• Title/Summary/Keyword: Structural requirements

Search Result 932, Processing Time 0.03 seconds

Structural safety factor for small unmanned aircraft (소형 무인기 구조 안전계수)

  • Kim, Sung-Joon;Lee, Seung-gyu;Kim, Tae-Uk
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.25 no.2
    • /
    • pp.12-17
    • /
    • 2017
  • Manned aircraft structural design is based on structural safety factor of 1.5, and this safety factor is equivalent to a probability of failure of between 10-2 and 10-3. The target failure probability of FARs is between 10-6 and 10-9 per flight according to aircraft type. NATO released STANAG 4703 to established the airworthiness requirements for small UAV which is less than 150kg. STANAG 4703 requires the Target Level of Safety according to MTOW. The requirements of failure probability for small UAV is between 10-4 and 10-5. In this paper, requirements of airworthiness certification for small UAV were investigated and the relationship of safety factors to the probability of structural failure is analyzed to reduce measure of safety factor and structural weight of unmanned aircraft.

A Study on the Structural Strength of the Rolling Stock Seat Frame (철도차량 시트프레임의 강도 평가 연구)

  • 구정서;조현직
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.3
    • /
    • pp.130-138
    • /
    • 2004
  • In this paper, the structural strength of a rolling stock seat were numerically evaluated under several design load conditions based on the UIC requirements. The rot]ins stock seat was designed for the high speed train of a Chinese conventional line. To maximize its weight reduction and structural strength, an aluminium alloy, ALDC8-T5, was applied to the base frame, side frames and armrests. The designed seat frame satisfied the strength requirements on inertia loads and fatigue test conditions. However, it couldn't satisfy the requirements on the static test conditions of UIC 566 OR. Therefore, some design modifications were suggested and numerically evaluated whether the static test requirements could be satisfied or not.

A Study on the Structural Strength of the Rolling Stock Seat Frame (유한요소해석을 이용한 철도차량 시트프레임의 정적 강도 평가에 관한 연구)

  • Koo, Jeong-Seo;Cho, Hyun-Jik
    • Proceedings of the KSR Conference
    • /
    • 2003.10c
    • /
    • pp.49-58
    • /
    • 2003
  • In this paper, the structural strengths of a rolling stock seat were numerically evaluated under several design load conditions based on the UIC requirements. The rolling stock seat was designed for the high speed train of a Chinese conventional line. To maximize its weight reduction and structural strength, some aluminium alloys like 6N01-T5 and ALDC8-T5 were applied to the base frame, side frame and armrest. The designed seat frame satisfied the strength requirements on inertia loads due to accelerations, and fatigue test conditions. However, it violated the requirements on the static test of UIC 566 OR. Some design modifications were suggested and numerically evaluated to satisfy the static test requirements.

  • PDF

Comparative Study on Structural Requirements of Part 23 Normal Category and VLA (Part 23 보통급 비행기와 VLA 비행기의 구조분야 감항기술기준 요건 비교 연구)

  • Kim, Seung-Kyem
    • Journal of Aerospace System Engineering
    • /
    • v.7 no.2
    • /
    • pp.42-46
    • /
    • 2013
  • In 2010, Airworthiness standard for VLA(Very Light Airplane) category was newly introduced as KAS Part VLA. KAS Part VLA is an adaption of EASA CS-VLA which was developed to reduce unnecessary burden of manufacturer of very light, simple, single-reciprocating-engine/propeller powered airplanes having low stall speeds by tailoring some requirements of Part 23. In this paper, difference and similarity of structural requirements between Part 23 and VLA was analyzed.

Development of Drift Design Methods with Weight Modification Factors (중량 수정계수를 고려한 변위조절설계법 개발)

  • 서지현;박효선
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.10a
    • /
    • pp.161-168
    • /
    • 2003
  • In the drift design of high-rise buildings, once the geometry and dimensions of a structure are predetermined, engineer's remaining work is determination of the member size to satisfy the strength and the stiffness requirements. For the case of highrise buildings, designs are determined by the stiffness requirements at the final stage of structural design. Thus, engineers try to find a minimum weight design with maximum lateral stiffness. However, there is no guideline for engineers on the required weight of structures per unit area to satisfy the stiffness requirements. In this study, drift design method considering weight modification factors are presented and applied to a 20-story structure. The proposed drift design method considering weight modification factors may give the guideline for engineers on the amount of structural weight to attain target displacement.

  • PDF

Structural Design Requirements and Safety Evaluation Criteria of the Spent Nuclear Fuel Disposal Canister for Deep Geological Deposition (심지층 고준위폐기물 처분용기에 대한 설계요구조건 및 구조안전성 평가기준)

  • Kwon, Young-Joo;Choi, Jong-Won
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.5 no.3
    • /
    • pp.229-238
    • /
    • 2007
  • In this paper, structural design requirements and safety evaluation criteria of the spent nuclear fuel disposal canister are studied for deep geological deposition. Since the spent nuclear fuel disposal canister emits high temperature heats and much radiation, its careful treatment is required. For that, a long term(usually 10,000 years) safe repository for the spent nuclear fuel disposal canister should be secured. Usually this repository is expected to locate at a depth of 500m underground. The canister which is designed for the spent nuclear fuel disposal in a deep repository in the crystalline bedrock is a solid structure with cast iron insert, corrosion resistant overpack and lid and bottom, and entails an evenly distributed load of hydrostatic pressure from underground water and high pressure from swelling of bentonite buffer. Hence, the canister must be designed to withstand these high pressure loads. If the canister is not designed for all possible external loads combinations, structural defects such as plastic deformations, cracks, and buckling etc. may occur in the canister during depositing it in the deep repository. Therefore, various structural analyses must be performed to predict these structural problems like plastic deformations, cracks, and buckling. Structural safety evaluation criteria of the canister are studied and defined for the validity of the canister design prior to the structural analysis of the canister. And structural design requirements(variables) which affect the structural safety evaluation criteria should be discussed and defined clearly. Hence this paper presents the structural design requirements(variables) and safety evaluation criteria of the spent nuclear fuel disposal canister.

  • PDF

Structural Analysis for VVIP Cabin Compartment Modification STC of Commercial Airplane

  • Lee, Sang Hoon;Bang, Dae Han;Choi, Sang Min;Choi, Hang Suk
    • Journal of Aerospace System Engineering
    • /
    • v.15 no.4
    • /
    • pp.30-39
    • /
    • 2021
  • This paper presents a study on the design and structural substantiation of the interior structure of the new VVIP aircraft. In this study, the structural design and analysis of the compartment with aluminum alloy and sandwich composite panel were performed. The structural design requirements from the Federal Aviation Administration were identified. The structural analysis of the compartment was performed by the utilization of the finite element analysis method, for the structural design process. Therefore, the designed cabin compartment secured the structural integrity, and satisfied its certification standards and design requirements via structural analysis.

The Structural Design of Tianjin Goldin Finance 117 Tower

  • Liu, Peng;Ho, Goman;Lee, Alexis;Yin, Chao;Lee, Kevin;Liu, Guang-lei;Huang, Xiao-yun
    • International Journal of High-Rise Buildings
    • /
    • v.1 no.4
    • /
    • pp.271-281
    • /
    • 2012
  • Tianjin Goldin Finance 117 tower has an architectural height of 597 m, total of 117 stories, and the coronation of having the highest structural roof of all the buildings under construction in China. Structural height-width ratio is approximately 9.5, exceeding the existing regulation code significantly. In order to satisfy earthquake and wind-resisting requirements, a structure consisting of a perimeter frame composed of mega composite columns, mega braces and transfer trusses and reinforced concrete core containing composite steel plate wall is adopted. Complemented by some of the new requirements from the latest Chinese building seismic design codes, design of the super high-rise building in high-intensity seismic area exhibits a number of new features and solutions to professional requirements in response spectrum selection, overall stiffness control, material and component type selection, seismic performance based design, mega-column design, anti-collapse and stability analysis as well as elastic-plastic time-history analysis. Furthermore, under the prerequisite of economic viability and a series of technical requirements prescribed by the expert review panel for high-rise buildings exceeding code limits, the design manages to overcome various structural challenges and realizes the intentions of the architect and the client.

Challenges in Structural Design of Bumeo W-project

  • Kim, Jong Soo;Jo, Duck Won;Choi, Eun Gyu
    • International Journal of High-Rise Buildings
    • /
    • v.9 no.2
    • /
    • pp.167-173
    • /
    • 2020
  • W-Project is 60-story mixed-use residential building complex project in Daegu, the third biggest city in South Korea. There are lots explorable items to be solved to secure structural safety and meet the serviceability requirements. This paper describes what kind of structural system is optimized based on the architectural requirements and structural components design and the grade of concrete strength altered on floors. The defining process of lateral resisting system of outrigger compared to the core ratio of typical plan is illustrated in detail.

Evaluation of RPV according to alternative fracture toughness requirements

  • Lee, Sin-Ae;Lee, Sang-Hwan;Chang, Yoon-Suk
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1271-1286
    • /
    • 2015
  • Recently, US NRC revised fracture toughness requirements as 10CFR50.61a to reduce the conservatism of 10CFR50.61. However, unlike previous studies relating to the initial regulation, structural integrity evaluations based on the alternative regulation are not sufficient. In the present study, PTS and P-T limit curve evaluations were carried out by using both regulations and resulting data were compared. With regard to the PTS evaluation, the results obtained from the alternative requirements were satisfied with the criterion whereas those obtained from the initial requirements did not meet the criterion. Also, with regard to the P-T limit curve evaluation, operating margin by 10CFR50.61a was greater than that by 10CFR50.61.