• 제목/요약/키워드: Suction fluid

검색결과 321건 처리시간 0.022초

원심펌프 측면흡입구의 유동특성에 관한 수치해석적 연구 (A Numerical Study on the Flow Characteristics of Side-suction Inlet Geometry for Centrifugal Pump)

  • 김성;최영석;이경용
    • 한국유체기계학회 논문집
    • /
    • 제12권6호
    • /
    • pp.7-12
    • /
    • 2009
  • This paper presents a numerical study on the design of side-suction inlet geometry which is used for multi stage centrifugal pumps or inline centrifugal pumps. In order to achieve an optimum inlet geometry and to explain the interactions between the different geometric configurations, the three dimensional computational fluid dynamics and the design of experiment methods have been applied. Geometric design variables describing the cross sectional area distribution through the inlet were selected. The objective functions are defined as the non-uniformity of the velocity distribution at the passage exit which is just in front of the impeller eyes. From the 2k factorial design results, the most important design variable was found and the performance of the side suction inlet was improved compared to the base line shape.

UNSTEADY HARTMANN FLOW WITH HEAT TRANSFER IN THE PRESENCE OF UNIFORM SUCTION AND INJECTION

  • Attia Hazem A.
    • 한국수학교육학회지시리즈B:순수및응용수학
    • /
    • 제13권1호
    • /
    • pp.1-10
    • /
    • 2006
  • The unsteady Hartmann flow of an electrically conducting, viscous, incompressible fluid bounded by two parallel non-conducting porous plates is studied with heat transfer. An external uniform magnetic field and a uniform suction and injection are applied perpendicular to the plates while the fluid motion is subjected to a constant pressure gradient. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the magnetic field and the uniform suction and injection on both the velocity and temperature distributions is examined.

  • PDF

보조 인듀서가 터보펌프의 흡입성능에 미치는 영향 (Effect of a Booster Inducer on the Suction Performance of Turbopumps)

  • 최창호;홍순삼;김진한
    • 한국유체기계학회 논문집
    • /
    • 제8권3호
    • /
    • pp.42-47
    • /
    • 2005
  • Effects of a booster inducer on the suction performance of turbopumps are investigated in this paper. To see the effect of the booster inducer, suction performance tests are conducted with and without the booster inducer for three turbopumps. It is shown that the booster inducer can enhance the suction performance of turbopumps when the tip clearance of the main inducers are relatively large. Numerical analysis are also carried out to see the effects of the booster inducer on the performance of the main inducer. The booster inducer is shown to increase the static pressure at the inlet of the main inducer and prevent growing of inlet back flows which are believed to have deleterious effects on the suction performance of the inducer.

HALL EFFECTS ON HYDROMAGNETIC NATURAL CONVECTION FLOW IN A VERTICAL MICRO-POROUS-CHANNEL WITH INJECTION/SUCTION

  • BHASKAR, P.;VENKATESWARLU, M.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제24권1호
    • /
    • pp.103-119
    • /
    • 2020
  • In this work, the hydromagnetic and thermal characteristics of natural convection flow in a vertical parallel plate micro-porous-channel with suction/injection is analytically studied in the presence of Hall current by taking the temperature jump and the velocity slip at the wall into account. The governing equations, exhibiting the physics of the flow formation are displayed and the exact analytical solutions have been obtained for momentum and energy equations under relevant boundary conditions. The impact of distinct admissible parameters such as Hartmann number, Hall current parameter, permeability parameter, suction/injection parameter, fluid wall interaction parameter, Knudsen number and wall-ambient temperature ratio on the flow formation is discussed with the aid of line graphs. In particular, as rarefaction parameter on the micro-porous-channel surfaces increases, the fluid velocity increases and the volume flow rate decreases for injection/suction.

인듀서 익단간극이 터보펌프용 펌프의 흡입성능에 미치는 영향 (Effects of Inducer Tip Clearance on the Suction Performance of a Pump for Turbopumps)

  • 최창호;김대진;김진한
    • 한국유체기계학회 논문집
    • /
    • 제15권1호
    • /
    • pp.41-45
    • /
    • 2012
  • The effects of inducer tip clearance on the suction performance of a pump for turbopumps are investigated. Experiments for the pump with inducer tip clearances of 1.8% and 1.4% of blade height were performed. The experimental results showed that the suction performance of the pump increased as the tip clearance decreased. It seems that the suction performance of the pump becomes better with smaller tip clearances because the strength of the inducer backflow becomes weak with the decreased tip clearance.

A model of roof-top surface pressures produced by conical vortices : Evaluation and implications

  • Banks, D.;Meroney, R.N.
    • Wind and Structures
    • /
    • 제4권4호
    • /
    • pp.279-298
    • /
    • 2001
  • The greatest suction on the cladding of flat roof low-rise buildings is known to occur beneath the conical vortices that form along the roof edges for cornering winds. In a companion paper, a model of the vortex flow mechanism has been developed which can be used to connect the surface pressure beneath the vortex to adjacent flow conditions. The flow model is experimentally validated in this paper using simultaneous velocity and surface pressure measurement on a 1 : 50 model of the Texas Tech University experimental building in a wind tunnel simulated atmospheric boundary layer. Flow visualization gives further insight into the nature of peak suction events. The flow model is shown to account for the increase in suction towards the roof corner as well as the presence of the highest suction at wind angles of $60^{\circ}$. It includes a parameter describing vortex suction strength, which is shown to be related to the nature of the reattachment, and also suggests how different components of upstream turbulence could influence the surface pressure.

흡입공기 온도에 의한 용적형 공기 압축기 성능 변화 (Effect of the Suction Air Temperature on the Performance of a Positive Displacement Air Compressor)

  • 장지성;한승훈;지상원
    • 동력기계공학회지
    • /
    • 제21권2호
    • /
    • pp.89-94
    • /
    • 2017
  • Pneumatic systems are widely applied in various industry because it have a many advantage(low cost, high safety, etc.). Air compressors supply the working fluid to the pneumatic systems and consume a lot of electrical energy at the manufacturing site. The one of the suggested idea is to reduce the energy consumption by reducing the suction temperature of the air compressor and increasing the discharge flow rate. In this paper, the discharge flow rate and air power of the positive displacement type air compressor is simulated by changing the temperature of suction air and the relationship between the suction air temperature and the performance variation of the air compressor is analyzed. As a result, we know that as the suction temperature of air is lowered, the discharge mass flow-rate is increased, but the specific enthalpy is reduced rather than increased, which means that the power of the discharged air is not greatly increased even if lower the suction air temperature.

수술시 뇌종양 흡인액의 세포학적 검사의 유용성 (Usefulness of Cytologic Study of Intraoperative Suction Fluid in Brain Tumors)

  • 이혜경;이형진;이은희;김희정;이일우
    • 대한세포병리학회지
    • /
    • 제13권2호
    • /
    • pp.66-69
    • /
    • 2002
  • In diagnosing a brain tumor, it is essential to obtain samples from many areas of the tumor. Although there are reports about the suitability of material obtained by cavitron ultrasonic surgical aspirator(CUSA), there is a paucity of reports regarding conventional intraoperative suction. This study was performed to evaluate the usefulness of the suction fluid and the effect of different hemolytic fixatives. Intraoperative suction fluid was obtained from 2 pituitary adenomas and 2 choroid plexus carcinomas. In two cases of mixed astro-oligodendroglioma, one of glioblastoma multiforme and 3 of meningioma, the fluid was collected by CUSA. Each sample was divided into four bottles for the different fixatives such as 0.1N HCI, 10% acetic acid, 95% alcohol, and no additive. All cases were evaluated by the both cytologic smear and cell block preparations, and were reviewed with concomitant histologic diagnosis. The result showed a good correlation between the cytologic study and the histologic diagnosis and 95% alcohol was found to be superior to other fixatives in ceil preservation.

Closed-Suction Drainage and Cerebrospinal Fluid Leakage Following Microvascular Decompression : A Retrospective Comparison Study

  • Kim, Young-Hoon;Han, Jung Ho;Kim, Chae-Yong;Oh, Chang Wan
    • Journal of Korean Neurosurgical Society
    • /
    • 제54권2호
    • /
    • pp.112-117
    • /
    • 2013
  • Objective : We performed this study to investigate whether the use of closed-suction drainage following microvascular decompression (MVD) causes cerebrospinal fluid (CSF) leakage. Methods : Between 2004 and 2011, a total of 157 patients with neurovascular compression were treated with MVD. MVD was performed for hemifacial spasm in 150 (95.5%) cases and for trigeminal neuralgia in 7 (4.5%) cases. The mean age of the patients was $49.8{\pm}9.6$ years (range, 20-69). Dural substitutes were used in 44 (28.0%) patients. Ninety-two patients (58.6%) were underwent a 4-5 cm craniotomy using drainage (drainage group), and 65 (41.4%) did a small 2-2.5 cm retromastoid craniectomy without closed-suction drainage (no-drainage group). Results : Eleven (7.0%) patients experienced CSF leakage following MVD based on the criteria of this study; all of these patients were in the drainage group. In the unadjusted analyses, the incidence of CSF leakage was significantly related with the use of closed-suction drainage following MVD (12.0% in the drainage group vs. 0% in the no-drainage group, respectively; p=0.003; Fisher's exact test). Those who received dural substitutes and the elderly (cut-off value=60 years) exhibited a tendency to develop CSF leakage (p=0.075 and p=0.090, respectively; Fisher's exact test). In the multivariate analysis, only the use of closed-suction drainage was significantly and independently associated with the development of CSF leakage following MVD (odds ratio=9.900; 95% confidence interval, 1.418 to infinity; p=0.017). Conclusion : The use of closed-suction drainage following MVD appears to be related to the development of CSF leakage.

인듀서의 크기가 터보펌프의 흡입성능 상사에 미치는 영향에 관한 연구 (Put Effect of the inducer scale on the suction performance similarity of a turbopump)

  • 강병윤;강신형
    • 한국유체기계학회 논문집
    • /
    • 제17권4호
    • /
    • pp.47-52
    • /
    • 2014
  • An inducer is forward-attached to an impeller to improve the suction performance. This paper described the experimental and numerical investigations on the concept of NPSH similarity about the inducer scale. As Reynolds number decreased for the same scale inducer, the hydraulic performance is slightly reduced because of the viscosity. The suction performance similarity is in good agreement. For different scale inducers, the NPSH similarity did not follow the conventional rule which is proportional to the square of the inducer diameter. A cavity of two times scale inducer grows faster under cavitation inception, and the head is more drop as the fluid passes blades. Because of the simplified cavitation model and vapor pressure, the NPSH similarity dose not have an accuracy. This study suggested an empirical formula for the NPSH similarity.