• 제목/요약/키워드: Structural Behavior

검색결과 7,228건 처리시간 0.033초

API-X80 라인파이프의 좌굴 안정성 평가 (Buckling Behavior of API-X80 Linepipe)

  • 조우연;안성수;윤태양;유장용
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.211-216
    • /
    • 2007
  • The objective of this paper is to present the results of an experimental and a finite-element investigation into the behavior of X80 grade pipes subjected to bending. For the pipe specimens comprising the test series, different D/t is applied to be representative of those that can be expected in the field. Results from the numerical models are checked against the observations in the testing program and the ability of numerical solutions to predict pipe moment capacity. curvatures. and buckling modes is established. A finite-element model was developed using the finite-element simulator to predict the local buckling behavior of pipes. The comparison between the numerical and the experimental results demonstrates the ability of the analytical model to predict the local buckling behavior of pipes when deformed well into the post-yield range.

  • PDF

변형된 실리콘의 미세구조와 기계적 거동 (The Microstructure and Mechanical Behavior of Deformed Silicon)

  • 김성원;김형태
    • 한국세라믹학회지
    • /
    • 제46권5호
    • /
    • pp.510-514
    • /
    • 2009
  • The microstructure and mechanical behavior of deformed silicon were characterized using transmission electron microscopy and nanoindentation. Structural defects such as stacking faults and dislocations were observed through the diffraction contrast in transmission electron microscopy. The mechanical properties of deformed Si and 111 Si wafer and mechanical behaviors during contact loading were also characterized using nanoindentation. The hardness values of silicon samples were ${\sim}10$ GPa and the elastic modulus were varied with indentation conditions. Elbow or pop-out behaviors were found in load-displacement curves of silicon samples during nanoindentation. Deformed silicon showed 'pop-out' behavior more frequently under the load of 10 mN, which is attributed to the structural defects in deformed silicon.

Finite Element Formulation using Arbitrary Lagrangian Eulerian Method for Saturated Porous Media

  • Park, Taehyo;Jung, Sochan
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.375-382
    • /
    • 2003
  • Porous media consist of physically and chemically different materials and have an extremely complicated behavior due to the different material properties of each of its constituents. In addition, the internal structure of porous media has generally a complex geometry that makes the description of its mechanical behavior quite complex. Thus, in order to describe and clarify the deformation behavior of porous media, constitutive models for deformation of porous media coupling several effects such as flow of fluids of thermodynamical change need to be developed in frame of Arbitrary Lagrangian Eulerian (ALE) description. The aim of ALE formulations is to maximize the advantages of Lagrangian and Eulerian methods, and to minimize the disadvantages. Therefore, this method is appropriate for the analysis of porous media that are considered for the behavior of solids and fluids. First of all, governing equations for saturated porous media based on ALE description are derived. Then, weak forms of these equations are obtained in order to implement numerical method using finite element method. Finally, Petrov-Galerkin method Is applied to develop finite element formulation.

  • PDF

철근콘크리트 벽체의 초기재령 거동 해석 (Early-Age Behavior of Base Restrained RC Walls)

  • 곽효경;하수준
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2003년도 가을 학술발표회 논문집
    • /
    • pp.251-258
    • /
    • 2003
  • The early -age behavior of base restrained reinforced concrete (RC) walls is analyzed using a three-dimensional finite element method in this study. After calculating the temperature and internal relative humidity variations of an RC wall, determination of stresses due to thermal gradients, differential drying shrinkage, and average drying shrinkage is followed, and the relative contribution of these three stress components to the total stress is compared. The mechanical properties of early-age concrete, determined from many experimental studies, are taken into consideration, and a discrete reinforcing steel derived using the equivalent nodal force concept is also used to simulate the cracking behavior of RC walls. In advance, to Predict the crack spacing and maximum crack width in a base restrained RC wall, an analytical model which can simulate the post-cracking behavior of an RC tension member is introduced on the basis of the energy equilibrium before and after cracking of concrete.

  • PDF

H형강보.각형강관기둥 접합부의 연성도를 고려한 골조의 거동에 관한 연구 (A Study on the Behavior of Frame with Connections between H-Beams and S . H . S Columns considering Joint Flexibility)

  • 강석봉;김이두;박순규;김재훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1997년도 봄 학술발표회 논문집
    • /
    • pp.211-218
    • /
    • 1997
  • Analysis of structures are usually executed under the assumption that connections are either ideally pinned joint or fully rigid joint. But in general all structures is connected under the semi-rigid connections. Semi-rigid connect ions have demerits that is simplification work on connection's behavior, moment-rotation relationships of connect ions , apprehension of nonlinear analysis etc. On the other hand there is merits that is improvements of serviceability, economic efficiency, construction in predicting real behavior frames. This study is to make model of connect ions by based on experimental study and after analysis on frames considering characteristics of semi-rigid connections. semi-rigid connection's influence on the behavior of structures and fundamental data on application of structures that is connected between S H S column and H beam is exhibited.

  • PDF

Seismic behavior of strengthened reinforced concrete coupling beams by bolted steel plates, Part 1: Experimental study

  • Zhu, Y.;Su, R.K.L.;Zhou, F.L.
    • Structural Engineering and Mechanics
    • /
    • 제27권2호
    • /
    • pp.149-172
    • /
    • 2007
  • An experimental study of five full-scale coupling beam specimens has been conducted to investigate the seismic behavior of strengthened RC coupling beams by bolted side steel plates using a reversed cyclic loading procedure. The strengthened coupling beams are fabricated with different plate thicknesses and shear connector arrangements to study their respective effects on load-carrying capacity, strength retention, stiffness degradation, deformation capacity, and energy dissipation ability. The study revealed that putting shear connectors along the span of coupling beams produces no significant improvement to the structural performance of the strengthened beams. Translational and rotational partial interactions of the shear connectors that would weaken the load-carrying capacity of the steel plates were observed and measured. The hierarchy of failure of concrete, steel plates, and shear connectors was identified. Furthermore, detailed effects of plate buckling and various arrangements of shear connectors on the post-peak behavior of the strengthened beams are discussed.

요철형 PE-PANEL과 콘크리트 합성구조물의 구조해석 (The Structural Analysis of Corrugated Polyethylene-Plastic Form Panel and Concrete of Composite System)

  • 김두환;박태인;박우영;한석규
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.91-96
    • /
    • 2001
  • Theoretical definitions of mixed behavior of PE panel and connote should have preceded to cause a mixed behavior of connote and polyethylene which have different elastic module, one-line expansion coefficients, poison ratios, compressive strengths and tensile strengths. Consequently, changes are analyzed through experiment process to identify the effects on interpretation of mixed behavior on the basis of temperature change of structures, temperature rise of concrete other than PE panel due to hydration heat temperature rise of concrete other than PE panel due to drying and contraction, working of hydrostatic pressure by storage and temperature gradient From the results of interpretation of the analysis, it is concluded that PE panel have slight influences on the change of guess of structures and maintains structural stability compared with concrete structures without PE panel.

  • PDF

비탄성 변형 이론을 바탕으로 한 Mg-Al 합금의 슬립기구 천이 현상 해석 (Effect of Slip System Transition on the Deformation Behavior of Mg-Al Alloy: Internal Variable Based Approach)

  • 이현석;장영원;방원규
    • 소성∙가공
    • /
    • 제13권6호
    • /
    • pp.535-539
    • /
    • 2004
  • Although magnesium has high potential for structural material due to the lightweight and high specific strength, the structural application has been limited by the low ductility at room temperature. The reason of the poor ductility is few activated slip systems of magnesium (HCP structure) during deformation. As temperature increases, however, additional non-basal slip systems are incorporated to exhibit higher ductility comparable to aluminum. In the present study, a series of tensile tests of Mg-Al alloy has been carried out to study deformation behavior with temperature variation. Analysis of load relaxation test results based on internal variable approach gave information about relationship between the micromechanical character and corresponding deformation behavior of magnesium. Especially, the material parameter, p representing dislocation permeability through barriers was altered from 0.1 to 0.15 as the non-basal slip systems were activated at high temperature.

Behavior of fibre reinforced cementitious material-filled steel tubular columns

  • Kharoob, O.F.;Taman, M.H.
    • Steel and Composite Structures
    • /
    • 제23권4호
    • /
    • pp.465-472
    • /
    • 2017
  • This paper presents an experimental study, investigating the compressive behavior of glass-fibre reinforced and unreinforced cementitious material-filled square steel tubular (GFCMFST and CMFST) columns. The specimens were manufactured by using high performance cementitious materials without using coarse aggregate. The influence of adding glass-fibres to the mix on the behavior of both axially and eccentrically loaded columns is considered. It was found that adding glass fibre improvesthe confinement behavior, the axial compressive strength, the stiffness and the toughness of both axially and eccentrically loaded columns. The compressive strength of axially loaded columns is compared with strength predictions according to EC4 and the AISC specification. It was found that the design predictions according to EC4 and the AISC codes provide conservative results for CMFST and GFCMFST columns. Alternatively, the axial load-bending moment interaction diagrams specified in theEC4 are conservative for the eccentrically tubular CMFST and GFCMFST tested columns.

SSI effects on the redistribution of seismic forces in one-storey R/C buildings

  • Askouni, Paraskevi K.;Karabalis, Dimitris L.
    • Earthquakes and Structures
    • /
    • 제20권3호
    • /
    • pp.261-278
    • /
    • 2021
  • In the current work, a series of seismic analyses of one-storey asymmetrical reinforced concrete (R/C) framed buildings is accomplished while the effect of soil deformability on the structural response is investigated. A comparison is performed between the simplified elastic behavior of R/C elements according to the structural regulations' instructions to the possible non-linear behavior of R/C elements under actual circumstances. The target of the time history analyses is the elucidation of the Soil-Structure Interaction (SSI) effect in the seismic behavior of common R/C structures by examining the possible elastic or elastoplastic behavior of R/C sections because of the redistribution of the internal forces by employing a realistic damage index. The conclusions acquired from the presented elastic and elastoplastic analyses supply practical guidelines towards the safer design of structures.