Abstract

Pneumatic systems are widely applied in various industry because it have a many advantage(low cost, high safety, etc.). Air compressors supply the working fluid to the pneumatic systems and consume a lot of electrical energy at the manufacturing site. The one of the suggested idea is to reduce the energy consumption by reducing the suction temperature of the air compressor and increasing the discharge flow rate. In this paper, the discharge flow rate and air power of the positive displacement type air compressor is simulated by changing the temperature of suction air and the relationship between the suction air temperature and the performance variation of the air compressor is analyzed. As a result, we know that as the suction temperature of air is lowered, the discharge mass flow-rate is increased, but the specific enthalpy is reduced rather than increased, which means that the power of the discharged air is not greatly increased even if lower the suction air temperature.

Keywords

References

  1. M. Masaki, 2005, "Air Compressor", Energy Saving Center, Tokyo, pp. 31-33.
  2. T. Takahashi, 1996, "Energy Saving for Pneumatic Systems", Journal of the Japan Hydraulics and Pneumatics Society, Vol. 27, No. 3, pp. 362-365.
  3. YuJin Machinery Ltd., 2014, "Development of Oil Free Screw Inverter Compressor", Small and Medium Business Administration, Research Report, Korea.
  4. J. JUN, 2014, "Flexible Air Cooling Device for Air Compressor", Korea Patent 1013608600000.
  5. SimulationX R3.6, 2015, "Pneumatics Library Manual", ITI Gmbh, Germany, pp. 165-169.
  6. LMS Amesim R14, 2015, "Two-phase Flow Libray Manual", Siemens Industry Software Ltd., Germany, pp. 97-102.
  7. ISO/TC 131, 2003, "ISO 8778 Pneumatic Fluid Power - Standard Reference Atmosphere", International Organization for Standardization.
  8. J. Jang, 2015, "The effect of parameter changes on the properties of an air spring", Journal of the Korean Society for Power System Engineering, Vol. 17, No. 1, pp. 64-68.
  9. ISO/TC 131, 1996, "Displacement Compressors- Acceptance Tests", International Organization for Standardization.

Cited by

  1. 공기압축기 소비에너지 평가에 관한 연구 vol.17, pp.2, 2017, https://doi.org/10.7839/ksfc.2020.17.2.038