Analysis of air pollution in subway area of Busan Metropolitan City

부산광역시 지하철역 지하공간의 대기오염 특성

  • Lee, Hwa-Woon (Department of Atmospheric Sciences, Pusan National University) ;
  • Jang, Nan-Sim (Department of Atmospheric Sciences, Pusan National University) ;
  • Kwak, Jin (Department of Environmental System, Pusan National University) ;
  • Lee, Hee-Ryung (Department of Environmental System, Pusan National University) ;
  • Kim, Hee-Man (Department of Environmental System, Pusan National University)
  • 이화운 (부산대학교 대기과학과) ;
  • 장난심 (부산대학교 대기과학과) ;
  • 곽진 (부산대학교 환경시스템학과) ;
  • 이희령 (부산대학교 환경시스템학과) ;
  • 김희만 (부산대학교 환경시스템학과)
  • Published : 2002.03.01

Abstract

The purpose of this study is designed to estimate the air quality of subway stations that have the underground platforms in Pusan Metropolitan City, from September to November 2000, over seven times. The subjects include Yonsan-dong station, Somyon station, Pusan station, Nampo-dong station, and Tushil station. The samplings were conducted at three points of each station, i.e. gate, ticket gates, and platforms. The major materials for analysis were CO, NO, NO$_2$, and $O_3$. The experiment was conducted at 7:00 pm with KIMOTO HS-seven Handy sampler and Tedlar Bag of SKC INC(U.S.A). In order to more fully understand station environments, we also measured temperature at each point. The results showed that $O_3$ average concentration at Yonsan-dong station was higher than others with 38~51 ppb. The average concentration of NO was high at ticket gate and platform at Somyon station(119 ppb, 122 ppb), Nampo-dong station(102 ppb, 100 ppb). These results show that the air pollution of stations with underground shopping malls was higher than others. At Somyon station having a junction station, NO and NO$_2$ concentration level of platform-2(noncrowded) was higher than platform-1(crowded). This is most likely due to the accumulation of air pollutants and inadequate ventilation systems.

Keywords

References

  1. National Academy of Science, 1980, Committee of Toxicology, Formaldehyde - An assessment of its health effects, Report to the Consumer Product Safety Commission, Washington, D. C.
  2. Liao, S. S. T. and Bacon - shone J., 1991, Factors influencing indoor air quality in Hong Kong, Measurements in Offices and Shops., Environ. Tech., 12, 737-745 https://doi.org/10.1080/09593339109385065
  3. 新山惠三, 1977, 都市生活空間としての地下環境の基礎的考察, 公害と對策, 13, 946-949
  4. 吉川友章, 1977, 地下街道路の空氣汚染現況, 公害と對策, 13(9), 18-29
  5. 本田どえり, 1977, 浮遊迎細菌による地下環境空氣汚染の現況,公害と對策, 13(9), 6-16
  6. B., A. Tichenor and Sparks, L. A., 1990, Evaluating sources of indoor air pollution, Air Waste Manage. Assoc., 40(4), 487-492 https://doi.org/10.1080/10473289.1990.10466703
  7. Nero, A. V., 1988, Controlling indoor pollution, Sci. Ameri., 258(5), 43-48
  8. Phillips, J. L., R. Field, M. Goldstone, G. L. Reynolds, J. N. Lester and R. Perry, 1993, Relationships between indoor and outdoor air quality in four naturally ventilated office in the United Kingdom, Atoms. Environ., 27(A), 1743-1753 https://doi.org/10.1016/0960-1686(93)90238-T
  9. 송희봉, 민경섭, 한개희, 검종우, 백성옥, 1996, 대구지역 공중이용시설 실내.외 공기중 기준성 오염물질의 농도, 한국대기보전학회지, 12(4), 429-439
  10. 환경부, 환경부 홈페이지, 2000
  11. 日本環境廳, 2000, 日本 環境基準法, 16條 1項
  12. 한용수, 1990, 부산지역 중앙로변의 공기오염도에 대한 조사연구, 인제대학교 대학원 석사 논문, 9-10
  13. 이채언, 문덕환, 조병만, 김준연, 배기철, 1989, 부산지역 지하상가의 대기오염도에 관한 조사연구, 한국대기보전학회지, 5(1), 22-32
  14. Zimmerman, S. S. and B. Truxal, 1981, Carbon monoxide poisoning, pediatrics, 68, 215-224
  15. 朴松學, 1986, 室內空氣汚染の關よる硏究, 大氣汚染, 21(3), 236-252
  16. 吉川友章, 1977, 地下街道路の空氣汚染現況, 公害と對策, 13(9), 18-29