• 제목/요약/키워드: Sub-harmonic

검색결과 217건 처리시간 0.03초

HVDC 적용을 위한 MMC 기반 Back-to-Back 컨버터의 스위칭레벨 동작분석 (Switching-Level Operation Analysis of MMC-based Back-to-Back Converter for HVDC Application)

  • 홍정원;정종규;유승환;최종윤;한병문
    • 전기학회논문지
    • /
    • 제62권9호
    • /
    • pp.1240-1248
    • /
    • 2013
  • This paper describes a switching-level operation analysis of BTB(Back-To-Back) converter for HVDC(high voltage DC) application based on MMC(modular multi-level converter). A switching-level operation analysis for BTB converter is very important to understand the converter operation in detail and check the voltage and current transients in each components. However, the development of switching-level simulation model for the actual size BTB Converter is very difficult because the MMC normally has more than 150 sub-modules for each arm. So, a switching level simulation model for the 11-level MMC-based BTB converter was developed with PSCAD/EMTDC software, which has 12 sub-modules for the positive arm and another 12 sub-modules for the negative arm. The DC-voltage balance algorithm, the circulating-current reduction algorithm, the harmonic reduction algorithm, and the redundancy operation algorithm were included in this simulation model. The developed simulation model can be utilized to analyze the MMC-based BTB converter for HVDC application in switching level and to develop the protection scheme for the MMC-based BTB converter for HVDC application.

120 GHz 국부발진기의 설계 및 제작 (A Design and Fabrication of 120 GHz Local Oscillator)

  • 이원희;정태진
    • 한국인터넷방송통신학회논문지
    • /
    • 제10권6호
    • /
    • pp.71-76
    • /
    • 2010
  • 본 논문은 캐리어 주파수가 240 GHz인 THz 대역 송수신기에 있어서, 서브하모닉 믹서의 LO 주파수로 사용되는 120 GHz 국부발진기의 설계 및 제작에 관한 것이다. 120 GHz 국부발진기는 40 GHz PLL(Phase Locked Loop), 40 GHz 대역통과필터(Band Pass Filter), 3 체배기(frequency tripler), 120 GHz 대역통과필터로 구성되어 있으며, 3 체배기는 상용품을 이용하였다. 40 GHz PLL의 위상잡음은 100 kHz offset 주파수에서 -105 dBc/Hz의 성능을 보였고, 120 GHz의 대역통과필터의 중심주파수 119 GHz, 대역폭 5 GHz 일 때 삽입손실은 1.3 dB로 측정되었다. 제작된 120 GHz 국부발진기의 최종 출력은 6.6 dBm이었다.

다중 대역 레이더 신호 수신을 위한 이중 모드 주파수 혼합기 (A Dual-Mode Mixer for Multi-Band Radar Signal Reception)

  • 고민호;김형주;나선필;김재현
    • 한국전자파학회논문지
    • /
    • 제24권11호
    • /
    • pp.1047-1054
    • /
    • 2013
  • 본 논문은 다중 대역 레이더 수신기의 소형화를 위한 이중 모드 주파수 혼합기를 구현하였다. 제안한 혼합기는 역병렬 다이오드(anti-parallel diode)를 이용하였고, 제어 전압 유무에 따라 기본파 혼합기 또는 부고조파 혼합기로 동작한다. 제어 전압을 인가하여 기본파 혼합기로 동작하는 경우, X-대역에서 -10 dB 변환 손실, 2.0 dBm P1dB 특성을 나타내었고, 제어 전압을 인가하지 않은 부고조파 혼합기로 동작하는 경우 K-대역에서 -10 dB 변환 손실, 2.0 dBm P1dB 특성을 나타내었다.

Dynamical Rolling Analysis of a Vessel in Regular Beam Seas

  • Lee, Sang-Do;You, Sam-Sang
    • 해양환경안전학회지
    • /
    • 제24권3호
    • /
    • pp.325-331
    • /
    • 2018
  • This paper deals with the dynamical analysis of a vessel that leads to capsize in regular beam seas. The complete investigation of nonlinear behaviors includes sub-harmonic motion, bifurcation, and chaos under variations of control parameters. The vessel rolling motions can exhibit various undesirable nonlinear phenomena. We have employed a linear-plus-cubic type damping term (LPCD) in a nonlinear rolling equation. Using the fourth order Runge-Kutta algorithm with the phase portraits, various dynamical behaviors (limit cycles, bifurcations, and chaos) are presented in beam seas. On increasing the value of control parameter ${\Omega}$, chaotic behavior interspersed with intermittent periodic windows are clearly observed in the numerical simulations. The chaotic region is widely spread according to system parameter ${\Omega}$ in the range of 0.1 to 0.9. When the value of the control parameter is increased beyond the chaotic region, periodic solutions are dominant in the range of frequency ratio ${\Omega}=1.01{\sim}1.6$. In addition, one more important feature is that different types of stable harmonic motions such as periodicity of 2T, 3T, 4T and 5T exist in the range of ${\Omega}=0.34{\sim}0.83$.

축소모형을 이용한 MMC의 Redundancy Module 동작분석 (Redundancy Module Operation Analysis of MMC using Scaled Hardware Model)

  • 유승환;신은석;최종윤;한병문
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1046-1054
    • /
    • 2014
  • In this paper, a hardware prototype for the 10kVA 11-level MMC was built and various experimental works were conducted to verify the operation algorithms of MMC. The hardware prototype was designed using computer simulation with PSCAD/EMTDC software. After manufactured in the lab, the hardware prototype was tested to verify the modulation algorithms to form the output voltage, the balancing algorithm to equalize the sub-module capacitor voltage, and the redundancy operation algorithm to improve the system reliability. The developed hardware prototype can be utilized for analyzing the basic operation and performance improvement of MMC according to the modulation and redundancy operation scheme. It also can be utilize to analyze the basic operational characteristics of HVDC system based on MMC.

Discontinuous finite-element quadrature sets based on icosahedron for the discrete ordinates method

  • Dai, Ni;Zhang, Bin;Chen, Yixue
    • Nuclear Engineering and Technology
    • /
    • 제52권6호
    • /
    • pp.1137-1147
    • /
    • 2020
  • The discrete ordinates method (SN) is one of the major shielding calculation method, which is suitable for solving deep-penetration transport problems. Our objective is to explore the available quadrature sets and to improve the accuracy in shielding problems involving strong anisotropy. The linear discontinuous finite-element (LDFE) quadrature sets based on the icosahedron (in short, ICLDFE quadrature sets) are developed by defining projected points on the surfaces of the icosahedron. Weights are then introduced in the integration of the discontinuous finite-element basis functions in the relevant angular regions. The multivariate secant method is used to optimize the discrete directions and their corresponding weights. The numerical integration of polynomials in the direction cosines and the Kobayashi benchmark are used to analyze and verify the properties of these new quadrature sets. Results show that the ICLDFE quadrature sets can exactly integrate the zero-order and first-order of the spherical harmonic functions over one-twentieth of the spherical surface. As for the Kobayashi benchmark problem, the maximum relative error between the fifth-order ICLDFE quadrature sets and references is only -0.55%. The ICLDFE quadrature sets provide better integration precision of the spherical harmonic functions in local discrete angle domains and higher accuracy for simple shielding problems.

Experimental assessment of the piezoelectric transverse d15 shear sensing mechanism

  • Berik, Pelin;Benjeddou, Ayech;Krommer, Michael
    • Smart Structures and Systems
    • /
    • 제13권4호
    • /
    • pp.567-585
    • /
    • 2014
  • The piezoelectric transverse $d_{15}$ shear sensing mechanism is firstly assessed experimentally for a cantilever smart sandwich plate made of a piezoceramic axially poled patched core and glass fiber reinforced polymer composite faces. Different electrical connections are tested for the assessment of the sensor performance under a varying amplitude harmonic (at 24 Hz) force. Also, the dynamic response of the smart sandwich composite structure is monitored using different acquisition devices. The obtained experimentally sensed voltages are compared to those resulting from the benchmark three-dimensional piezoelectric coupled finite element simulations using a commercial code where realistic features, like equipotential conditions on the patches' electrodes and mechanical updating of the clamp, are considered. Numerically, it is found that the stiffness of the clamp, which is much softer than the ideal one, has an enormous influence on the sensed voltage of its adjacent patch; therefore, sensing with the patch on the free side would be more advantageous for a cantilever configuration. Apart from confirming the latter result, the plate benchmark experimental assessment showed that the parallel connection of its two oppositely poled patches has a moderate performance but better than the clamp side patch acting as an individual sensor.

헬리컬 기본교란과 축대칭 분수조화교란을 이용한 원형제트에서의 보텍스 병합 및 제트확산 (Vortex Pairing and Jet-Spreading in an Axisymmetric Jet under Helical Fundamental and Axisymmetric Subharmonic Forcing)

  • 조성권;유정열;최해천
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1610-1624
    • /
    • 1998
  • An axisymmetric jet is forced with two helical fundamental waves of identical frequency spinning in opposite directions and an additional axisymmetric sub harmonic wave. The subharmonic component rapidly grows downstream from subharmonic resonance with the fundamental, significantly depending on the initial phase difference. The variations of the subharmonic amplitude with the initial phase difference show cusp-like shapes. The amplification of the sub harmonic results in 'vortex pairing of helical modes'. Furthermore, azimuthal variation of the amplification induces an asymmetric jet cross-section. When the initial subharmonics is imposed with an initial phase difference close to a critical value, the jet-cross section evolves into a three-lobed shape. One lobe is generated by the enhanced vortex pairing and the other two lobes are generated by the delayed vortex pairing. Thus, it is confirmed that the initial phase difference between the fundamental and the subharmonic plays an important role in controlling the jet cross-section.

스펙트럼 해석에 의한 자탈형 콤바인의 진동 특성 고찰 (A Study on the Vibration Characteristics of a Head-Feeding Combine by Spectral Analysis)

  • 최중섭
    • Journal of Biosystems Engineering
    • /
    • 제26권1호
    • /
    • pp.11-20
    • /
    • 2001
  • Experiments under the stationary and harvesting condition, were performed in order to investigate the vibration characteristics of a head-feeding combine. 6 degrees of freedom components of acceleration at the location of the center of the gravity, and 3 degrees of freedom components of acceleration at the location of the operator seat were measured independently. The vibration characteristics of the combine were estimated with the power spectral density of the time series data of accelerations. From this research, the following results were obtained. 1. Vibration of a head-feeding combine under the stationary condition(engine, thresher and cutter are driven without harvesting) is mainly influenced by the engine. Further, 1/3, 1/2 (sub-harmonic) frequency components of the engine are observed besides engine driving frequency component(45Hz). 2. Vibration of a head-feeding combine under the harvesting condition is influenced by the engine, threshing unit and driving unit. Namely, some kinds of vibration frequency components in harvesting are observed compared with stationary condition. Further, sub-harmonic frequency components of the engine are observed besides engine driving frequency component as same as stationary condition. From these results, it may be concluded that vibration of a head-feeding combine is characteristics of semi-periodic and nonlinear vibration.

  • PDF

PLIF 및 자발광 계측을 이용한 이중선회 가스터빈 연소기에서 연소불안정 모드 연구 (A Study of Combustion Instability Mode in Dual Swirl Gas Turbine Combustor by PLIF and Chemiluminescence Measurement)

  • 최인찬;이기만
    • 한국연소학회지
    • /
    • 제19권1호
    • /
    • pp.29-38
    • /
    • 2014
  • This paper described an experimental investigations of combustion instability mode in a lean premixed dual swirl combustor for micro-gasturbine system. When such the instability occurs, a strong coupling between pressure oscillations and unsteady heat release excites a self-sustained acoustic wave which results in a loud, annoyed sound and may also lead a structural damage to the combustion chamber. The detailed period of flame behavior and heat release in combustion instability mode have been examined with high speed OH and CH-PLIF system and $CH^*$ chemiluminescence measurement, flame tomography with operated at 10 kHz and 6 kHz each. Experiment results suggest that unstable flame behavior has a specific frequency with 200 Hz and this frequency is accords with about 1/2 sub-harmonic of combustor resonance frequency, not fundamental frequency. This is very interesting phenomenon that have not reported yet from other previous works. Therefore, when a thermo-acoustic instability with Rayleigh criterion occurs, the fact that the period of heat release and flame behavior are different each other was proposed for the first time through this work.