• 제목/요약/키워드: Suction fluid

검색결과 320건 처리시간 0.023초

The Effect of Suction and Injection on Unsteady Flow of a Dusty Conducting Fluid in Rectangular Channel

  • Attia Hazem Ali
    • Journal of Mechanical Science and Technology
    • /
    • 제19권5호
    • /
    • pp.1148-1157
    • /
    • 2005
  • In the present study, the unsteady Hartmann flow of a dusty viscous incompressible electrically conducting fluid under the influence of an exponentially decreasing pressure gradient is studied without neglecting the ion slip. The parallel plates are assumed to be porous and subjected to a uniform suction from above and injection from below. The fluid is acted upon by an external uniform magnetic field which is applied perpendicular to the plates. An analytical solution for the governing equations of motion is obtained to yield the velocity distributions for both the fluid and dust particles.

극저비속도 원심펌프의 펌프성능 및 흡입성능 향상 (Improvement of Pump Performance and Suction Performance of a Very Low Specific Speed Centrifugal Pump)

  • 최영도;쿠로카와준이치
    • 한국유체기계학회 논문집
    • /
    • 제9권3호
    • /
    • pp.29-35
    • /
    • 2006
  • There are high expectations of improving the performance of a centrifugal pump in the range of very low specific speed which has been developed recently for the use instead of a conventional positive displacement pump. However, even though elaborated studies has been done for the pump intensively, the pump performance has not increased so much. Also, it is difficult to find detailed information from published literatures for suction performance of the very low specific speed centrifugal pump. Therefore, this study is aimed to improve the pump performance more and to make clear suction performance of the very low specific speed centrifugal pump. Recircular flow stopper is installed on the pump casing wall at the region of impeller outlet to improve the pump performance and J-Groove is also installed at the inlet of the pump casing for the purpose of suppressing occurrence of cavitation as well as improving pump performance. The result suggests that the simultaneous improvement of pump performance and suction performance of the very low specific speed centrifugal pump is possible by adopting optimum configuration of the recirculation flow stopper and J-Groove.

Vortex Cavitation from Baffle Plate and Pump Vibration in a Double-Suction Volute Pump

  • Sato, Toshiyuki;Nagahara, Takahide;Tanaka, Kazuhiro;Fuchiwaki, Masaki;Shimizu, Fumio;Inoue, Akira
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.76-83
    • /
    • 2011
  • This study highlights especially the mechanism of vortex cavitation occurrence from the end of the suction duct in a double-suction volute pump and pump oscillation which causes cavitation noise from the pump. In this study, full 3D numerical simulations have been performed using a commercial code inside the pump from the inlet of suction duct to the outlet of delivery duct. The numerical model is based on a combination of multiphase flow equations with the truncated version of the Rayleigh-Plesset model predicting the complicated growth and collapse process of cavity bubbles. The experimental investigations have also been performed on the cavitating flow with flow visualization to evaluate the numerical results.

Effects of vortex generators on the wind load of a flat roof: A computational study

  • Zhao, Yagebai;Deng, Xiaolong;Zhang, Hongfu;Xin, Dabo;Liu, Zhiwen
    • Wind and Structures
    • /
    • 제32권1호
    • /
    • pp.1-9
    • /
    • 2021
  • Vortex generators are commonly used in mechanical engineering and the aerospace industry to suppress flow separation owing to their advantages of simple structure, economic viability, and high level of efficiency. Owing to the flow separation of the incoming wind on the leading edge, a suction area is formed on the roof surface, which results in a lifting effect on the roof. In this research, vortex generators were installed on the windward surface of a flat roof and used to disturb to roof flow field and reduced suction based on flow control theory. Computational fluid dynamics (CFD) simulations were performed in this study to investigate the effects of vortex generators on reduce suction. It was determined that when the vortex generator was installed on the top of the roof on the windward surface, it had a significant control effect on reduce suction on the roof leading edge. In addition, the influence of parameters such as size, placement interval, and placement position of the vortex generator on the control effect of the roof's suction is also discussed.

입자 석션유동에 따른 레이저 표면가공의 마이크로 흄 오염입자 산포 특성 해석연구 (Numerical Simulation on Dispersion of Fume Micro-Particles by Particle Suction Flows in Laser Surface Machining)

  • 김경진
    • 반도체디스플레이기술학회지
    • /
    • 제22권4호
    • /
    • pp.1-6
    • /
    • 2023
  • In CO2 laser surface machining of plastic films in modern display manufacturing, scattering of fume particles could be a major source of well-recognized film surface contamination. This computational fluid dynamics research investigates the suction air flow patterns over a film surface as well as the dispersion of micron-sized fume particles with low-Reynolds number particle drag model. The numerical results show the recirculatory flow patterns near laser machining point on film surface and also over the surface of vertical suction slot, which may hinder the efficient removal of fume particles from film surface. The dispersion characteristics of fume particles with various particle size have been tested systematically under different levels of suction flow intensity. It is found that suction removal efficiency of fume particles heavily depends on the particle size in highly nonlinear manners and a higher degree of suction does not always results in more efficient particle removal.

  • PDF

Hall Effect on Unsteady Hartmann Flow with Heat Transfer Under Exponential Decaying Pressure Gradient

  • Attia Hazem A.
    • Journal of Mechanical Science and Technology
    • /
    • 제20권8호
    • /
    • pp.1302-1308
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer taking the Hall effect into consideration. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to an exponential decaying pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the ion slip and the uniform suction and injection on both the velocity and temperature distributions is examined.

Standardization of Bronchoalveolar Lavage Method Based on Suction Frequency Number and Lavage Fraction Number Using Rats

  • Song, Jeong-Ah;Yang, Hyo-Seon;Lee, Jin-Soo;Kwon, Soon-Jin;Jung, Kyung-Jin;Heo, Jeong-Doo;Cho, Kyu-Hyuk;Song, Chang-Woo;Lee, Kyu-Hong
    • Toxicological Research
    • /
    • 제26권3호
    • /
    • pp.203-208
    • /
    • 2010
  • Bronchoalveolar lavage (BAL) is a useful tool in researches and in clinical medicine of lung diseases because the BAL fluid contains biochemical and cytological indicators of the cellular response to infection, drugs, or toxicants. However, the variability among laboratories regarding the technique and the processing of the BAL material limits clinical research. The aim of this study was to determine the suction frequency and lavage fraction number necessary to reduce the variability in lavage using male Sprague-Dawley rats. We compared the total cell number and protein level of each lavage fraction and concluded that more cells and protein can be obtained by repetitive lavage with a suction frequency of 2 or 3 than by lavage with a single suction. On the basis of total cell recovery, approximately 70% of cells were obtained from fractions 1~3. The first lavage fraction should be used for evaluation of protein concentration because fractions 2~5 of lavage fluid were diluted in manifolds. These observations were confirmed in bleomycin-induced inflamed lungs of rats. We further compared the BAL data from the whole lobes with data from the right lobes and concluded that BAL data of the right lobes represented data of the whole lobes. However, this conclusion can only be applied to general lung diseases. At the end, this study provides an insight into the technical or analytical problems of lavage study in vivo.

회전 운동이 이젝터 성능에 미치는 영향에 관한 연구 (Study on the Swirling Motion Effect of Ejector Performance)

  • 강상훈;박영철
    • 한국산학기술학회논문지
    • /
    • 제18권4호
    • /
    • pp.544-549
    • /
    • 2017
  • 본 논문은 오존 방식 선박평형수 처리의 핵심 장치인 이젝터에 대하여 회전 운동하는 구동 유체가 기체-액체 이젝터의 효율에 미치는 영향에 관한 연구이다. 이젝터는 오존을 구동 노즐을 통해 분사되는 고압 액체(선박평형수)와 주변부의 저압 기체 간의 운동량 교환으로 발생되는 부압에 의해 기체(오존)를 흡입시키는 장치이다. 기존의 이젝터는 단순한 형태로 구동 유체가 분사되지만, 본 논문에서는 구동 노즐부에 회전 유도장치를 적용하여 구동 유체가 회전 운동하며 분사될 수 있도록 한다. 구동 유체의 회전 운동 유무에 따른 유동 특성을 파악하기 위하여 전산유체해석을 이용하였으며, 구동 유체의 압력과 유량, 흡입부에 발생하는 흡입 유체의 부압과 흡입 유량, 그리고 토출 압력이 예측되었다. 그 결과를 바탕으로 회전유도 장치가 적용된 이젝터의 효율은 22.25%로 산출되었으며, 구동 유체의 회전 운동이 없는 이젝터에 비해 약 1.7%의 효율이 향상되었다. 마지막으로 전산유체해석의 타당성을 검증하고자 실험 장치를 구축하여 회전 유도 장치가 적용된 이젝터에 대한 실험을 수행하였으며, 전산유체해석 결과와 비슷한 결과를 얻을 수 있었다.

고정된 분포 분사/흡입을 통한 채널 유동의 저항 감소 (Drag reduction in channel flow using stationary distributed blowing and suction)

  • 김주현;최해천
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2006년 제4회 한국유체공학학술대회 논문집
    • /
    • pp.195-198
    • /
    • 2006
  • The possibility of skin friction reduction in laminar channel flow is investigated when the flow is subjected to stationary distributed surface blowing and suction. Blowing and suction provided at the channel walls is steady in time but varies as a sine function along the streamwise direction. The skin friction changes depending on the wavelength and amplitude of the actuation. Especially, the skin friction is reduced below that of fully developed laminar flow as the wavelength decreases and amplitude increases. The optimal wavelength of producing minimum skin friction is $\pi/2{\delta}$, where $\delta$ is the channel half-height It is observed that the distributed blowing and suction induces strong negative Reynolds shear stress in the near-wall region at the end of the suction part.

  • PDF

코안다 효과를 이용한 에어 블로어와 흡입구의 유동 제어 (Flow control of air blowing and vacuuming module using Coanda effect)

  • 정우태
    • 한국산학기술학회논문지
    • /
    • 제18권3호
    • /
    • pp.115-121
    • /
    • 2017
  • 도시철도 터널 내에 축적된 미세먼지(PM10 and PM2.5)의 제거를 위해 사용되는 분진흡입차량은 에어 블로어와 흡입시스템으로 구성된 하부흡입시스템의 설계방법에 따라 성능이 달라진다. 본 논문에서는 터널 집진차량의 하부에 설치된 먼지 흡입시스템의 효율 향상을 위하여 흡입구와 에어 블로어에 코안다 효과를 이용한 유속 조절장치를 적용하여 그 효과를 확인하였다. 특히, 공기 유동에 대한 수치해석을 통하여 진공 흡입구 내에 코안다 효과를 이용한 유속조절장치를 적용하였으며, 유속 조절각이 약 90도 내외일 때 유속의 상승과 더불어 유동의 안정화가 동시에 이루어질 수 있음을 확인하였다. 또한 링 블로어에 의해 동작되는 에어 나이프형 공기 블로어는 양쪽 끝 가장자리에 코안다 효과를 유도할 수 있는 엣지 구조를 삽입함으로써 블로어 양 끝단의 유속 저하를 개선할 수 있음을 확인하였다. 이러한 4개의 통합된 모듈 형식의 흡입 시스템의 설계는 최적화를 통하여 바닥 먼지가 비산됨과 동시에 흡입구로 흡입되어 궤도면에 누적된 미세먼지와 초미세먼지의 제거에 효과적으로 활용될 수 있을 것으로 기대된다.