• 제목/요약/키워드: Subway ground vibration

검색결과 36건 처리시간 0.023초

Vertical Z-vibration prediction model of ground building induced by subway operation

  • Zhou, Binghua;Xue, Yiguo;Zhang, Jun;Zhang, Dunfu;Huang, Jian;Qiu, Daohong;Yang, Lin;Zhang, Kai;Cui, Jiuhua
    • Geomechanics and Engineering
    • /
    • 제30권3호
    • /
    • pp.273-280
    • /
    • 2022
  • A certain amount of random vibration excitation to subway track is caused by subway operation. This excitation is transmitted through track foundation, tunnel, soil medium, and ground building to the ground and ground structure, causing vibration. The vibration affects ground building. In this study, the results of ANSYS numerical simulation was used to establish back-propagation (BP) neural network model. Moreover, a back-propagation neural network model consisting of five input neurons, one hidden layer, 11 hidden-layer neurons, and three output neurons was used to analyze and calculate the vertical Z-vibration level of New Capital's ground buildings of Qingdao Metro phase I Project (Line M3). The Z-vibration level under different working conditions was calculated from monolithic roadbed, steel-spring floating slab roadbed, and rubber-pad floating slab roadbed under the working condition of center point of 0-100 m. The steel-spring floating slab roadbed was used in the New Capital area to monitor the subway operation vibration in this area. Comparing the monitoring and prediction results, it was found that the prediction results have a good linear relationship with lower error. The research results have good reference and guiding significance for predicting vibration caused by subway operation.

도시철도 지반진동 예측식 개선에 관한 연구 (Study on the Improvement of Empirical Formula for Prediction of Ground Vibration Induced by Urban Rapid Transit)

  • 신한철;조선규;양신추
    • 한국철도학회논문집
    • /
    • 제12권3호
    • /
    • pp.357-363
    • /
    • 2009
  • 본 논문에서는 도시철도 운행으로 발생하는 지반진동의 예측을 위하여 서울지하철 현장 계측을 실시하였다. 현장 계측 결과와 뉴욕지하철의 예측식과 동경지하철의 예측식으로 산정된 값과 비교한 결과, 국내 지반의 지반진동레벨은 뉴욕지하철의 예측식보다 크게 산정되었으며, 동경지하철의 예측식보다는 다소 작게 산정되었다. 또한, 계측현장 지반의 전파경로에 따라 토사지반과 암반지반으로 구분하여 국내 지반특성에 적합한 지반진동 예측식을 제안하였다.

지하철에 의한 지반 진동 예측에 관한 연구 (Study for the prediction of ground-borne vibration induced by subway)

  • 이재원;김득성;장서일
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 추계학술대회논문집 II
    • /
    • pp.1287-1292
    • /
    • 2001
  • Subway train-induced ground-borne vibration is studied. Previously used vibration level prediction equations are reviewed. Measured vibration levels are compared with the predicted results and numerically computed results. The results show that vibration level does not decrease proportionally with the distance.

  • PDF

지하철 운행에 의한 인접건물의 진동영향 평가 연구 (Reduction and Evaluation of Subway Induced Vibration Effects on Surrounding Buildings)

  • 박지훈;민경원;이루지;최석주;염성곤
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.738-742
    • /
    • 2005
  • Ground vibration at Gil-dong in Seoul induced by the 5th ling of Seoul Subway is predicted using various prediction methods and compared with measured vibration. Also, several issues on the improvement of prediction methods are discussed. Furthermore, as an alternative vibration source, measured vibration acceleration level(VAL) on the tunnel wall of the Bundang line of Seoul Subway is applied to the prediction of the VAL at the location mentioned previously. Then requirements accompanied to the suggestion of the new vibration source appropriate to the condition of Seoul Subway.

  • PDF

지하철 차량운행에 의한 진동영향 평가: State of the Art (Prediction and Control of the Propogation of Underground Train Systems-induced Ground Vibration: State of the Art)

  • 이인모;최상순;밝보리나라
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 1993년도 학술발표집 지반진동 영향평가
    • /
    • pp.73-82
    • /
    • 1993
  • Ground-borne vibration is one of the main causes of environmental impact from subway systems. The vibration resulting from track-train interaction is transuutted through the tunnel structure and the surrounding ground to adjacent buildings. This paper provides a summary of proposed noise and vibration criteria, a review of the ground vibration propagation mechanism and the theoretical isolation effectivenesss of each of the following underground transit systems : track, tunnel and vehicle itself.

  • PDF

지하철 주변 지반진동의 전파경로가 진동레벨 감쇠에 미치는 영향 (The Effects of the Wave Propagation Path of Ground Vibration Induced by the Subway Train on the Reduction of Vibration Level)

  • 신한철;조선규;양신추;이종민
    • 한국철도학회논문집
    • /
    • 제12권5호
    • /
    • pp.631-640
    • /
    • 2009
  • 본 논문에서는 수치해석적인 기법을 이용하여 지하철 주변 지반의 진동레벨 감쇠에 대한 연구를 수행하였다. 해석 결과 터널이 토사지반에 있을 경우 지반진동에 가장 큰 영향을 미치는 요소는 지반의 물성치로 나타났고, 암반에 있을 경우 가장 큰 영향을 미치는 것은 암반의 물성치로 나타났다. 또한, 진동원과의 연직면에서 떨어져 있는 각도를 기준으로 영향범위를 산정한 결과, 대부분의 해석 결과에서 연직면에서 $30^{\circ}$ 이내에 있을 경우 진동레벨의 감쇠 현상은 크지 않은 것으로 판단되었고, $40^{\circ}$ 이상이 되면 진동레벨은 급격히 감소하는 경향이 있는 것으로 나타났다.

실내 진동대 실험을 통한 해안매립지반의 동적 특성 평가 (Dynamic Characteristic of Coastal Reclaimed Land through Shaking Table Test)

  • 신은철;강현회;박정준
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2009년도 춘계 학술발표회
    • /
    • pp.640-648
    • /
    • 2009
  • Recently the truction of coastal reclaimation work has been extensively implemented in Korea. The Sondo New City is being established on the reclaimed land from the sea, construction companies of metro construction are planing to pull-out the sheet pile for saving the construction cost. In the case of soft marine clay, it is very difficult to pull-out the sheet pile by using the hydraulic hammer difficult. Therefore, the man of the field must be aware of vibration effect to the ground and the structure. For understanding the vibration effect to the ground during subway construction, the model was formulated with 1/25 braced-cut for subway construction. Scott and Iai(1989) proposed the law of the similarity for other experimental conditions. The laboratory model test was conducted under the vibration condition of sheet pile pulling out. The settlement on the ground surface was measured during the shaking table test. The pore water pressure was also monitored in the upper, middle, and lower layers of soil. The field settlement level and the pore water pressure can be predicted by using the results of the laboratory shaking table test.

  • PDF

서울 지하철 건설의 발파기술 발전 (ON THE DEVELOPMENT OF EXPLOSION TECHNOLOGY IN SEOUL METRO SUBWAY CONSTRUSTION)

  • 許眞
    • 화약ㆍ발파
    • /
    • 제18권1호
    • /
    • pp.59-70
    • /
    • 2000
  • The blasting work to construct a subway in seoul, korea have often cased increased neighbor's complaints because of ground vibration. In order to prevent the demage to the stucture it was necessary to predict the level of blasting induced vibration and to determine the maximum charge weigh per delay with an allowable vibration level. The effect of blasting pattem, rock strength and different explosive on the blast-induced ground vibration was studied to determine the maximum charage weight per delay within a given vibration level. The blasting vibration equation from over 100 test data was obtained, V= K(D/W(equation omitted), where the values for n and K are estimated to be 1.7 to 1.5 and 48 to 138 respectively.

  • PDF

Autonomous evaluation of ambient vibration of underground spaces induced by adjacent subway trains using high-sensitivity wireless smart sensors

  • Sun, Ke;Zhang, Wei;Ding, Huaping;Kim, Robin E.;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • 제19권1호
    • /
    • pp.1-10
    • /
    • 2017
  • The operation of subway trains induces secondary structure-borne vibrations in the nearby underground spaces. The vibration, along with the associated noise, can cause annoyance and adverse physical, physiological, and psychological effects on humans in dense urban environments. Traditional tethered instruments restrict the rapid measurement and assessment on such vibration effect. This paper presents a novel approach for Wireless Smart Sensor (WSS)-based autonomous evaluation system for the subway train-induced vibrations. The system was implemented on a MEMSIC's Imote2 platform, using a SHM-H high-sensitivity accelerometer board stacked on top. A new embedded application VibrationLevelCalculation, which determines the International Organization for Standardization defined weighted acceleration level, was added into the Illinois Structural Health Monitoring Project Service Toolsuite. The system was verified in a large underground space, where a nearby subway station is a good source of ground excitation caused by the running subway trains. Using an on-board processor, each sensor calculated the distribution of vibration levels within the testing zone, and sent the distribution of vibration level by radio to display it on the central server. Also, the raw time-histories and frequency spectrum were retrieved from the WSS leaf nodes. Subsequently, spectral vibration levels in the one-third octave band, characterizing the vibrating influence of different frequency components on human bodies, was also calculated from each sensor node. Experimental validation demonstrates that the proposed system is efficient for autonomously evaluating the subway train-induced ambient vibration of underground spaces, and the system holds the potential of greatly reducing the laboring of dynamic field testing.

이중 복합터널 상부구조물의 진동에 대한 안정성 평가 (Estizmation of Structure Stability on the Ground to Vibration from Dual Composite Tunnels)

  • 신승목;장연수;이우진;권순정
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1244-1250
    • /
    • 2008
  • The site of interest is a residence redevelopment area which has excavation construction with cut-off walls. The site is located over Dong-Mang-Bong tunnel and Seoul No. 6 subway tunnel. This study analyzed numerically the influence of vibrations from No. 6 subway tunnel to the basement of the redeveloped apartment away from the distance about 11m. Kyoung-bu highspeed railway's time history model with linearly reduced maximum acceleration is applied to take into the subway maximum speed of 75km/h. The maximum velocity of vibration for the cross section of the interest was estimated as 0.28cm/sec which satisfied the allowable standard of 0.5cm/sec for apartment and residence of Seoul.

  • PDF