• Title/Summary/Keyword: Subspan Oscillation

Search Result 11, Processing Time 0.028 seconds

A study on Subspan Oscillation Analysis of 6 Bundle Conductor Transmission lines (6도체방식 송전선로의 서브스판진동 해석에 관한 연구)

  • 이형권
    • Journal of KSNVE
    • /
    • v.7 no.5
    • /
    • pp.729-736
    • /
    • 1997
  • The subspan oscillation is the most important in bundled transmission lines, which can cause conductor damage and transmission line hardware failures. So it is necessary to analyze the subspan oscillation in details for transmission lines. This paper suggests the basic concept and theoretical analysis method of subspan oscillation for 6 bundle conductor transmission line, which considers wind speed, subspan length and conductor tension. Especially this paper uses a spacer damper model with clamp-arm flexibility and damping characteristics. Theoretical analysis results are proposed.

  • PDF

A Stability Estimation Method of Subspan Oscillation on Overhead Transmission Lines (가공송전선로의 서브스판 진동에 대한 안정성 평가기법)

  • Sohn, Hong-Kwan;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.522-524
    • /
    • 2003
  • This paper presents a stability estimation method for subspan oscillation on overhead transmission line. It has been used method by conductor's fatigue limit or subspan oscillation amplitude. But it is not proper to estimation of subspan oscillation. We suggest to instability index for estimation method of subspan oscillation. And we tried to 4 bundled conductor system. This result will use to establish of the subspan location rules.

  • PDF

A Frequency Analysis of Subspan Oscillation on Overhead Transmission Lines (가공송전선로의 서브스판 진동에 대한 주파수 특성 분석)

  • Sohn, Hong-Kwan;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.519-521
    • /
    • 2003
  • This paper presents a frequency analysis of subspan oscillation on overhead transmission line. The Oscillation frequency is a natural characteristic of a subspan and can be calculated. But it is not same to calculated frequency, because it has been composed several frequencies of adjacent subspan. We were analyzed to the frequency of subspan oscillation by FFT methods. This result will use to establish of the subspan location rules.

  • PDF

A Study on Measures Against Subspan Oscillation using Twin Spacers in 4 Bundle Overhead Lines (4도체 가공선로에서 복도체 스페이서를 이용한 진동저감 대책 연구)

  • Lee, Hyung-Kwon;Han, Hyeong-Ju
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.3
    • /
    • pp.323-327
    • /
    • 2009
  • The oscillation is very dangerous in bundled transmission lines, besides 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 4 bundle overhead lines, and we got a good effect for controling subspan oscillations by installing twin spacers.

A study on measures against subspan oscillation by twin spacers in 345kV overhead transmission lines(II) (345kV 가공선로에서 진동발생 다발 소경간에 대한 진동저감 대책(II))

  • Lee, H.K.;Han, H.J.;Park, C.K.;Choi, W.K.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04b
    • /
    • pp.200-202
    • /
    • 2008
  • The oscillation is very dangerous in bundled transmission lines, especially 345kV 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying twin spacers to the subspans. We have carried out some tests to analyze the oscillation phenomena after installing twin spacers on 34sky real lines, and we got a good effect for controling subspan oscillations.

  • PDF

A study on measures against subspan oscillation by spacers for 2 bundled conductors in 345kV overhead T/L (345kV 가공선로 진동다발 소경간에 대한 진동저감 대책(I))

  • Kim, W.K.;Lee, D.H.;Shin, J.S.;Lee, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.679-680
    • /
    • 2007
  • The oscillation is very dangerous in bundled transmission lines, especially 345kV 4 bundle transmission lines are very weak for subspan oscillations. In some cases, subspan oscillations are continuously occurred in the same subspan. In order to develop the control method of the above subspan oscillation, this paper suggests a method of applying spacers for 2 bundled conductors to the subspans. In the future we will try to observe and analyze the oscillation after installing the spacers for 2 bundled conductors, and suggest the effective method for controling subspan oscillations.

  • PDF

Field Observation and Analysis of Wind-Induced Vibrations in Four-Bundled Conductor Transmission Lines

  • Sohn, Hong-Kwan;Lee, Hyung-Kwon;Chu, Jang-Hee;Lee, Dong-Il;Lee, Eun-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • v.3A no.2
    • /
    • pp.109-114
    • /
    • 2003
  • This paper presents observations made on four-bundled conductor transmission lines concerning the behavior of conductors under the effect of natural winds. To know the wind-induced vibration status and how to control it, wind-induced vibrations have been recorded and analyzed from the real transmission lines. From the field observation and analysis results, subspan oscillation was found to be the main type of vibration. In addition, the data also revealed some common characteristics of the observation sites with high maintenance rates. The results will be used in controlling the subspan oscillations and protecting the conductors.

Experimental Study on the Relation Between the Longitudinal Articulation Part of a Spacer Damper and Subspan Oscillations (스페이서댐퍼 클램프의 선로방향 관절부와 서브스판진동과의 관계 실험적 고찰)

  • Lee, Hyung-Kwon
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.58 no.4
    • /
    • pp.447-450
    • /
    • 2009
  • In order to protect conductors from oscillations or vibrations due to winds, spacer dampers are installed on overhead transmission lines. Generally the spacer damper clamp can move slightly according to oscillation directions, namely in longitudinal, vertical & horizontal directions. This is for reducing fatigue phenomena of the conductor. But the high longitudinal- displacement of the clamp raises a doubt for its necessity. Then this paper carried out oscillation tests by using 4 bundle test lines, to know the relation between longitudinal displacement and oscillation. and suggests design necessity of the longitudinal articulation part for spacer damper clamps.

Experimental study for the spacer damper clamp displacement due to subspan oscillations (가공선로 서브스판진동이 스페이서댐퍼 클램프 변위에 미치는 영향 실험적 고찰)

  • Lee, H.K.;Han, H.J.;Bang, H.K.
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.2094-2095
    • /
    • 2008
  • In order to protect conductors from oscillations or vibrations due to winds, spacer dampers or spacers are installed on bundled conductors in overhead transmission lines. Generally the spacer damper clamp can move slightly according to oscillation directions, namely conductor direction, vertical & horizontal direction This is for reducing fatigue phenomena of the clamps. Sometimes movement of the clamp to conductor direction raises a doubt for its necessity. Then this paper carried out oscillation tests to know clamp displacement due to the subspan oscillation.

  • PDF

A Study on the Installation method of the Spacer Damper for Bundled T/L (송전선로 스페이서댐퍼 적정 설치방안 연구)

  • Lee, H.K.;Sohn, H.K.;Lee, D.I.;Wi, H.B.;Park, W.D.
    • Proceedings of the KIEE Conference
    • /
    • 2003.07a
    • /
    • pp.436-438
    • /
    • 2003
  • Wind-induced oscillations are known to cause damage to the conductors and related hardware through fatigue, clashing of the bundled conductors and bolt loosening. Wake-induced oscillations have been known since the advent of bundled conductors, they are caused by aerodynamically unstable forces acting on the leeward conductors in the wake of the windward conductors, They take the form of horizontal galloping, snaking or rolling, in which case all subconductors move together in unison. They can also take the form of the subspan oscillation, which appear as elliptical motions of the subconductors moving out of phase, mainly in the horizontal plane within a subspan. In order to decrease amplitudes of the oscillation, this paper examines the application status of the spacer dampers and suggests proper installation methods.

  • PDF