• Title/Summary/Keyword: Subway ventilation system

Search Result 72, Processing Time 0.024 seconds

A preliminary study of Standardization Plan on Underground Air filtration Facility (지하역사 공기여과장치 표준화방안 사전연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.

  • PDF

Performance Evaluation of Wireless Sensor Networks in the Subway Station of Workroom (지하철 역사내 기능실에 대한 무선 센서 네트워크 성능 분석)

  • An, Tea-Ki;Shin, Jeong-Ryol;Kim, Gab-Young;Yang, Se-Hyun;Choi, Gab-Bong;Sim, Bo-Seog
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1701-1708
    • /
    • 2011
  • A typical day in the subway transportation is used by hundreds of thousands are also concerned about the safety of the various workrooms with high underground fire or other less than in the subway users could be damaging even to be raised and there. In 2010, in fact, room air through vents in the fire because smoke and toxic gas accident victims, and train service suspended until such cases are often reported. In response to these incidents in subway stations, even if the latest IT technology, wireless sensor network technology and intelligent video surveillance technology by integrating fire and structural integrity, such as a comprehensive integrated surveillance system to monitor the development of intelligent urban transit system and are under study. In this study, prior to the application of the monitoring system into the field stations, authors carried out the ZigBee-based wireless sensor networks performance analyzation in the Chungmuro station. The test results at a communications room and ventilation room of the station are summarized and analyzed.

  • PDF

Analysis of air pollution in subway area of Busan Metropolitan City (부산광역시 지하철역 지하공간의 대기오염 특성)

  • Lee, Hwa-Woon;Jang, Nan-Sim;Kwak, Jin;Lee, Hee-Ryung;Kim, Hee-Man
    • Journal of Environmental Science International
    • /
    • v.11 no.3
    • /
    • pp.169-176
    • /
    • 2002
  • The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

Evaluation of VOCs Concentrations for Ventilation System in Subway (지하철 역사내 효과적인 환기체계 정립을 위한 휘발성유기화합물 농도 평가)

  • 조장제;장정욱;최우건;김태오;박덕신;정우성
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2003.05b
    • /
    • pp.431-432
    • /
    • 2003
  • 급속한 도시화, 인구 과밀화로 인한 교통문제와 생활공간의 확보는 현재 대도시가 직면한 사회적인 문제이다. 이와 같은 대도시의 교통문제를 해결하기 위해 건설된 지하철은 인구의 도시집중으로 인해 발생하는 교통량의 증가를 효과적으로 관리할 수 있는 유일한 운송 수단이다. 이러한 지하철의 이용공간은 밀폐성으로 인해 환기가 용이치 않고, 그로 인한 유해물질의 축적으로 인체에 대한 위해성이 대두되고 있다. 이에 본 연구에서는 지하공간 내 오염물질 중 가스상 오염물질 즉, 휘발성유기화합물질(VOCs)을 측정, 분석함으로써 지하역사내의 쾌적한 환경을 확보하기 위한 효과적인 방안을 정립하는데 일조 하고자 한다. (중략)

  • PDF

Analysis of Ambient Air Quality Level in Subway Area in Busan Metropolitan City (부산광역시 지하철 내의 대기오염도 분석)

  • Lee, Hwa-Woon;Park, Jong-Kil;Jang, Nan-Sim;Lee, Hee-Ryung;Kim, Hee Man
    • Journal of Environmental Science International
    • /
    • v.12 no.2
    • /
    • pp.207-215
    • /
    • 2003
  • The purpose of this study is to estimate the air quality of subway stations having underground platforms in Busan Metropolitan City, from September to November 2000, over seven times. The places of the investigation include Yonsan-dong station, Somyon station, Busan station, Nampo-dong station, and Dusil station. Samplings were conducted at three points in each station, i.e. gates, ticket gates, and platforms. CO, NO, $NO_2$, and $O_3$ were the main components of air for this analysis. In order to more fully understand station environments, we also measured an air temperature at each point. The results showed that the $O_3$ average concentration of Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at the ticket gate and platform at Somyon station (119 ppb, 122 ppb) and Nampo-dong station (102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls were higher than others. At Somyon station having a junction station, NO and $NO_2$ concentration levels of platform-2 (noncrowded) were higher than platform-1 (crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems. To find the relationship of the indoor (platform) and outdoor (gate), we analyzed the I/O ratio. The averages of CO and $O_3$ were both higher than one: 1.16 and 1.82, respectively. In the correlations between each material and the others, NO vs $NO_2$ was the highest with R=0.63. In the correlations between indoor and outdoor, $O_3$ was the highest with R=0.64.

LCCA and LCA to Evaluate Feasibility for Introducing High-Efficiency Motors into Air Ventilation Systems of Public Facilities (고효율 전동기를 다중이용시설 환기설비에 도입하기 위한 LCCA 및 LCA 분석)

  • Quan, Junlong;Choi, Sooho;Kwon, Taehwan;Choi, Hyemi;Kim, Juhyung;Kim, Jaejun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.4
    • /
    • pp.41-49
    • /
    • 2015
  • The amount of energy consumed in air ventilation systems of public facilities accounts for 40% of their total energy consumption. To reduce their energy consumption, applying variable speed operation controlled by an inverter with a high-efficiency motor is suggested. Since these methods require higher initial investment costs compared to the existing systems, economic evaluation should be conducted from a long-term perspective. While LCCA(Life Cycle Cost Analysis) model is useful to estimate net savings of alternatives that differs with respect to initial costs and operating costs, the environmental burdens are not considered. On the contrary LCA(Life Cycle Assesment) model is suitable to assess environmental impacts associated with the stages of a product's life but it does not consider costs. In this study, the high-efficient motors are introduced into the air ventilation system of a subway station and a comprehensive analysis on the economic and environmental impacts of the proposed method is conducted by using LCCA and LCA model.

Experimental Study for the Capacity of Ordinary and Emergency Ventilation System in Deeply Underground Subway Station (대심도 지하역사 승강장 및 대합실 평상시/비상시 급·배기 풍량에 대한 실험적 연구)

  • Jang, Yong-Jun;Lee, Ho-Seok;Park, Duck-Shin
    • Journal of the Korean Society for Railway
    • /
    • v.15 no.6
    • /
    • pp.579-587
    • /
    • 2012
  • Shin-gumho station in Seoul underground subway have been selected to be experimentally investigated and analyzed for the real air supply & exhaust capacity compared to the original capacity of ordinary and emergency condition. The depth of Shin-gumho station is 43.6m which consists of the island-type platform ($8^{th}$ floor in underground) and a two-story lobby (first & second floor in underground). An emergency staircase connects between the platform and the lobby. Hot-wire anemometer, capture hood, wind vane & velocity meter and data acquisition systems are employed to perform the automatic measurement in this experiment. For ordinary case, air supply and exhaust capacity in the lobby were reduced by 34% and 46% compared to the original capacity, respectively. Air supply and exhaust capacity in the platform were reduced by 66% and 38%, respectively. For emergency case, air supply in the lobby was reduced by 42% and air exhaust in the platform was reduced by 28% compared to the original capacity. Therefore, air pollution in the station is expected to be worse in the ordinary environment and smoke control capability in the platform will be weakened in case of fire emergency.

Development of Tunnel-Environment Monitoring System and Its Installation II -Measurement in Gumjung Tunnel- (터널 환경 측정 시스템 개발 및 측정 II -금정터널 측정결과 분석-)

  • Park, Won-Hee;Cho, Youngmin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.4
    • /
    • pp.758-765
    • /
    • 2016
  • This paper is a follow-up paper to the publication, "Development of Tunnel-Environment Monitoring System and Its Installation I - Monitoring System and Measurement in Subway Tunnel" [1]. An environment monitoring system was installed in the 20.3-km-long Gumjung tunnel, which has the general structure of a high-speed double-track railway tunnel. Data were collected for approximately one year. Monthly and daily data were obtained and analyzed for the temperature and relative humidity in summer and winter months. This paper discusses the environmental characteristics at different positions in the tunnel. The results are expected to be widely used in studies on tunnel ventilation and the improvement of air quality and thermal environments.

Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013 (설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.12
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.

A Study on the Structural Reform of Urban Transit Vehicle Considering Elevation of Fire Safety (화재안전성을 위한 도시철도 차량의 구조개선)

  • Lee, Keun-Oh;Kim, Kyu-Joong
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.22-27
    • /
    • 2006
  • Even though the interior of urban transit vehicle has been changed as a preventing measure against fire to make it inflammable, there remains a possibility of fire breaking out in case of gasoline etc being brought in the subway. However, there is also the possibility that in case if fire toxic gas is generated and hot air spreads in carriage it will prove very dangerous for people sitting inside. This is a comparative study where we compare simulation results with model examining the time and direction the fire spreads when it breaks out. Also there is vertical distribution of temperature in carriage where the fire spreads out. This study is about demonstrating how to establish smokeless system in urban vehicle, about its necessity, and about vehicle system restructuring. This study also makes an effort to find more advanced method for efficient fire safety in trains. In existing vehicles, in case of fire, the smoke can't go out when doors are closed and hence it spreads in whole train. Even though the method of using ventilation or exhaust established inside the carriage to throw smoke out is much better than the way of opening end doors in each carriage, this study is trying to do research on second way. Through simulation we see that in second case, even though not as good as the first one, smoke can exit through gates. Even though the first method is better, the second can also be uses to let fire out. We can know that in the first case as the smoke can exit out faster, it provides more safety for people. So this system provides better fire safety condition.