DOI QR코드

DOI QR Code

Flow control of air blowing and vacuuming module using Coanda effect

코안다 효과를 이용한 에어 블로어와 흡입구의 유동 제어

  • Jeong, Wootae (Transportation Environmental Research Team, Korea Railroad Research Institute)
  • 정우태 (한국철도기술연구원 교통환경연구팀)
  • Received : 2017.02.08
  • Accepted : 2017.03.10
  • Published : 2017.03.31

Abstract

The efficiency of railway track cleaning vehicle for eliminating fine particulate matter (PM10 and PM2.5) in a subway tunnel depends strongly on the structure of the air blowing and suction system installed under the train. To increase the efficiency of underbody suction system, this paper proposes a novel method to use the Coanda effect for the air blower and dust suction module. In particular, through Computational Fluid Dynamics (CFD) analysis, the flow control device induced by the Coanda effect enables an increase in the overall flow velocity and to stabilize the flow distribution of the suction module at a control angle of $90^{\circ}$. In addition, the flow velocity drop at the edge of the air knife-type blower can be improved by placing small inserts at the edge of the blower. Those 4 modular designs of the dust suction system can help remove the dust accumulated on the track and tunnel by optimizing the blowing and suction flows.

도시철도 터널 내에 축적된 미세먼지(PM10 and PM2.5)의 제거를 위해 사용되는 분진흡입차량은 에어 블로어와 흡입시스템으로 구성된 하부흡입시스템의 설계방법에 따라 성능이 달라진다. 본 논문에서는 터널 집진차량의 하부에 설치된 먼지 흡입시스템의 효율 향상을 위하여 흡입구와 에어 블로어에 코안다 효과를 이용한 유속 조절장치를 적용하여 그 효과를 확인하였다. 특히, 공기 유동에 대한 수치해석을 통하여 진공 흡입구 내에 코안다 효과를 이용한 유속조절장치를 적용하였으며, 유속 조절각이 약 90도 내외일 때 유속의 상승과 더불어 유동의 안정화가 동시에 이루어질 수 있음을 확인하였다. 또한 링 블로어에 의해 동작되는 에어 나이프형 공기 블로어는 양쪽 끝 가장자리에 코안다 효과를 유도할 수 있는 엣지 구조를 삽입함으로써 블로어 양 끝단의 유속 저하를 개선할 수 있음을 확인하였다. 이러한 4개의 통합된 모듈 형식의 흡입 시스템의 설계는 최적화를 통하여 바닥 먼지가 비산됨과 동시에 흡입구로 흡입되어 궤도면에 누적된 미세먼지와 초미세먼지의 제거에 효과적으로 활용될 수 있을 것으로 기대된다.

Keywords

References

  1. L. M. Brosseau, et al., "Dust cleaning: a review of associated health effects and results of company and expert surveys", ASHRAE Trans., vol. 106, pp. 180-187, 2000.
  2. M. Kim, et al., "Evaluation of passenger health risk assessment of sustainable indoor air quality monitoring in metro systems based on a non-Gaussian dynamic sensor validation method", Journal of Hazardous Materials, vol. 278, pp. 124-133, 2014. DOI: https://doi.org/10.1016/j.jhazmat.2014.05.098
  3. S.-B. Kwon, et al., "Study on the indoor air quality of Seoul metropolitan subway during the rush hour", Indoor and Built Environment, vol. 17, pp. 361-369, 2008. DOI: https://doi.org/10.1177/1420326X08094683
  4. C. M. Ma, et al., "Chemical Properties and Source Profiles of Particulate Matter Collected on an Underground Subway Platform", Asian Journal of Atmospheric Environment, vol. 9, no. 2, pp. 165-172, June, 2015. DOI: https://doi.org/10.5572/ajae.2015.9.2.165
  5. Y. H. Cheng and Y. L. Lin, "Measurement of Particle Mass Concentrations and Size Distributions in an Underground Station", Aerosol and Air Quality Research, vol. 10, pp. 22-29, 2010. DOI: https://doi.org/10.4209/aaqr.2009.05.0037
  6. D. Park, et al., "Identification of the source of PM10 in a subway tunnel using positive matrix factorization", Journal of the Air & Waste Management Association, vol. 64, no. 12, pp. 1361-1368, 2014. DOI: https://doi.org/10.1080/10962247.2014.950766
  7. W. C. Hinds, "Aerosol technology: properties, behavior, and measurement of airborne particles", A Wiley Interscience Publication, 2012.
  8. W. Jeong, et al., "Dust collection system optimization with air blowing and dust suction module", Journal of the Korea Academia-Industrial Cooperation Society, vol. 17, no. 1, pp. 290-297, 2016. DOI: https://doi.org/10.5762/KAIS.2016.17.1.290
  9. H. Coanda, "Device for Deflecting a Stream of Elastic Fluid Projected into an Elastic Fluid", US Patent Office, US Patent # 2,052,869. 1936.
  10. I. Reba, "Applications of the Coanda effect", Scientific American. vol. 214, no. 6, pp. 84-921, 1996. DOI: https://doi.org/10.1038/scientificamerican0666-84
  11. M. Kadosch, "The curved wall effect", 2nd Cranfield Fluidics Conference, Cambridge, 1967.