• 제목/요약/키워드: Suction Pressure

검색결과 686건 처리시간 0.022초

EFFECT OF POROSITY ON THE TRANSIENT MHD GENERALIZED COUETTE FLOW WITH HEAT TRANSFER IN THE PRESENCE OF HEAT SOURCE AND UNIFORM SUCTION AND INJECTION

  • Attia, Hazem Ali;Ewis, Karem Mahmoud;Awad-Allah, Nabil Ahmed
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제16권2호
    • /
    • pp.125-135
    • /
    • 2012
  • The transient magnetohydrodynamic (MHD) generalized Couette flow with heat transfer through a porous medium of an electrically conducting, viscous, incompressible fluid bounded by two parallel insulating porous plates is studied in the presence of uniform suction and injection and a heat source considering the Hall effect. A uniform and constant pressure gradient is imposed in the axial direction and an externally applied uniform magnetic field as well as a uniform suction and injection are applied in the direction perpendicular to the plates. The two plates are kept at different but constant temperatures while the Joule and viscous dissipations are included in the energy equation. The effect of the Hall current, the porosity of the medium and the uniform suction and injection on both the velocity and temperature distributions is investigated.

벤토나이트에 근입된 앵커의 흡입력에 관한 실험적 연구 (An Experimental Study on Suction Force of Plate Anchor Embedded in Bentonite)

  • 이준대
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.97-102
    • /
    • 2001
  • Anchors are often used in construction of foundations such as transmission towers to resist uplifting forces. When plate anchors are embedded in soft clay, they may undergo a deformation under the pressure of sustained load. In soft saturated clays, the suction force can be a large par of the ultimate uplift capacity. This study is to present recent laboratory model test results conducted to evaluate the nature of variation of the suction force for plate anchors with shear strength and embedment ratio. The ratio of F$_{s}$Q$_{n}$ versus H/D in bentonite decreases with the increase of the embedment ratio.o.o.

  • PDF

A simplified method to estimate the total cohesion of unsaturated soil using an UC test

  • Lin, Horn-Da;Wang, Chien-Chih;Wang, Xu-Hui
    • Geomechanics and Engineering
    • /
    • 제16권6호
    • /
    • pp.599-608
    • /
    • 2018
  • This study investigates the feasibility of adopting the results of the UC (unconfined compression) test to assess the total cohesion of the unsaturated soil. A series of laboratory tests were conducted on samples of unsaturated lateritic soils of northern Taiwan. Specifically, the unconfined compression test was combined with the pressure plate test to obtain the unconfined compression strength and its matric suction of the samples. Soil samples were first compacted at designated water content and then subjected to the wetting process for saturation and the subsequent drying process to its target suction using the apparatus developed by the authors. The correlations among the matric suction, the unconfined compression strength and the total cohesion were studied. As a result, a simplified method to estimate the total cohesion using the unconfined compressive strength is suggested. The calculated results compare reasonably with the unsaturated triaxial test results. Current results show good performance; however, further study is warranted.

편마풍화토의 다짐밀도에 따른 불포화 흡수응력 특성 (Density Effect on Suction Stress Characteristics of Compacted Weathered Gneiss Soils)

  • 박성완;김병수;권홍기;임재성
    • 한국지반공학회논문집
    • /
    • 제29권8호
    • /
    • pp.15-25
    • /
    • 2013
  • 본 연구에서는 다짐된 편마풍화토의 불포화토 전단강도특성을 규명하기 위하여, Constant Water Content Compression (CWCC) 시험을 실시하였다. 두 가지 상대밀도로 구분하여 정적 다짐으로 공시체가 제작되었고, 초기 포화도를 변화시킴으로써 초기 흡수력 및 최대전단강도가 구현될 때의 흡수력에 따른 전단거동을 살펴보았다. 흡수력은 세라믹디스크와 간극수압계의 설치에 의해 직접 측정되었고, 이 흡수력을 적용하여 흡수응력(ps)이 추정되었다. CWCC 시험에서 얻어진 최대압축강도에 대한 결과는 삼축압축시험에서의 포화상태 파괴선(Mp Line)과의 관계, 즉 흡수력에 의해 발현된 전단강도의 변화를 흡수응력을 이용하여 살펴보았다. 또한, Kim 등(2010)이 제안한 Suction stress-SWCC Method (SSM)을 활용하여 흡수응력의 적용성에 대해 논하였다.

평균골격응력을 이용한 불포화토의 탄-점소성 구성방정식 (Elasto-viscoplastic Constitutive Model of Unsaturated Soil based on Average Skeleton Stress)

  • 김영석
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1199-1203
    • /
    • 2008
  • It has been recognized that unsaturated soil behavior plays an importantrole in geomechanics. In the last decade several constitutive models have been proposed and used in the analysis. Many of them, however, are constructed in the frame work of rate independent model such as elasto-plastic one. Although rate dependency is an important characteristics of soil for both saturated and unsaturated soils, very few models have been developed taking account of rate dependency. In the present paper, we have developed an elasto-viscoplastic model considering an effect of suction based on the overstress-type viscoplasticity with soil structure degradation. In the model, we have adopted an averaged pore pressure composed of pore water pressure and air pressure to determine the effective stress.

  • PDF

Tip Clearance Effects on Inlet Hot Streaks Migration Characteristics in Low Pressure Stage of a Vaneless Counter-Rotating Turbine

  • Zhao, Qingjun;Wang, Huishe;Zhao, Xiaolu;Xu, Jianzhong
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2008년 영문 학술대회
    • /
    • pp.25-34
    • /
    • 2008
  • In this paper, three-dimensional multiblade row unsteady Navier-Stokes simulations at a hot streak temperature ratio of 2.0 have been performed to reveal the effects of rotor tip clearance on the inlet hot streak migration characteristics in low pressure stage of a Vaneless Counter-Rotating Turbine. The hot streak is circular in shape with a diameter equal to 25% of the high pressure turbine stator span. The hot streak center is located at 50% of the span and the leading edge of the high pressure turbine stator. The tip clearance size studied in this paper is 2.0mm(2.59% high pressure turbine rotor height, and 2.09% low pressure turbine rotor height). The numerical results show that the hot streak is not mixed out by the time it reaches the exit of high pressure turbine rotor. The separation of colder and hotter fluid is observed at the inlet of low pressure turbine rotor. Most of hotter fluid migrates towards the rotor pressure surface, and only little hotter fluid migrates to the rotor suction surface when it convects into the low pressure turbine rotor. And the hotter fluid migrated to the tip region of the high pressure turbine rotor impinges on the leading edge of the low pressure turbine rotor after it goes through the high pressure turbine rotor. The migration of the hotter fluid directly results in very high heat load at the leading edge of the low pressure turbine rotor. The migration characteristics of the hot streak in the low pressure turbine rotor are dominated by the combined effects of secondary flow and leakage flow at the tip clearance. The leakage flow trends to drive the hotter fluid towards the blade tip on the pressure surface and to the hub on the suction surface, even partial hotter fluid near the pressure surface is also driven to the rotor suction surface through the tip clearance. Compared with the case without rotor tip clearance, the heat load of the low pressure turbine rotor is intensified due to the effects of the leakage flow. And the numerical results also indicate that the leakage flow effect trends to increase the low pressure turbine rotor outlet temperature at the tip region.

  • PDF

완전 무치악 환자에서 하악 흡착 의치를 통한 총의치 수복 증례 (Complete denture rehabilitation of edentulous patient using mandibular suction denture: a clinical report)

  • 임서련;서윤희;김현영;송영균;이준석
    • 대한치과보철학회지
    • /
    • 제52권4호
    • /
    • pp.346-351
    • /
    • 2014
  • 흡착 의치는 의치상연 주위 전체를 가동 점막으로 봉쇄하여 연하나 교합 시 의치상 내면에 일시적으로 음압을 형성하여 의치의 유지와 안정을 강화한다. 본 증례의 환자는 81세의 남자 환자로 새로운 의치를 제작하고 싶다는 주소로 내원하였다. 의치의 유지와 저작 효율에 대한 환자의 높은 요구도를 고려하여 흡착 의치를 통한 총의치 제작을 계획하였다. 하악 후구치 융기 부위를 가압하지 않은 채로 예비 인상을 채득 후 상하악 진단모형을 제작하였다. 이후 개인 트레이 제작 후 최종 인상 채득과 동시에 고딕 아치 기록을 시행하여 중심위 및 수직 고경을 채득하였으며, 상악에는 해부학적 치아, 하악에는 비해부학적 치아를 배열하여 설측 교합을 형성하였다. 이상과 같이 완전 무치악 환자에서 하악 흡착 의치를 통한 총의치 수복은 만족스러운 유지와 기능을 회복할 수 있었기에 본 증례를 보고하고자 한다.

치조제 흡수가 심한 무치악 환자에서 흡착원리를 이용한 총의치 수복 증례 (Complete denture fabrication of edentulous patient with severe alveolar bone resorption using suction mechanism: A case report)

  • 김현아;윤귀덕;조유진;양홍서;박상원;박찬
    • 대한치과보철학회지
    • /
    • 제58권2호
    • /
    • pp.130-136
    • /
    • 2020
  • 흡착원리를 이용한 총의치 제작은 연하나 저작 등의 운동 시 의치 내면의 음압이 형성되어 의치연 주변의 봉쇄를 이루어 유지와 안정을 향상시키고자 소개된 방식이다. 하악 흡착의치는 특히 변형되기 쉬운 후구치융기를 안정 상태에서 채득하여 개구 시 탈락력을 감소시킨다. 이 증례에서는 하악 치조제 흡수가 심한 무치악 환자에서 흡착원리를 통한 총의치 제작을 통해 의치의 향상된 유지력과 안정 및 환자의 만족도를 얻었다.

이젝터 흡입관의 유동장 분석에 관한 연구 (Study on Analysis of Flow Field in Ejector Suction Pipe)

  • 김노형
    • 대한기계학회논문집B
    • /
    • 제36권10호
    • /
    • pp.989-999
    • /
    • 2012
  • 이젝터는 고압의 유체를 구동관로에서 분출시켜, 그 주변의 저압기체와 운동량 교환을 통하여 저압의 유체를 보다 높은 압력까지 상승시켜 흡인되는 유체를 이송하는 장치이다. 증기-증기 이젝터는 흡입, 혼합 및 탈수에 널리 사용되고 있다. 그리고 이젝터는 기계적인 작동이 없으므로, 고장이 거의 없다. 또한 이젝터는 유체 관련 시스템의 크기에 관계없이 유체와 관련된 다양한 장소에 용이하게 설치할 수 있어, 정비의 필요성이 거의 없고 비용도 합리적이다. 따라서 본 연구는 단순 압축 또는 진공 설비를 위한 펌프 혹은 기계장치 대안으로 사용되는 이젝터 전체에 적용할 수 있는 기초 자료 제공을 목표로 하였다. 이 목표를 위해 실험만으로 획득할 수 없는 자료를 전산유체역학을 적용하여 분석함으로써 이젝터의 유체역학적 특성에 있어 최적의 설계조건을 제시하였다.

Influence of Negative-Pressure Wound Therapy on Tissue Oxygenation of the Foot

  • Shon, Yoo-Seok;Lee, Ye-Na;Jeong, Seong-Ho;Dhong, Eun-Sang;Han, Seung-Kyu
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.668-672
    • /
    • 2014
  • Background Negative-pressure wound therapy (NPWT) is believed to accelerate wound healing by altering wound microvascular blood flow. Although many studies using laser Doppler have found that NPWT increases perfusion, recent work using other modalities has demonstrated that perfusion is reduced. The purpose of this study was to investigate the influence of NPWT on tissue oxygenation of the foot, which is the most sensitive region of the body to ischemia. Methods Transcutaneous partial pressure of oxygen ($TcpO_2$) was used to determine perfusion beneath NPWT dressings of 10 healthy feet. The sensor was placed on the tarso-metatarsal area of the foot and the NPWT dressing was placed above the sensor. $TcpO_2$ was measured until it reached a steady plateau state. The readings obtained at the suction-on period were compared with the initial baseline (pre-suction) readings. Results $TcpO_2$ decreased significantly immediately after applying NPWT, but gradually increased over time until reaching a steady plateau state. The decrease in $TcpO_2$ from baseline to the steady state was 2.9 to 13.9 mm Hg (mean, $9.3{\pm}3.6$ mm Hg; $13.5{\pm}5.8%$; P<0.01). All feet reached a plateau within 20 to 65 minutes after suction was applied. Conclusions NPWT significantly decrease tissue oxygenation of the foot by 2.9 to 13.9 mm Hg. NPWT should be used with caution on feet that do not have adequate tissue oxygenation for wound healing.