• Title/Summary/Keyword: Stress drop

Search Result 373, Processing Time 0.027 seconds

A racking Design of the Monitor by Considering the Free Drop Impact (자유낙하 충돌을 고려한 모니터 포장설계)

  • Yun Seong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.12 s.177
    • /
    • pp.117-123
    • /
    • 2005
  • This paper deals with the finite element model of the monitor fur the simulation of directional free drop tests such as the backward and vertex free drop as well as the associated free-drop experiment. The model was made for an unconditional stable solution fur the explicit integration algorithm. It was found through the comparison between simulation and experimental results that the general behaviors at the time of impact were observed to well correlate with each other in terms of acceleration, displacement, contact force and stress of monitor components.

A Finite Element Model for the Free Drop Test of the Monitor Packed by Cushioning Materials (완충 포장한 모니터의 자유낙하시험을 위한 유한요소모델)

  • 황용익;윤성호
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2002.10a
    • /
    • pp.78-85
    • /
    • 2002
  • This paper deals with the finite element model of the monitor for the simulation of directional free drop tests such as backward, sideward, edge and vertex drop. The model was made for an unconditional stable solution for the explicit integration algorithm. The general behaviors at the time of impact were found to well correlate with the actual situation in terms of acceleration, displacement, contact force and stress of monitor components even though the experiment of the associated drop is performed for the validity of the model.

  • PDF

Experimental Investigation on the Flow Characteristics of ER Fluids III (3nd Report, Flow-Pressure Drop Characteristics clearance between Two Parallel Plate) (ER유체의 유동특성에 관한 실험적 연구 III (평행평판 간극내의 유량-압려강하 특성))

  • 김도태
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.10a
    • /
    • pp.399-404
    • /
    • 1999
  • Electro-rheological(ER) fluids are suspensions which show an abrupt increase in rheological properties under electric fields. The rheological response is very rapid and reversible when the electric field is imposed and/or removed. Therefore, there are many practical applications using the ER fluids. The purpose of the present study is to examine the flow characteristics of electro-rheological fluids. The field-dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Then the steady relationshup between pressure drop and flow rate of the ERF was two fixed parallel-plates was measured under application of an electric fields. The electrical and rheological properties of zeolite based electro-rheological fluids were reported.

  • PDF

Characteristic Experiment of a Hydraulic Control Valve by Using Electro-Rheological Fluid (ERF를 이용한 유압제어밸브의 특성실험)

  • Kim, Dong-Su;Park, Jae-Beom;Jang, Seong-Cheol
    • 연구논문집
    • /
    • s.30
    • /
    • pp.93-99
    • /
    • 2000
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. The electrical and rheological properties of zeolite based the ER fluids were reported. The electric field dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Using ER fluids, it is possible to directly interface between electric drop and flow rate of the ER fluid was hydraulic control valve measured under application of an electric field. The purpose of the present study is pressure drop measurement of an ER valve by using strain gage. The performance characteristics of the valve system are evalusted in terms of pressrue fixed with respect to the intensity of employed electric fields and flow rates. As a result, it is esperimentally confirmed that pressure control valve using ER fluids applicable to use in hydraulic power systems.

  • PDF

A study on the strengthening of Sodalime glass using ion exchange method (이온강화법을 이용한 소다라임 글라스 강화에 관한 연구)

  • Ahn, H.W.;Oh, J.H.;Kweon, S.G.;Choi, S.D.
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.13 no.6
    • /
    • pp.145-151
    • /
    • 2014
  • The glass used for mobile display windows is required to have high strength. Chemical strengthening by means of ion exchange is widely used glass. The depth of the layer and the compressed stress are affected by tempering temperature and time. The purpose of this study is to investigate the range of DOL and CS, which to less breakage during reliability tests such as the ball drop test, hole drop test, 3-point bending test, drop test, and tumble test with Soda-lime Glass.

Drop Simulation of Puppy Robot by Toys Safety Standards (완구 안전검사 기준을 적용한 강아지 로봇의 낙하 해석)

  • Chung Tae-Eun;Kim Jun-Gi;Sin Hyo-Chol
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2005.06a
    • /
    • pp.710-713
    • /
    • 2005
  • Many impact or drop test researches of home appliances are published, but those of toys cannot be found easily. External impacts are the primary causes of fracture of toys. For impact proof design, the finished product should pass an impact test after molding design. There are several international toy safety standards or requirements such as US CPSC(Consumer Product Safety Commission), ASTM F963-96a, EN71 and so on. The puppy robot which patrols around the house, namely, the watchdog was selected to investigate toy safety because it has considerable weight and outer panels are made of plastics. First the model of watchdog robot was obtained by 3 dimensional scan. Surface data can be generated from 3D polygon data of the watchdog. A reliable drop simulation method for the watchdog was established using Pam-crash program according to Korean toy safety standards. When there is a low impact allowance value, the molding design should be reinforced or changed. It was found that the maximum impact stress reaches the ultimate stress of panel material.

  • PDF

Integrity of the Reactor Vessel Support System for a Postulated Reactor Vessel Closure Head Drop Event

  • Kim, Tae-Wan;Lee, Ki-Young;Lee, Dae-Hee;Kim, Kang-Soo
    • Nuclear Engineering and Technology
    • /
    • v.28 no.6
    • /
    • pp.576-582
    • /
    • 1996
  • The integrity of reactor vessel support system of the Korean Standard Nuclear Power Plant (KSNPP) is investigated for a postulated reactor vessel closure head drop event. The closure head is disassembled from the reactor vessel during refueling process or general inspection of reactor vessel and internal structures, and carried to proposed location by the head lift rig. A postulated closure head drop event could be anticipated during closure head handling process. The drop event may cause an impact load on the reactor vessel and supporting system. The integrity of the supporting system is directly relevant to that of reactor vessel and reactor internals including fuels. Results derived by elastic impact analysis, linear and non-linear buckling analysis and elasto-plastic stress analysis of the supporting system implied that the integrity of the reactor vessel supporting system is intact for a postulated reactor vessel closure head drop event.

  • PDF

Determination of Consolidation Characteristics in Fine Soils Evaluated by Piezocone Tests (콘 관입시험을 이용한 연약지반 압밀특성 평가)

  • Lim, Beyong-Seock
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.02a
    • /
    • pp.42-58
    • /
    • 2000
  • 본 연구의 목적은 연약지반의 압밀계수 측정에 있어 Piezocone 관입시험을 이용할 때 관입시험자체의 정확성과 시험결과들에 미치는 여러 가지 지반공학적 영향요소들을 고려하려는데 있다. 본 연구의 연구실험방법으로는, Piezocone 관입을 위한 연약모형지반 조성을 위하여 초대형 Slurry Consolidometer에 Free Stress 상태의 Slurry를 45일간 압밀시킨 후 Automatic Computer Control Calibration Chamber (LSU/CALCHAS; Louisiana State University Calibration Chamber System)에 옮긴후 다시한번 압밀시키는 Two-Stage Consolidation Method를 사용하였다 동시에 연약모형지반내에 8개의 Piezometer를 설치하여 Piezocone 관입시 유발되는 지반 내에서의 과잉간극수압의 변환을 측정하였다. 총 25개의 Piezocone 시험중 4개는 Standard 10$\textrm{cm}^2$ Piezocone이고, 나머지 21개는 Miniature Piezocone이 사용되었다. 모형지반은 여러 가지 Boundary Condition들과 Stress Condition 그리고 Stress History등을 고려하여 조성되었다. 또한 Dissipation Test직후의 압밀특성을 확인하기 위하여 0.01초당 한 개이상의 실측점을 측정할 수 있는 Digital-Oscilloscope를 이용하였다. 특히 Dissipation Test, 즉시 Piezocone의 Filter Element에 잡히지 않는 과잉간극수압의 Initial Drop 존재에 관한 기존의 추측을 실제 실험치로 확인할 수 있었다.

  • PDF

The Numerical study for flow characteristics of bifurcation in blood vessel (혈관 분지부의 유동 특성에 대한 수치해석 연구)

  • Lee, In-Sub;Ryou, Hong-Sun
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.741-746
    • /
    • 2003
  • The main objective of present study is to obtain information for flow characteristics, such as velocity and wall shear stress, of bifurcation in blood vessel. Branch flows for Newtonian fluids are simulated by using Fluent V.6.0. The numerical simulations are carried out for five cases divided by different values of bifurcation angle and area ratio. As a result of simulation, high wall shear stress is appeared at the bifurcated region. As increasing bifurcation angle, pressure drop is increasing. In addition, as the area is decreasing, pressure drop and wall shear stress is increasing.

  • PDF

Study of Hot Salt Stress Corrosion Crack Initiation of Alloy IMI 834 by using DC Potential Drop Method

  • Pustode, Mangesh D.;Dewangan, Bhupendra;Raja, V.S.;Paulose, Neeta;Babu, Narendra
    • Corrosion Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.203-208
    • /
    • 2016
  • DC potential drop technique was employed during the slow strain rate tests to study the hot salt stress corrosion crack (HSSCC) initiation at 300 and $400^{\circ}C$. Threshold stresses for HSSCC initiation were found to about 88 % of the yield strength at both temperatures, but the time from crack initiation to final failure (${\Delta}t_{scc}$) decreased significantly with temperature, which reflects larger tendency for brittle fracture and secondary cracking. The brittle fracture features consisted of transgranular cracking through the primary ${\alpha}$ grain and discontinuous faceted cracking through the transformed ${\beta}$ grains.