonghun;Yang, Yong-Su;Lee, Geon-Ho
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.1
    • /
    • pp.49-62
    • /
    • 2015
  • As methods reducing damages by jellyfish which enter the coastal areas of Korea, attaching cutting devices to towing nets of otter trawls or pair trawls and/or using a canvas type of cutting nets of small fishing boats have been widely utilized. In order to reduce shut-down damages of power plants in coastal areas due to the mass influx of marine organisms including jellyfish, a possible improvement of the traveling water screen system and various jellyfish influx blocking devices were suggested in this study. The results could be utilized as an important index for reducing damages by jellyfish bloom which cause on a massive scale in summer in Korea.

A Detailed Survey on the Solar Availability for the Construction of Photovoltaic Power Generation Sites (태양광발전단지 건설을 위한 태양광자원 정밀조사)

  • Jo, Dok-Ki;Kang, Young-Heack;Lee, Euy-Joon;Auh, Chung-Moo
    • Journal of the Korean Solar Energy Society
    • /
    • v.24 no.2
    • /
    • pp.83-88
    • /
    • 2004
  • Since the solar radiation is the main input for sizing any solar photovoltaic system, it will be necessary to understand and evaluate the insolation data. The Korea Institute of Energy Research(KIER) has begun collecting horizontal global insolation data since May, 1982 at 16 different locations. Because of a poor reliability of existing data, KIER's new data will be extensively used by solar photovoltaic system users as well as by research institutes From the results, we can conclude that 1) The yearly averaged horizontal global insolation of Korea was turned out $3.57kWh/m^2.day$ in the periods of $1982\sim2001$. 2) Horizontal global insolation of spring and summer was respectively 24 % and 21 % higher than the yearly average value, and that of fall and winter was respectively 12 % and 34 % lower than the yearly average value.

Analysis of Performance of Building Integrated PV System of Cold Facade type (Cold facade형 BIPV시스템의 발전성능 분석)

  • Kim, Hyun-II;Kang, Gi-Hwan;Park, Kyung-Eun;Yu, Gwon-Jong;Shu, Seung-Jik
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.275-280
    • /
    • 2008
  • Photovoltaic(PV) permit the on-site production of electricity without concern for fuel supply or environmental adverse effects. The electrical power is produced without noise and little depletion of resources. So BIPV(Building-Integrated Photovoltaic) system have been increased around the world. Hereby the relative installation costs of the system will be relatively low compared to traditional installations of PV in high-rise buildings. This paper examined possibility of BIPV system of cold facade type and analyzed of performance of BIPV system of cold facade type. The system is influenced by conditions such as irradiation, module temperature, shade and architectural component etc. If this BIPV system of 1.1kW is possible the natural ventilation in the summer case, the temperature of PV module decrease and then the efficiency of PV system increase generally. By the results, the annual averaged PR of BIPV system of cold facade type is about 73.1%.

  • PDF

Economic Feasibility Study for Peak Load Control (최대부하제어(最大負荷制御)의 경제적(經濟的) 타당성(妥當性) 검토(檢討))

  • Yu, Sung-Chul;Yoon, Kap-Koo;Cho, Soon-Bong
    • Proceedings of the KIEE Conference
    • /
    • 1993.11a
    • /
    • pp.19-22
    • /
    • 1993
  • Demand side management (DSM) is the planning and implementation of those utility designed to influence customer use of electricity in ways that will produce desired changes in the utility's load shape. It is conspicuous that the peak load control of DSM is efficiently adopted. In this paper, the package type air conditioner(A/C) mounted radio controlled switch. During the summer of 1990 KEPCO conducted tests in Seoul areas to determine the economic feasibility of interrupting A/C units for short periods of time during peak load periods. These tests were performed between July 30 and September 20 and were limited to the hours of between 1 and 6 p.m. These tests indicated that each A/C contributes approximately 4.5kW to the system peak and can be switched off 10 minutes out of each 1/2 hour without causing the customer any discomfort. Switching each A/C off for 10 minutes out of each 1/2 hour results in a peak load demand reduction of one kW per unit.

  • PDF

Screening of Antioxidant Activity from Exocarp of Watermelon (Citrullus vulgaris L.) (수박(Citrullus vulgaris L.) 외피의 항산화 활성 탐색)

  • Duan, Yishan;Kim, Min-A;Kim, Han-Soo;Jang, Seong-Ho;Kang, Dong-Soo
    • Journal of Environmental Science International
    • /
    • v.23 no.7
    • /
    • pp.1233-1239
    • /
    • 2014
  • Watermelon (Citrullus vulgaris L.) is a summer fruit typical to help fatigue systemic absorption is getting better. The goal of this study is to screen antioxidant activity to ensure the possibility as a functional material for exocarp of watermelon. Watermelon was extracted with 70% methanol, 70% ethanol, chloroform:methanol (CM, 2:1, v/v). Total phenol contents were 12.01 mg/g, 8.89 mg/g, 3.53 mg/g in the 70% methanol, 70% ethanol, CM, in that order, respectively. Total flavonoid content, DPPH radical scavenging activity, ABTS radical scavenging activity, ferric reducing antioxidant power (FRAP), ${\beta}$-carotene bleaching assay were 70% methanol extract remarkably higher than the other extracts. And these results showed the same trend of total phenol content. From the above results shows that watermelon was effective on the antioxidative activity.