• Title/Summary/Keyword: Structural static tests

Search Result 362, Processing Time 0.026 seconds

A Case Study on the Dynamic Loading Tests of Large Diameter - Long Drilled Shafts into Weathered Rock (풍화암에 근입된 장대 현장타설말뚝의 동재하시험 사례연구)

  • Seok, Jeong-Woo;Cho, Chun-Whan;Ji, Wan-Goo;Park, Min-Cheul;Yoon, Jeoung-Seob
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.486-493
    • /
    • 2006
  • This paper deals with the procedure and the results on the dynamic loading tests of two large diameter - long drilled shafts (diameter=2.0m, length=75m) which were embedded into weathered rocks through thick soft marine clays and sandy gravels. Prior to the real dynamic loading test, the numerical simulation for the test procedure was performed to check the structural stability of the main pile body using equivalent static elastic analysis and the application of the hammer system using WEAP (Wave Equation Analysis of Pile Driving). Through these preliminary analyses the dynamic loading tests on large diameter - long drilled shafts have been successfully achieved.

  • PDF

Quasi-steady three-degrees-of-freedom aerodynamic model of inclined/yawed prisms: Formulation and instability for galloping and static divergence

  • Cristoforo Demartino;Zhen Sun;Giulia Matteoni;Christos T. Georgakis
    • Wind and Structures
    • /
    • v.37 no.1
    • /
    • pp.57-78
    • /
    • 2023
  • In this study, a generalized three-degree-of-freedom (3-DoF) analytical model is formulated to predict linear aerodynamic instabilities of a prism under quasi-steady (QS) conditions. The prism is assumed to possess a generic cross-section exposed to turbulent wind flow. The 3-DoFs encompass two orthogonal horizontal directions and rotation about the prism body axis. Inertial coupling is considered to account for the non-coincidence of the mass center and the rotation center. The aerodynamic force coefficients-drag, lift, and moment-depend on the Reynolds number based on relative flow velocity, angle of attack, and the angle between the wind and the cable. Aerodynamic forces are linearized with respect to the static equilibrium configuration and mean wind velocity. Routh-Hurwitz and Liénard and Chipart criteria are used in the eigenvalue problem, yielding an analytical solution for instabilities in galloping and static divergence types. Additionally, the minimum structural damping and stiffness required to prevent these instabilities are numerically determined. The proposed 3-DoF instability model is subsequently applied to a conductor with ice accretion and a full-scale dry inclined cable. In comparison to existing models, the developed model demonstrates superior prediction accuracy for unstable regions compared with results in wind tunnel tests.

Quasi-Static and Shaking Table Tests of Precast Concrete Structures Utilizing Clamped Mechanical Splice (가압고정 기계적이음을 활용한 프리캐스트 콘크리트 구조물의 준정적 및 진동대 실험)

  • Sung, Han Suk;Ahn, Seong Ryong;Park, Si Young;Kang, Thomas H.-K.
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.27 no.1
    • /
    • pp.37-47
    • /
    • 2023
  • A new clamped mechanical splice system was proposed to develop structural performance and constructability for precast concrete connections. The proposed mechanical splice resists external loading immediately after the engagement. The mechanical splices applicable for both large-scale rebars for plants and small-scale rebars for buildings were developed with the same design concept. Quasi-static lateral cyclic loading tests were conducted with reinforced and precast concrete members to verify the seismic performance. Also, shaking table tests with three types of seismic wave excitation, 1) random wave with white noise, 2) the 2016 Gyeongju earthquake, and 3) the 1999 Chi-Chi earthquake, were conducted to confirm the dynamic performance. All tests were performed with real-scale concrete specimens. Sensors measured the lateral load, acceleration, displacement, crack pattern, and secant system stiffness, and energy dissipation was determined by lateral load-displacement relation. As a result, the precast specimen provided the emulative performance with RC. In the shaking table tests, PC frames' maximum acceleration and displacement response were amplified 1.57 - 2.85 and 2.20 - 2.92 times compared to the ground motions. The precast specimens utilizing clamped mechanical splice showed ductile behavior with energy dissipation capacity against strong motion earthquakes.

Development of hybrid artificial reef and basic structural performance tests (복합형 인공어초의 개발 및 구조 성능 평가)

  • Ko, Hune-Bum;Kim, Hee-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.341-347
    • /
    • 2018
  • The purpose of this study is to develop a new type of hybrid artificial reef that can solve the problems of construction, installation and operation of existing concrete type and steel type artificial reef, and to evaluate basic structural performance through static loading test. For this purpose, we evaluated the strengths and weaknesses of concrete type and steel type artificial reef in literature, and developed a new type of hybrid artificial reef which can effectively overcome the problems of each artificial reefs while maintaining the advantages of two artificial reefs as an alternative respectively. In order to evaluate the merits of the proposed hybrid artificial reef, it was confirmed that the possibility of securing the convenience of the proposed hybrid artificial reef in the field and the possibility of securing the desired advantages were confirmed. Also, the static loading test was performed to evaluate the basic structural performance of the artificial reef. Through the above study, it was confirmed that the developed hybrid artificial reef exhibited proper structural performance while securing easiness of making and assemble.mm) can be predicted to have a low value up to 60% of the strength of cylinders without reinforcement.

Wind induced response of an elevated steel water tank

  • Sepe, Vincenzo;Zingali, Antonino E.
    • Wind and Structures
    • /
    • v.4 no.5
    • /
    • pp.383-398
    • /
    • 2001
  • The paper describes the results of the monitoring of an elevated steel water-tank with unusual shape, 85 m high and 40 m wide. The research was carried out analysing both the static and dynamic behaviour under wind actions. The instruments used (some of which were employed for the first time for this project) are described and the data processing procedures are discussed. Comparison between the experimental results and those obtained through a numerical model gives interesting information both on the structural behaviour and on the characterisation of wind actions.

A study on strain specification and safety degree of connection joints of steel structural member (강구조부재 연결부의 변형특성 및 안전도에 관한 연구)

  • 김경진;김두환
    • Journal of the Korean Professional Engineers Association
    • /
    • v.19 no.4
    • /
    • pp.5-10
    • /
    • 1986
  • On SWS 41 Plates jointed by the F11T M 20 high strength bolts the study on stress behavior and safety degree until rupture in static tensile tests were performed. By these results, in case of no clamping force stress concentration was extremed for strain of about 10% higher ratio. Elastic strain occurred to change of test specimens depth by the load and plastic strain occurred to local minute sleep after elastic strain. compared shear stress with tension stress from the fracture load it was showned lower values than the maximum shear stress theory and stress strain energy theory.

  • PDF

KSTAR Superconducting Magnet Supporting Post Prototype Manufacturing and Structural Load Test (KSTAR 초전도자석 지지각 시작품재작 및 구조시험)

  • 허남일;이영신
    • Progress in Superconductivity and Cryogenics
    • /
    • v.3 no.1
    • /
    • pp.45-49
    • /
    • 2001
  • A magnet supporting post installed between the lower TF coil tooled by 4.5 K supercritical helium and the cryostat base is one of the most important components of the superconducting magnet supporting structure for KSTAR Tokamak. This structure should be flexible to absorb thermal shrink of the magnet and also should be rigid to support the magnet weight and the Plasma disruptions load. The Post was designed with stainless steel 316LN and CFRP that have low thermal conductivity and high structural strength at low temperature. In order to verify the possibility of fabrication and the structural safety. a whole scale prototype of the KSTAR magnet supporting post was manufactured and tested. Static and compressive cyclic load tests under the maximum Plasma vertical disruption load and the magnet dead weight were performed. The teat results showed that the magnet supporting post of KSTAR Tokamak was possible to manufacture and structurally rigid.

  • PDF

Structural performance of renovated masonry low bridge in Amasya, Turkey

  • Cakir, Ferit;Seker, Burcin S.
    • Earthquakes and Structures
    • /
    • v.8 no.6
    • /
    • pp.1387-1406
    • /
    • 2015
  • Masonry bridges are the vital components of transportation systems. Although these bridges were constructed centuries ago, they have served a purpose from ancient times to the present day. However, the bridges have needed local renovation and therefore have been rebuilt over different periods in many places. This study focuses on Low Bridge, which is an example of renovated masonry bridges in Turkey. It essentially assesses the structural behavior of the masonry bridge and investigates the integrity of the renovated components. For this purpose, the mechanical properties of the bridge material have been primarily evaluated with experimental tests. Then the static, modal and nonlinear time history analyses have been carried out with the use of finite element methods in order to investigate the structural behavior of the current form of the bridge.

Safety Assessment of Cracked Prestressed concrete Cylinder Pipes (균열손상을 입은 프리스트레스트 콘크리트관의 안전도분석)

  • Kim, Young Jin;Lee, Sang Min;Lee, Ki Seong
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.2 no.3
    • /
    • pp.168-175
    • /
    • 1998
  • This study investigated the structural performance of the precast prestressed cylinder pipe having cracked under construction. The finite element formulation of PPC pipe incorporates Asoild elements using SAP90 program and the radial prestress force was transformed into the eqivalent external pressure. The analytical results were compared with the experimental results of full scale tests on PPC pipes subjected to static load. It is shown that the proposed modelling gives a realistic represention of the actual behavior. The analytical procedure is used to calculate the stresses in the PPC pipes and to check the crack opening under various situations such as bedding angle, earth pressure, and earth cover. Finally, the proposed modelling and analytical procedure should be especially usefull for the safety assessment of the PPC pipes under general loading conditions.

  • PDF

Development of an Efficient Notching Toolkit for Response Limiting Method

  • Shin, Jo Mun
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.40-46
    • /
    • 2021
  • At launch, satellites are exposed to various types of structural loads, such as quasi-static loads, sinusoidal vibrations, acoustic/random vibrations, and shocks. The launch environment test is aimed at verifying the structural stability of the test object against the launch environment. Various types of launch environments are simulated by simple vibration, acoustic, and shock tests considering possible test conditions in ground. However, the difference between the launch environment and the test environment is one of the causes of excessive testing. To prevent overtesting, a notching technique that adjusts the frequency range and the input load considering the design load is applied. For notching, specific procedures are established considering the satellite development concept, selected launch vehicle, higher system requirements, and test target level. In this study, the notching method, established procedure, and development of a notching toolkit for efficient testing are described.